Loading...
HomeMy WebLinkAboutWQ0028606_Regional Office Historical File Pre 2018 (3)Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Deportment of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality March 23, 2005 Mr. Jon Dyer, Public Works Director Union County 400 North Church Street Monroe, North Carolina 28112 Subject: Permit No. WQ0028606 Union County Tarkill Branch Pump station, Outfall and Forcemain Wastewater Collection System Extension Union County, North Carolina Dear Mr. Dyer: In accordance with your application received on March 8, 2005, we are forwarding herewith Permit No. WQ0028606, dated March 23, 2005, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. This project also includes the abandonment of an existing 250-gpm pump station (Permit No. WQ0018381) and the construction a 705-gpm pump station at the state line. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Pax: (704) 663-6040 Internet h2o.enr.slate.nc.us Customer Service: 1-877-623-6748 An Equal opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper NorthCarolina Naturally Mr. An Dyer Page 2 • March 23, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County for the construction and operation of approximately 82 linear feet of 8-inch gravity sewer, approximately 4,446 linear feet of 12-inch gravity sewer, approximately 10 linear feet of 16-inch gravity sewer, and approximately 1,640 linear feet of 21-inch gravity sewer; a 705-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, and a on -site generator with automatic transfer switch; and approximately 3,862 linear feet of 12-inch force main to serve as an interceptor line as part of the Tarkill Branch Pump Station, ©utfall and Forcemain project, with no additional discharge of collected domestic wastewater (flow will be permitted in subsequent permits that connect to this line) into Union County's existing sewerage system, pursuant to the application received March 8, 2005, and in conformity with 15A NCAC 2H ,0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County Twelve Mile Creek'WVVTP (NPDES No, NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1503 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699, Sincerely, for Alan W. Klimek, P.E. cc: Union County Health Department Mooresville Regional Office, Surface Water Protection (tWfTF Permit No. NC0085359) Jay Banks, McKim and Creed Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains .adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective .only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual, system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual _permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the' groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 1'5A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H _0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action; including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or, ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 23`t day of March, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klime[4, P.E. Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0028606 3 Fait Track Engineering Certification Permit No. WQ0028606 March 23, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial El Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (E periodically, ❑ weekly, ❑ full time) the construction of the Tarkill Branch Pump Station, Outfall and Forcemain, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. APPLICATION for GRAVITY SEVERS, PUN P STATIONS, AND PAGE z USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner, la. Union Count Deaaartment of Public Works Full Legal Name (company, municipality, HOA, utility, etc.) Application Number. ,to be completed by DWQ) 1tV f Public Works 1b� Jon C. Dyer PE Director,Union Coui� Department ofr.._w.. m.._...___ .�...m u..__ Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: 0 Individual 0 Federal (] Municipality State/County El Private Partnership [1' Corporation I ' Other (specify)° ld. 400 North Church Street Street Address 11 NC State l h. 704-296-4210 1 i. 704 296 4232. Telephone Facsimile _.._..._ 2„ Project (Facility) inform f)on. 1 e. Monroe tt.__.... City l g. 28112-4804 Zip Code fond er cn union nc us Email 2a Tarkill Branch Pump Station, Outfatt; and Forcemain 2b. Union County Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: 3a. Charlie O Cain, PE, De ii y Direct Name and Affiliation of Someone 3b. 704-296-4210 Phone Number ho Can Answer Questions About this .Application 3c, a'cain o.union.nc.us 1 Project is NJ New 0 Modification (of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (i„e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2, Owner is DI Public (skip to Item B(3)) L] Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose „n 0 Retaining Ownership (i.e. store, church, single office, etc) or O Leasing units (lots, townhomes, etc. - skip to Item B(3)) O Selling units (lots, townhomes, etc. - go to Stem B(2b)) 3, Union Count' Owner of Wastewater Treatment Fa Mile Creek WWTP Name of WWTF _w Union County Owner of Downstream Sewer The origin of this wastewater is Ej Residential Subdivision 0 Apartments/Condominiums (] Mobile Home Park School E Restaurant 0 Office 0 Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) colity (W W F) Treating Wastewater From This Project 4b. NC0085359 WVVTF Permit No. 5b. 10FORC E MAIN 5c. WQ0018381 Receiving Sewer Size i Permit Number of Downstream Sewer (if known heck all that apply): 0 Car Wash 0 Institution 0 Hospital • Church O Nursing Horne O Other (specify):.. 7. Volume of wastewater tobepermitted in this project: 0 gallons per day 8 If the permitted flow is zero, indicate why: Q Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flaw has already been allocated in Permit No, El Rehabilitation or replacement of existing sewer with no new flow expected Domestic1Coan mercia l % Industrial `'/o Other (specify): 02./03 - Rev,. 1 06/0:3 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 pir 0 W 0 Z F— Z 0 0 Z 0 Q11. Ce 0 IL Z 1-- E cc W E" m 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). fiNz' Qcul'e6 r oG 1774 6rSr7N PUn"t p Si-741 SY_ � N , T7 S PRa .S. cT ,s Tr.' 0E-to (wtgoa/ 3 es j , g-',7 � isim ,sf, a hi 8v/ cp R- //c'w (attach f G/"J _gazzi_lo 10. Summary of Sewer Lines to be Permitted _. additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 21 1,640 Gravity 16 10 Gravity l 12 4,446 Gravity , 8 82 Gravity 12 3,862 Force Main ENTER TOTAL LINE LENGTH IN MILES 1.90 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on L_plans for cross-reference) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (1- dual line feed; 2- permanent generator wIATS; 3- portable generator wltelemetry; 4-wet well storage) Tarkill Branch 0.864 705 @ 151' 2- Permanent Generator 12. Does the sewer system comply Mains (latest version), the with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? reference the pertinent minimum design criteria or regulation and indicate why a is requested: SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION • Yes ■ No If no, please variance SUBMIT TWO COPIES OF PLANS, 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? 0 Yes ® No • N/A 0 Yes ❑ No • NIA >> • NIA 0 Yes ■ No FTA 02/03 - Rev. 1 06/03 FPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 C. STREAM CLASSIFICATION-1 Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as ry). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: D A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, ❑ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on ma_ p for cross-reference) Name of Waterbody County River Basin Waterbody Stream Index Waterbody Classification See Attached Tarkill Branch Union Catawba 11-138-3-6 C See Attached Cowhorn Branch Union Catawba 11-138-3-6-1 C r— • Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Z 0 1— Q U LL 1— • cc W 0 CI 1. Applicant's Certification: 1, Jon C Dyer, PE, attest been reviewed by me of this application are this application package Statutes 143-215.6A certification in any application ell as ci 1 penalties that this application for Tarkill Branch Pump Station Duffel! and is accurate and complete to the best of my knowledge. not completed and that if all required supporting documentation is subject to being returned as incomplete. Note: In accordance and 143-215.6B, any person who knowingly makes any false sh 1 be guilty of a Class 2 misdemeanor which may up t ,000 per violation. i .4 Sewer and Forcemain Sewer has 1 understand that if all required parts and attachments are not included, with North Carolina General statement, representation, or include a fine not to exceed $10,000 1a. -._. SS- d L Signing ici 1 Signature ate by me these with _ 2. Professi n Engineer's Certification: 1 attest that this application for Tarkill Branch Pump Station Outfal! Sewer and Forcemain Sewer has been reviewed and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. ! further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. JAY D. BANKS, PE S.t GAR ittimi'��110i `.`Q,vo ....... 17iv e,,0z., : Z�' O�� �9 - : a SEAL OS IProfessional Engineer Name �2b. McKim & Creed Engineering Firm 2c. 8020 Tower Point Drive . + �•'• ..G.N-' �� �• 0.. tjA D.13PC;.`••� ,111.11f11110 3I Seal, Signature & Date Address 2d. Charlotte 2e. NC 2f. 28227 City ! State 1 Zip r1:• 2g. 704-841-2588 ,2h. 704-8412567 �2i. jbanks@mckimcreed.com Telephone I Facsimile E-mail FTA 02/03 - Rev. 1 06/03 Name: CATWBA NE Date: 3/3/2005 Scale: 1 inch equals 2000 feet Location: 034° 58` 05,0 N 080 48' 13,9" WV Caption: Tarkill Branch Gravity Sewer, Pump Station, and Forcemain Aaptech, {nc: Central Files: APS_ SWP 03/22/05 Permit Number WQ0028606 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.basinger Permitted Flow 0 Facility Fast Track Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Tarkill Branch Pump Station, Outfall and Forcemain Location Address Owner Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affiliation John Dyer 400 N Church St , Monroe NC 28111 Scheduled Orig Issue App Received Draft Initiated Issuance 03/08/05 Regulated Activities Public Notice Issue School Subdivision Wastewater collection Outfall NULL Effective D3/23hp5 Requested/Received Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/2.96-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, N.C. 2.8115 Attention: Regarding: Tarkill Sr We are sending you: Copies Date 1 3/4/05 1 3/4/05 2/16/05 nch Pump Station, Out -Fall and Forcemain 0 Copy of letter Other No. 4007 TRANSMITTAL 4 Plans 1 Prints El Shop Drawings Description Original Non Discharge Permit Application Copy of Non Discharge Permit Application Check for $400.00 (Application Fee) These are transmitted as checked below: For approval P For your use U As requested 0 For review and comments Remarks: Sig Received by: Date: NEON COUN Y PUBLIC WORKS I. Putnam, P.E., ,)ire August 1, 2007 Ms. Dee Bro °der NCDENR Mooresville Regional Office 610 East Center Ave, Suite 301 Mooresville, NC 281.15 Re: Modification of Pern WQ0030479 Sandy Ridge Elementary School Transfer of flow from 12 Mile WWTP to McAlpine WWTP Via TarKill Branch Pump Station '# WQ0028606 Dear Ms. Browde Union County Public. Works Department wishes to modify- the above mentioned Permit he 12 Mile WWTP (NC 0085359) to McAlpine WWTP (NC0024970),. Per your previous Lions, we are sending Flow Acceptance Letters for the above mentioned permit to be transferred. If you have any questions please don°t hesitate to call me at 704-296-421.4. a, P.E. Public Works Director led 500 North Main St. Suite 500 • Monroe, NC 281.12-4730 • Phone: (704)296-4210 • Fax: (704)296-4232 CHARLOTTE,.. CHARLOTTE-MECKLENBURG UTILITIES July 27, 2007 Mr. Peter Brown Union County Public Works 400 North Church Street Monroe, NC 28112-4804 SUBJECT: SANDY RIDGE ELEMENTARY SCHOOL UNION COUNTY TAX PARCEL# 06-210-003A C-MU TRACKING# 600-07-638 Dear Mr, Brown: In response to your request, a flow acceptance study of the subject site has been completed and it has been determined: Charlotte -Mecklenburg Utilities (C-MU) agrees to accept the sewage flow of 1,800 gallons per day (150 students x 10 god/student; cafeteria; no gym) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment, This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whichever might have control. Please see attached basin map. C-MU does not expect any of the above conditions to preclude sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MU system is accepted on a first come, first served basis. This letter expires one year from the issued date. If you have any questions, please contact me at (704) 391-5129. Sincerely, 62, Barbara Gross Engineering Assistant New Services Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section www.cmutilities.com 00 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 ard Creek WWTP unA�ounty Site C,4u 600-07-638 Charlotte- 14 ecklenburg Utilites WWTP Service Areas with Basins