Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0023478_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality December 6, 2007 Ms. Christie Putnam, P.E., Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Subject: Permit No. WQ0023478 Modification Shannon Vista Subdivision Wastewater Collection System Permit Union County Public Works Union County, North Carolina Dear Ms. Putnam, In accordance with your application received on November 20, 2007, we are forwarding herewith Permit No. WQ0023478, dated December 6, 2007, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave„ Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper Npne r Caroliru 7atura!!y Ms. Putnam Page2 December6,2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 10,546 linear feet of 8-inch gravity sewer and the discharge of 67,880 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received November 20, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County's Twelve Mile Creek WVVfP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Andrew Litten, R. Joe Harris & Associates, PLLC Surface Water Protection Central Files PERCS I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 1l of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 6th day of December, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023478 Modification 3 Fast Track Engineering Certification Permit No. WQ0023478 Modification December 6, 2007 OwneriWVVfPIWQCS PE Christie Putnam Andrew Litten Union County Public Works R. Joe Harris & Associates, PLLC 400 North Church Street 1698 W. Harris & Associates, PLLC Monroe, NC 28112 Fort Mill, SC 29708 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Shannon Vista Subdivision, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. TRACK APPLICATION for GRAVf°3r SE y4I RS, Ptll P STATIONS, AN ,FORCE MAINS Application Number: (ta be completed by G3WVQ) .^ 7. 0 la Un rzn Coun: 1 ,blic. Works Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Christie L. Putnam, P.E. - - Directorof 'Public Works Signing Official Name and Title (Please review 1A NCAC 2H The origin of 0 Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Parr ❑ School 0 Restaurant 0 Office z 0 1- 2 lc, The legal entity, who will own this system is: ❑ Individual ® Federal E1 Municipality ®' State/County 0 Private Partnership ❑ Corporation [] Other (specify): 4 ld. 5 C C ▪ Mailing Address NC PAGE a z 0 the e (7r34) 296-4210 Telephone N. Main Street, Suite 50C (7041 Fa 2. Project(Facility) Information. 2a Shannon Vista Subdivtsi,n t3. Brief Project Name (permit Mill refer to this name CL 4( 3. Contact Person: 4i 3a, Mike Garbark, PE - Ass Name and Affiliation of Someon (704) 29 -4239 3b. Phone Number er authorized signing officials!) le. Monroe City 01:1.2 Zip Code 1j cputnamlcu.usliononc,ua E-mail 2b Un i ern County Where Project is Located t. Director of Public' Works 'ho Can Answer Questions About this Application 3c. mikegarbar°ks;a,c . union. n :.11 E-mail 1, Project is'0 New ® Modification (of an existing permit) If Modification, Permit No.. WQ0(S2347t3 For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line sizellength, etc.). Only include the modified information in this permit application - do not duplicate project information in .>;7) and B(10-11) that has already been included in the original permit. 2 Owner is El Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 0 Retaining Ownership (i.e. store, church, single office„ etc.) or [] Leasing units (lots„ townhomes, etc - skip to Item B(3)) © Selling units (lots, townhomes„ etc. - go to item B(2b)) k7az1on County Public Works 2b, if sold, facilities owned by a Q Public L, H orn eo choose one) (Instruction III) r Assoc. /Developer (Instruction IV) Owner of Wastewater Treatment Facility ( rF) Treating Twelye Name of WWTF Pub": ic: cork,, 5b, 24 " 0 Gravity ewer Receiving Sewer Size Q Force Main er is (check all that apply). ater From This Project 4b, NC0085359 Permit No. WQ0014152.. _ .. .. Permit Number of Downstrea rl Car Wash O Institution O Hospital '[] Church © Nursing Home Ej Other (specify)- 6; lubhooee,7"Pool Volume of wastewater to be allocated for this particular project *Do not include previously permitted allocations Sewer (if known) 100 % Domestic/Commercial Industrial % Other (specify): ons per day If the permitted flow is era, indicate why El Interceptor Line - Flow will be permitted in subsequent permits that connec 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected o thi Inc l�tA022U3 - .Re .3(14 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 • NFORMATION (CONTINUED) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). tD 272 people/day 10 gal/person = 2,720 gal/day dr X ap 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) / COC ! avity or Force Maid Size (inches) Length (feet) (use the pull down menu) (no additional lines) ENTER TOTAL LINE LENGTH IN MILES (total = 10,546 LF) 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator wlATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage) 1- 2 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Ce Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable'? W x❑ Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION m 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certitication? El Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ® Yes D No ❑ N/A 14. Does this project involve aerial lines or siphons? Check if yes: El These lines will be considered high priority and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? D 6e aware that the Division will not accept installed lines more than 1O% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 RACK APPLICATION for Cl wry SE7 P S'AT IONSk A.N t FORCE MAINS PAGE 5 • 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 2 0 0 A Stream Classification is not needed because all parts waterbody, AND, E A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on rnap for cross-reference) 34080-H6-0'F=-024 3408 H6-TF-024 Narne of Waterbody 1 e. Twelvz Tweiv't' Mile Cr County Union e project are at least 100 feet away from any down slope River Basin Catawba. Catawba Waterbody Stream index 11-138-2-3 11-138 Submit the 8,5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Waterbody Classification r_ Ap ONl nt° l hfic lion: i, Christie I, Putnam , attest that this application for PROJECT NAME : Shannon Vista has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-21'56B, any person who knowingly makes any false statement, representation, or tion in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 s civil penaties/up tor2„ d00 per vrolatien. Sgnin Professional Engineer's Certification: Date l attest that this application for Sh 1a3cf Vista Subdivision has been reviewedby me and is accurate, complete and consistent with the information in the engineering plans, calculations, and aff other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Critena for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design Note. in accordance with NC General Statutes 143-215.6A and 143-215.6a any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. Andrew K. n, P.E. Professional Engineer Name 2be R. Joe Harris. & Associates, PT IOC. Engineering Firm 2c. 1698 Wf Hwy 160, Suite 130 Mailing Address 2d, Fort Mill 2e. sc 29708 City State Zip 2g {803) 802m1799 2h (803) 802-0886 Telephone Facsimile E-mail Seal, Signature & Date 'TA 02103 - Rev, 43 04105 BO ' 43 , OOC WAXNAW, NC QUADRANGLE ➢diaJa raeatpd suit 34°SetJ° ROa41.721' W WGSE4 00 W Y+aGSB & 131)c"40 OU,C VV. UNION COUNTY PUBLIC WORKS 500 Nm Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 TRANSMITTAL Attention: NC Di 07 Regarding: Sanitary Sewer to serve Shannon Vista Subdivision We are sending you: 0 Copy of letter Plans 0 Prints 0 Shop Drawings Other Cop• ies Date No. Description Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application Check for $480 00 (Application Fee) These are transmitted as checked below: For approval 0 For your use 0 As requested 7 For review and comments Remarks: Signed: Received by: Date: ' Central Files: APS SWP 12/06/07 Permit Number WQ0023478 Permit Tracking Slip Program Category Status Non -discharge Active Project Type Major modification Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.10 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 67880 Facility Facility Name Shannon Vista Subdivision Location Address Owner Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Dates/Events Orig Issue App Received 01/07/04 12/06/07 Regulated Activities Subdivision Wastewater collection Outfall NULL Draft initiated Scheduled Issuance Owner Affiliation Christine Putnam, Director Interim 500 N Main St Ste 500 Monroe NC 281124730 Public Notice Issue Effective Expiration 12/06/07 12/06/07 ReauestedlReceived Events Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin Fast Track Engineering Certification Union County Public Works 400 North Church Street Monroe, NC 28112 Permit No, W00023478 Modification December 6, 2007 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are re uired for any than es resultin in non -co fiance with this ermit re utations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Final I, Patrick Lee Murphy, P.E., as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, 0 weekly, 0 full time) the construction of Shannon Vista Subdivision, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: (Certiflca2 Map 3 - Lots 47-67 & 96-99, and line segments [MH42 to MH43][MH43 to MH44][MH44 to MH 45][MH45 to MH46]IMH46 to MH471 & [MH47 to MH19] which includes sewer service to lots 68-71 & 81-95) SEND THIS FORM & SUPPORTING DOCUMENTATION REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS 7 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to co pletion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232. To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Dee Browder Regarding: Engineer"s Certification for Shannon Vista We are sending you: Copy of fetter ® Plans Other Copies Date No. Description Record Drawings Engineers Certification for Sewer (Permit # WQ0023478) TRANSMITTAL Date: 6/17/14 Prints C Shop Drawings These are transmitted as checked below: For approval ® For your use EJ As requested C For review and cornen Remarks: Signed: Received by: Date: Fast'Erack`Engineerinct Certification Union County Public Works 400 North Church Street Monroe, NC 28112 Permit No. WQ0023478 Modification December 6, 2007 Complete and submit this form to the permit issuing regional office with the following; One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION EJ Partial Final 1, Patrick Lee Murphy, P.E., as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, Li weekly, © full time) the construction of Shannon Vista Subdivision, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track. Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: A ad SEND THIS FORM & SUPPORTING DOCUMENTATION REQUIRE© ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Dee Browder Regarding: Engineer"s Certification for Shannon Vista. TRANSMITTAL Date: 8/4/14 We are sending you: Q Copy of letter Plans Prints P Shop Drawings Other No. j Description Record Drawings Engineer's Certification These are transmitted as checked below: For approval Remarks: Signed: Received by: For your use I l As requested D For review and comments Date: