Loading...
HomeMy WebLinkAboutSW5220101_Plansheet - Proposed Conditions/Site Plan_20220124IIC I ,AIJ IINU M3r-MMLI I Ir.� OR / 1R • 's. DRIVE—THRU CLEARANCE / / 15'R / BAR ��- ��• 20'R F VR EX. EDGE OF / / • PAVEMENT 24" CURB AND GUTTER �:... (TYP.) • / 20'R • • 5' CONCRETE • / SIDEWALK y 4' STREETYARD / / PRE —MENU BOARD • • 20' SIDE BUILDING / \ SETBACK 10' REAR BUILDING SETBACK STORMWATER CONTROL MEASURE \ (SEE "C9" SHEETS) DUMPSTER PAD WITH 6'-8' / HIGH SCREENING (SEE \ ARCHITECTURAL PLANS) / 20' SIDE BUILDING SETBACK \ \ 4' STREETYARD \ 25'R SAWCUT LINE (TYP.) IGHTS \ ,N BY OTHERS) / 5'R \ �p \ / 20'R \ 25'R TIE TO'EXISTING 24" STANDARD CURB AND GUTTER AND o EXISTING ASPHALT (TYP.) 20'R \ SITE LEGEND ACC VAN XX 77 JAL TYPE QA TYPE (D) TYPE QC SIGNAGE YARD LIGHTS LIGHT POLE POWER POLE TRAFFIC DIRECTIONAL ARROW ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL PARKING SPACE COUNT ACCESSIBLE RAMPS ACCESSIBLE ROUTE - - PROPERTY LINE - - - RIGHT-OF-WAY LINE - - - - LOT LINE EASEMENT LINE SITE PLAN NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST LOCAL AND STATE MUNICIPALITY AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 2. ALL DIMENSIONS SHOWN ON SITE PLAN ARE MEASURED TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 4. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION AND TO THE SATISFACTION OF THE OWNER, BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 5. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 6. CONTRACTOR SHALL NOTIFY "NCDOT" (811) OR 800-632-4949 AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NCDOT". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 7. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATIONS (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 8. PRIOR TO BEGINNING CONSTRUCTION BEYOND EROSION CONTROL MEASURES, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE LOCAL AND STATE MUNICIPALITY PUBLIC WORKS DEPARTMENT AND A REPRESENTATIVE OF THE ENGINEER AND OWNER. THE PURPOSE OF THIS MEETING IS TO REVIEW THE SPECIFIC COMPONENTS OF THE PLAN AND OPERATION OF THE FACILITIES DURING CONSTRUCTION. 9. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 10. PEDESTRIAN EXISTING ROUTES AND ALTERNATE PEDESTRIAN ROUTES DURING CONSTRUCTION WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 11. TYPICAL PAVEMENT SECTION DETAILS ARE SHOWN WITHIN THIS PLAN SET AND INTENDED TO BE A MINIMUM PAVEMENT SECTION REQUIREMENT. THE CURRENT GEOTECHNICAL REPORT SHALL OVER -RIDE ALL TYPICAL PAVEMENT SECTIONS SHOWN, IF THE GEOTECHNICAL ENGINEER DEEMS A HEAVIER SECTION IS REQUIRED. 12. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO SUBSTITUTION OF ALTERNATE EQUIPMENT. 13. IF UNFORESEEN CONDITIONS DEVELOP DURING CONSTRUCTION, REFER TO THE LATEST VERSION OF THE LOCAL AND STATE MUNICIPALITY SPECIFICATIONS AND STANDARDS 'J L...A D A MS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CLIENT BODDIE-NOELL ENTERPRISES, INC. P.O. BOX 1908 ROCKY MOUNT, NC 27802 Contact PHONE: 252. 937. 2800 W W J Q W W F_ cc F_ Z F_ Z ama� Z Z Z aom J M W LLI W o?S 0 O N a SEAL „, , WATSON' ►►► ,ay Watson an 20 2022 8:43 AM REVISIONS NO. DATE 1 12. 17. 2021 OWNER COMMENTS 2 1. 20. 2022 NCDEQ RESUBMISSION #1 3 4 5 6 PLAN INFORMATION PROJECT NO. 2021110321 FILENAME 2021110321-S1 CHECKED BY RW DRAWN BY WHM SCALE 1" = 20- DATE 12. 20. 2022 / SHEET i N SITE PLAN / GRAPHIC SCALE 0 10 20 40 oo 1 inch = 20 ft. . PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADatvts The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com ;LIENT ODDIE-NOELL ENTERPRISES, INC. .0. BOX 1908 OCKY MOUNT, NC 27802 ontact HONE: 252. 937. 2800 �=n W W z a W W Q H J W W Q ~ F z 00aZ z�nm Jo aM W H a � O N `,\\A CA SS/ 0• % .Q • SEALlep - 1 WATSC� y Watson 120 2022 8:44 AM tEVISIONS 0. DATE 1 12. 17. 2021 OWNER COMMENTS 2 1. 20. 2022 NCDEQ RESUBMISSION #t1 3 4 5 5 OLAN INFORMATION ROJECT NO. 2021110321 ILENAME 2021110321-S1 NECKED BY RW RAWN BY WHM CALE 1" = 20- ATE 12. 20. 2022 SHEET PAVEMENT MARKING PLAN C 801 i / EX. SSMH r 273.6$'= OL 272 34 = OL , 6W33 = OL r 165.99 = O/ 6.01' _LZ / 4' STREETYARD TOP OF STORM "/ BOTTOM OF STORM TOP OF SANITARY / BOTTOM OF SANITARY / / r UTILITY LEGEND / !�% N WATER VALVE d' EX. SSMH �'o � / METER & VAULT BACKFLOW PREVENTER / ErX. POWER PO .. r ATER • SEWER CLEAN -OUT SEE ATER CONNECTION '" / �- DET,A1L BELOW / GREASE TRAP / EX. FIRE HYDRANT % �.�.�,,,, ,,,,, . ; ���ij ASSEMBLY / \ YARD LIGHTS POWER POLE 2 - 2" CONDUITS \ WATER SERVICE LINE \- - - - - - - - - - - - - - - UTILITY SLEEVE r r / SEWER SERVICE LINE ,r „i Pfi -GGGG GAS LINE \ / ? SITE LIGHT` / \ EX. OVERHEAD OU OU OVERHEAD UTILITY (DES1G °�BY OTHERS) // �4'P \ F+ POWER LINE c 1 UE UE UNDERGROUND ELECTRIC &° 'O� - - EASEMENT LINE \� �� 45' BEND \ V ,S" /� %% ,,� - �i / �� /,� /' ....vv s°TEFaoKT BUILDING" G6, 1. UTILITY NOTES: / EX. OVERHEAD \ �o " POWER LINE�� �o 1. ALL WATER MAINS, SERVICES AND FIRE SERVICES GREATER THAN 2" DIAMETER ARE TO BE DUCTILE IRON PIPE. 2" & SMALLER DOMESTIC SERVICES MUST BE TYPE K SOFT COPPER (WITHOUT FITTINGS) OR HDPE SDR-9 TO THE WATER METER. / 2" PVC DOMESTIC WATER LINE 2. ALL SEWER MAINS SHALL BE EITHER PVC OR DUCTILE IRON PIPE AS SHOWN ON THE PLANS. ALL PIPE MATERIAL SHALL MEET TOWN OR COUNTY STANDARDS AND SPECIFICATIONS AS DEFINED IN THE LATEST ISSUE OF THE PUBLIC CORE AND TAP EXISTING SANITARY SEWER MANHOLE /' / I 3/4" PVC WATER LINE I I \ \ UTILITIES HANDBOOK AND/OR UNIFIED DEVELOPMENT ORDINANCE (UDO). / yak �� EX. POWER POLE (SEE DETAIL ON C8.01) 2" CONDUIT \ ', ? 3. ALL FIRE HYDRANTS ALONG PUBLIC RAW LINES SHALL HAVE A 5'WX5'L TOWN OR COUNTY WATERLINE EASEMENT ONTO ADJACENT PROPERTY. r / 2" IRRIGATION CONDUIT � _ � 2" IRRIGATION CONDUIT / A 4. ALL SANITARY SEWER INTERCEPTOR LINES (12" AND LARGER), AS WELL AS MANHOLES AND FITTINGS ASSOCIATED CROSSING If�RMATION 4►�ROX : / �' O A / WITH THE INTERCEPTOR LINE, SHALL BE INTERNALLY LINED WITH PROTECTO 401 OR APPROVED EQUAL TO PREVENT �6 ( \ f 4' STREETYARD �` HYDROGEN SULFIDE CORROSION. SEETHE CURRENT TOWN OR COUNTY PUBLIC UTILITIES DEPARTMENT HANDBOOK / 272.94 - UTSIDE�7TP1F STORM / /' 271.31 . OUTSIDE�TOM OF STORM / // A ''� FOR APPROVED COATINGS AND APPLICATION METHODS. 266/01 = OUTSIDE,P OF SANITARY ?65S.68 = OUT 1& BOTTOM OF SANITARY / \ y 45' BEND %� `- -�-� �_ � 5. ALL UNDERGROUND UTILITIES INSTALLED SHALL BE ELECTRONICALLY LOCATABLE. CONTRACTOR SHALL COORDINATE / / \ 2" PVC DOMESTIC / \ \ DIRECTLY WITH THE TOWN OR COUNTY PUBLIC UTILITIES DEPARTMENT FOR DETAILS AND SPECIFICATIONS FOR WATER LINE �� �� V ' �i� MEETING THESE REQUIREMENTS. . \ s/ . 2" CONDUIT \ \ 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ' � ,a ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. �\ 2 - 2" DATA CONDUITS FOR �a'� y � 2 - 4" CONDUITS � V j i TELEPHONE AND INTERNET. / 7. ALL WATER AND SEWER MAINS WITHIN PUBLIC EASEMENTS OR RIGHTS -OF -WAY TO BE OWNED, OPERATED, AND / F ��� FREEZE PROOF ��'� \\ '?� MAINTAINED BY TOWN OR COUNTY. CONTRACTOR TO COORDINATE --/� YARD HYDRANT s� LOCATION WITH SERVICE PROVIDER 8. ALL WATER AND SEWER MAINS NOT WITHIN PUBLIC EASEMENTS OR RIGHTS -OF -WAY TO BE PRIVATELY OWNED, f / 2" IRRIGATION CONDUIT .. BUILDING \V OPERATED, AND MAINTAINED BY THE PROPERTY OWNER. T�% \ 9. CONTRACTOR SHALL NOTIFY "NC811" (811) OR 1-800-632-4949 AT LEAST 3 FULL BUSINESS DAYS PRIOR TO 2" CONDUIT 45' BENDS FFE: 280.25' �' // BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT 2" WATER SERVICEANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY 4" SDR 35 PVC „/�>(SEE ARCHITECTURAL PLANS DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SANITARY SEWER SERVICE�(2) FOR ACTUAL TIE-IN LOCATION) // (2.08% MIN SLOPE) �r // 10. ALL UTILITY SLEEVES SHALL BE SCHEDULE 40 PVC AND INSTALLED WITH 2' MINIMUM COVER. BOTH ENDS SHALL BE 2" IRRIGATION CONDUIT / \ CAPPED AND MARKED. APPROX. LOCATION OF /6 SANITARY LINE. s (SEE ARCHITECTURAL 11. YARD HYDRANTS TO BE FROM IRRIGATION METER. PLANS FOR DETAILS) 7/\ 00 12. WATER SERVICE SHALL BE INSTALLED BY CONTRACTOR. / / 13. CONTRACTOR SHALL COORDINATE IRRIGATION DESIGN AND CONSTRUCTION (DESIGN -BUILD). / 20' SIDE BUILDING ° SITE LIGHT (DESIGN BY OTHERS) 10' REAR BUILDING \ 'SETBACK \� STORMWATER CONTROL \ MEASURE \\ (SEE "C9" SHEETS) DETECTION LOOP 3/4" PVC WATER LINE 20' SIDE BUILDING SETBACK / \-8'X8' TRANSFORMER PAD CONTRACTOR TO COORDINATE DESIGN, SPECIFICATIONS AND FINAL LOCATION WITH UTILITY PROVIDER. FREEZE PROOF YARD HYDRANT EX. 12" W/L (LOCATION AND SIZE TO BE FIELD VERIFIED) WATER SERVICE TO BE INSTALLED BY PRIVATE CONTRACTOR INSTALL ROMAC OR APPROVED - EQUIVALENT 2" TAPPING SLEEVE CONTRACTOR TO FIELD VERIFY EXISTING WATER LINE SIZE AND NOTIFY ENGINEER OF ANY DISCREPANCIES. INSTALL ROMAC OR APPROVED EQUIVALENT 2" MJ GV 1" IRRIGATION METER TO IRRIGATION SYSTEM (DESIGN BY IRRIGATION CONTRACTOR) I ' I I 1 2" SCH-40 PVC � I I - 2" DOMESTIC WATER - SERVICE WITH 1.5" METER 2 - WATTS MODEL 909 OR APPROVED EQUIVALENT RPZ IN ABOVE GROUND HEATED ENCLOSURE WITH 4" CONCRETE PAD \AI ATrP1 A-^N I H 1 r!"T1^AI 1%r-rA 11 \\ IRR ---_ �Rk \ " \ 1 " SCH-40 PVC W/L TO IRRIGATION (IRRIGATION BY IRRIGATION CONTRACTOR) 3/4" SCH-40 PVC W/L TO (3) FREEZE PROOF YARD HYDRANTS BY G/C/SITE CONTRACTOR 2" SCH-40 PVC DOMESTIC WATER LINE TO BUILDING N GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J h�..uA D MS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CLIENT BODDIE-NOELL ENTERPRISES, INC. P.O. BOX 1908 ROCKY MOUNT, NC 27802 Contact PHONE: 252. 937. 2800 W W J Q W W z ama� Z Z °° � a J O W � LLI LLI H 0 O � N a CAR SEAL WATSo N' Ray Watson Jan 20 2022 8:46 AM REVISIONS NO. DATE 1 12. 17. 2021 OWNER COMMENTS 2 1. 20. 2022 NCDEQ RESUBMISSION #1 3 4 5 6 PLAN INFORMATION PROJECT NO. 2021110321 FILENAME 2021110321-U1 CHECKED BY RW DRAWN BY WHM SCALE 1" = 20' DATE 12. 20. 2022 SHEET UTILITY PLAN C4.00