Loading...
HomeMy WebLinkAboutNCC220387_Site Plan or Location Map_20220131SURVEY LEGEND PROPOSED LEGEND BENCHMARK 0 NEW IRON PIPE MANHOLE ® CA TCH BASIN PI POWER PEDESTAL ® CLEAN OUT ¢ POLE HYDRANT DI DROP INLET SANITARY MANHOLE WATER METER • Q ELECTRIC MANHOLE SHRUB WATER VALVE e © GAS MANHOLE _U_ SIGN CLEANOUT pd GAS VALVE QD STORM DRAINAGE MANHOLE INLET ■ ® GAS METER ❑T TELEPHONE PEDESTAL HYDRANT �D TREE TEE I _ O EXIS77NG IRON PIPE O WA TER METER 9 0' BEND ❑ JUNCTION BOX ® WATER MANHOLE 45' BEND E LAMP ® WATER VALVE GUARDRAIL -❑ ❑ CMB MAILBOX (aWELL p MONUMENT 40 COMPUTED POINT STORM PIPE ADJOINER LINE -------------- UTILITY EASEMENT -ESMT- - -ESMT- - - FENCE LINE X X LINE SURVEYED PAVEMENT HATCHING LEGEND OVERHEAD POWER OH OH RAILROAD TRACKS HEAVY DUTY PAVEMENT RIGHT OF WA Y - - - - SANI TAR Y SEWER S S STORM SEWER §B §B LIGHT DUTY PAVEMENT TREE LINE WATER LINE W w CONCRETE °a DEMOLITION LEGEND ' REINFORCED CONCRETE TO BE REMOVED `. d4 TO BE REMOVED EROSION CONTROL LEGEND 3 a_ `1 BETH AVE w O U Z WELSNER ST N U m Mil F eRF�FR S I TE yss� Rp �� HAVERHILL ST m w oz Z > D W m o Z Ull W HARSON T fy- ETHEL DR Q 0 Z O �Q LE W CLEMMONSv1 hN / JGo VICINITY MAP NOT TO SCALE SF TEMPORARY SILT FENCE TEB 30 TEMPORARY EARTH BERM PEB ) PERMANENT EARTH BERM SD TEMPORARY SLOPE DRAIN SHEET INDEX: LIMITS OF DISTURBANCE SITE NOTES, LEGENDS & SHEET INDEX COA EXISTING CONDITIONS & DEMOLITION PLAN C1.1 MATTING MATERIAL SITE PLAN - PHASE 1 C2.1 SITE PLAN - PHASE 2 C2.2 0° TEMPORARY CONSTRUCTION ENTRANCE PAVING PLAN GRADING PLAN C2.3 C3.1 00 UTILITY PLAN C4.1 1 EROSION CONTROL PLAN -PHASE 1 C5.1 ❑ TEMPORARY INLET PROTECTION EROSION CONTROL PLAN -PHASE 2 SKIMMER BASIN DETAIL C5.2 C5.3 STANDARD AND STORM DRAINAGE DETAILS C6.1 cPcb TEMPORARY ROCK CHECK DAM UTILITY DETAILS C6.2 EROSION CONTROL DETAILS C6.3 NCGO1 NOTES AND DETAILS C6.4 C& TEMPORARY ROCK OUTLET OUTLET PROTECTION DOUGHNUT INLET PROTECTION :t iI: :71>I WlME,L01l 1. ALL UTILITY (WATER/SEWER) CONSTRUCTION SHALL CONFORM TO THE CURRENT STANDARDS OF THE CITY OF WINSTON-SALEM. 2. ALL PROPOSED WATER IMPROVEMENTS FROM THE WATER MAIN TO THE WITHIN 5' OF THE BUILDING SHALL BE INSTALLED BY THE GENERAL CONTRACTOR'S UTILITY CONTRACTOR. 3. ALL WATER MATERIAL SHALL BE DUCTILE IRON PIPE. 4. ALL HYDRANTS LOCATIONS SHALL BE COORDINATED WITH THE LOCAL FIRE MARSHALL PRIOR TO INSTALLATION. 5. FIRE LINES SHALL BE INSTALLED BY THE UTILITY CONTRACTOR TO THE INSIDE OF THE BUILDING AND STUBBED UP 1' ABOVE FINISH FLOOR. 6. ALL WATER PIPING SHALL HAVE A MINIMUM COVER OF 36 INCHES. BURIED MAGNETIC WARNING TAPE SHALL BE LOCATED 6" ABOVE THE WATER LINE AND 12" BELOW GRADE. 7. BLUE TRACER WIRE SHALL BE INSTALLED ON ALL WATER LINES OUTSIDE OF BUILDING. 8. ALL SANITARY SEWER PIPE SHALL BE DUCTILE IRON. 9. GENERAL CONTRACTOR SHALL COORDINATE BETWEEN THE UTILITY CONTRACTOR AND THE BUILDING PLUMBING CONTRACTOR ALL INVERT ELEVATIONS AND LOCATIONS PRIOR TO BEGINNING WORK 10. ALL SANITARY SEWER PIPING SHALL HAVE BURIED MAGNETIC WARNING TAPE 6" ABOVE THE PIPE AND 12" BELOW GRADE. 11. MINIMUM SLOPE FOR SANITARY SEWER LATERAL SHALL BE 2% FOR 4" LATERALS AND 1% FOR 6" LATERALS 12. SANITARY SEWER SHALL HAVE CLEANOUTS WITH VERTICAL STACKS TO GRADE AT ALL BENDS AND AT 50' O.0 INTERVALS ON STRAIGHT SECTIONS 13. ALL EXTERIOR ROOF DRAIN/DOWNSPOUT PIPING INDICATED TO BE PIPED, SHALL BE DONE BY THE UTILITY CONTRACTOR. 14. ALL ROOF DRAIN/DOWNSPOUT PIPING SHALL BE SCHEDULE 40 PVC PIPING. SEE PLAN FOR SIZES. 15. ALL ROOF DRAIN/DOWNSPOUT PIPING SHALL HAVE CLEANOUTS WITH VERTICAL STACKS TO GRADE AT ALL BENDS AND AT 75' O.0 INTERVALS ON STRAIGHT SECTIONS. 16. ALL CLEANOUT SHALL BE INSTALLED WITHIN A CONCRETE COLLAR AT GRADE. 17. ANY CLEANOUT LOCATED WITHIN ASPHALT OR CONCRETE AREAS, SHALL BE INSTALLED WITH A BRASS COVER. GENERAL NOTES: 1. OWNER: WINSTON SALEM/ FORSYTH COUNTY BOARD OF EDU. PO BOX 2513 WINSTON SALEM, NC 27102 2. ADDRESS OF SITE 410 HAVERHILL RD WINSTON SALEM, NC 27102 3. PARCEL ID: 6834-10-0678 4. DEED BOOK/PG DB 865 PG 190 5. CURRENT ZONING IP 6. CURRENT USE EDUCATIONAL 7. AREA OF TRACT 56.19t ACRES 8. WATERSHED WS-IV 9. BOUNDARY AND TOPOGRAPHIC INFORMATION TAKEN FROM SURVEY BY OTHERS., SIGNED BY JERRY W. ELLIS (PLS L-4558) ON OCTOBER 10, 2016. 10. THIS PROPERTY IS NOT LOCATED WITHIN A DETAILED FLOOD HAZARD AREA AS SCALED FROM MAPS BY FEMA DATED JANUARY 02, 2009. SEE COMMUNITY PANEL #371068300J. 11. UNDERGROUND UTILITIES WHERE NOT DISCERNABLE BY SURFACE APPURTENANCES (MANHOLES, VALVES, CATCH BASINS, ETC...) ARE SHOWN PER INFORMATION OBTAINED FROM ENGINEERING PLANS, UTILITY ENTITIES, SITE PLANS, AND OTHERS. SIZE AND LOCATIONS SHOULD BE CONSIDERED APPROXIMATE. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES. CONTRACTOR SHALL EXPLORE AHEAD OF ALL WORK TO VERIFY UTILITY LOCATIONS. ANY UTILITIES DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED IMMEDIATELY AT NOT ADDITIONAL COST TO THE OWNER. 13. CONTRACTOR SHALL COORDINATE REMOVAL OF ANY UTILITY WITH THE UTILITY PROVIDER. 14. CONTRACTOR SHALL COORDINATE WITH THE UTILITY PROVIDER ANY NEW SERVICE (ELECTRICAL, GAS, TELEPHONE, SANITARY, ETC...) 15. ALL DEMOLITION MATERIALS SHALL BE REMOVED FROM SITE AND DISPOSED OF IN AN APPROVED CONSTRUCTION DEBRIS LANDFILL. NO MATERIAL WILL BE ALLOWED TO BE BURIED ON SITE. 16. CONTRACTOR SHALL BE REQUIRED TO PROVIDE A SIGNED AND SEALED SURVEY FROM A LICENSED PROFESSIONAL SURVEYOR IN THE STATE OF NORTH CAROLINA AN ASBUILT SURVEY OF: a. WATER LINE, VALVES, BENDS, HYDRANTS, TEES METERS, BACKFLOW PREVENTION DEVICES, b.SEWER LINE MANHOLES, INVERTS, CLEANOUTS c.STORMWATER SYSTEM CATCH BASINS, INVERTS d.STORMWATER BEST MANAGEMENT PRACTICE SUCH AS BIO-RETENTION AREAS AND RETENTION PONDS INCLUDING BUT NOT LIMITED TO TOPOGRAPHIC SURVEY, DETAILED SURVEY OF DRAWDOWN DEVICE. 17. ASBUILT SURVEY WILL BE NEEDED PRIOR TO ANY PARTIAL OR FINAL CERTIFICATIONS FOR WATER, SEWER, OR STORMWATER BEST MANAGEMENT PRACTICE. 18. ALL RETAINING WALLS SHALL BE ENGINEERED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF NORTH CAROLINA. 19. OFFSITE SUITABLE BACKFILL MATERIAL FOR RETAINING WALLS IS CONSIDERED PART OF THE WALL. SHOULD THE CONTRACTOR DESIRE TO USE ONSITE MATERIAL, CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CONFIRMATION WITH A GEOTECHNICAL ENGINEER THAT THE ONSITE MATERIAL MEETS ALL DESIGN CRITERIA/ASSUMPTIONS PER THE DESIGN 20. ALL RETAINING WALLS HIGHER THAN 30" SHALL HAVE A 4' HIGH MINIMUM CHAIN LINK FENCE AT THE TOP OF THE WALL. 21. REQUIRED PARKING (1 SPACE PER 5 STUDENTS BASED ON DESIGN CAPACITY + 1 SPACE FOR EA. FACULTY & STAFF PERSON ON THE LARGEST SHIFT) PROVIDED PARKING SPACES: 92 HANDICAP SPACES: 5 TOTAL SPACES PROVIDED: 97 GENERAL EROSION CONTROL/GRADING NOTES: 1. CONTRACTOR SHALL SET UP A PRE -GRADING MEETING WITH THE ENGINEER, EROSION CONTROL INSPECTOR, GRADING CONTRACTOR AND OWNER PRIOR TO STARTING WORK. THE CONTRACTOR WILL RECEIVE THE GRADING PERMIT AT THIS MEETING. 2. THE EROSION CONTROL INSPECTOR FOR THIS PROJECT IS NCDEQ DEPARTMENT OF LAND QUALITY (336) 776-9800. 3. ALL GRADES REPRESENT THE FINAL GRADE WITH NO ADJUSTMENTS FOR TOPSOIL. 4. ANY TOPSOIL ON SITE SHALL BE STRIPPED AND STOCKPILED FOR FUTURE USE AROUND BUILDINGS, LANDSCAPE ISLANDS ETC. TOPSOIL SHALL BE SCREENED TO REMOVE ROCK AND WOODY DEBRIS PRIOR TO USAGE. THIS SHALL BE INCLUDED IN THE BASE BID. 5. ALL SLOPES SHALL BE SEEDED IMMEDIATELY AFTER REACHING FINAL GRADE. PERIMETER BERMS AND SLOPES 3:1 OR STEEPER SHALL BE SEEDED WITHIN 7 DAYS OF REACHING FINAL GRADE. ALL OTHER SLOPES SHALL BE SEEDED WITHIN 14 DAYS OF REACHING FINAL GRADE. AREAS THAT HAVE BEEN DISTURBED AND WORK IS SUSPENDED IN THAT AREA FOR MORE THAN 14 DAYS SHALL BE SEEDED. INSPECT SLOPES FOR EROSION AND REPAIR BY INSTALLING MATTING MATERIAL ON SLOPES THAT ROUTINELY EXPERIENCE EROSION PROBLEMS PRIOR TO PERMANENT VEGETATION ESTABLISHMENT. 6. EROSION CONTROL MEASURES INDICATED ARE SHOWN IN APPROXIMATE LOCATIONS. SLIGHT FIELD ADJUSTMENTS SHOULD BE EXPECTED TO INSURE SEDIMENT BASINS, BERMS, AND OTHER EROSION CONTROL FEATURES FUNCTION TO MAXIMUM EFFICIENCIES. 7. ALL EROSION CONTROL MATERIALS MUST BE ON SITE PRIOR TO BEGINNING CONSTRUCTION. I.E. BUT NOT LIMITED TO RISER/BARREL, SILT FENCING, ETC. 8. ADDITIONAL EROSION CONTROL MEASURES NOT SHOWN ON THIS PLAN MAY BE REQUIRED TO INSURE NO SEDIMENT LEAVES THE SITE. THE CONTRACTOR IS EXPECTED TO NOTIFY THE ARCHITECT OR ENGINEER IMMEDIATELY IF THEY FEEL ADDITIONAL MEASURES ARE NEEDED. 9. THE CONTRACTOR MUST COMPLY WITH ALL PROVISIONS OF THE NORTH CAROLINA GENERAL STORMWATER PERMIT FOR LAND DISTURBING CONSTRUCTION ACTIVITIES. AS OF MARCH 10, 2003, ALL CONSTRUCTION SITES ONE (1) ACRE OR MORE, REQUIRE A NPDES PERMIT THEREFORE: a. WRITTEN DOCUMENTATION OF A DEVIATION FROM APPROVED PLAN MUST BE NOTED ON THE APPROVED PLANS. b. WRITTEN DOCUMENTATION OF AN EMERGENCY SITUATION WHERE SEDIMENT HAS BEEN DISCHARGED OFF SITE MUST BE RECORDED. ALSO, CONTRACTOR'S ACTIONS TO REPAIR AND RETURN AREA TO PRE -STORM CONDITION MUST BE RECORDED. c. THE CONTRACTOR SHALL INSPECT ALL EROSION AND SEDIMENTATION CONTROL FACILITIES EVERY SEVEN DAYS AND WITHIN 24 HOURS OF A .5 INCH OF RAIN. FINDINGS SHALL BE RECORDED AND PRESENTED UPON INSPECTOR'S REQUEST. d. THE CONTRACTOR SHALL PROVIDE RAIN -RECORDING DEVICE AND RECORD EACH RAINFALL. e. ANY FAILURES THAT CAUSE VISIBLE SEDIMENTATION TO LEAVE THE APPROVED DISTURBED LIMITS SHALL BE CORRECTED IMMEDIATELY AND DOCUMENTED. f. A COPY OF THE NPDES PERMIT SHOULD BE KEPT ON SITE FOR REFERENCE. 10. A NEW SELF -INSPECTION PROGRAM FOR ALL LAND -DISTURBING ACTIVITIES LARGER THAN ONE (1) ACRE BECAME EFFECTIVE OCTOBER 1, 2010 AS PER GS 113A-54.1(E). THIS GENERAL STATUTE DIRECTS ALL PERSONS CONDUCTING LAND -DISTURBING ACTIVITIES LARGER THAN ONE (1) ACRE TO INSPECT THEIR PROJECT AFTER COMPLETING EACH PHASE OF THE PROJECT, AND DOCUMENT THE INSPECTION IN WRITING. A DETAILED EXPLANATION MAY BE VIEWED AT HTTPS: //DEQ.NC.GOV/ABOUT/DIVISIONS/ENERGY-MINERAL- LAN D-RESOURCES/ENERGY-MINERAL- LAND -PERM ITS/STORMWATER-PERMITS/ CONSTRUCTION -SW. 11. AS OF APRIL 1, 2019, REVISIONS WERE MADE TO THE NORTH CAROLINA DIVISION OF WATER QUALITY (DWQ) CONSTRUCTION GENERAL PERMIT (NCGO1). ALL NEW CONSTRUCTION ACTIVITIES HAVING OVER ONE ACRE OF DISTURBED AREA ARE REQUIRED TO COMPLETE AND SUBMIT AN ELECTRONIC NOTICE OF INTENT (NOI) FORM REQUESTING A CERTIFICATE OF COVERAGE (COC) UNDER THE NCGO1 CONSTRUCTION STORMWATER GENERAL PERMIT. THIS FORM MUST BE SUBMITTED PRIOR TO THE COMMENCEMENT OF ANY LAND DISTURBING ACTIVITY. THE eNOI FORM AND INSTRUCTIONS MAY BE ACCESSED AT https: //DEQ.NC.GOV/NCGO1. 12. IF CONTRACTOR DEEMS OFFSITE BORROW OR WASTE IS REQUIRED, THE CONTRACTOR SHALL PROVIDE PROOF THAT THE BORROW/WASTE AREA(S) ARE OPERATING UNDER AN APPROVED EROSION CONTROL PLAN. IF ADJUSTMENTS ARE SUBMITTED AND APPROVED, THE GRADING CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION PRIOR TO ANY CHANGE. THIS SHALL INCLUDE HIS ESTIMATE OF CUT VERSUS FILL AND THE METHOD FOR MOVING DIRT AROUND THE ENTIRE SITE TO THE COMPLETION OF THE PROJECT. 13. GENERAL CONTRACTOR IS RESPONSIBLE FOR INSPECTION/MAINTENANCE AND REPAIR OF ALL EROSION CONTROL MEASURES UNTIL THE PROJECT IS COMPLETE. 14. ALL FILL SLOPES OVER 6' HIGH SHALL HAVE EARTH BERMS AND SLOPE DRAINS INSTALLED AT THE END OF EACH DAY OF GRADING ACTIVITY. AS SLOPES EXTEND UPWARDS, TEMPORARY SLOPE DRAINS ARE TO BE PROVIDED FOR ALL SLOPES GREATER THAN EIGHT FEET HIGH. MAINTAIN BERMS AT THE TOP OF FILL SLOPES TO DIRECT RUN OFF TO SLOPE DRAINS. PERMANENT SLOPE DRAINS INDICATED SHALL BE BURIED WITH A MINIMUM OF 12" OF COVER. 15. CONTRACTOR SHALL EXPLORE FOR ON -SITE MATERIAL TO REPLACE ANY UNSUITABLE MATERIAL ENCOUNTERED. THIS TASK SHALL OCCUR IMMEDIATELY FOLLOWING THE LOGGING OPERATION. THE DESIGNATED GEO-TECH COMPANY WILL PROVIDE ASSISTANCE. 16. TOP SOIL CAN BE STOCKPILED WHERE SHOWN ON PLAN. STOCKPILE WILL REQUIRE SILT FENCES AND BERMS FOR EROSION CONTROL. FIELDS SHALL BE ROUGH GRADED PRIOR TO STOCKPILING. ANY EXCESS SOIL IS THE PROPERTY OF OWNER. SOIL SHALL BE STOCKPILED IN INDICATED AREAS, SEEDED AND SILT FENCE SHALL BE ADDED ON THE LOW SIDE OF THE STOCKPILE. CONFIRM LOCATION OF STOCKPILES WITH OWNER. 17. CONTRACTOR SHALL VERIFY ALL CURBING AND PARKING GRADES MANUALLY PRIOR TO INSTALLATION. ANY ADJUSTMENTS SHALL BE MADE AT THIS TIME TO PROVIDE ADEQUATE DRAINAGE. CONTACT THE SITE ENGINEER IMMEDIATELY FOR RECOMMENDATIONS. 18. CONTRACTOR WILL BE RESPONSIBLE FOR SCARIFYING THE SOIL, AS NECESSARY FOR ADEQUATE USAGE WITH NO ADDITIONAL COST TO THE OWNER. 19. ALL DITCHES GREATER THAN 2% SHALL HAVE EXCELSIOR MATTING INSTALLED. 20. ALL EROSION CONTROL DEVICES ARE TO REMAIN IN PLACE UNTIL SITE IS PROPERLY STABILIZED WITH SUFFICIENT GROUND COVER. GROUND COVER MUST BE MAINTAINED TO A DEGREE THAT PREVENTS SOIL EROSION AND SEDIMENTATION AT ALL TIMES. 21. CONTRACTOR SHALL CALL FOR AN INSPECTION PRIOR TO REMOVING ANY EROSION CONTROL DEVICES. REMOVAL OF EROSION CONTROL DEVICES SHALL OCCUR ONLY UPON RECEIPT OF APPROVAL FROM EROSION CONTROL INSPECTOR. ANY MODIFICATIONS TO THE APPROVED PLANS MUST BE PRE -APPROVED AND DOCUMENTED ON THE SELF -INSPECTION FORMS. 22. AFTER INSPECTION FOR SUFFICIENT GROUND COVER AND THE SITE'S COVER IS APPROVED, CONTRACTOR SHALL REMOVE THE SEDIMENT THAT HAS COLLECTED FROM THE EROSION CONTROL DEVICES AND GRADE THE AREA(S) WHERE THE MEASURES WERE INSTALLED TO FINAL ELEVATIONS AND STABILIZE. 23. ALL EROSION CONTROL MEASURES MUST CONFORM TO THE LATEST STANDARDS FOUND IN THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL OF THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES. AL 25496 c 08/19/2021 FINAL DRAWING Not for Construction For Review/ Approval Only SITE NOTES, LEGENDS & INDEX SHEET DAVIS • MARTIN • POWELLI dmpENGINEERS & SURVEYORS 6415 OLD PLANK RD, HIGH POINT, NC 27265 1 T: (336) 886-4821 1 F: (336) 886-4458 1 WWW.DMP-INC.COM I LICENSE: F-0245 THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT, THEY ARE NOT TO BE USED BY THE OWNER OR ANY OTHER PERSON ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. © COPMW 2006 BY EIM WE ~AID ARd#IECTS PA, ALL NO RESFRYFD. OUR AS PTAMTIED UNDER THE UNITED STATES COPYRIGHT ACT OF 1976, NO PARE OF THIS DOCUMENT MAY BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE WRITTEN PERMISSION OF ERSOY & ASSOCIATES, PA DRAWN : HMC CHECKED: BAP COMM. : 1701 DATE :08-11-2021 200033 CO. I OF