Loading...
HomeMy WebLinkAboutWQ0024035_Regional Office Historical File Pre 2018Michael F. Easley, Govemor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality Mr. Jon Dyer, Director of Public Works Union County 400 North Church Street Monroe, North Carolina 28112 June 28, 2004 Subject: Permit No. WQ0024035 Union County Lester Davis Subdivision Wastewater Collection System Extension Union County, North Carolina Dear Mr. Dyer: In accordance with your application received on June 18, 2004, we are forwarding herewith Permit No. WQ0024035, dated June 28, 2004, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Ara IMENR Mooresville Regional Office Internet httpJlh2o.enr.state.nc.usf 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr. Jon Dyer Page 2 June 28, 2004 in accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County for the construction and operation of approximately 12,228 linear feet of 8-inch gravity sewer to serve 205 single family residences, a 500 person swimming pool and cabana as part of the Lester Davis Subdivision project, and the discharge of 78,800 gallons per day of collected domestic wastewater into Union County's existing sewerage system, pursuant to the application received June 18, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Cri,teria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County's Twelve Mile Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Union County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0085359) Anthony Gaffey, insite Engineering & Surveying Water Quality Central Files NDPU Files f NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date .of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at ail times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC. 2E_..0200 or the surface water standards in 15A NCAC 2B .0200. A map of the sewer system shall be developed and shall be actively maintained. An operation and maintenance plan shall be developed and implemented. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. High -priority sewer lines shall be inspected at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted at least once per year. Inspection and maintenance records shall be maintained for a period of at least three years. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. a. b. c. d. e. f. 9. h. pr, 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6., Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Department of Environment and Natural Resources, Water Quality, 919 N. Main Street, Mooresville, NC 28115. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collectiori facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 r ncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 28th day of June, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P. ., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024035 3 r ack Engineering Certification o. WQ0024035 June 28, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project snail not be consiaerea complete nor allowec to operate until this Engineer's Certification ano all requirea supporting aocumentation have peen receivea by the Division. Therefore. it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Lester Davis Subdivision, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this -permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE WATER QUALITY 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FRO FIELD TO FIELD! Application Number: (to be completed by DWQ) \Ai 62002-403 Owner: 11a. Union County Public Works Department Full Legal Name (company, municipality, HOA, utility, etc. b. Jon C. Dyer,P.E., Director of Public Works igning Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorizedsigning officials!) The legal entity who will own this system is: 0 Individual Ej Federal 0 Municipality (El State/County 0 Private Partnership 0 Corporation 0 Other (specify): d. 400North Church Street •Ii3. Monroe Street Address ! City i f. NC lg. -281124804 State , Zip Code 704-296-4210 1L 704-296-4232 1j. jonDyer@Co.Union.NC.US Telephone Facsimile E-mail Project (Facility) Information: 2b, Union . Lester Davis Subdivision Brief Project Name (permit will refer to this name) Contact Person: Charles P. 0' cain, , T)eputy Director of Public Works Name and Affiliation of Someone Who Can Answer Questions About this Application b. (704) 296-4214 o cain@co.union.nc .us Phone Number E-mail County Where Project is Located Project is New 0 Modification (of an existing permit) If Modification, Permit No.: . Owner is Public (skip to Item B(3)) El Private (go to Item 2(a)) a, If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (Le. store, church, single office, etc. O Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc, - go to Item B(2b)) • Uron_CounyflicWorks Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project a. 12 Mile Creek Waste Water Treatment Plant 4b. NC0085359 0 Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) Name of WWTF WWTF Permit No. . Union County Public Works 5b. 24°' & 30" 5c. WQ0023998 Owner of Downstream Sewer Receiving Sewer Size i Permit Number of Downstream Sewer (if known The origin of this wastewater is (check all that apply): , ... Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park El School El Restaurant 0 Office 0 Car Wash 0 Institution 0 Hospital 0 Church 0 Nursing Home O Other (specify): Volume of wastewater to bepermitted in this project: 78,800 gallons per day --- If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected % Domestic/Commercial % Industrial % Other (specify): PLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 120 gal/day x 3 bedrooms x 205 single family homes = 73,800 plus 10gallperson x 500 person pool and cabana = 5,000 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) 12228 Gravity or Force Main (pull down menu) Gravity Gravity Gravity ENTER TOTAL LINE LENGTH IN MILES 2.32 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID as shown on plans) Design Flow (MGD) Operational Point GPM @ TDH Gravity Gravity Gravity Gravity Power Reliability Option (dual line feed, permanent generator w/ATS, portable generator w/telemetry, wet well storage) '12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ® Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? ® Yos ❑ No 0 N/A Stormwater? ® Yes ❑ No ❑ N/A FTA 02/03 PPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Z ' 1. Use the Division's guidance (FAST -TRACK SEWER necessary). This document regional office (see instructions document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as is available from our web site or by contacting the appropriate Division of Water Quality for addresses) OR indicate the following: H is not needed because all parts of the project are at least 100 feet away from any down slope • A Stream Classification waterbody; AND, LL • A Stream Classification option for any pump Location ID l on Map_ ! is not needed station near a Name of Waterbody Fork of Twelve mile Creek because the design Class C down slope County Union does not depend waterbody. River Basin Catawba on Waterbody wet well storage as a power reliability Stream ' I Waterbody Index Classification N ' J 1 lWest 11-138-1 C ' w., I v : Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1, Jon C. Dyer, P.E, attest that this application for Lester Davis Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. ! understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdem nor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per viol ion. . ‘#' i.di_--- Signing Official Signature !Ate Z . Professional Engineer's Certification: I attest that this application for L ester Davis Subdivision accurate, complete and consistent with the information in the documentation to the best of my knowledge. ! further attest been prepared in accordance with the applicable regulations, adopted February 12, 1996, and the -Mini -mum- Design Criteria Mains adopted June 1, 2000 and the watershed classification portions of this submittal package may have been developed signature and seal signifies that ! have reviewed this material Note: In accordance with NC General Statutes 143-215.6A statement, representation, or certification in any application fine not to exceed $10,000 as well as civil penalties up to Anthony R. Gaffey, P.E. has been reviewed by me and is engineering plans, calculations, and all other supporting that to the best of my knowledge the proposed design has Gravity Sewer Minimum Design Criteria for Gravity Sewers for the Fast -Track Permitting of Pump Stations and Force in accordance with Division guidance. Although certain by other professionals, inclusion of these materials under my and have judged it to be consistent with the proposed design. and 143-215.6B, any person who knowingly makes any false shall be guilty of a Class 2 misdemeanor which may include a $25,000 per violation. V_-- - LL Lill : iJ _ =ARGAFFEY@INS1TEengineeri ,`,�oH GAR N,,,0,/ . �. 'i�` O�y /0 ti`� Qp1' 0 9 �0 — — j2a. Professional Engineer Name b.1NSITE Engineering & Surveying Engineering Firm 2c. 8041 Corporate Center Drive, Suite 200 Address 2d. Charlotte '2e. NC 2f. 28226 - ` t904 " .` ir�if+O %IT" •'� lime*�� �,� S Si natu Date City I State Zip 2g. 704-540-4706 2h. 704-540-4708 21. �m Telephone Facsimile FTA 02/03 ozone.�� r f klabaf%, knF u ..1 r., T••.1 `f k': 11 ��—`ra..� nO rite t�, f! . I 0 0,3 0.6 0.9 t.2 0 0.2 0.4 0.6 0.6 Map center is UTM 17 524856E 3873265N (WGS84/NAD83) Matthews quadrangle Projection is UTM Zone 17 NAD83 Datum • 1 M=-7.098 G=0.156 06/18/04 Permit Number WQ0024035 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual Extensions Primary Reviewer Permit Contact Affiliation sonja.williams Permitted Flow 78800 Facility Facility Name Lester Davis Subdivision Location Address Owner Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affiliation John Dyer 400 N Church St, Monroe NC 28111 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective 06/18/04 %l 104 Regulated Activities Requested/Received Events Subdivision Additional information requested Wastewater collection Additional information received Outfall NULL Expiration Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 919 North Main Street Mooresville, N.C. 28115 Attention: Regarding: Lester Davis Subdivision We are sending you: Copies Date H, Copy o Other No. 6/8/04 6/8/04 6/10/04 ever Description 7331 ITTAL ES 2004 Date: 6/15/04 A ER UAL SEC ON Plans (i Prints i Shop Drawings Original Non Discharge Permit Application Copy of Non Discharge Permit Application Check for $400.00 (Application Fee These are transmitted as checked below: For approval —1 For your use 0 As requested j 1 For review and comments Remarks: Received by: Date: UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: Mooresville Regional Office Water Quality 610 East Center Ave. Suite 301 Mooresville NC 28115 Attention: Dee Browder TRANSMITTAL Date: 1/26/06 Regarding: Record Drawings and Engineer's Certification for Sewer to serve Lester Davis Subdivision (Renamed Hollister) (Partial Certification) (Lots 119-126, 152-194 and 200-205) We are sending you: Copies Date Copy of letter Plans 1 Prints 0 Shop Drawings Other No. /17/06 /17/06 Description Record Drawings Engineers Certification for Sewer (W+C0024035) These are transmitted as checked belo 0 For approval Remarks: Signed: For your use LI As requested El For review and comments Received by: Date: st Track En • ineerin • Certification Permit No. W00024035 June 28, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be dearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. Lo'fs: llq- tZCo 15Z- 1941 ZOO - Z. ENGINEER'S CERTIFICATION Partial El Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (X periodically, ❑ weekly, ❑ full time) the construction of the Lester Davis Subdivision, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: ‘‘ Cgpct 4r)Y- ASS/Q'� ego _ 1 S Ca`d ,`,'r,tit''`,O 67 SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE WATER QUALITY 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Fast Track Engineering Certification Permit No. WQ0024035 June 28, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be dearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered cornplete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION A114 i-Fy ElPartial ❑ Final � •� '-L%�� 1, 4! 0/t / 4' y, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Lester Davis Subdivision, Union County project for the Permittee hereby state that, to the best of my abilities, due care and. diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: „%%` yi GAP°,ig o i_ SEA R. e)..c% .00 • O SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE WATER QUALITY 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment & Natural Resources Mooresville Regional Office 919 North Main Street Mooresville, N.C. 28115 Attention: Dee Browder TRANSMITTAL Date: 7/24/07 Regarding: Engineer's Certification for Lester Davis S/D (Hollister - Amenity) Partial We are sending you: ❑ Copy of letter ❑ Plans ❑ Prints ❑ Shop Drawings ® Other Copies Date No. Description 1 7/18/07 Record Drawings 1 7/18/07 Engineer's Certification for Sewer (Permit # WQ0024035) tr..r 1. Vt Clr ' "A'Y,i-1ti, AND NATURAL MOORESVILLF ReO ..• IA 4. JUL - 17 ►: ; These are transmitted as checked below: WATER QUALITY HMO ['For approval ® For your use ❑ As requested ❑ For review and comments Remarks: Signed: ICY Received by: Date: Fa t Track Engineering Certific bran Permit No. WQ0024035 June 28, 2004 Complete and submit this form to the per issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with his permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. been authorized to observe ENGINEER'S CERTIFICATION Partial "�! Final s a duly registered Professional Engineer in the State of North Carolina, having periodically, © weekly, D' full time) the construction of the Lester Davis Subdivision, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE WATER QUALITY 919 N. MAIN STREET MOORESVILLE NC 28115 // 07 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Ms. Dee Browder TRANSMITTAL Regarding: Engineer's Certification for Hollister SID (Formerly Lester Davis) Date: 2/11/13 We are sending you: © Copy of letter �' Plans 0 Prints 0 Shop Drawings Other Copies Date No. Description 1 6 6/07 Record Drawings Engineer's Certification for Sewer (Permit t#WQ0024035) These are transmitted as checked belo D For approval Remarks: Signed: Received by: For your use fl As requested El For review and comments Date: