Loading...
HomeMy WebLinkAboutWQCSD0523_Compliance Evaluation Inspection_20120607Permit: WQCSD0523 SOC: County: Onslow Region: Wilmington Compliance Inspection Report Effective: 03/01/00 Expiration: Owner: Rexon LTD Effective: Expiration: Facility: Collins Estates MHP Collection System Contact Person: Ellen Ford Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Ellen Ford Wade Cogdill Title: Park Manager Certification: NC0036676 Rexon LTD - Collins Estates Mobile Home Park WWTP Inspection Date: 06/07/2012 Entry Time: 01:30 PM Exit Time: 02:15 PM Primary Inspector: Lamont Allen Secondary Inspector(s): Phone: 910-353-2086 Phone: Phone: 910-353-2086 Phone: 910-545-8934 Phone: 910-796-7333 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: 0 Compliant ■ Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records ■ Monitoring & Rpting ■ Inspections Pump Station Manhole Reqmts ■ Lines (See attachment summary) Page: 1 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: For privately owned collection systems, the Grease Control Program shall include at least biannual distribution of grease education materials to users of the collection system by the permittee or its representative. A pump station log was available but it had insufficient information. A Pump Station inspection log or summary should included , at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee or its representative. The log should also document at least one weekly comprehensive inspection that includes the testing of floats and audio/visual high water alarms.The pump station needs external A/V alarms installed; This was also noted in the NOV letter sent June 8, 2010. Collins Estates MHP has a deemed collection system and should follow the requirements under 15A NCAC 02T .0403. Page: 2 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Is Public Education Program for grease established and documented? What educational tools are used? For privately owned collection systems, the Grease Control Program shall include at least biannual distribution of grease education materials to users of the collection system by the permittee or its representative. Is Sewer Use Ordinance/Legal Authority available? Does it appear that the Sewer Use Ordinance is enforced? Is Grease Trap Ordinance available? Is Septic Tank Ordinance available (as applicable, i.e. annexation) List enforcement actions by permittee, if any, in the last 12 months Has an acceptable Capital Improvement Plan (CIP) been implemented? Does CIP address short term needs and long term \"master plan\" concepts? Does CIP cover three to five year period? Does CIP include Goal Statement? Does CIP include description of project area? Does CIP include description of existing facilities? Does CIP include known deficiencies? Does CIP include forecasted future needs? Is CIP designated only for wastewater collection and treatment? Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments Is system free of known points of bypass? If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? # Does the sign include: Instructions for notification? Pump station identifier? 24-hour contact numbers Yes No NA NE 110011 nn■n n n ■ n nn■n nn■n nn■n nn■n nn■n nn■n nn■n ■nnn ■nnn ■nnn ■nnn ■nnn Page: 3 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling If no, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? Number of pump stations Number of pump stations that have SCADA Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? # If yes, date implemented? Describe: Reason for Visit: Routine ■nnn 1 0 0 0 0 nn■n Comment: Pump stations without Supervisory Control and Data Acquisition (SCADA) systems or telemetry shall be inspected everyday (i.e. 365 days per year). Pump stations equipped with SCADA systems or telemetry shall be inspected at least once per week. Inspections Are maintenance records for sewer lines available? Are records available that document pump station inspections? Are SCADA or telemetry equipped pump stations inspected at least once a week? Are non-SCADA/telemetry equipped pump stations inspected every day? Are records available that document citizen complaints? # Do you have a system to conduct an annual observation of entire system? # Has there been an observation of remote areas in the last year? Are records available that document inspections of high -priority lines? Has there been visual inspections of high -priority lines in last six months? Comment: Pump stations without Supervisory Control and Data Acquisition (SCADA) systems or telemetry shall be inspected everyday (i.e. 365 days per year). Pump stations equipped with SCADA systems or telemetry shall be inspected at least once per week. Operation & Maintenance Requirements Are all log books available? Does supervisor review all log books on a regular basis? Yes No NA NE nnn■ ■nnn nn■n ■nnn nnn■ nnn■ nn■n nn■n nn■n Yes No NA NE nnn■ nnn■ Page: 4 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Does the supervisor have plans to address documented short-term problem areas? ❑ ❑ 0 ■ What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Are maintenance records for equipment available? ❑ ❑ ❑ ■ Is a schedule maintained for testing emergency/standby equipment? ❑ ❑ ❑ ■ What is the schedule for testing emergency/standby equipment? Do pump station logs include Inside and outside cleaning and debris removal? n ■ n n Inspecting and exercising all valves? n ■ n n Inspecting and lubricating pumps and other equipment? n ■ n n Inspecting alarms, telemetry and auxiliary equipment? n ■ n n Is there at least one spare pump for each pump station w/o pump reliability? n n ■ n Are maintenance records for right-of-ways available? n n ■ n Are right-of-ways currently accessible in the event of an emergency? n n ■ n Are system cleaning records available? nn■n Has at least 10% of system been cleaned annually? n n ■ n What areas are scheduled for cleaning in the next 12 months? Is a Spill Response Action Plan available? ❑ ❑ ❑ ■ Does the plan include 24-hour contact numbers n n n ■ Response time n n n ■ Equipment list and spare parts inventory n n n ■ Access to cleaning equipment n n n ■ Access to construction crews, contractors, and/or engineers n n n ■ Source of emergency funds n n n ■ Site sanitation and cleanup materials n n n ■ Post-overflow/spill assessment n n n ■ Is a Spill Response Action Plan available for all personnel? n n n ■ Is the spare parts inventory adequate? n n n ■ Comment: should have a plan so everyone knows what to do. Page: 5 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? nnn ■ Are records of SSOs that are under the reportable threshold available? nnn ■ Do spill records indicate repeated overflows (2 or more in 12 months) at same location? nnn ■ If yes, is there a corrective action plan? nnn ■ Is a map of the system available? ■ n n n Does the map include: Pipe sizes 00011 Pipe materials n ■ n n Pipe location ■ n n n Flow direction ■ n n n Approximate pipe age n ■ n n Number of service taps n ■ n n Pump stations and capacity n ■ n n If no, what percent is complete? List any modifications and extensions that need to be added to the map # Does the permittee have a copy of their permit? n n n n Comment: The map that was sent in is adequate ( add FM & GS line size). Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? n n ■ n Are public notices and proof of publication available? n n ■ n # Is an annual report being prepared in accordance with G.S. 143-215.1 C? n n ■ n # Is permittee compliant with all compliance schedules in the permits? n n ■ n If no, which one(s)? Comment: Deemed permitted system MAIN PUMP STATION - Collins Estate MHP Pump Station Pump station type Are pump station logs available? Is it accessible in all weather conditions? Yes No NA NE Duplex ■nnn ■nnn Page: 6 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine # Is general housekeeping acceptable? ■ n 00 Are all pumps present? ■ n n n Are all pumps operable? ■ n n n Are wet wells free of excessive debris? ■ n n n Are upstream manholes free of excessive debris/signs of overflow? n n n ■ Are floats/controls for pumps/alarms operable? ■ n n n Is "auto polling" feature/SCADA present? n n ■ n Is "auto polling" feature/SCADA operational? n n ■ n Is simple telemetry present? n ■ n n Is simple telemetry operational? n n ■ n Are audio and visual alarms present? ■ n n n Are audio and visual alarms operable? ■ n n n Is the Pump station inspected as required? ■ n n n Are backflow devices in place? ■ n n n Are backflow devices operable? ■ n n n Are air relief valves in place? n n ■ n Are air relief valves operable? n n ■ n # Is an emergency generator available? n n ■ n Can the emergency generator run the pumps? n n ■ n Is the pump station equipped for quick hook-up? ■ n n n Is the generator operable? n n ■ n # Is fuel in tank and sufficient? n n ■ n Is the generator inspected according to their schedule? n n ■ n Is a 24-hour notification sign posted? ■ n n n Does it include: Instructions for notification? ■ n n n Pump station identifier? ■ n n n Emergency phone number ■ n n n Is public access limited? ■ n n n Is pump station free of overflow piping? ■ n n n Page: 7 Permit: WQCSD0523 Owner - Facility: Rexon LTD Inspection Date: 06/07/2012 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Is the pump station free of signs of overflow? Are run times comparable for multiple pumps? Comment: A pump station log was available but it had insufficient information. A Pump Station inspection log or summary should included , at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee or its representative. The log should also document at least one weekly comprehensive inspection that includes the testing of floats and audio/visual high water alarms. ■nnn Page: 8