Loading...
HomeMy WebLinkAboutWQ0043049_Application (FTSE)_20211203DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: 'zoo 'apC (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Town of Angier (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State'County ® Municipal ❑ Other 3. Signature authority's name: Jimmy Cook per 15_A NCAC: 021 .0; (wit b Title: Utilities Director 4. Applicant's mailing address: PO Box 278. City: Angier State: NC, Zip: 27501-_ tic 5. Applicant's contact information: Phone number: (919) 331-6702 Email Address: ics ok(ir),angier.org ors 11. PROJECT INFORMATION: o„ 1. Project name: Kennebec Crossing Subdivision Q.fp `9 pt g� ?a 2. Application,Project status: ® Proposed (New Permit) ❑ Existing Permit/Project Ore If a modification, provide the existing permit number: WQ00_ and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Wake County 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.32: Longitude: -78.45 5. Parcel ID (if applicable): 0675302448, 0674390203, 0674391027 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: S. Salman Moazzam Firm: ESP Associates. Inc. Mailing address: 2200 Gateway Centre Boulevard, Suite 216 City: Morrisville State: HQ Zip: 27560- Phone number: (919) 415-2718 Email Address: smoazzam@espassociates.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: NHRWWTP Permit Number: NC0021636 Owner Name: Harnett County License Number: 028116 V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQS00183 Downstream (Receiving) Sewer Size: 15" inch tem Wide CQllectinn_SystattuDi umberls)Lif wplicable): WQCS00I83 Owner Name(s): Town of Angier FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N A 2. If the Applicant is a Developer of lots to be sold, has a Deve er s 0 era orial greemept (FORM: DEV) been attached? ❑ Yes ❑No ZN; A 3. If the Applicant is a })pimiPropeiy Owriely Association, Wag' O teraEionul Agreement (FORM; HQA) been attached? ❑ Yes ❑No ®N!A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Residential Leased ❑ School / preschool :' day care ❑ Food and drink facilities ❑ Businesses / offices , factories 0 Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental veterinary facilities ❑ Church 0 Nursing Home 0 Car Wash O Hotel and/or Motels ❑ Swimming Pool !Clubhouse ❑ Swimming Pool/Filter Backwash O Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial :°%o Commercial % Industrial (See 15A NCAC Q2't .0) 03(2o)) �ls there a Pretreatment Program in effect? D Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC AC. 027 .01 1 4{I)? ® Yes ❑ No If ves. provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see O'I".0i I41fn) Daily Design Flow'.b No. of Units Flow Single Family Residential 360 gal/day 83 29,880 GPD gal/ GPD gal/ GPD gal/ GPD gall GPD gal/ GPD Total 29,880 GPD a See 15A NCAC 02T Q.I I4{b}. (d1.101 I) and ( () for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in (i.. 42A-.1). b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table ISA NCAC 02T,Q114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 29 880 GPD (per I SA NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDCGravlty Sewer*; I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 3,021 SDR 35 PVC 8 81 DIP • Section Il & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Muins7; COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with I5A NCAC 02T .031 hj): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): • Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow Tess than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 • IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(1)): 1. Does the project comply with all separations found in 13A NCAC 0;.. _03051f) ) ➢ 15A NCAC 02T.0305(f} contains minimum separations that shall be rovided f r El Yes ❑ No p o sewer Setback Parameter* systems. Separation Required 24 inches Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW. or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ .# !CAC 02T.0305W) contains alternatives where separations in 02T,0305 1l cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications w_ttsagg ➢ If noncompliance with 02T_O305(f) rar i g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N. A ➢ See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the altemative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 1 5A NCAC 12B .0200! This would include Trout Buffered Streams per 15A NCAC'-B.0202 4. Does the project require coveragerauthorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 49.1k BufferPerroitting Branch ® Yes ❑ No ❑ N.A ®Yes El No 5. Does project comply with 1 A lr* AC 02T.0IO5(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAQ 02T.Q I G5(c)(6l, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per ,SSA NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes ®No ❑NA ➢ if yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02 f, the Mi iwum Des(grt criteria fir the Permitting of lump Stations and Fps Mains jlatest version, and the r vity Sewer Minimum Dean Criteria O tell version) as applicable? ®Yes No If No, complete and submit the Variance:'Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. Professional Engineer's Certification: 1, (Professional Engineer's name from Application Item has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and I43-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per I5A NCAC 02T .0106(b): (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. l also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. ... attest that this application for 1, I`1'l°111`f 1 (o U'\ ).A'' ).(PL UIattest that this application for NOTE - In accordance with General Statutes 143- I54A and i43-2].. 1 3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Date: - ? / FORM: FTA 04-16 Page 5 of 5 tr State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Angier _ Project Name for which flow is being requested: Kennebec Crossing More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NC0021636 c. WWTP facility's permitted flow Fuquay-Varina Allocated Flow Lillington Allocated Flow Angier Allocated Flow d. Estimated obligated flow not yet tributary to the WWTP FV Obligated Flow NYT Lillington Obligated Flow NYT HC Obligated Flow NYT Angier Obligated Flow NYT e. WWTP facility's actual avg. flow FV Actual Flow Lillington Actual Flow HC Actual Flow Angier Actual Flow f. Total flow for this specific request g. Total actual and obligated flows to the facility FV Actual Avg. + Obligated Flow Lillington Actual Avg. + Obligated Flow HC Actual Avg. + Obligated Flow Angier Actual + Obligated Flow All flows are in MGD 7.5 MGD 2.60 MGD 1.20 MGD 1.008 MGD 2.000 MGD 0.653 MGD 0.182 MGD 0.565 MGD 0.600 MGD 5.234 MGD 1.344 MGD 0.676 MGD 2.568 MGD 0.646 MGD .030 MGD* 7.264MGD 2.070 MGD 0.858 MGD 3.130 MGD 1.245 MGD h. Percent of permitted flow used 96.85% *HRW is currently under design for a WWTP Plant upgrade. Il. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. Page 1 of 4 FTSE 06-13 the WWTP: List pump stations located between the project connection point and Pump Station (Name or Number) CONTACT Firm Capacity, * MGD (A) Design Average Daily Flow** (Firm 1 pf), MGD Approx. Current Avg. Daily FIow, MGD (B) (C) Obligated, Not Yet Tributary Daily Flow, MGD TOFV FOR UPSTREAM SLS (D)=(B+C) (E)=(A-D) Total Current Flow Plus Obligated Flow Available Capacity*** CAPACITY INFO SLS 120 14.4 5.76 3.558 1.885 5.473 .257 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): North Harnett Regional WWTP Downstream Permit Number: NC0021636 III. Certification Statement: I Glenn McFadden certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indi}ates acceptance of this wastewater flow. (LW( / t-r Pg. r Signing jicial Signature Date Page 2 of 4 FTSE 06-13 DWR I)I%Rion of latter Resoair State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Town of Angier Project Name for which flow is being requested: Kennebec Crossing Subdivision More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett WWTP b. WWTP Facility Permit #: NC0021636 All flows are in MGD c. WWTP facility's permitted flow 1.008 d. Estimated obligated flow not yet tributary to the WWTP .6003 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used .6248 .0298 I.254 1.24.4°•a II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. PS 3 Firm Capacity, * MGD .270 (A) Design Average Daily Flow" (Firm:' pfl, MGD .108 (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Tributary Flow Plus Avg. Daily Daily Flow, Obligated Flow, MGD MGD Flow Available Capacity*** .056 .0032 .05632 .213 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Town of Angier , NHRWWTP Downstream Permit Number: WQS00183, NC0021636 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Ni •l (Oa- certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. p( Sigrpfg Official Signature QuWL W04K9 Title of Signing Official t ' v(ec-vi- Page 2 of 6 11-19-)-( Date FTSE 10-18 $ESP Department of Environmental Quality Division of Water Resources Water Quality Section 1628 Mail Service Center Raleigh, NC 27699-1628 November 24, 2021 NC Dept of Environmental Quality DEC - 2021 Ralc{gb Regional Office RE: Kennebec Crossing ESP Project: HX39.401 Fast Track Sewer System Extension Application — Cover Letter This application is for a proposed sanitary sewer extension for a Kennebec Crossing subdivision located on Kennebec Church Road and comprises of 83 single-family residential lots on 28.2 acres. Each single-family lot is projected to produce a wastewater volume of 360 GPD, resulting in a total wastewater volume of approximately 29,880 GPD. An 8" gravity line will service the subdivision and will connect to an existing manhole to the north of the site. The proposed sewer will consist of the following: • 8" SDR35 PVC gravity sewer 3,021 LF • 8" DIP 81 LF • Sewer Manholes 20 • Gravity Lateral Connections 83 In addition to this letter, the following items are included in the application package: 1. 2 copies of the Water and Sewer Construction Drawings 2. $480 application fee 3. Fast Track Application (FTA 04-16) 4. USGS Topographic Map 5. Project Vicinity Map Please contact me if you have any questions or comments. Sincerely, ESP Associates, Inc. Salman Moazzam, P.E. DirectI919.415.2718 smoazzarn esDassociates.com 2200 Galer+tia} Ce lln EON d., Sulu? 211 Plurris+ille, \'C 60 1'IurI)C: !l l .678.1070 lay rir'1.h7 7.1?S xrnw.rspassearial+.S.( Iut NC Dept of Environmental Qualit) DEC ~ 3 2021 Raleigh Regional Office +ESP 2200 Gateway Centre Blvd., Suite 216 Morrisville, North Carolina 27560 (919) 678-1070 - Phone (919) 677-1252 - Fax www.espassociates.com TO: Department of Environmental Quality (NC DEQ) Division of Water Resources 1628 Mail Service Center Raleigh, NC 27699-1628 COPY TO: (A) Addressee (B) ESP Main Protect File (C) PM's Protect File LETTER OF TRANSMITTAL ESP Project Name: Kennebec Crossing ESP Project No. HX39.401 Attention: NCDEQ - DWR Date: November 24, 2021 We are Sending: ElEnclosed []Change Order Samples DComputalions []Literature []Specifications []Copy of Letter []Compact Disk Originals Sepia(s) Print(s) 2 Set(s) of Plans ❑ Under separate cover Copies Dated Sheet 1 2 Description FTA Cover Letter;.,. FTA Application (One original & one climnp,mtC FBXir0111: FTSE - Flow Tracking form =. 1 1 1 2 USGS Map Vicinity map nic - 3 Check - $480 fee Construction Plans These are Being Sent: For Your Approval For Your Use For Your Review and Comment For Your Signature For Bids Due LlIalciE. C$ton l oftcu Approved as Noted n Corrected and Returned Approved as Submitted ❑ As Requested Approved as Changed Returned for Corrections Returned After Loan to Us By: n Courier Qx UPS n Mail []Other REMARKS: Please see the Fast Track Application for sewer extension with the required submittal documents with this transmittal. Let me know if there are any questions Thanks. Signed & Date 'If enclosures are not as noted, kindly notify us immediately Salman Moazzam, PE smoazzam esi associatcs uur.1 Direct: 919.576.5454 11/24/2021