Loading...
HomeMy WebLinkAboutSW1210802_Plansheet - Grading_Drainage Plan_20210818DocuSign Envelope ID: A25BD9EC-97B2-4928-B7AB-80136C85AF84 N 0 N I- 0 w 0 a w (n Q 0 I- z J 0 U ry r w 0 0 STORMWATER STRUCTURE CHART 7 U (n 2 �w 0 Sw 7 U U)o 1 1 2083.00 2080.00 3.00 CB 2 2083.61 2079.64 3.97 CB 3 2084.00 2079.04 4.96 CB 4 2084.42 2077.92 6.50 CB 5 2083.39 2077.14 6.25 CB 6 1 2083.59 2079.59 4.00 CB 7 2085.23 2078.48 6.75 J M H 8 2083.39 2077.10 6.30 CB 9 2077.00 2077.00 0.00 PIPE 10 2076.50 1 2072.35 1 4.15 OCS 11 2072.23 1 2072.23 1 0.00 PIPE ABBREVIATION LEGEND CB = CATCH BASIN JMH = JUNCTION MANHOLE OCS = OUTLET CONTROL STRUCTURE PROPOSED DOMESTIC WATER SERVICE, (SEE UTILITY SERVICE PLANS FOR DETAILS) STORMWATER PIPE CHART c E L N EI N� ate+ N� L •� N E LU � LU .01 CN _co(n c dQ_ � 0 (n J (n 2 , A 1 2 72.00 0.50% HDPE 15 B 2 3 119.68 0.50% HDPE 15 C 3 4 224.84 0.50% HDPE 15 D 4 5 155.32 0.50% HDPE 18 E 5 8 9.00 0.50% HDPE 18 F 6 1 7 110.99 1.00%1 HDPE 15 G 7 8 190.30 1.25% HDPE 15 H 8 9 19.03 0.50% RCP 24 1 10 11 24.09 0.50% RCP 24 J) PROPOSED FIRE WATER SERVICE I I (SEE UTILITY SERVICE PLAN FOR DETAILS) I y 3 ti GENERAL STORMWATER NOTES: 1.) ALL STORMWATER PIPES SHALL BE HDPE WITH SMOOTH INTERIOR WALL, WITH BELL AND SPIGOT ENDS AND SOIL TIGHT JOINTS, UNLESS OTHERWISE NOTED ON PLANS. 2.) ALL PENETRATIONS INTO STORMWATER STRUCTURES SHALL BE REPAIRED PROPERLY INSIDE AND OUTSIDE WITH BRICK AND OR NON -SHRINK GROUT. / 3.) GIVEN PIPE LENGTHS ARE BASED ON HORIZONTAL DISTANCES // BETWEEN STORMWATER STRUCTURES. CONTRACTOR SHALL FACTOR IN SLOPES WHEN ORDERING PIPE AND ORDER ADDITIONAL LENGTH AS NECESSARY. ?�(MAY 5. ALL ROOF LEADERS SHALL BE 8" HDPE SMOOTH INTERIOR WALL BE PVC/SCH-40) WITH 1.0% MIN SLOPE UNLESS OTHERWISE NOTED ON PLANS. 6.) CONTRACTOR TO ENSURE THAT ALL EXISTING AND PROPOSED STORM DRAINAGE STRUCTURES, PIPES AND GRADES WILL PROVIDE POSITIVE DRAINAGE PRIOR TO INSTALLATION. 7.) ALL DRAINAGE STRUCTURES GREATER THAN 4' IN DEPTH SHALL / HAVE ACCESS TO STEPS INSTALLED 16" ON CENTER. v 8.) ALL PRECAST "WAFFLE BOX" STORM DRAINAGE STRUCTURES TO HAVE A MAXIMUM DEPTH OF 6'. Z� PROPOSED STORMWATER STRUCTURE (TYP) 2080 2084 0 PROPOSED STORMWATER PIPE (TYP) ■ ■ ■ ■ ■ ■ 12086 rn �` ■ ■ ■ I � ■ i D ■ c/) PROPOSED BUILDING ■ (FFE 2087t) ■ ■ ■ ■ ■ ■ PR LEA �I (SE 8" 11 F01 4" 11 11 R r I L' ■ N_ 8" SSv SSv - SSv 0 -SSv -SSv MIN ■ ■ Now ■ ■ 1p PROPOSED GRAVITY SEWER SERVICE (TYP) (SEE UTILITY SERVICE PLAN FOR DETAILS) 1 FULL SHEET REVISION LEGEND ■ PROPOSED STORMWATER STRUCTURE PROPOSED STORMWATER PIPE PROPOSED SLOTTED UNDERDRAIN SSv PROPOSED GRAVITY SEWER SERVICE SS PROPOSED GRAVITY SEWER EXTENSION (BY OTHERS) - - - - - - - - PROPOSED DOMESTIC WATER SERVICE - PROPOSED FIRE WATER SERVICE W PROPOSED WATERLINE EXTENSION (BY OTHERS) _ 2084/ 2p80 PROPOSED 2' CONTOURS (TYP) EXISTING 2' CONTOURS (TYP) I 0 EXISTING 100' HIGH DENSITY STREAM BUFFER 6;1 WGLA ENGINEERING, PLLC 724 5th AVENUE WEST HENDERSONVILLE, NC 28739 (828) 687-7177 WGLA.COM NC LICENSE P-1342 PROPOSED CAPPED CLEANOUT W/ P107 COVER FLUSH W/ GROUND (TYP) BERM ELEV: 2080.00' II I I I I I I PROPOSED 6" I I PVC/SCH-40 I SLOTTED UNDERDRAIN I(TYP) a I I 10 /, w PROPOSED PERM NENT DRAINAGE SWAL (SEE DETAIL FOR IMENS NS) I BOTTOM ELEV: 2077.00' PROPOSED BIO RETENTION CELL (SEE SHEET C-401 FOR DETAILS) GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) A NEW FACILITY FOR PARDEE PARTNERS ASC (T.B.D.) BOYLSTON HWY MILLS RIVER, NC 28759 CASSET7"Y J. CLINTON CASSETTY ARCHITECT ��N CA/��''%% O oFESS�/,3 oo SEAL oo = o oo 041349 = o o %9� N� I NEB O0�v?�; L. DERV CASSE7TY 100 Country Club Dr., Suite 206 Hendersonville, TN 37075 (615) 822-5711 www.cassettyarch.com THIS DRAWING AND DOCUMENT CONTAINS INFORMATION PROPRIETARY TO THE ARCHITECT. THE REPRODUCTION, COPY OR USE OF THIS DRAWING AND DOCUMENT WITHOUT THE WRITTEN CONSENT IS PROHIBITED AND ANY INFRINGEMENT WILL BE SUBJECT TO LEGAL ACTION. ALL RIGHTS RESERVED. COPYRIGHT 2021. ORIG. ISSUE DATE: 05-19-2021 8-10-21 STORM (1) DHSR PROJECT # AS-440 PROJECT NUMBER 2120 STORMWATER MANAGEMENT PLAN C-400