Loading...
HomeMy WebLinkAboutWQ0024444_Regional Office Historical File Pre 2018tL CF WA T69(70 Mr. Jon Dyer, Public Works Director Union County 400 North Church Street Monroe, North Carolina 28112 Dear Mr. Dyer: Michael F. Easley, Governor William G. Ross Jr.. Secretary North Carolina Department of Environment and Natural Resources Alan W. Iaimek, P.E. Director Division of Water Quality October 12, 2004 Subject: Permit.No. WQ0024444 Union County Lawson Subdivision Wastewater Collection System Extension Union County, North Carolina In accordance with your application received on October 4, 2004, we are forwarding herewith Permit No. WQ0024444, dated October 12, 2004, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and [imitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper No ` Carolina ,Naturally Mr. Jon Dyer Page 2 October 12, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is -hereby granted to Union County for the construction and operation of approximately 23,267 linear feet of 8-inch gravity sewer, and approximately 992 linear feet of 12-inch gravity sewer to serve 350 single family residences as part of the Lawson Subdivision project, and the discharge of 126,000 gallons per day of collected domestic wastewater into Union County's existing sewerage system, pursuant to the application received October 4, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump, Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County Twelve Mile Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, 73. for Alan W. Klimek, P.E. cc: Union County Health Department Mooresville Regional Office, Water Quality Section (WVVTF Permit No. NC0085359) Marc Houle, Yarbrough -Williams & Houle, Inc. Water Quality Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and [imitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 12th day of October, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 0,/27z . � for Alan W. Klimek, Pr E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024444 3 Fast Track Engineering Certification Permit No. WQ0024444 October 12, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Lawson Subdivision, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS ' MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shalt be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. RACK APPLICATION for GRAVITY SEWE USE THE TAB KEY TO MOVE FROM FI ......................... Owner' Union County Public Works Full Legal Name (company, mun z ib. Mr. JonC. Dyer, P.E., Director Signing Official Name and Title (Please revi lc, The legal entity who will own this system is: ❑ individual ❑ Federal ❑ Municipality d. 400 North Church Street Street Address Z 0 1 h. 764296-4212 Telephone 2. Project (Facility) Information: 2a, Lawson (,.PUMP STATIONS, AND FORCE MAINS ............... Applicati (to be completed by 5A NCAC 2H .02 b) hoed signing officials!) PAGE 3 44 e/County ❑ Private Partnership Corporation ❑ Other (specify): 764-296-4232 Facsimile Brief Project Name (permit will refer to this name) 3, Contact Person: le. Monroe City g. 28112-4804 Zip Code j jondyer©co.union, nc.us E-mail 2b. Union County Where Pro t is Located 3a. Charlie O'cain, PfE., Deputy Director Name and .Affiliation of Someone Who Can Answer Questions About this Appi cation 3b. 704-296-4214 Phone Number 3c, O'cain@co,union,nc.us E-mail 1. Project is ► New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application do not duplicate project information in B(7) and B(1O-11) that has already been included in the original permit. 2. Owner is. rsf Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, faciliti p Retaining Ownership (Le, store, church, single office, etc.) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc, - go to item B(2b)) 3. Union Co. Public Works Department Owner of Wastewater Treatment Facili 4a. Twelve Mile Creek Name of WWTF 5a. Union Co, Public Works Dept, 5b, Owner of Downstream Sewer The origin of this wastewater is (check Residential Subdivision ❑ Apartments/Condominiums El Mobile Home Park ❑ School El Restaurant El Office s owned by a (must choose one ❑ Public Utility. (Instruction Ill) ❑ Homeowner Assoc./Developer. (Instruction IV) (WWTF) Treating Wastewater From This Project 36' Receiving S l' tfaat apply): El Car Wash ❑ institution • Hospital ❑ Church El Nursing Home ❑ Other (specify): 7. Volume of wastewater to be permitted in this project: 126,000 gallons per day 411 NC0085359 WWTF Permit No. WQ0012167 e Permit Number of Downstream Sewer 00 % Domestic/Commercial % industrial % Other (specify) 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected --'WRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 B. PERMIT INFORMATION (CONTINUED) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). (3 bedroom) x (120 gpd) x (350 lots) = 126,000 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 12' 992 Gravity 8' 23,267 Gravity ENTER TOTAL LINE LENGTH IN MILE 4.60 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on plans for cross-reference) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (1- dual line feed; 2- permanent generator w!ATS; 3- generator w!telemetry; 4-wet well storage) _portable 12. Does the sewer system comply Mains (latest version), the with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Gravity Sewer Minimum Design Critena (latest version) and 15A NCAC 2H .0200 as applicable? reference the pertinent minimum design criteria or regulation and indicate why a is requested: SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION ►mot Yes • No If no, please variance SUBMIT TWO COPIES OF PLANS, 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ►mow Yes • No ❑ N/A Stormwater? ■ Yes • No 0 NIA Fir- _, :CI( APPLICATION for G V i S 0 gning Official Signature Professional Engineers C PU STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMSr to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, Location ID on Map (self chosen - as shown on map for cross-reference) Lawson Name of Waterbody East Fork Twelve r,nmok County Union VVaterbody Stream Waterbody River Basin Index Classification Catawba 11-138-2 Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless a whether a classification is provided! 1. Applicant's Certification: I, Jon C. Dyer , attest that this application for Lawson has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who ' kftowingly makes any false statement, moment tion, or certification in any application shall be guilty of a Class 2 isdemeanor which may include a fine not to e d $10,000 as well as civil penalties up to $25,000 per violation. 7/117. Date I attest that this application for Lawson has been reviewed by me and is accurate, com e and consistent with the information in the engineering plans, calculations, and all other supporting documentation to he best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sevvers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my sig nature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC Genera/ Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,' representation, or certification in any application shall be guilty of a Glass 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation 2a.. Marc A_ Houle, P E Professional Engineer Name 211 Yarbrough -Williams & Houle, Inc. Engineering Firm 2c, P.O. Box 7007 Address 2d Charlotte City 2g. 704-556-1990 ielephone 2e NC 2f 28273 ,2h. 704-556-0505 Facsimile State Zip 2i, Marc y-wh.com E-mail Seal, Signature & D te •I970 DMA 4853 I r4W-SERIES V842 10/12/04 Permit Number WQ0024444 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.williams Permitted Flow 126000 Facility Fast Track Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Lawson Subdivision Location Address Owner Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County DateslEvents Owner Type Government - County Owner Affiliation John Dyer 400 N Church St Monroe NC 28111 Scheduled Qrig Issue App Received Draft Initiated Issuance 10/04/04 Regulated Activities Public Notice Issue Effective I Oil 2104 Requested/Received Events Subdivision Wastewater collection Duffel] NULL Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resourc Mooresville Regional Office 919 North Main Street Mooresville, N.C. 28115 Attention: Regarding: Lawson Subdivision We are sending you: T. Copy of letter Li Plans Prints Shop drawings Other TRANSMITTAL AONMENT mate 1 No. Description 9/29/04 9/29/04 9/23/04 Original Non Discharge Permit. Application opy of Non Discharge Permit Application Check for $400 00 (Application Fee) These are transmitted as checked below:. For approval 0 For your use As requested Remarks: Signed: Date: 9/29/04 For review and comments Received by: ... Date:.