Loading...
HomeMy WebLinkAboutWQ0024693_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality December 15, 2004 Mr. Jon Dyer, Public Works Director - Union County 400 North Church Street Monroe, North Carolina 28112 Subject: Permit No. W00024693 Union County West Fork Twelve Mile Creek Phase III Trunk Sewer Wastewater Collection System Extension Union County, North Carolina Dear Mr. Dyer: In accordance with your application received on December 15, 2004, we are forwarding herewith Permit No. WQ0024693, dated December 15, 2004, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June-1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.state,nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper No thCarolina Naturally Dyer ge 2 ecember 15, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County for the construction and operation of approximately 240 linear feet of 15-inch gravity sewer; approximately 1,337 linear feet of 24-inch gravity sewer; approximately 4,520 linear feet of 30-inch gravity sewer; and approximately 2,129 linear feet of 36-inch gravity sewer to serve as an interceptor line as part of the West Fork Twelve Mile Creek Phase 111 Trunk Sewer project, with no additional discharge of collected domestic wastewater (flow will be permitted in subsequent permits that connect to this line) into Union County's existing sewerage system, pursuant to the application received December 15, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County Twelve Mile Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, for Alan W. Klimek,P E. cc: Union County Health Department - , Mooresville Regional Office, Water Quality Section (WV TfF.Permit No. NC0085359 ) Williani Riddick, McKim & Creed Water Quality Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at al! times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. High -priority sewer_Ilnes shall be inspected attleast once per. .eyery._six month period of time.;- f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be •appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result_in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement .action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event. that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. ,Noncompliance Notification ut The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Forrn CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence: This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 15th day of December, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024693 • 3 st Track En • ineerin • Certification Permit No. WQ0024693 December 15, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the West Fork Twelve Mile Creek Phase III Trunk Sewer, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWINGADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 2i3'I'I5 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. z 0 1- 2 0 LL z z 0 LL Z TY SEWERS, PAP STATIONS, AND FORCE: MAINS USE THE TAR KEY i°°s.0 MOVE FROM FIELD TO FIELD! Owner la. Union County Department of Public Works Full Legal Name (company, municipality, HOA, utitaty, etc.) 1b. Jon C. Dyer, PE, Director, Union County Department of Public Works Application Number: (tobe completed by DWQ) VV 00 PAGE 3 Signing Official Name and Title (Please review 15A NCAC 2H .0266(b) for authorized signing officials!) lc. The legal entity who will own this system is Q Individual Q Federal Q Municipality ai State/County Q Private Partnership Q Corporation Q Other (specify): ld. 400 North Church Street et Address NC State lh. 704-296-4210 704-296-4232 Telephone Facsimile 2. Project (Facility) inforrnatiion: 2a. West. Fork Twelve Mile Creek Phase tli Trunk Brief Project Name (permit wilt refer to th 3. Contact Person: 3a, Charlie O'Cain, PE, Deputy Director le. Monroe City lg. 28112-4804 Zip Code jondyerpa.un'ion,nc.us E-mail 2b. Union County County Where Project is Located Name and Affiliation of Someone Who Can Answer tuestions About this Appliication 3b. (704) 296-4214 Phone Number 'cain co.union.nc,us 1. Project is ' +1 New Q Modification of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining tfte reason for the modification (i. phase, changing line size/length, etc.). Only include the modified information in this permit ap duplicate project information in B(7) and B(1O-11) that has already been included in the original 2, Owner is Public (skip to Item 8(3)) Q Private (go to Item 2(a)) 2a. If private, applicant will be: © Retaining Ownership (i.e. store, church, single office, etc.) or Q Leasing units (lots, townhomes, etc. skip to Item 8(3)) Q Selling units (lots, townhomes, etc. - go to Item B(24)) Union County ding anot ion - donut 2b. If sold, facilities owned by a (must choose one) Q Public Utility (Instruction 111) Q Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treat Twelv Name of Union Coun Owner of Downstream Se nt Facility (WWTF) Treating Wastewater From This Projr 4, NU:085359 WWTF Permit No, Receiving Sewer Size