Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0029161_Regional Office Historical File Pre 2018
Michael F. Easley. Governor William G. Ross Jr.. Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek. P.E. Director Division or Water Quality .August 18, 2005 Mr. Terry Predzimirski, President 1125 iGreenwood Cliff Drive Charlotte,'North Carolina28204 Subject: 'Permit No. WQ0029161 Lot 1-A Prescot Subdivision Prescot Development, tLC Wastewater Collection System Extension Union County, North Carolina DearMr. "Predzirriirski: 'In accordance with your applicationvreceived on July 29, 2005, we areforwarding herewith a corrected .Permit:No..WQ0029161, dated August 18, 2005, for the construction and operation of the subject wastewater collection system extension. Thispermit.shall be effective from:the date of issuance .until•rescinded;:and shall be subject to the conditions -and limitations as specified .therein. This•cover lettershalibe•considered a part of this permit and is therefore incorporated therein by reference. Please .pay particular :attention to Permit •Condition 3 which 'requires that the wastewater collection facilitiesbe properlyoperated and maintained in accordance with 15A:NCAC 2H .0227 or any individual system -wide collectioniystem permit issued to.the Permittee. :Permitting ,of this.project•does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) :Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the .Fast -Track .Permitting of .Pump Stations and :Force 'Mains adopted June 1, 2000, as applicable, .unless specifically mentioned 'herein. Division approval is :based -on .acceptance of the .certification ;provided by a North 'Carolina -licensed :Professional Engineer in the application. +It shall .be . the .Permittee's .responsibility to ensure .that .the as -constructed :project meets the appropriate -design criteria and rules. 'Failure to comply may result in rpenalties in accordance with 'North Carolina General 'Statute §143-215.6A through §143-215.6C, construction of additional -or replacement wastewater collection facilities, and/or referral of the North Carolina- licensed Professional 'Engineer to the licensing board. Nike Carolina Naturahq Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enrstate.ncus Customer Service:1-877-623.6748 An Equal Opportunity/Affirmative Action Employer— 50% Recyded110% Post Consumer Paper : ACK APPLICATION for (,'RAV TY SF RS, PUMP S'FAT,IO S, AND FORCE ;NL S PAGE 3 USE THE TAB KEY TO MOVE FROM FIE i..r TO FIELD! Owner la. Prescot Development, LLC Full Legal Name (company, municipality, HOA, utility, e Application Number: do be completed by DWQ) ib- Terry Predzimirski, President Signing Official Name and Title (Please review 15A NCAC 2H .02 ..� _� 06 b for authonzedsigning i. � Oging officials!) Q 1 c, The - legal entity who will own this system is: r L� Individual [1 Federal 0 Municipality 0 State/County L Private Partnership Q.-"Corporation 0 Other (specify): CC 0 LL Z z 25 Greenwood Cliff Drive eet Address NC State l h. 704-377-4492 1 i. 704-377-4496 w µ Telephone Facsimile 2. Project (Facility) Information: 2a. Lot 1-A Prescot Subdivision _ Brief Project Name (permit will refer to this name) Contact Person. 1 e. Charlotte City 1 g. 28204 _. Zip Code diamondoak aol.com E-mail 2b, Union County Where Project is Located 3a. Michael Lash, P.E. Name and Affiliation of Someone Who Can Answer Questions About this Applica tion 3b. 704-847-3031 mikel@lasherigineering.com _�,� E-mail 1. Project is t New © Modification (of an existing permit) If Modification, Permit No. For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not. duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is L Public (skip to Item 8(3)) I r rivate (go to Item 2('a)) 2a. If private, applicant will be 2b. if slid, facilities owned by a (must choose one) Phone Number Retaining Ownership (i.e. store, church, single office, etc.) or L „) Public Utility (Instruction III) Z 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) O [_] Selling units (lots, townhomes. etc. - go to item B(2b)) 1— < 3. Union Count r Publir arks Department E Owner of Wastewater Treatment Facility' (WWTF) Treating Wastewater From This Project ce • 4a. Twelve Mile Creek W'.WaT,P. 4b. NC.0085359 LL Name of 1NWTF WWTF Permit No, Dept. 5b. 8`° 5c. WQ0028622 Z Union Court tlPublic Works r meowner Assoc./Developer (Instruction IV) Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Se The origin of this wastewater is (check all that apply): Residential Subdivision © Apartments/Condominiums 0 Mobile Home Park © School 0 Restaurant LD Office El Car Wash Institution Hospital El Church 0 Nursing Home Other (specify): . _....._ 7. Volume of wastewater to b_eperm tted in this project: 360 gallons per day 100 % Domestic Co % Industrial % Other (speco If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line Flow has already been allocated in Permit No. _ ❑ Rehabilitation or replacement of existing sewer with no new flow expected - Rev. 2 04/04 !RACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 l0 LLI 0 V11. o Qplans cc ccPump o LL z E re W p„ CO 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC .0219(I) for Item B(7) or the design flow for line or purnp station sizing if zero flow in the space below. Values that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance NCAC 2H .0219(I)(3). 2H other than with 15A 1 house @ 360 gpd = 360 gpd Oliou54 (396a(-0o , /20 apD) 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) i Length (feet) Gravity or Force (use the pull down Main menu) 1-114" 385 ' . Force Main 1 f ENTER TOTAL LINE LENGTH IN MILES 0.009 • Summary of Pump Stations to be Permitted (attach additional sheets as necessary) NIA Location ID j ; Power Reliability Option (self chosen - as shown on I Design Flow Operational Point (1- dual line feed; 2- permanent generator wWATS; 3- for cross-reference) I (MGD)-_ GPM @ TDH .portable generator wltelemetry; 4-wet well storage) Station 1 0.0004 17 @ 20' I 4 and Force applicable? why a 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations Mai (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as Yes ■ No If no, please reference the pertinent minimum design criteria or regulation and indicate variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? .....____.. Wetland/Stream Crossings - General Permit or 401 Certification? ■ Yes ■ No IIKA Sedimentation and Erosion Control Plan? ❑ Yes ■ No ErgrA Stormwater? ❑ Yes • No Er< _._-.____ _._..._..............._ .__..,_.._._._...__—... __.....,..__ 14. Does this project involve aerial lines or siphons? Check if yes: ■ Thesellnes_will.beconsidered_bieh. orioritvand must be checked_once everv_slxmonths _ 15. Does this project have gravity sewer lines designed at minimum slopes? Cf`• Be aware that the Division will not accept installed fines more than 10% flatter than the minimum slope. Lines installed outside this tolerance shouid be - corrected prior to submitting the final engineering certification.. PTA (]') - R'mu . f14/f15 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 • 0 a U LL a J U W H co (> 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web i Re or by t-rmitacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ❑ A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, ❑ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) Shown on USGS (INCLUDED) Name of Waterbody Twelve Mile Creek Unnamed Tributary County Union Waterbody Stream Waterbody River Basin Index Classification Catawba 11-138 Catawba Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! c Applicant's Certification: 1, Terry Predzimirski , attest that this application for Lot 1-A Prescot Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. ! understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a lass 2 misdemeanor which may include a fine not to exceed $10,000 as well as " ' 5enaities up to $25,000 per vion. la. Signing Official natur 2. Professional Engineer'Certification: Date l attest that this application for Lot 1-A Prescot Subdivision has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and.have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty ofa Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Michael W. Lash, P.E. Professional Engineer Name 2b. Lash Engineering, Inc. Engineering Firm 2c. 1226 Mann Dr. Suite 100 Address 2d. Matthews 2e. NC. 2f. 28105 City State Zip 2g. 704-847-3031 2h. 704-847-3041 2i. mikel@lashengineering.com Telephone Facsimile E-mail ..."%2 SEAL : . 14265 ''ic;7,�E11W A,,,`�� • Seal, Signature & Date FTA 02/03 - Rev. 2 04/04 Central Files: APS_ SVVP 08/03/05 Permit Number WQ0029161 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 360 Facility Facility Name Lot 1-A Prescot Subdivision Location Address Owner Major/Minor Region 'Minor Mooresville County Union Facility Contact Affiliation Owner Name Prescot Development, LLC J)atesIFVPntc Scheduled Orig issue App Received Draft Initiated Issuance 07/29/05 Renulated Activities Owner Type Non-Govemment Owner Affiliation Terry Predzimirski, president 1125 Greenwood Cliff Dr Charlotte NC 28204 Public Notice Issue Effective Expiration Subdivision Wastewater collection Outfall NULL Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasln AUG 1 0 2005 ,,u, LASH9',ftn ,L . .1 , , c- � 'Attention of: Dee Browder ENGINEERING i& 4Gr►zi t Consulting Engineers Company: NCDENR GMI, Mechanical, Electrical Division of Water Quality 1226 Mann Dr., Suite 100 From: Matthews, NC 28105 Michael Lash, P.E. Phone: 704/847-3031 Project: FAX: 704/847-3041 Prescot Subdivision Lot 1-A ��y14•. �` T l T7AN S M ITTAL •. • -Date: August 8, 2005 Special Instructions: • .a The following information relating to power outages was provided by Union Power Cooperative, as requested by your office. Single family residence : 360 gpd, with system operating 16 hours per day = 22.5 gph Union Power Cooperative 5-yr. average power outage = 2.82 hrs. 2004 average outage was 3.44 hrs. We have assumed the maximum average of 3.44 hrs. 3.44 hrs. x 22.5 gph = 77.4 gallons minimum storage required Proposed system summary: Total storage from "pump OFF" to rim = 6.5'-16" = 5.16' 24" diameter wetwell yields 16.23 cf or 121.4 gallons 121.4 gallons of storage provided is greater than 77.4 gallons required, therefore, we believe that adequate storage has been provided. Additionally, this will be used as a housing facility for rare events such as birthday parties, neighborhood meetings, etc. and not as a three bedroom residence generating 360 gpd. We have used that assumption for this analysis but it will not likely be realized. If I can be of any further assistance, please do not hesitate to call. Thank you. Page 1 of 1 Michael W. Lash From: "Maxwell, Robert" <robert.maxwell@union-power.com> To: <mikel@lashengineering.com> Sent: Friday, August 05, 2005 9:59 AM Subject: Power Outage History - Prescott Subdivision Mr. Lash, In response to your request for expected annual power outage time for Lot 1A of the Prescott Subdivision in Waxhaw, NC: Since no power has yet been installed to the Prescott Subdivision, Union Power Cooperative has no established outage history for this specific location. However, for the year 2004, Union Power Cooperative's systemwide outage rate was a cumulative 3.44 hours of outage time per account. For the 5 year period including years 2000- 2004, Union Power Cooperative customers experienced an average of 2.82 hours of outage time, per account, per year. Based on Prescott's location and surrounding electric facilities, 1 have no reason to expect that this subdivision's power outage time should be significantly greater, or less than, the average for our system as a whole. Please do not hesitate to call me or reply via email if you have any questions or I can be of further assistance. Robert Maxwell Manager of Engineering Union Power Cooperative 704-220-0712 (direct) 704-289-3145, ext. 3287 8/5/2005 `t. JJI JY! IIULIILJ JVI I L I IYu J L J 520.1, Li • ors® Pcnuie rump Group 2HP Residentiai Grinder Pump Rail System 'Package Basin Assembly Basin Assembly Top View & Side View 45 I 54. 7 a affffaaaaaaaa■araaaaaalr ■aaaara[ ss ■afaaaaraaaaaaaanafxaaaf aaarfaraaaaafafaaraaaaff ar■raaararimam arumfararaaaam a araara raaaa■raraaarfaf r mamespaffaaArrrrafraalf asaaar■afa■Crafaaaraafaa af■rllMaaar ■Manai'mae a* fpornare..! � MMsw ii i sat ogle iMM M M MMus aty: iiwFsfaL'rif- i'► ll I 77 TOP VIEW BASIN COVER CORROSION RESISTANT %" TI4K. STRUCTURAL POLYPROPYLENE SIDE VIEW PUMP GUIDE AND LIFTING PLATE JUNCTION BOX 1 /- MTG. BRACKET 11/4 BALL VALVE 1 1/2 DISCHARGE FLANGE 1 1/4 BALL VALVE 3 11/4 SUPPORT FLANGE RAIL. SUPPORT YOKE 1 1/4 PVC DISCHARGE • PIPE -GUIDE RAILS HIGH WATER ALARM S1, Received Time May,23. 5:05PM /AAA( .Aic ' 'S ! 5'A'7 3r/ J v1p•ad /-/1./ , f-' ,97 wrRs av r»t' - "'PM ..C-C /7 /ii,r / ..2.-69d1. r/5. � vrr sP. G ..nv +_c .A-7?Vsr?7d b ' •cvrr - "a - 'fin —' ' 2c..1 ems- S ci- 5 '7s;'%:1 W i '.7Tc-a.od <22. .-1.-7.nv/�aia' C lf, s ar' ,P r/ry - -,-6r' u". gVi' io GA/A' c!tY9/27, — A c''' 171L < 9 v 1 .. (./.716Y1m. N/40r.- / '-m-c ,v, /_4_,,,71::--w 9 C/L � 7 ' d S / SF '7 ,Y.vV.:?' a9 • .. - , "</ ke"7-1-?c:;' 2 ,o ,4_ ) E •='a , r✓v/ _ Gp. . nrW...49/7 /. ag.iva, . 7pcz r4/ ep -'d r . g0 .d'd a/fd „. X f - 7�'i/N/il/ S' Ct /,' /NeV 3.'ivd,'� ",' o5 ..?, g - .7:ra :.-ere,cy . /7a ,aC s=' 'A.P7 V '.C.'' : - %. = .9.a/, d I%rcag% lvaLG.e'7r,p 76./e2 7Ja f2076" 5: U4Niv1ng EHUGHES SUPPLY Prr zft 3d.al Lani- PT rge, Ld or a1 Et PERFORMANCE CURVE 30 25 20 15 10 S. GaL� Liters 614 027, 1� 116/1111111 mon mom Imo 40 'S® 80 119 er" F. E. Myers, 1101 Myers Parkway,Ashland, Ohio 44805-1969 419/289--1144, FAX: 419/289-6658, Wvtirw femyers.com'� R e c e i Y e d Ti P1.0 J u n-.. 6. iL 5: 3 5 P Me, Kitchener, Ontario N2G 4W5 zg.� 120 40 50 Submersible Grinder Pumps • 160 200 .' O. 619 P. 2 ppirr- vers to Pump Group 2HP Residential Grinder Pump Rail System Package.. Basin Assembly Basin Assembly Top•View & Side View TOP VIEW • aaaaawwwaaa aaaaaaaaa aaaaaaawaaaaauaaaawaa aaaauaaawaana uwnaaasa ■aaaaaaaaaaaaraalsaaa Bala aaaawaaaawaaaaaaaaawaaaa aaaaaaaa�aaawaaaawaaa aa aaauaaa aaaaaawaaaaaaa aarawaaaawaaawamammalians! awaaaxaaaaa aaaaawaaaraa aawaw aaaaaraaaaaawaawa amaaawasaanamainaamansman aaaaaaawwaaaaaaawaaa moo mil wail sfla Kin asaammaamsmaaaataaamasam aaaa■AawRaaaci-R`TL :T7 aaaaUa awaD•J�[�n2-y��NZ arr.waaar.aaaaa�.aaraaMaaa BASIN -COVER CORROSION RESISTANT W' THK. STRUCTURAL POLYPROPYLENE SIDE VIEW PUMP GUIDE AND LIFTING PLATE JUNCTION BOX 4.a" MAX.' L J 24DIA. FISERbLASS BASIN • BASIN DEPTH MTG. BRACKET 1 1/2 DISCHARGE FLgNCsE 1 1/4 BALL_ VALVE 54 1/4 SUPPORT FLANGE RAIL SUPPORT YOKE 1 1/4 PVC DISCHARGE • PIPE 1 GUIDE RAILS LIFTING CRAIN HIGH WATER ALARM li • Received Time May.23. 5:O5PM II.2405- 4r34PM ers° Grog) HUGHES SUPPLY 2HP Residential Grinder Pump Rail System Package r_ Structural Polypropylene Cover • 4' Control Panel and Visual Won Water Alarm Structural Plastic Junction sox PVC. Ball Type Shut Ott Valve and Handle PVC Discharge Pipe High Water Alarm Mercury Love/ Control !rile( Hub (Fled Mounted) ON and OFF Mercury Leval Controls .2 HP Grlihder Pump 2a • Dlomeldr by 90' Fiberglass Basin Guide Halls lJliinp Chain Concrete • Received Time May,23, 5,05PM 4:35PM Pentuirtamp Group HUGHES SUPPLY 'HP Residential Grinder Pump Rail System Package . Basin Assembly Technical Specifications 5. Piping Schedule 80 PVC discharge piping shall connect to the stationary discharge base lift assembly and terminate at a V/" discharge flange mounted on the basin at the height shown on the drawing. Cast Iron Check Valve SST stREYCB au FIBER FLAPPER l'NPT RAIL SUPPORT I Ind NPT 1_ _J CAST IRON Boar EpOXT COATED s. Check Valve A heavy duty spring loaded all rubber flapper type check valve with cast iron body shall be an integral part of the discharge seal assembly and shall lift out with the pump assembly. The valve design shall be such to allow for operation when negative heads, of up to 5 feet, are encountered, The valve shall be designed to operate at all pressures in the sewer system created by the grinder pumps. A flat set starless steel spring, integrally molded into the Buna N rubber flapper, shall be furnished in order,to prevent collection of debris in the check valve, All fasteners shall be stainless steel. 7, Inlet Flange , • A basin inlet flange for 4" SGH 44 plastic pipe shall be included, but not mounted on the basin. The flange to be mounted in the field at inlet N—height required by the installation, or as shown on the drawing. NO.-325 • P. 3 520/7-4 ■■umumo111r■r■na1s1■rr1■ 1111■C ■■r1■ir■rC1a1>,.■rr■rrmum mum ■1■r■r■mom • 1111111wA1 r■1■■■r1■■M■a 1rr11a■r 1rr■■■■M■1■r■■■■ r11s.■ ■C ■■us.MI t !kU11t1t em�lr lI■ WORM 11■tir■1■t'V l'7 :f1 "r7 ■■Stfl1■11■■■umLim1 rlomir1 Litt Out Assembly Received Time May.23. 5:05PM 4 Inlet Sealing Flange lipprAY. 2i. 1UU54: YM . HUGHLS SUYYLY 1- • Myers' p P Group 2HP Residential Grinder. Pump • Rail System Package Grinder Pump RECESSED IMPELLER GRINDER ASSEMBLY NU, 325 52k1,i 4S rralawrprrrall*prllaaRal aver■■■ ralrwwr r�llRrr■ iaasr>isas*w*arrmmmm ,rraaa onAlrr■ sumarrArrrra'mom MIME mw r r w r r allm a r rl sal t aallarrrrraaaalCrraalwaa WINES.ida. aIlt11111 --111I 01 ■aaawr■■raaaysimi .rm—Tr, a momrwraasaso•.( a-.1 of i s e:1 rrw� rar WGL2O-21 2HP Grinder Pump CONSTRUCTION FEATURES STATOR — Rating is 2 HP, 3450 RPM, $0 Hz, 230 volt single phase. Stator is pressed in for perfect alignment and best heat transfer. Oil conducts heat and lubricates bearings and seal_ . HEAT SENSOR — Protects motor from burn out due to excessive heat from any overload . condition. Automatically resets when motor has cooled. BEARINGS — Twb ball bearings Support shaft and rotor and take axial thrust. . SEAL CHAMBER — Two tandem mechanics seals in oil filled chamber prevent moisture from entering motor housing. Seal leak probi connected to red warning light indicates when excessive moisture has entered througl bottomseal signaling that repair is necetsan RECESSED IMPELLER — Cast iron recesse, impeller handles ground slurry without clogging or binding. No close clearances and all flow passages are•unobstructed. GRINDER ASSEMBLY — Impeller and shredding ring are replaceable without taking pump apart. Parts are of stainless steel hardened to 0-58-60 Rockwell. . rams. WAD M.Yx 115 22 20- 11 60 16 so 14- 1240 I0-- 20 o� 6 20 4- 2 10 co PERFORMANCE CURVE • � 1 �i.a.•• .:r 10 ES~ ~IO i 25 3s ip5 1 60• 41 2 .6 4 5 6. 7 2 9 10 11 GSAcirr gALL9tra P22 Mil GTE (uTh155) Received Time MaY.23. 5:05PM — MAY. 23. 2005, 4:36PM Ayers' HUGHES SUPPLY fiza'Ynmg Group -IP Residential Grinder Pump ail System Package grinder Pump Technical Specifications i. Pump impeller 'The pump impeller shall be of the recessed • .ype to provide an open unobstructed passage :hrough the volute for the .ground solids. The ,mpeller shall be constructed of cast iron and shall have pump out vanes on the back side of the impeller to keep solids from lower seal and reduce pressure at the seal faces. Impeller shall be threaded onto the stainless steel shaft. 7, Grinder Assembly & Construction The grinder assembly shall consist of a rotating radial cutter and a stationary shredding ring, and shall be mounted directly below the volute passage. The rotating cutter shall be threaded onto the stainless steel shaft and shall be locked with a screw and washer. The •tationary shredding ring shall be pressed onto ,An iron holding flange for easy removal. The flange -shall be provided with tapped back -off . NO. 325 P5J17-g pi rr amasswa■iaaamisriaaaaiiia aaaaarasaasirasaar■aaar■ =raarr■si■ ■a■■■aaar�■■ ri ■■rsaaaaAitiala■a■aar■Maa mum s*ar■aaaariramamas. mama-a_lrLrs.e.remsF.mr pru t ■asaboo rit1f1s111,•allr: 11• s■iiaiaii■rrssa■ raaam� iiiiiiisaiimr� + Ro i v I 1 t-i holes so that screws can be.used to push the shredding ring from the housing- Both the radial cutter and shredding ring shall be removable from the outside without dismantling pump. Grinder assembly shall be of such construction that no clearance adjustments are required when assembling. All grinding of solids shall be from the action of the radial cutter against the shredding ring. The radial cutter and shredding ring shall be of 4440 stainless steel hardened to • 5B-60 Rockwell C. 8. Pump & Motor Castings All iron casting shall be of high tensile cast iron and shall be properly cleaned, pre-treated With chromic rinse,.and painted with a high quality. enamel paint. Ail pump components that are not cast iron or stainless steel shall be galvanized orpainted with baked -on epoxy. All fasteners shall be #302 stainless steel. IPWIT. Z). ay) 4:iorm nuc�nt5 5Uf'i'LY . PIPPF- Myers� P t kPu ! GIMP ,2HP Residential Grinder Pump Rail ,System Package Electrical INU, 3 2.5 r. ' 521,E -a .ri.toi...•i.. WMMw...Aa EMI AA....EMM.. .A.i.i..>♦ OmMEIMMO MEMM:n:E1�Eii ..■..N.....MEA...iii..■ ■iiwAA:..i.A...iiii ERE ....ld.l''1i4r5}f—is3riR r'�s .....MU.U...Pr r^[ r1=r mmiMM MMMMMM 2C. r=I'l.■1r 2HP 230V 10 Control Panel • it t1l trP�e Csi 1111 L[ C rolc0o ✓ o 00— ✓ D 2HP 230Y 10 Control Panel 1d.nN (�1. I,.Jrnos+..40117 .mleuasow Plug -In Connector 2 •N Ro5CI10tl1XPowo[1Ii51 w 0U(. itt 555TRel$ w!1 [[ RIIEO FlR E 15P ct .115 55115 2HP 230V 10 Schematic Diagram 1:11511 a/9Ra01fl psw CA!Iet],Ea SLR/ EUIFneI . Er," 11.WII HUT flail 1.WIr HIIl1}I 11-11111 111111115 d[1l Mt I. MT rut! Plug-in Connector. A waterproof •male plug shall be supplied on the pump power and control cord and shall mat to a female socket mounted in the junction box. The pug and cord shall be of the proper size to handle the voltage and current requirements of the pump. • The plug and receptacle shall be of the molded to cable and double face design. The female half shall fit like a cork into the flexible shroud portion of the male. In addition, individual neoprene shoulders around contacts shall fit into recesses in female section. The cable shall be neoprene molded, one- piece design, and the connector shall have threaded coupling for positive tight connection and quick release. The mating connectors 'shall have an indexing tab to insure proper alignmenr Received Time MaYl23. 5:05PM ippOS 4:36PM HUGHES SUPPLY Single Single Phase 1 • NO 325 F. 7 CGL, CG, CNC, C'HV3 and CWl3V4 Simplex and Duplex Control Panels For 2-5 HP Single Phase Submersible Grinder Pumps and 1-5 HP Single Phase Submersible Non -Clog Pumps MYERS HAS RE -ENGINEERED THE 'CONTROL PANEL LINE FOR IMPROVED DURABILITY, RELIABILITY AND ECONOMY. CAD flexibility 'enhances our response time to help us better meet your control panel requirements. Contact your Myers distributor, or the Myers Ohio sales office at 419/289-1144 for more details.i ADVANTAGES BY DESIGN QUALITY' ELECTRICAL COMPONENTS ASSURE RELIABLE, AUTOMATIC PUMP OPERATION • IEC horsepower -rated motor contactors rated at over 1 rnillion cycles. u CG. CNC, CWIV3/4 have 1 pole ambient - compensated bi-metal overload relay. = CGL has Mixon overload. ▪ Designed for use with standard mercury float switches.'Uses three for simplex (off -on -alarm), four for duplex (oft -of override -alarm).. ■ Solid state alternating relay (ora. duplex only) to equalize pump wear. w Override relay to start second pump it first one fails for any reason. CORROSION RESISTANT POR LONG LIFE g Weatherlight NEMA 4X fiberglass enclosures. with aluminum back panels. MEETS NEC AND UL (508) STANDARDS POR SAFETY • UL-approved panel designs (label installed only on request). = Individual pump circuit breakers. ■ Separate control and alarm fuses. WHERE INNOVATION MEETS TRADITION Myers '5'Received Time'`MaY-.2.3.' 5:05PMf Pentair Pump Group HUMS SUN.?. • w6.312ii P. Priir• 2 HP Grinder Pump for Residential, Commercial and Industrial Applications 1 LISTED nil HE MYERS W151.20 IS A VERSATILE 2 HP SiTBMERSIBLE GRINDER PUMP DESIGNED SPECIFI- CALLY FOR USE.IN PRESSURE SEWER APPLICATIONS OR IN SYSTEMS WITH LONG DISCHARGE RUNS OR HIGH STATIC HEADS. It features a patented cutter mechanism and recessed impeller design to effeC- tively mascsrate typical domestic sewage solids into a fine slurry. The WGL20 can be installed in a variety of packaged systems. Factory-asserrnblect simplex or duplex packages with guide rail systems or suspended systems are available. Myers also has complete turn- key systems to make selection simple. Individual rail components are also available for installation in on - site concrete systems. Myers offers ct complete line of submersible sump, sewage, effluent, grinder, non - clog wastewater pumps, controls, basins, and aCces- Sories. For additional information, please contact your local Myers representative or the Myers • Ashland, Ohio sales office at 419-289-1144.. ADVANTAGES BY DESIGN IDEAL FOR USE IN PRESsiIRE SCR SYSTEMS. Recessed impeller provides Steep. non -overloading operating curve. DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE. 11 OiI-filled motor for maadmurn heat dissipation and constant bearing lubrication. R Recessed impeller reduces radial .bearing loads, increases bearing life. ' ▪ High torque capacitor start single phase or three • phase motors for assured starting under heavy • load. t>t Optional seal leak probe warns of seal leak condition, helps prevent costly motor damage. R Single phase motors k1Gve on -winding current and temperature sensitive overload. THE W&L20 IS DESIGNED FOR EASY MAINTENANCE. >a Shredding ring and grinder impeller are replace- able without dismantling pump or motor. Capacities To 40 GPM , 150 LPM Heads To 105 ft. 32.1 m Liquids Handling domestic raw sewage Intermittent Liquid, 'temp. up to 140° F up to 60° C Winding Insulation Temp. (Class 3) 266°F 130°C Motor Electrical Data (Single phase motors are capacitor an type. Myers control panels or capacitor ldt3 orc recommended for proper oparalson and warranty.) 2 IR 3450 RPM 1 ph - capacitor start/run 208 Or 230 volt: 60 Hz 3 ph- Induction run 200, 230, 460, 575 volts, 60 Hz Third Party Approvals' CSA, UL cUL Acceptable pH Range 6 - 9 Specific Gravity .9 - 1,1 Viscosity 28 - 35 5SU Discharge, NPT 11/4 in. ' Min. Sump Diameter ' Simplex Duplex 24 in. 61.0 cm 36 in. 91.4 cm Note: Consult factory for applications outside of these reaommendattoris. • Models with Third party approvals) are claarlymcxrked on tndlvidual pump narnenlates, Construction Materials Motor Housing. Seal Housing, Cord Cap, Volute Case. Recessed Impeller cast iron, Class 30, ASTM A4B-76 Power Cord w/seal probe w/o sea) probe 15' 1415 SOW/50W A I5' 14/4 SOWISOW A . Mechanical Seals - Std, Opt. dbi, tandem carbon & cercmlic tungsten carbide Pump. Motor Shaft 416 SST Fasteners ' 300 Series SST Shredding Ring, Grinder Impeller • 440 SST, 58-60 Rockwell - • TNIIERE INNOVATION MEETS TRADITIOI Received Time MaY.23. 5:05PM rso 9001 certified Myers8 Pentair Pwnp Group SON COUNTY PUB C WORKS 'hristie L. Putnam, P.E., Interim Director July 25, 2005 Mr. Michael Lash. Lash Engineering 1226 Mann. Drive Suite 100 Matthews, N.C. 28105 Re: Sewer Treatment Capacity Lot 1-A Prescot Subdivision Vp C'2-9 / Dear Mr. Lash: Union County Public Works Department can accept the additional discharge of 360 gallons per day of domestic wastewater from this project for transmission to the Twelve Mile Creek Wastewater Treatment Plant (NPDES permit number NC0085359) for treatment. This allocation is intended to serve the above mentioned project. Due to modification of the previous permit # WQ0028622, dated 3-24-05 of deleting one lot, we will accept. the 360 gallons per day for lot 1-A. If you have any questions please don't hesitate to call me at (704) 296-4212 or Peter Brown at (704) 296-4224. y: Christie Putnam Interim ctor of Public Works J CD/pwb ce: Terry Predzirnirsl i (Prescot Development, I*LC) - Via ftt (704) 377-4496 40Ci North Church St. • Monroe, North Carolina 28112-4804 • Phone: (704)296-4210 • Fax: (704)296-4232 UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Prescot, Lot 1A We are sending you: TRANSMITTAL Date: 7/27/05 ® Copy of letter ❑ Plans ❑ Prints ❑ Shop Drawings ® Other Copies Date No. Description 1 5/25/05 Original Non Discharge Permit Application r,.. EIEPT. OF EPl ; ice,::.;"ay, 1 5/25/05 Copy of Non Discharge Permit ApplicatiotOa NATURAL RESOURCES .. 1 7/13/05 5334 "CORESVIVA . AL OFFICE Check for $400.00 (Application Fee) . r:7'4 ,r _, 2 6/7/05 Pump Station Calculations . 1 7/25/05 Flow Acceptance Letter JUL 2 9 200:i { 7 1 MITY SECTION These are transmitted as checked below: ® For approval ❑ For your use ❑ As requested ❑ For review and comments Remarks: Signed: Received by: Date: WAT, Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality June 4, 2007 Union County Public Works 400 N. Church Street Monroe, North Carolina 28112 SUBJECT: Prescot Subdivision Log Cabin Permit No. WQ00291 61 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on May 25, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from httD://h2o.enr.state.nc.us/ndpu/ndpuaops.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, t(r,\Robert Krebs '` Surface Water Protection Regional Supervisor Enclosure Cc: Craig Blythe Surface Water Protection Section Central Files (certification page only) Please forward copy to Engineer One Pretreatment, Emergency Response and Collection Systems Unit Internet http:/lh2o.enr.nc.state.us/ndpu NorthCarolina 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Naturally Telephone (919) 733-5083 Fax (919) 733-0059 50%recycled/10%post-consumer paper plr: Fa t Track E Ce ificOon Union County PC Box 400 North. Church Street Monroe, NC 28112 Permit No. Cornplete and submit this form to the perrrif issuiing regional offico with he folio One copy of the project record drawinsgs (ph n & profile view system extension er lines) of the wastewater collection Supporting design calculations (selected pumps, system curve, of s erating point, available storage if portable ggerierator(s) or° storage greater than longest past three year outage reliability option selected) for any pump stations perrnitted as part of this project Changes to the project should be clearly identified on' the record drawings or in wrrtten sur°rrmary for`ro. Permit r r fi atons are required. for any changes resulting in no compliance with th permit, re lati rrr r rrainirrrurr desittr°r criteria. I, Craig S. Blythe ENCIt IFK'A�f ON Par-tiai LI Final as a duly registered Professional Engineer ire the State of North Carotin having been authorized to observe (N periodically, [] weekly, Lj full time) the construction of ff a Union County project for the Permthee, hereby state that to the best of my abilities„ due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials North Car'°otina Professional Engineer's seam signature, and date: SEND THIS FORM & SUP TM ORTI''G llOCUMENTATION WITH RE Ul':' ED ATTACH ENTS TO THE Fs LLOWING ADDRESS RESS MOORESVILL dfEGIONAL OFFICE SUFACE ' ATu.':R'ROTECTION 610 EAST C NTER AVENUE, SUITE 301 MO ^ "ESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final cerUticatioir is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: Mooresville Regional Office Water Quality 610 East Center Ave. Suite 301 Mooresville NC 28115 Attention: Dee Browder TRANSMITTAL Date: 5/24/07 Regarding: Record Drawings and Engineer's Certification for Sewer to serve Prescot Subdivision Lot 1-A (Final Certification) We are sending you:. Copies Date Copy of letter Plans I- Prints L Shop Drawings Other No. Description 5l'23/07 Record Drawings 5/21/07 Engineers Certification for Sewer (WQ0029161) These are transmitted as checked below: © For approval For your use ^1 As requested Li For review and comments Remarks: .... ......... Signed. Received by: Date: