HomeMy WebLinkAboutWQ0023044_Regional Office Historical File Pre 2018CoF��F9 Michael F. Easley, Governor
PG William G. Ross Jr., Secretary
r North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E., Director
September 8, 2003
Mr. Jon Dyer, Director of Public Works
Union County
400 N. Church Street
Monroe, North Carolina 28112
Division of Water Quality
Coleen H. Sullins, Deputy Director
Division of Water Quality
Subject: Permit No. WQ0023044
Union County
Bonds Grove
Wastewater Collection System Extension
Union County
Dear Mr. Dyer:
In accordance with your application received on September 5, 2003, we are forwarding herewith
Permit No. WQ0023044, dated September 8, 2003, to Union County for the construction and operation
of the subject wastewater collection system extension. This permit shall be effective from the date of
issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This
cover letter shall be considered a part of this permit and is therefore incorporated therein by reference.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any
individual system -wide collection system permit issued to the Permittee.
Permitting of this project does not constitute an acceptance of any part of the project that does
not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum
Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable, unless specifically mentioned herein. Division approval is based on acceptance of the
certification provided by a North Carolina -licensed Professional Engineer in the application.. It shall be
the Pemiittee's responsibility to ensure that the as -constructed project meets the appropriate design
criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General
Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater
collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing
board.
AAA
NCDENR
Mooresville Regional Office Internet http:/Ih2o.enr.state.nc.ust
919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040
DENR Customer Service Center Telephone 1 877 623-6748
Mr. Jon Dyer
Page 2
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby
granted to Union County for the construction and operation of approximately 4,477 linear feet of 8-inch
gravity sewer to serve 84 three -bedroom residences as part of the Bonds Grove project, and the
discharge of 30,240 gallons per day of collected domestic wastewater into Union County's Twelve Mile
Creek WWfP (NPDES No. NC0085359) existing sewerage system, pursuant to the application
received September 5, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable; and other supporting data subsequently filed and approved by the Department of
Environment and Natural Resources and considered a part of this permit.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
If you need additional information concerning this matter, please contact Sonja Williams at (704)
663-1699.
Sincerely,
for Alan W. Klimek, P.E.
cc: Union County Health Department
Mooresville Regional Office, Water Quality Section (WVVfF Permit No. NC0085359)
Steven Wilson, DPR Associates, Inc.
Water Quality Central Files
NDPU Files
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically
mentioned herein.
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2H .0227., If an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H
.0227:
a. The sewer system shall be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
16A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200.
b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively
maintained.
c. An operation and maintenance plan shall be developed and implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shall be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1C.
4. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State_
6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a
copy of the construction record drawings, as well as supporting design calculations for any pump
stations permitted as part of this project shall be received from a North Carolina -licensed
Professional Engineer certifying that the facilities have been installed in accordance with this
permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12,
1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump
Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this
project is to be completed in phases and partially certified, you shall retain the responsibility to
track further construction approved under the same permit, and shall provide a final certificate of
completion once the entire project has been completed. A copy of the construction record
drawings, indicating the facilities constructed in the phase being certified, shall be submitted with
each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record
Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting
Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617.
7. A copy of the construction record drawings shall be maintained on file by the Permittee for the fife
of the wastewater collection facilities.
8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215.6C.
9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities.
10. The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other government agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B .0200 and 15A NCAC 2H .0500.
1. Noncompliance Notification:
The Permittee shall report by telephone to the Mooresville Regional Office, telephone number
(704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working
day, following the occurrence or first knowledge of the occurrence of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five days following first knowledge of the occurrence. This report must outline the actions taken or
proposed to be taken to ensure that the problem does not recur.
Permit issued this the 8th day of September, 2003.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
for Alan W. Klimek,;iE., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0023044
Fast Track Engineering Certification
Permit No. WQ0023044
September 8, 2003
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for anv changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division.