The origin of this wastewater is (check all that apply): Residential Subdivision Apartments/Condominiums Mobile Horne Park School Restaurant Office W Q0024089 Permit Number of Downs CS Car Wash Q Institution Q Hospital Church Q, Nursing Home Other (specify): 7. Volume of wastewater to be permitted in this project: a, gallons per day l av% Domestic/Commercial % Industrial % Other (specify): tf the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted is subsequent permits that connect to this line Q Flow has already been allocated in Permit No. Q Rehabilitation or replacement of existing sewer with no new flow expected APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mad Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). Oci I 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Gravity or Force Main Size (inches) Length (feet) (use the pull down menu) 36 2,129 Gravity 30 4,520 Gravity 24 1,337 Gravity 15 240 Gravity z a 0 ENTER TOTAL LINE LENGTH IN MILES 1,56 0 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option CC (self chosen - as shown on Design Flow Operational Point (1- dual fine feed; 2- permanent generator w/ATS; 3- 0 plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) LL z 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force! Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable?! 0 Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLIC.ATIONi 13, Havethe following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes P14 No 0 N/A Sedimentation and Erosion Control Plan? Yes 0 No 0 N/A Stormwater? 0 Yes 0 No N/A FTA 02/03 Rev, 1 06/03 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Z 0 awaterbody; () LL (/i J 0See a LLJ CO U 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS). to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: • A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope AND, • A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map 1 (self chosen - as shown on Name of i j . Waterbody Stream map for cross-reference) 1 Waterbody I County I River Basin , Index I Waterbody Classification West Fork Twelve Mile , I Attached ! Creek. + Union I Catawba 11-138-1 I C _ F -- + --v ----! -- ! ' i 1- - -- - + - ---- t 1 I I Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! LIJ— Z I— Q V LL F, CC W () Q 1. Applicant's Certification: 1, Jon C Dyer, PE, attest that this application for West Fork 12-Mile Ck PH 3 Trunk Sewer has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215.6A and 143 215.6B, any person who knowingly makes any false statement, representation, or certification in any a lication shall be guilty of a Class 2 misdemeanor hich may include a fine not to exceed $10,000 as well as civil . e ;ties up to $25,000 per v' ion. 1 (7 � f 91dA �Si nin Official Si nature Date Signing g 2. Professional Engineer's Ce ification: I attest that this application for West Fork 12-Mile Ck PH 3 Trunk Sewer has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. William S. Riddick, PE .r+"`� ,����'�, " g�+•R®���+ Q�E��/�� ►► 9 .. SEAL % ; t1et Q. {'ram o , e l A q. 4, ►►►i►r�°.,P"G����,.•°.$ / - 4 4+{1��a •A•, , // ''Imil ,, fy_ ,! ► ; is Professional Engineer Name 2b. McKim & Creed Engineering Firm _ _ _ 2c. 8020 Tower Point Drive Address 2d. Charlotte '2e. NC 2f. 28227 City State Zip I I 2g. 704 841 2588 2h. 704-8412567 2i. sriddick@mckimcreed.com /A Telephone I Facsimile ! E-mail ,( FTA 02/03 - Rev. 1 06/03 Name: WAXHAW Date: 10/5/2004 Scale: 1 inch equals 2000 feet 080° 43' 0.00" W paw 42 Location: 034° 58' 29.2" N 080° 43' 30.8° W Caption: WEST FORK 12-MILE CREEK PHASE tll TRUNK SEWER 7, %,laptech, €k 12/15/04 Permit Number WQ0024693 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.basinger Permitted Flow 0 Facility Status Protect Type In review New Project Version Permit Classification individual Permit Contact Affiliation Facility Name West Fork Twelve Mile Creek Phase 11I Trunk Sewer Location Address Owner Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affiliation John Dyer 400 N Church St Monroe NC 28111 Scheduled Orig Issue App Received Draft Initiated Issuance 12/15/04 Regulated Activities Public Notice Issue Effective Apartment complex Car wash facility Commercial or industrial, other Institution, other Restaurant School Subdivision Wastewater collection Outfail NULL 129 51D 4 RequestedlReceived Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasln UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve West Fork Twelve Mile Creek, TR`..NSIV�IJTTAL L looR: r 4..J •f ��lR'� r DEC 1 5 2004 uP-Y i :. Date: 12/ T41041 Phase Ill Trunk Sewer We are sending you: ['Copy of letter ❑ Plans ❑ Prints ❑ Shop Drawings ® Other Copies Date No. Description 1 11/18/04 Original Non Discharge Permit Application 1 11/18/04 Copy of Non Discharge Permit Application 1 11/22/04 20253 Check for $400.00 (Application Fee) These are transmitted as checked below: ® For approval ❑ For your use ❑ As requested Remarks: Signed: doo,oi ❑ For review and comments Received by: Date: