Loading...
HomeMy WebLinkAboutSW5220101_Plansheet (L5.00) - Landscape/Planting Plan_20220124EX. EDGE O f PAVEME / z_ '1 ryry :.. \ CLASS III BUFFER ALONG REAR PROPERTY BOUNDARY IF STAKING IS NECESSARY, USE TWO OPPOSING STAKES WITH SEPARATE FLEXIBLE TIES. REMOVE STAKING AT END OF FIRST T TRUNK FLARE AND TOP OF GROWING SEASON ROOT BALL SHOULD BE 2" ABOVE FINISHED GRADE 4" (10 CM) RAISED RING 20' SIDE BUILDING AFTER SETTLING OF SOIL TO DIRECT WATER SETBACK INTO ROOT BALL - ESPECIALLY IMPORTANT IF TOP OF ROOT BALL IS WIDTH OF PLANTING HOLE RAISED ABOVE GRADE SHALL BE 3 TIMES THE ROOT BALL DIAMETER IN 3" (8 CM) BARK MULCH; HIGHLY COMPACTED OR DO NOT PLACE MULCH CLAY SOIL; 2 TIMES THE WITHIN 3" OF TREE TRUNK ROOT BALL DIAMETER MINIMUM IN ALL OTHERS EXTEND STAKES INTO UNDISTURBED SOIL DIG WIDE PLANTING HOLE J %� WITH TAPERED SIDES • '� 4"-6" (10-15 CM) DEEPER PRUNE PROPORTIONALLY TOP OF ROOT BALL SHALL �� ��\��\\��\\�\\ �`� THAN ROOT BALL FOR DUMPSTER ENCLOSURE TO COMPENSATE FOR BE 1" HIGHER THAN CUT BURLAP, ROPE AND LOWERED PLANTING HOLE (SEE ARCHITECTURAL REDUCTION OF ROOTS AND ADJACENT FINISHED GRADE WIRE BASKET AWAY FROM AS NEEDED WITH POOR PLANS) TO PROMOTE NATURAL TOP AND SIDES OF ROOT DRAINAGE CHARACTER OF GROWTH IF BALL AND REMOVE DURING REQUIRED CUT & REMOVE BURLAP BACKFILL PROCESS TO STABILIZE, COMPACT A 3" (8 CM) BARK MULCH; FROM 1/3 OF ROOT PLANTING SOIL MIX DO NOT PLACE MULCH BALL/REMOVE GROW POTS SET ROOT BALL ON BACKFILL AROUND ROOT WITHIN 3" OF COMPLETELY UNDISTURBED SOIL TO BALL; COMPACT SOIL BY TRUNK /STEM 6" MIN. PREVENT SETTLING SOAKING WITH WATER AND O FORM 2" DEEP SAUCER OR LIGHTLY HAND TAMPING + PLANTING SOIL MIX �V��\j PLANTING SOIL MIX TO BE j��j� TAMPED TO AVOID NOTES: 1. SELECT TREES THAT HAVE: STRONG CENTRAL LEADER; CROWN WITH FULL FOLIAGE; ARE GROWN IN HEAVY CLAY SOIL WITH DRIP IRRIGATION. + BACKFILL TO BE �> o ���j; SETTLING 2. BEFORE INSTALLING PLANTING SOIL MIX BACKFILL AROUND ROOT BALL, BE SURE TO + COMPACTED BY SOAKING SUBSOIL BROKEN WITH SOAK HOLE TO CONFIRM WATER FILTERS THROUGH UNDISTURBED SOIL. DESIGN �+ WITH WATER AND OR 3 �'!/%��%��%������%��/%�j,'/!� j//��� PICK ALTERNATIVE DRAINAGE SYSTEM IF REQUIRED. 3. SOIL EXPERT CAN BE CONSULTED TO FERTILIZE TOPSOIL TO + LIGHTLY HAND TAMPED A HELP MODIFY AND + WIDTH OF PLANTING HOLE CREATE AN ACCEPTABLE PLANTING SOIL MIX FOR THE SITE CONDITIONS AND SPECIFIC TWICE ROOT BALL __� SHALL BE 3 TIMES THE TREE SPECIES. WIDTH MIN. ROOT BALL DIAMETER IN 4. IF USING CONTAINER GROWN TREES, USE FINGERS OR SMALL HAND TOOLS TO PULL HIGHLY COMPACTED OR ROOTS OUT OF THE OUTER LAYER OF POTTING SOIL; THEN CUT OR PULL APART ANY CLAY SOIL; 2 TIMES THE ROOTS CIRCLING THE PERIMETER OF THE CONTAINER. ROOT BALL DIAMETER 5. THOROUGHLY SOAK THE TREE ROOT BALL AND ADJACENT PREPARED SOIL SEVERAL MINIMUM IN ALL OTHERS TIMES DURING THE FIRST MONTH AFTER PLANTING AND DURING DRY PERIODS. SHRUB INSTALLATION DETAIL TREE INSTALLATION DETAIL N.T.S. N.T.S. PLANT SCHEDULE CANOPY TREES EVERGREEN SHRUBS CODE QTY O MCWM 48 GROUND COVERS CODE QTY COMMON NAME BOTANICAL NAME Quercus lyrata COMMON NAME BOTANICAL NAME HEIGHT REMARKS Wax Myrtle Myrica cerifera 18" COMMON NAME BOTANICAL NAME CONT REMARKS FE2 1,561 sf Elite Plus Fescue Seed Festuca x 'Elite Plus' Seed LANDSCAPE NOTES 1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF BUNN AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2. CONTRACTOR IS RESPONSIBLE FOR THE SITE INSPECTION BEFORE LANDSCAPE CONSTRUCTION AND INSTALLATION IN ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 3. LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE BEGINNING DEMOLITION OR INSTALLATION. 4. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE NOTES, SPECIFICATIONS, DRAWINGS OR SITE CONDITIONS FOR RESOLUTION PRIOR TO INSTALLATION. 5. ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 6. THIS PLAN IS FOR PLANTING PURPOSES ONLY. FOR INFORMATION REGARDING BUILDINGS, GRADING, WALLS, ETC., REFER TO ARCHITECTURE, SITE AND GRADING PLANS. 7. VERIFICATION OF TOTAL PLANT QUANTITIES AS SHOWN IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. 8. CONTRACTOR TO ENSURE PROPER STABILIZATION AND SEEDING OF THE SITE IN ACCORDANCE WITH APPLICABLE REGULATIONS. 9. LANDSCAPE MATERIAL SHALL BE WELL FORMED, VIGOROUS, GROWING SPECIMENS WITH GROWTH TYPICAL OF VARIETIES SPECIFIED AND SHALL BE FREE FROM DAMAGE, INSECTS AND DISEASES. MATERIAL SHALL EQUAL OR SURPASS #1 QUALITY AS DEFINED IN THE CURRENT ISSUE OF "AMERICAN STANDARD FOR NURSERY STOCK" AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 10. ALL PLANT MATERIAL IS TO BE CAREFULLY HANDLED BY THE ROOT BALL, NOT THE TRUNK, BRANCHES AND/OR FOLIAGE OF THE PLANT. MISHANDLED PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT. 11. ALL PLANT MATERIAL IS TO BE WELL ROOTED, NOT ROOT BOUND, SUCH THAT THE ROOT BALL REMAINS INTACT THROUGHOUT THE PLANTING PROCESS. DEFICIENT PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT OR OWNER. 12. ALL PLANTS TO BE A MINIMUM OF WHAT IS SPECIFIED IN THE PLANT SCHEDULE. ANY CHANGES OR SUBSTITUTIONS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING JURISDICTION PRIOR TO ANY HOLE BEING DUG. 13. CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT TO ESTABLISH THE EXTENTS OF MULCH/SEED/SOD IF NOT SPECIFICALLY SHOWN ON PLANS. 14. CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL PLANTING AREAS. 15. PROPOSED TREES TO BE PLANTED A MINIMUM 10 FEET FROM ANY LIGHT POLE AS MEASURED FROM TRUNK OF THE TREE TO THE POLE. 16. PROPOSED TREES TO BE PLANTED A MINIMUM 5 FEET FROM ANY FIRE HYDRANT AS MEASURED FROM TRUNK OF THE TREE TO THE HYDRANT. 17. CONTRACTOR SHALL COMPLETE SOIL TEST IN ALL PLANTING AREAS TO DETERMINE SOIL AMENDMENT REQUIREMENTS UNLESS WAIVED BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL ADJUST PH AND FERTILITY BASED UPON THE SOIL TEST RESULTS. 18. TOPSOIL SHALL BE FREE OF MATERIAL LARGER THAN 1.0 INCH IN DIAMETER OR LENGTH AND SHALL NOT CONTAIN SLAG, CINDERS, STONES, LUMPS OF SOIL, STICKS, ROOTS, TRASH, OR OTHER EXTRANEOUS MATERIAL. 19. LOOSEN SUBGRADE / SURFACE SOILTO A MINIMUM DEPTH OF 6 INCHES. APPLY SOILAMENDMENTS AND FERTILIZERS AS REQUIRED BY THE SOIL TEST RESULTS TO ACHIEVE A HEALTHY GROWING MEDIA AND MIX THOROUGHLY INTO TOP 4 INCHES OF SOIL. SPREAD PLANTING SOIL MIX TO A DEPTH OF 6 INCHES BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER NATURAL SETTLEMENT. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. 20. IF IMPORTED TOPSOIL IS REQUIRED, THE SUBGRADE SHALL BE SCARIFIED OR TILLED TO A DEPTH OF AT LEAST 6 INCHES PRIOR TO INSTALLATION OF IMPORTED TOPSOIL. FOLLOWING INSTALLATION OF IMPORTED TOPSOIL, THE TOPSOIL SHALL BE TILLED TO INTEGRATE THE SOIL PROFILES. 21. PLANT MATERIALS ARE TO BE GUARANTEED FOR A PERIOD OF 12 MONTHS. PLANT MATERIALS WHICH REMAIN UNHEALTHY WILL BE REPLACED BY THE LANDSCAPE CONTRACTOR BEFORE THE EXPIRATION OF THE GUARANTEE PERIOD OR IMMEDIATELY IF SO DIRECTED BY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 22. ALL TREE PLANTINGS SHALL BE MULCHED TO A DEPTH OF 3 INCHES, AND WITH A MINIMUM 3 FOOT RADIUS FROM BASE OF TREE OR TO DRIPLINE. MULCH SHALL BE FREE OF TRASH AND MAINTAINED WEED FREE. MULCH SHALL NOT COVER THE ROOT FLARE. CONFIRM MULCH SPECIFICATIONS WITH OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 23. DO NOT PRUNE TREES AND SHRUBS BEFORE DELIVERY. PROTECT BARK, BRANCHES, AND ROOT SYSTEMS FROM SUN SCALD, DRYING, SWEATING, WHIPPING, AND OTHER HANDLING AND TYING DAMAGE. DO NOT BEND OR BIND -TIE TREES OR SHRUBS IN SUCH A MANNER AS TO DESTROY THEIR NATURAL SHAPE. PROVIDE PROTECTIVE COVERING OF EXTERIOR PLANTS DURING DELIVERY. DO NOT DROP EXTERIOR PLANTS DURING DELIVERY AND HANDLING. 24. DELIVER EXTERIOR PLANTS AFTER PREPARATIONS FOR PLANTING HAVE BEEN COMPLETED AND INSTALL IMMEDIATELY. IMMEDIATELY AFTER UNLOADING, STAND THE TREES UP TO REDUCE THE RISK OF SUN SCALD. PROPERLY STAGED TREES ARE STANDING, UNTIED AND SPACED. UNLESS IMMEDIATELY INSTALLED, SET EXTERIOR PLANTS AND TREES IN SHADE, PROTECT FROM WEATHER AND MECHANICAL DAMAGE, AND KEEP ROOTS MOIST. 25. SEE LANDSCAPE DETAILS FOR TREE STAKING REQUIREMENTS. 26. EXCAVATE EDGES OF ALL PLANTING BEDS TO 2 INCH DEPTH TO FORM A NEAT AND CRISP DEFINITION. 27. CONTRACTOR SHALL REMOVE DEBRIS AND FINE GRADE ALL PLANTING AREAS PRIOR TO INSTALLATION. 28. REMOVE GUY WIRES AND STAKES AT END OF WARRANTY PERIOD OR ESTABLISHMENT. 29. FINISH GRADING: GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN PLUS OR MINUS 1/2 INCH OF FINISH ELEVATION. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. LIMIT FINISHED GRADING TO AREAS THAT CAN BE PLANTED IN THE IMMEDIATE FUTURE. 30. CONTRACTOR SHALL COORDINATE IRRIGATION DESIGN AND CONSTRUCTION (DESIGN -BUILD). N FIE 18,633 sf Elite Plus Fescue Sod Festuca x 'Elite Plus' Sod wv GRAPHIC SCALE 0 10 20 40 SMDR 632 sf 1"-3" Light Brown Smooth Round/Oval Stone Mulch Stone Provide stone sample to owner prior to ordering 1 inch = 20 ft. PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J L...A D A MS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CLIENT BODDIE-NOELL ENTERPRISES, INC. P.O. BOX 1908 ROCKY MOUNT, NC 27802 Contact PHONE: 252. 937. 2800 W W = liiiiiimm j Q W W (A Z F _2Z am_ az Z ' Z CA aom J M W LLI W �_ o?S 0 O N a a�u na =�N 1995 ' Caleb 16-bins6n Tan 202_ 5 7 AM REVISIONS NO. DATE 1 12. 17. 2021 OWNER COMMENTS 2 1. 20. 2022 NCDEQ RESUBMISSION #1 3 4 5 6 PLAN INFORMATION PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE SHEET 2021110321 2021110321-LS1 CJ R CJ R 1" = 20' 12. 20. 2022 LANDSCAPE PLAN L5e00