HomeMy WebLinkAboutWQ0024089_Regional Office Historical File Pre 2018T'u-
. FF rk Michael F. Easley, Governor
O
OG William G. Ross Jr.. Secretary
r North Carolina Department of Environment and Natural Resources
-i Alan W. Klimek, P,E., Director
Division of Water Quality
Coleen H. Sullins, Deputy Director
Division of Water Quality
Mr. Jon Dyer, Director of Public Works
Union County
400 North Church Street
Monroe, North Carolina 28112
July 6, 2004
Subject: Permit No. WQ0024089
Union County
West Fork Twelve Mile Creek Trunk Sewer
Phase 2
Wastewater Collection System Extension
Union County, North Carolina
Dear Mr. Dyer:
In accordance with your application received on June 21, 2004, we are forwarding herewith
Permit No. WQ0024089, dated July 6, 2004, to Union County for the construction and operation of the
subject wastewater collection system extension. This permit shall be effective from the date of issuance
until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover
letter shall be considered a part of this permit and is therefore incorporated therein by reference.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any
individual system -wide collection system permit issued to the Permittee.
Permitting of this project does not constitute an acceptance of any part of the project that does
not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum
Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable, unless specifically mentioned herein. Division approval is based on acceptance of the
certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be
the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design
criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General
Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater
collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing
board.
ATA
NCDENR
Mooresville Regional Once Internet http:/lh2o.enr.stale.nc.us/
919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040
DENR Customer Service Center Telephone 1 877 623-6748
Mr. Jon Dyer
Page 2
July 6, 2004
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby
granted to Union County for the construction and operation of approximately 25 linear feet of 42-inch
gravity sewer and approximately 4,447 linear feet of 36-inch gravity sewer to serve as a interceptor line
as part of the West Fork Twelve Mile Creek Trunk Sewer Phase 2 project, with no additional discharge
of collected domestic wastewater into Union County's existing sewerage system (flow will be permitted
in subsequent permits that connect to this line), pursuant to the application received June 21, 2004, and
in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted
February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data
subsequently filed and approved by the Department of Environment and Natural Resources and
considered a part of this permit.
The sewage and wastewater collected by this system shall be treated in the Union County's
Twelve Miie Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving
stream.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
If you need additional information conceming this matter, please contact Sonja Williams at (704)
663-1699.
Sincerely,
/2 /7r --°'7--,
for Alan W. Klimek, P.E.
cc: Union County Health Department
Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0085359)
William S. Riddick, McKim & Creed
Water Quality Central Files
NDPU Files
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically
mentioned herein.
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2H .0227. if an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H
.0227:
a. The sewer system shall be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan shall be developed and implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shall be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1 C.
1
4. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State.
6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a
copy of the construction record drawings, as well as supporting design calculations for any pump
stations permitted as part of this project shall be received from a North Carolina -licensed
Professional Engineer certifying that the facilities have been installed in accordance with this
permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12,
1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump
Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this
project is to be completed in phases and partially certified, you shall retain the responsibility to
track further construction approved under the same permit, and shall provide a final certificate of
completion once the entire project has been completed. A copy of the construction record
drawings, indicating the facilities constructed in the phase being certified, shall be submitted with
each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record
Drawings," and one copy of the supporting design calculations to the Department of Environment
and Natural Resources, Water Quality, 919 N. Main Street, Mooresville, NC 28115.
7. A copy of the construction record drawings shall be maintained on file by the Permittee for the fife
of the wastewater collection facilities.
8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215.6C.
9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities.
10. The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other govemment agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B .0200 and 15A NCAC 2H .0500.
2
1 i . Noncompliance Notification:
The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville
Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than
24 hours or on the next working day, following the occurrence or first knowledge of the occurrence
of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
Voice mail messages or faxed information is permissible, but shall not be considered as the initial
verbal report. Overflows and spills occurring outside normal business hours may also be reported
to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-
3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1
of Form CS-SSO (or the most current Division approved form), within five days following first
knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that
the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form)
can also be completed to show that the SSO was beyond control.
Permit issued this the 6th day of July, 2004.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
/4: ),-el-----2-,
for Alan W. Klimek, E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number W00024089
3
Fast Track Engineering Certification
Permit No. WQ0024089
July 6, 2004
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for anv changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division.
ENGINEER'S CERTIFICATION
❑ Partial ❑ Final
I, , as a duly registered Professional Engineer in the State of North Carolina, having
been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the West Fork Twelve
Mile Creek Trunk Sewer Phase 2, Union County project for the Permittee hereby state that, to the best of my
abilities, due care and diligence was used in the observation of the construction such that the construction was
observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water
Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June
1, 2000 as applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
WATER QUALITY
919 N. MAIN STREET
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
TV SEWERS, PUM1 STATIONS, .AND FORCE MAIN
USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Appli ation Number:(to be
1. Owner:
la. Union County Department of Public Works_
Full Legal Name (company, municipality, HOA, utility, etc,)
z lb. Jon C. Dyer,PE, Director, Union County Public Works
Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!)
lc, The legal entity who will own this system is:
0 Individuai 0 Federal 0 Municipality State/County 0 Private Partnership 0 Corporation 0 Other (specify):
mpleted by DWQ)
4
PAGE 3
Id. 400 North Church Street le. Monroe
0 Street Address City
LL. ;
Z If. NC 1g, 28112-4804
z State Zip Code
1 h. (704) 296-4210 li, 704-296-4232 1j, jondyer@co,union.nc.us
Telephone , Facsimile E-mail
•i2. Project (Facility) Information:
2a West Fork Twelve Mile Creek Trunk Sewer? Phase 2 2b. Union County
0
Brief Project Name (pemiit will refer to this name) County Where Project is Located
3. Contact Person:
3a, Charlie O'Cain, PE, Deputy Director
Name and Affiliation of Someone Who Can Answer Questions About this Application
3b. (704) 296-4214 3c. ocainfcounion.nc.us
Phone Number
E-mail
1. Project is New 0 Modification (of an existing permit) if Modification, Permit No.:
For modifications, attach a separate sheet dearly explaining the reason for the modification (i.e. adding another
phase, changing line size/length, etc.). Only include the modified information in this permit application - do not
duplicate project information in B(7) and B(10-11) that has already been included in the original permit.
2. Owner is Z Public (skip to Item B(3)) 0 Private (go to Item 2(a))
2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one)
0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Public Utility (Instruction III)
0 Leasing units (lots, townhomes, etc. - skip to item B(3)) 0 Homeowner Assoc./Developer (Instruction I
El Selling units (lots, townhomes, etc. - go to Item B(2b))
,3. Union Coun
E , Owner of tewater Treatment Facility (WWTF) Treat'
0 4a, Twelve Mile Creek WWTP
u_ NameofWWTF
Z 5a, Union County
Owner of Downstream Sewer
The origin of this wastewater is
Z Residential Subdivision
0 Apartments/Condominiums
0 Mobile Home Park
0 School
0 Restaurant
0 Office
astewater From This Projec
4b, NC0085359
WWTF Permi
5b, 42" 5c. WQ0018332
Receiving Sewer Size Permit Numb
check al! that apply):
El CarWash
0 Institution
0 Hospital
0 Church
0 Nursing Home
Other (specify):
No.
of Downstream Sewer (if known
7. Volume of wastewater to be permitted in this project: 0 gallons per day
% Domestic/Commercial
% Industrial
% Other (specify):
8, If the permitted flow is zero, indicate why:
Interceptor Line - Flow will be permitted is subsequent permits that connect to this line
O Flow has already been allocated in Permit No.
0 Rehabilitation or replacement of existing sewer with no new flow expected
FTA 07/111 - Rev 1
PLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4
9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H
.0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than
that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to
the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in
accordance with 15A NCAC 2H .0219(1)(3).
10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary)
Size (inches) Length (feet)
Gravity or Force Main
(use the pull down menu)
42 25 Gravity
36
4447 Gravity
ENTER TOTAL LINE LENGTH IN MILES 0.85
F" 111. Summary of Pump Stations to be Permitted (attach additional sheets as necessary)
a
Location ID Power Reliability Option
O (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3-
plans for cross-reference)_I (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage)
II
H '1 IF
O.
12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force
m Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?
® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a
variance is requested:
SUBIVIIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
113. Have the following permits/certifications been submitted for approval?
, Wetland/Stream Crossings - General Permit or 401 Certification?
Sedimentation and Erosion Control Plan?
Stormwater?
❑ Yes ® No
® Yes ❑ No
❑ Yes ® No
❑ N/A
❑ N/A
❑ N/A
FTA 02/03 - Rev. 1 06/03
. .PLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5
1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03
(FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as
necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality
regional office (see instructions for addresses) OR indicate the following:
0
0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down
waterbody; AND,
11J
091-
6
U)
z
0
d
lope
El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability
option for any pump station near a Class C down slope waterbody.
Location ID on Map
(self chosen - as shown on
map for cross-reference)
Trunk Sewer
Name of
Waterbody
West Fork Twelve Mile
Creek
County
Union
River Basin
Catawba
Waterbody Stream Waterbody
Index Classification
11-138-1
Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI
regardless of whether a classification is provided!
1. Applicant's Certification:
00-
I, Jon C, Dyer, PE, attest that this application for West Fork Twelve Mile Creek,Trunk Sewer has been reviewed by me
and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are
not completed and that if all required supporting documentation and attachments are not included, this application
package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-
215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any
application shall be guilty of a Class 2 misdemeanor w h may include a fine not to exceed $10,000 as well as civil
penalties up to $25,000 per violation,/ /
,
Signing Official Signature
2. Professional Engineer's Certificatip-rt
I attest that this application for West Fork Twelve Mile Creek Trunk Sewer has been reviewed by me and is accurate,
complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation
to the best of my knowledge. further attest that to the best of my knowledge the proposed design has been prepared in
accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February
12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June
1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal
package may have been developed by other professionals, inclusion of these materials under my signature and seal
signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, Note: In
accordance with NC General Statutes 143-215.6A and 143-215,68, any person who knowingly makes any false statement,
representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to
exceed $10,000 as well as civil penalties up to $25,000 per violation.
2a, William S. Riddick, PE
Professional Engineer Name
2b. McKim & Creed
Engineering Firm
2c. 2300 Sardis Road N. Suite A
Address
2d Charlotte
City
2e. NC 2f. 28227
State Zip
29. 704-841-2588 2h. 704-841-2567 21. sriddick@mckimcreed.com
Telephone Facsimile E-mail
Fr A 0203./- Re, 1 06/03
Name, CATW BA NE
Date: 6/8/2004
Scale: 1 inch equals 1333 feet
Location: 034' 58' 54.7" N 080' 45' 04.4" W
Caption: West Fork Twelve Mile Creek
Interceptor Sewer
Maptech, Inc.
07/01/04
Permit Number
WQ0024089 Permit Tracking Slip
Program Category
Non -discharge
Status Project Type
In review New Project
Permit Type F`'sl ir`iek, Version Permit Classification
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual
Extensions
Primary Reviewer Permit Contact Affiliation
sonja.williams
Permitted Flow
0
Facility
Facility Name Major/Minor Region
West Fork Twelve Mile Creek Trunk Sewer Phase Minor Mooresville
2
Location Address County
Union
Owner
Facility Contact Affiliation
- Owner Name Owner Type
Union County Government - County
Owner Affiliation
John Dyer
400 N Church St
Monroe
Dates/Events
Scheduled
Orig Issue App Received Draft Initiated Issuance
06/21/04
Public Notice Issue
NC 28111
Effective Expiration
Regulated Activities Requested/Received Events
Subdivision
Wastewater collection
Outfall NULL
Additional information requested
Additional information received
Waterbody Name Stream Index Number
Current Class Subbasin
UNION COUNTY PUBLIC WORKS
400 N. Church Street
Monroe, NC 28112-4804
704/296-4210
Fax 704/296-4232
To: NC Department of Environment and Natural Resources
Mooresville Regional Office
919 North Main Street
Mooresville, N.C. 28115
Attention:
D;_RA�,5M/TTAL
ANC1Oa" : SOURCES
DFFICE
JUN 2 1 2004
Date: 6/17/04
Regarding: Sanitary Sewer to serve West Fork of Twelve Mile Creek Trunk Sew rr,(Phase 2
We are sending you: ❑ Copy of letter ❑ Plans ❑ Prints ❑ Shop Drawings
® Other
Copies
Date
No.
Description -
1
6/8/04
Original Non Discharge Permit Application
1
6/8/04
Copy of Non Discharge Permit Application
1
6/14/04
20227
Check for $400.00 (Application Fee)
These are transmitted as checked below:
® For approval ❑ For your use ❑ As requested ❑ For review and comments
Remarks:
Signed: (,0
Received by: - Date:
Fast Track Engineerint Certification
Permit No, WQ0024089
July 6, 2004
Complete and submit this form to the permit issuing regional office with the following;
One copy of the project record drawings (plan & profile views of sewer Vines) of the wastewater collection
system extension
supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
Changes to the project should be clearly identified on the record drawings or in written summary form, Permit
modifications are re wired for an chap es resultin in non-com !lance with this permit, regulations or
r2irtimum design criteria,
Or
be se
vides proof of recei
ly recOm vended
ENGINEERS CERTIFICATION
,s ElPartial rtit Final
1, 101II,Rlr+ 7 ras a duly registered Professional Engineer in the State of North Carolina, having
been authorized to observe ( periodically, 0 weekly, 0 full time) the construction of the West Fork Twelve
Mile Creek Trunk Sewer Phase 2, Union County project for the Permittee hereby state that, to the best of my
abilities, due care and diligence was used in the observation of the construction such that the construction was
observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200, the Division of Water
Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the
Division'sWMinimurn Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June
1, 200E as applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date;
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
WATER QUALITY
919 N. MAIN STREET
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
UNION COUNTY PUBLIC WORKS
400 N. Church Street
Monroe, NC 28112-4804
704/296-4210
Fax 704/296-4232
To: Mooresville Regional Office
Water Quality
610 East Center Ave. Suite 301
Mooresville NC 28115
Attention: Dee Browder
TRANSMITTAL
Date: 11/10/05
Regarding: Record Drawings and Engineer's Certification for Sewer to serve West Fork 12-Mile
Creek Trunk Sewer, Phase 2 (Final Certification)
We are sending you: ❑ Copy of letter ® Plans El Prints ❑ Shop Drawings
® Other
Copies
Date
No.
Description
1
11/7/05
Engineers Certification for Sewer (WQ0024089)
This certification supersedes certification dated 10/17/05
These are transmitted as checked below:
❑ For approval ® For your use ❑ As requested ❑ For review and comments
Remarks:
Signed:
Received by: Date:
Permit No. WQ0024089
October 17, 2005
ENGINEER'S CERTIFICATION
❑ Partial ® Final
1, William S. Riddick, Jr., PE , as a duly registered Professional Engineer in the State
of North Carolina, having been authorized to (® periodically, ❑ weekly, ❑full
time) observe the construction of the West Fork Twelve Mile Creek Trunk Sewer
Phase 2, Wastewater Collection System Extension, Union County, North
Carolina,), for the Permittee hereby state that, to the best of my abilities, due
care and diligence were used in the observation of the construction such that
the construction was observed to be built within substantial compliance of this
permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity
__ .Sewer Minimum Design Criteria adopted February 12, 1996 as_applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations
and Force Mains adopted June 1, 2000 as applicable; and other supporting
materials.
North Carolina Professional Engineer's seal, signature, and date.
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS:
MOORESVILLE REGIONAL OFFICE
610 EAST CENTER AVE, SUITE 301
MOORESVILLE, NC 28115-0950