ENGINEER'S CERTIFICATION
❑ Partial ❑ Final
1, , as a duly registered Professional Engineer in the State of North Carolina, having
been authorized to observe (0 periodically, ❑ weekly, ❑ full time) the construction of the Bonds Grove, Union
County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in
the observation of the construction such that the construction was observed to be built within substantial
compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum
Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -
Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting
materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
919 N. MAIN STREET
MOORESVILLE NC 28115
The Permittee is responsible for tracking ail partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3
USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI i Application Number: �y
(to be completed by DWQ) W Q00 z 30444-
O_wner: _ _ _ __ _ _ __ _ _ ___ _ ---- ___
a. UNION COUNTY PUBLIC WORKS DEPARTMENT--------------_--~�^•----------•--� -_ -
Full Legal Name (company, municipality, HOA, utility, etc.)
^1 b. JON C. DYER, PE - DIRECTOR
Signing Official Name and Title (Please review 15A NCAC 2H A206(b) for authorized signing officials!)
iI1 c. The legal entity who will own this system is:
■ Individual •■ Federal •■ Munici ali State/County ❑ Private Partnership: oration ■ Other s eci
_
`1d. 400 N. CHURCH ST '1e. MONROE
Street Address • City
1f. NORTH CAROLINA ig. 28112
` State Zip Code
1 h. 704-296-4210 '1 i. 704-296-4232 =1 j.
, Telephone i Facsimile •
E-mail
_ _.__..- •-- _ ._-.-- . -- _ __._...___ .__._.___ ..,-_-__-......__...,. _.._
UNION
•
„2_-Projecf (Facility) Information_ - -- _.___._..-__-. . _..___..._.._.
2a. Bonds Grove 2b.
Brief Project Name (permit will refer to this name) • County Where Project is Located
1j3_ Person:
Public Works
_Contact
'3a. Charles..P. OT.Cain, P.E. - Deputy Director of
77
'1 Name and Affiliation of Someone Who Can Answer Questions About
this Application
o'cain@co.union.nc.us
fib. (704) 296-4210 -3c.
Phone Number • E-mail
If Modification, Permit No.: •
1. Project is IJ New ■ Modification (of an existing permit)
''e For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another
phase, changing line size/length, etc.). Only include the modified information in this permit application - do not
_ duplicate project information in B(7) and B(10-11) that has already been included in the original permit.
'2. Owner is [Public (skip to Item B(3)) ❑ Private (go to Item 2(a))
Y.
>'2a. If private, applicant will be:
0 Retaining Ownership (i.e. store, church, single office, etc.) or
❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) :
❑ Selling units (lots, townhomes, etc. - go to Item B(2b))
2b. If sold, facilities owned by a (must choose one)
■ Public Utility (Instruction III)
0 Homeowner Assoc./Developer (instruction IV)
'13. UNION COUNTY PUBLIC WORKS DEPARTMENT -TWELVE MILE CREEK WWTP
'=* Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project
'';4a. TWELVE MILE CREEK .4b. NC0085359
':' Name of WWTF WWTF Permit No.
5a. UNION CO. PUBLIC WORKS 15b. 8"
c. WQ0016274
Nhl
Owner of Downstream Sewer 1 Receiving Sewer Size
Permit Number of Downstream Sewer (if known)
=:6. The origin of this wastewater is (check all that apply):
' 2 Residential Subdivision I ❑ Car Wash
I 100 % Domestic/Commercial
: ■ Apartments/Condominiums i • Institution
■ Mobile Home Park I ❑ Hospital
% Industrial
; %Other (specify):
■ School 0 Church
• Restaurant # 0 Nursing Home
s
} • Office , ❑ Other (specify):
>: 7, Volume of wastewater to be permitted in this project: 30,240 gallons
per day
lkf 8, If the permitted flow is zero, indicate why:
IN Interceptor Line - Flow will be permitted is subsequent permits that connect to this line
? ; 0 Flow has already been allocated in Permit No.
0 Rehabilitation or replacement of existing sewer with no new flow expected
K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS
PAGE 4
Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H
.0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than. '
that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to
the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in
accordance with 15A NCAC 2H .0219(I)(3).
360 GPD PER LOT X B4 LOTS = 30,240 GPI]
(3Bedrooms)(120 GPD)(84 Lots)
10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary)
Size (inches) Length (feet) I Gravity or Force Main
; (use the pull down menu)
8
4,477
ENTER TOTAL LINE LENGTH IN MILES .4;47T p,
11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary)
Location ID =�
(self chosen - as shown on = Design Flow
glans for cross-reference) AMGDI
GRAVITY
Power Reliability Option
Operational Point (1- dual line feed; 2- permanent generator wIATS; 3-
GPM a TDH__L portable generator w/telemetry;_ 4-wet well_storage)
. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force
I ins (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?
MidYes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a
variance is requested:
;SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
13. Have the following permits/certifications been submitted for approval?_+EJ
Wetland/Stream Crossings - General Permit or 401 Certification? Yes ❑ No
Sedimentation and Erosion Control Plan? Yes ❑ No
Stormwater? Lf Yes ❑ No
❑ NIA
❑ NIA
❑ NIA
K APPLICATION for GRAVITY SEWERS PUMP STATIONS, AND FORCE MAINS PAGE 5
Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03
(FAST -TRACK SEWER SYSTEMS)' to collect and record the stream classification data below (attach additional sheets as
necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality
Z regional office (see instructions for addresses) OR indicate the following:
El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope
waterbody; AND,.
0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability
option for any pump station near a Class C down slope waterbody.
z
0
Location ID on Map
(self chosen - as shown on Name of Waterbody Stream Waterbody
map for cross-reference) Waterbody County River Basin Index Classification
SITE TWELVE MILE CREEK UNION CATAWBA 11-138 C
Submit the $.a"" x 11" COLOR topographic map as required in Instruction VI
regardless of whether a classification is provided!
Applicant's Certification:
1, JON C. DYER, attest that this application for Sewer to ServeBonds Grove has been reviewed by me and is accurate
and complete to the best of my knowledge. I understand that if all required parts of this application are not completed
and that if all required supporting documentation and attachments are not included, this application package is subject to.
being returned as incomplete, Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B,
any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of
a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil nettles up to $25,000 per
violation.
(27
Signing Official Signature
Professional Engineer's Certification.
I attest that this application for SEWER TO SERVE Bonds Grove has been reviewed by me and is accurate, complete and
consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of
my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance
with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996,
and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000
and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package
may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I '.
have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC
General Statutes 143-215. 6A and 143-215.6B, any person who knowingly makes any false statement, representation, or
certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as
well as civil penalties up to $25,000 per violation.
2a, STEVEN S. WILSON
Professional Engineer N
2b, DPR ASSOCIATES, INC.
Engineering Firm
2c, 420 HAWTHORNE LANE
Address
2d. CHARLOTTE
City
2e. NC
State
704-332-1204 2h. 704-332-1210 2i, SSWILSON
Telephone Facsimile E-mail
DP
2f. 28204
Zip
SSOCIATES.NET
Dat
Seal, ture & Dat
ik
r
i
—s
•
1.
698E
S'S)
ash 000CZ/j
rmit Number WQ0023044
Program Category
Non -discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer
Extensions
Primary Reviewer
sonja.williams
Permitted Flow
30240
Facility
Facility Name
Bonds Grove
Fast Track
Permit Tracking Slip
Status Project Type
In review New Project
Version Permit Classification
Individual
Permit Contact Affiliation
09/08/03
Location Address
Owner
Major/Minor
Minor
Region
Mooresville
County
Union
Facility Contact Affiliation
Owner Name
Union County
Dates/Events
Owner Type
Government - County
Owner Affiliation
Jon Dyer
400 North Church Street
Monroe
NC 28112
Scheduled
orig Issue App Received Draft Initiated Issuance
09/05/03
Regulated Activities
Subdivision
Outfall NULL
Public Notice Issue Effective
9/gfk3
Requested/Received Events
Additional Information requested
Additional information received
Expiration
Waterbody Name
Stream Index Number Current Class
Subbasin
UNION COUNTY PUBLIC WORKS
400 N. Church Street
Monroe, NC 28112-4804
704/296-4210
Fax 7041296-4232 JE'" `17 "N'o`
D1
��'sdT �l TTA L
A.E:r �iI• fir �I �f �../•
To: NC Department of Environment and Natural Resources
Mooresville Regional Office
919 North Main Street
Mooresville, N.C. 28115
Attention:
SEP 0 5 2003
WATER QUALITY SECTICI late: 9/2103
Regarding: Sanitary Sewer to serve Bonds Grove Subdivision
We are sending you: ❑ Copy of Letter ❑ Plans ❑ Prints ❑ Shop Drawings
® Other
Copies
Date
No.
Description
1
8/27/03
Original Non Discharge Permit Application
1
8/27/03
Copy of Non Discharge Permit Application
1
8/28/03
032016
Check for $400.00 (Application Fee)
These are transmitted as checked below:
® For approval ❑ For your use ❑ As requested ❑ For review and comments
Remarks:
Received by: Date:
ENGINEER'S CERTIFICATION
Re: Bonds Grove P
Sege;
DPR Comm. No: 02964.9
DPR ASSINC.
Landscape Architects
Partners & Engineers
420 Ham hor no Lane
t P. NC 28204
Picr04rr 1204
Fax704/33.2-€2 0
I, Steven S. Wilson, as a duly registered Professional Engineer in the State of North
Carolina, hereby state that to the best of my knowledge, due care and diligence was
used in the construction of the subject project by the contractor, such that the subject
improvements were built within substantial compliance and intent of the approved plans
and specifications.
Signature:
Registration No.: 15497
Date:
/9
Fax Copy:
Bob Moss, w/ 1 Set Asbuifts
Colony Price, LLC
704-364-4100
Charlie G'Cain, w/ 1 Set Asbuifts
Union County Department of Public Works
704-296-4232
REEVED
WATER OUAL.f° SfiCTIORI
AUG
August 4, 2004
r Kim Colson
NCDENR Division of meter Quality
17 bail Service Mentor
Raleigh, NC 27699-1617
Bonds trove Phase 1
Sever Permit # WQ0023044
Union County, NC
G PP Comm: o: 02064.9
Dear Mr. Colson:
DPR A.
LartdscapeArchitects
i rI a rs x3._..._ n . .
200 .;i uhc rri
Phone 784/332-1.2 4
F2x 7041332
Please find enclosed the Engineer's Certification and one set of s-bunts for the subject
project.
Please give me a call if you have questions or need additional inform tion.
Sincerely,
DPR ASSOCIATES,INC:
Steven Filson, P.E.
Fax Copy: Bob Moss, vvl 1Set Asbuilts
Colony Price, LUQ
704-364-4100
Charlie C'in, 1 Set Asbuilts
Union County Department of Pub works
'7'04-296-4232
Michael F, Easiey, C ovemor
Wi111am G. Ross Jr,, Secretary
North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P,E., Director
Division of Water Quality
May 3, 2005
John C Dyer
Director of Public Works
Union County
400 N Church St
Monroe, NC 281 1 1
SUBJECT:
Permit No. WQ0023044
Wastewater Collection System Extension
Final Engineering Certification
Dear Permnittee:
The Division received a final engineering certification for the subject project on . Enclosed is a copy
of the certification page for your records. A full review of the certification materials may or may not
be conducted. It is assumed that receipt of this certification indicates compliance with all
regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for
keeping a copy of the final record drawings for the life of the project. If you have not received
such copy from your consultant, please contact them immediately to obtain a copy.
Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this
permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not
automatically transferable. Form PNOCF-S can be downloaded from
http://h2o.enr.state.nc.us/ndpu/ndpua s.html4Sewer.
If you have any questions concerning this document or the completion of Form PNCICF-S (if
necessary), please contact me at the letterhead address or via E-mail at
marie.doklovic@ncrnaiL.net.
Sincerely, }
K. Marie Doklovic, PE
EnvironmentalEngineer
Enclosure
Cc: Mooresville Regional Office, Surface Water Protection Section iait documents)
DPP Associates (no enclosures)
Surface Water Protection Section Centra Files (certification page only)
One
North Carol na
A740lrally
Pretreatment, Emergency Response and Collection Systems Unit Internet http:)lah2o.enr.nc.state.usJndpu
1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer
Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled110%o post -consumer paper
October 28 2005
Alan VV. Klimek, , P.E.
NCDENR - Division of Water Quality
Mooresville Regional OfficeDPR
919 N. Main Street
Mooresville, N.C. 28115
Re Park Providence Phase
Sewer Permit # VVO0023044 DA
Union County, NC
DPR Comm. No: 02064.9
SOCIATES,r ,
.
cape d is
Planners ane
428lda watt me Lane
Charlotte NC 2 204
Rhone 704 332-P2i 4
Fax 7 4, 337-lei�) ...e._-_ ..
Dear Mr. Klimek,
Please find enclosed the Engineer's Certification and one set of asiiiibuilts for the
subject project. This certification covers manholes 5 through 10 in Phase 2, lots
6 through 21..
Sewer manholes 2 through 5, 11, & 21 through 24 were certified previously by
me on August 4, 2004. Give me a call if you have questions or need additional
information,
Sincerely,
DPR ASSOCIATES, INC.
Copy to, Dennis Reynolds
Colony Builders
4500 Cameron Valley Pay, Suite 120
Charlotte, NC 28211
Cindy McCrory'
First Colony Corporation
4500 Cameron Valley Parkway, Suite 50
Charlotte, NC 28211
Charles OiCain
Union County Public
400 N. Church St.
Monroe, NC 28112
SSW/kb.,
Y.` 2002 Project sti02064\Do . r ents102064 er g
orks Dept.
ewe
C4-2-0.dc
ENGINEER'S CERTIFICATION
Re: Park Providence Phase 2
Manholes 5 through 10
Sewer Permit # WQ0023044 Dal, ea
Union County, NC
DPR Comm. No: 02064.9
DPR AS 0E017E5, INC.
Landscape Architects
Planners & Engineers
�_.420 Hawthorne Lane
Charlotte, NC 28204
Phone 704/332-1204
Fax 704/332-12!0
x Partial n Final
I, Steven S, Wilson, as a duly registered Professional Engineer in the State of North Carolina,
having been authorized to observe (x periodically, ❑ weekly, ❑ full time ) the construction of
the Bonds Grove, Union County project for the Permittee hereby state that, to the best of my
abilities, due care and diligence was used in the observation of the construction such that the
construction was observed to be build within substantial compliance of this permit;
15ANCAC2H.0020; the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as
applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SSW/lib
Y:12002 Prajects1020641Docurnents402064 eng cert lir sewer 10-28-05.tioc
For
V
Fast Track Engineering Gerti ltixion
Permit No. WQ0023044
November 4, 2005
Complete and submit this form to the permit issuing regional office with the following.
One copy of the project record drawings (plan & profile views of sewer Tines) of the wastewater collection
system extension
Supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
Changes to the project should be clearly identified on the record drawings or in written sumrnary form. Permit
modifin h n r, l in rron rn Hance is emit r lath
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer°s Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division..
Vit 1 .143 k
ENGINEER'S CERTIFICATION
`Partial El Final
as a duly registered Professional Engineer in the State of North Carolina, having
been authorized to observe periodically, D weekly, [J full time) the construction of the Bonds Grove project,
Union County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in
the observation of the construction such that the construction was observed to be built within substantial
compliance of this permit; 15A NCAC 2H ,0200: the Division of Water Quality's (Division) Gravity Sewer l s`rtirnun
Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -
Track. Permitting of Purnp Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting
materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WiTH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
sponsibie for tracking all partlai certifications up until a final certifidation is received. Any
wastewater l ow made tributary to the wastewater coilection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement action.