Loading...
HomeMy WebLinkAboutNC0084662_BIMS Report_20220203ROY COOPER. Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Mr. Greg Simpson, Textron, Inc. c/o Nick Shore, P.G. AECOM Technical Services of NC, Inc. 5438 Wade Park Blvd., Suite 200 Raleigh, North Carolina 27607 Dear Mr. Simpson: NORTH CAROLINA Environmental Quality February 3, 2022 Subject: Compliance Evaluation Inspection Permit No. NC0084662 Former Homelite/ John Deer 3800 Little Mountain Road Gaston County Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject facility on January 28, 2022. The MRO would like to thank Mr. Jon Wakeman of AECOM Technical Services for his assistance during the site visit. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Edward Watson at (704) 235-2199 or at edward.watson@ncdenr.gov. Sincerely, DocuSigned by: FA4• w H P:ue4 F161FB69A2D84A3... Andrew H. Pitner, P.G., Assistant Regional Supervisor Mooresville Regional Office Water Quality Regional Operations Section Division of Water Resources, NCDEQ Attachment: BIMS Inspection Report CC: WQROS Mooresville Regional Office & NPDES (Laserfiche) Jon Wakeman, AECOM (via email) Nick Shore, P.G., AECOM (via email) NO 1:1E n.n.m.enn of e..iron.Mn.i mwitv North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 INI 2 21IIIIII Code I L NPDES yr/mo/day Inspection I 3 I NC0084662 111 121 22/01/28 117 Type 18 1 IIIIIIIII1I Inspector Fac Type 191 S I 201 IIIIIIIIIIIIIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I1.0 I 70I3 I 711D I 72 I N I 73I I 74 751 I I 1 1 1 1 1 1 1 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Textron remediation site Little Mtn Rd Gastonia NC 28053 Entry Time/Date 10:OOAM 22/01/28 Permit Effective Date 21/03/01 Exit Time/Date 11:45AM 22/01/28 Permit Expiration Date 25/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Jon Steven Wakeman/ORC/828-329-6975/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Christopher Milici,40 Westminister St Providence RI 029032596/Manager EHS/401-457-3576/4014576028 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Edward WatspEl— of Inspector(s) Agency/Office/Phone and Fax Numbers Date Docusignedby: DWR/MRO WQ/ - - / 2/2/2022 "—CA4CEBF8F85F415... Signature of Mana emeniciftree?ewer Agency/Office/Phone and Fax Numbers Date 1444414w H P'r,.ue4 2 . 3. 22 "—F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day NC0084662 111 121 22/01/28 I17 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On January 28, 2022, MRO staff performed a Compliance Evaluation Inspection for permit NC0084662 at the Textron facility in Gastonia, N.C. The treatment system is as described in the permit. Laboratory analytical data were reviewed for the period of June 2021 through December 2021. The facility continues to pass Chronic Toxicity testing. The MRO would appreciate it if we could receive a copy of the 2021 Annual Report for the treatment system as a part of the review process. Page# 2 Permit: NC0084662 Inspection Date: 01/28/2022 Owner - Facility: Textron remediation site Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El • ❑ application? Is the facility as described in the permit? • El El El # Are there any special conditions for the permit? El • El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • El El El Comment: A copy of the NPDES permit was provided to the consultant by MRO staff during the site visit. The permit expiration date is 08/31/2025. The system is in an isolated area of the property. Access to the treatment system is restricted by the public. Access is also limted to workers at the facility. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • El ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Very few settlable sediments enter the treatment system. However, 50-micron bag filters are still employed to prevent solids from entering the Air Stripper. MRO Staff reviewed the O&M records from January 2021 through January 2022. The records appear to be complete and in order. The effluent flow meter for the system was calibrated just before MRO staff arrived for the inspection. The calibration records were observed by MRO staff during the Compliance Inspection. The facility outfall has been relocated since the last site visit in 2018 due to erosion at the old outfall. The new outfall location is within approximately 25 feet of the old outfall. No foam, solids, color, or odor was observed at the outfall. Page# 3