Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0029005_Regional Office Historical File Pre 2018
Michael F. Easley. Governor William G. Ross Jr.. Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek. P.E. Director Division of Water Quality June 30, 2005 Dr. Jerry Thomas, Superintendent Union County Public Schools 500 North Main Street, Suite 700 Monroe, North Carolina 28112 Subject: Permit No. WQ0029005 Union County Public Schools Waxhaw/ Marvin Elementary School Wastewater Collection System Extension Union County, North Carolina Dear Dr. Thomas: In accordance with your application received .on June 16, 2005, we are forwarding herewith Permit No. WQ0029005, dated June 30, 2005, to Union County Public Schools for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-60-40 Internet h2o.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 59% Recycled/10% Post Consumer Paper NorthCarolin A1aturallb Dr. Jerry Thomas Page 2 June 30, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Schools for the construction and operation of approximately 127 linear feet of 6-inch gravity sewer, and approximately 410 linear feet of 8-inch gravity sewer to serve 800 students as part of the Waxhaw/ Marvin Elementary School project, and the discharge of 9,600 gallons per day of collected domestic wastewater into Union County's existing sewerage system, pursuant to the application received June 16, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County Twelve Mile Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between Union County Public Schools and Union County for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or [imitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Union County Health Department Mooresville Regional Office, Surface Water Protection (WVITT'F Permit No. NC0085359) Charles Powell, Davis -Martin -Powell and Associates Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not. required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once_per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. 'Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Fast Track Engineering Certification Permit No. WQ0029005 June 30, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Waxhaw/ Marvin Elementary School, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE • SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. APPLICATION for GRA'i'f"I lr' SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD? Owner: Union County Public Schools Full Legal Name (company, municipality, HOA, utility, etc z lb, Dr. Jerry W.Thomas„Superintendent Union County Schools © Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials. The legal entity who will own this system is: ndividual ❑ Federal ❑ Municipality State/County ❑ Private Partnership ❑ Corporation 1 Other (specify). School; Application Number: (to be completed by MVO) vv. 0 Id. 500 North Main Street, Suite 700 Street Address North Carolina State 0 z z 1 h. 704-283-3733 1 i. 704-289-156 Telephone Facsimile 2. Project (Facility) Information: 2a. Waxhaw/Marvin Elementary School Brief Project Name (permit will refer to this name Contact Person: Eddie MacEldowney, Project Manager Monroe City lg. -281124786 Zip Code E- 2b. Union County here Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, 336-886-4821 Phone Number New ❑ Modification ner is ❑ Public (skip to Item B f private, applicant will be: n existing permit) { Private (g 3c, emac@dmp-iin .cam E-mail If Modification, Permit No,: to 2b. If sold, facilities owned by a (must choose one Retaining Ownership (Le. store„ church, single office,, etc.) or 0 Public Utility (instruction. Ill) 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc /Developer(lnstruction IV) ❑ Selling units (lots, townhomes, etc, - go to Item B(2b)) Union County Public Works Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, Twelve Mile Creek Water Reclamation Facility Name of WWTF 4b. NC0085359 WWTF Permit No, 5a, Union County Public Works 5'b. _'Sc, WQ0028606 Owner of Downstream Sewer Receiving Sewer Size Permit Number o The origin of this wastewater is (check all that apply): Residential Subdivision ❑ Apartments/Condominiums Mobile Home Park School ❑ Restaurant El Office Car Wash ❑ Institution ❑ Hospital 0 Church 0 Nursing Home 0 Other (specify): Volume of wastewater to be permitted in this project: 9600 gallons per day ewer ('if known 100 % Domestic/Commercial % Industrial % Other (specify): 8, If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected ETA 022/03 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 i I i Q UJ n Z Z O 0 ' Z Q11. M 0 LL Zi H CC w a.__...__ m 9. Provide the wastewater flow calculations .0219(1) for Item B(7) or the design flow for that in 15A NCAC 2H .0219(I)(1-2) must the Division of Water Quality, Non -Discharge accordance with 15A NCAC 2H .0219(I)(3). used line be in determining the permitted flow in accordance with 15A NCAC 2H or pump station sizing if zero flow in the space below. Values other than approved prior to submittal of this application. Submit a separate request to Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in 800 student capacity multiplied by 12 gallon per day per student y 1(0,0 1,0 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (pull down menu) 6 127 Gravity 8 410 Gravity Gravity Gravity Gravity Gravity ENTER TOTAL LINE Gravity LENGTH IN MILES • 0.10 J Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (as shown on plans) N/A Design Flow (MGD) - N/A € Power Reliability Option Operational Point (dual line feed, permanent generator w/ATS, GPM @ TDH • portable generator w/telemetry, wet well storage) NIA i N/A ............................_..... -L_ 12. Does the sewer system i Mains (latest version), _ Minimum the - - comply with the Minimum the Gravity Sewer no, please reference is requested: PLANS, SPECIFICATIONS - _...-...............�.._......_...._._.. - ---.._._.._ ._...-.._.__-., _...._.__. Design Criteria for the Fast Track Permitting of Pump Stations and Force Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? pertinent minimum design criteria or regulation and indicate why a OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION CA Yes ❑ No If i variance SUSMIT TWO COPIES OF 13. Have the following permits/certifications been Wetland/Stream Crossings - General Permit Sedimentation and Erosion Control Plan? Stormwater? submitted for approval? or 401 Certification? ® Yes ■ No • N/A ►i Yes • No • N/A ® Yes ❑ No • N/A FTA 02/03 z z APPLICATION for GRAVIT\' SEWERS, PUMP STATIONS, AN FORCE "IAINS PAGE 5 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/0 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as! necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OP indicate the following: 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map 1 Name of Waterbody Stream Waterbody Waterbody County River Basin index Classification Cowhom Branch Union Catawba 11-138-1-3-6-1 C Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided!; Applicant's Certification; 1, Dr, Jerry W Thomas, attest that this application for Waxhaw/Marvin Elementary School has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, ar' certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 es well as civil penalties up to $25, g per violation. gnin loci ignatu 2. Profes anal ttineer's Certification; ` L4- Date ! attest that this application for Waxhaw/Marvin Elementary School has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a .fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a, Cherie s E. Po Professional Engineer Name 2b, Davis -Martin -Powell and Associates Engineering Firm 2c, 6415 Old Plank Road Address 2d, High Point City 2e, NC State 27265 Zip 2g. 336-886-4821 2h, 336-88fi t45t3 2i, dmp@dam_inc.com Telephone Facsimile E-mail Seal, Signature E FTA 02I03 TopoZone - The Web's `i"opo raplue Map, and more" GET DATA Photo inf Topo Downloadv Photo Download USGSryTopoT Map .r� Series nK S 1 a 250K Series Map Size SrriaH M'ediu' 1 Y 24,000 Update Ma Coordinate Format DD MM MM Coardfnate,Datum WVGS84(NAp83 E~'J Show target Email this snap ark this map nt thl (D Alt " Fr OPOZONE VICES 34° 58,12'N, 80° 48.02'WW (WGS84/NAD83) tJSGS Catawba NE Quad View TopoZone Pro aerial photos, shaded relief, street maps, interactive coordinate display, and elevation data hap.I.^ topozone.convin ABOUT Us 8Ca° 576&e 51 K226& , 24&size' Ie I of 1 11'; a 3;52 PM Permit Number W00029005 Program Category Non -discharge Central Files: APS_ SWP 06/28/05 Permit Tracking Slip Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.basinger Permitted Flow 9600 Facility Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Waxhaw/ Marvin Elementary School Location Address Owner Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Public Schools Dates/Events Owner Type Government - County Owner Affiliation Jerry Thomas 500 N Main St Ste 8 Monroe NC 28112 scheduled ()rig Issue App Received Draft Initiated Issuance 06/16/05 Regulated Activities Public Notice Issue Effective b/3o1/4d S' RequestedlReceived Events School Wastewater collection Outfall NULL Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS DEPARTMENT Jon C. Dyer, P.E., Director April 28, 2005 Charles E. Powell Davis -Martin -Powell and Associates 6415 Old Plank Rd. High Point N.C. 27265 Re: Sewer Treatment Capacity Waxaw/Marvin Elementary School Dear Mr. Powell Union County Public Works Department can accept the additional discharge of 9600 gallons per day of domestic wastewater from this project for transmission to the Twelve Mile Creek Wastewater Treatment PIant (NPDES permit number NC0085359) for treatment. This allocation is intended to serve the above mentioned project. If you have any questions please don't hesitate to call. Sincerely: n C. Dyer Director of P. blic Works JCD/ing cc: Dr. Jerry W. Thomas -Superintendent Union County Schools 400 North Church St. . Monroe, North Carolina 28112-4804 . Phone: (704) 296-4210 . Fax: (704) 296-4232