HomeMy WebLinkAboutSW5220101_Plansheet - Grading/Drainage Plan_20220124meme
.
eg
. .........
e
6.
GRADING LEGEND
FLARED END SECTION
f0
U
ENDWALL SECTION
CATCH BASIN
+ 250.60
SPOT ELEVATION
STORM DRAINAGE
STORM SERVICE LINE
LD LD
LIMITS OF DISTURBANCE
250
MAJOR CONTOUR
252
MINOR CONTOUR
250 ____
EXISTING MAJOR CONTOUR
_______ 252 ______
EXISTING MINOR CONTOUR
EASEMENT LINE
ACCESSIBLE PARKING AREA
(2% MAX. SLOPE IN ALL DIRECTIONS)
GRADING NOTES
1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE
FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY
DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH
CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO
EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR
ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN
INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT
BEEN GIVEN.
2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)
STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926,
SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5)
FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN
DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A
REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY
CONTRACTOR RESPONSIBLE FOR EXCAVATION.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH FRANKLIN,
AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS
APPLICABLE.
4. CONTRACTOR SHALL NOTIFY "NCDOT" (811) OR (800-632-4949)
AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING
CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES
LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES
THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF
"NCDOT". REPORT ANY DISCREPANCIES TO THE ENGINEER
IMMEDIATELY.
5. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL
CONTRACTOR SHALL SCHEDULE AND ATTEND A
PRE -CONSTRUCTION CONFERENCE WITH FRANKLIN COUNTY
STORMWATER AND EROSION CONTROL DEPARTMENT, THE
ENGINEER AND A REPRESENTATIVE OF THE OWNER.
6. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION
CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED
WITH THE EROSION CONTROL INSPECTOR.
7. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH
UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD
SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE
CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO
BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL
BE REPORTED TO THE ENGINEER IMMEDIATELY.
8. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES
GREATER THAN 3:1 (H:V) SHALL BE APPROVED, PLACED AND
COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL
ENGINEER.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING
AND MAINTAINING ALL CONTROL POINTS AND BENCH MARKS
NECESSARY.
10. 5'X5' PAD AT DOORS WITH MAXIMUM 2% SLOPE IN ALL
DIRECTIONS.
11. SIDEWALK TO BE MAXIMUM 5% SLOPE AND 2% CROSS SLOPE AND
5'X5' PAD 2% IN ALL DIRECTIONS AND CHANGES OF DIRECTION.
12. PATIO AREA TO BE 2% MAXIMUM SLOPE IN ALL DIRECTIONS.
13. ADA AISLE TO BE MAXIMUM 5% LONGITUDINAL SLOPE AND 2%
CROSS SLOPE.
GENERAL NOTES:
1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR
SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO
PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE
CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE
CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES
SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT
BEEN GIVEN.
N
GRAPHIC SCALE
0 10 20 40
1 inch = 20 ft.
PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION
'J
L...A D A
MS
The John R. McAdams Company, Inc.
2905 Meridian Parkway
Durham, NC 27713
phone 919. 361. 5000
fax 919. 361. 2269
license number: C-0293, C-187
www.mcadamsco.com
CLIENT
BODDIE-NOELL ENTERPRISES, INC.
P.O. BOX 1908
ROCKY MOUNT, NC 27802
Contact
PHONE: 252. 937. 2800
W
W
=
liiiiiimm<=
J
LLJ
z
F-
-
7>
Z
am_
az
Z
Z
aom
J
M
W
LLI
W
o?S
0
O
N
a
%%%'111►111j",1,
J.
SEAL'_
N .
Ray Watson
Jan 20 2022 8:45 AM
REVISIONS
NO. DATE
1 12. 17. 2021 OWNER COMMENTS
2 1. 20. 2022 NCDEQ RESUBMISSION #1
3
4
5
6
PLAN INFORMATION
PROJECT NO. 2021110321
FILENAME 2021110321-G1
CHECKED BY XXX
DRAWN BY WHM
SCALE 1" = 20'
DATE 12. 20. 2022
SHEET
GRADING PLAN
C3.00