Loading...
HomeMy WebLinkAboutWQ0022768_Regional Office Historical File Pre 2018 (2)OF WATE9 f ! r >: Q :' ze fviichael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality July 01, 2003 Mr. Jon C. Dyer, Public Works Director Union County 400 N. Church Street Monroe, North Carolina 28112 Subject: Permit No. WQ0022768 Union County West Union Elementary WWPS and Force Main Wastewater Collection System Extension Union County Dear Mr. Dyer In accordance with your application received on June 26, 2003, we are forwarding herewith Permit No. WQ0022768, dated July 01, 2003, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system-widecollection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 Internet http:l/h2o.enr.state.nc.us/ Telephone (704) 663-1699 Fax (704) 663-6040 AJ NCDENE DENR Customer Service Center Telephone 1 877-623-6748 Mr. Jon Dyer Page 2 In accordance with the provisions of Article 21 of Chapter 143, Genera! Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County for the construction and operation of approximately 100 linear feet of 8-inch gravity sewer; a102-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, and a portable generator receptacle with telemetry; as well as approximately 10,887 linear feet of 4-inch force main to serve a school of 800 students/staff and 62 residences as part of the West Union Elementary WWPS and Force Main project, and the discharge of 34,500 gallons per day of collected domestic wastewater into Union County's Twelve Mile Creek WWTP (NPDES No. NC0085359) existing sewerage system, pursuant to the application received June 26, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Union County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0085359) David Rector, Eagle Engineering, Inc. Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically 'mentioned herein.' 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed_ A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other govemment agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500_ 11. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b_ Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 1 st day of July, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, 4P:E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0022768 Fast Track Engineering Certification Permit No. WQ0022768 July 01, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the West Union Elementary WWPS and Force Main, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO.MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) WO-0022-76,S 1. Owner: 'la. Union County Full Legal Name (company, municipality, HOA, utility, etc.) z 1 b. John C. Dyer, P.E. 0 , Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) F- ;1c. The legal entity who will own this system is: ' ■ Individual 0 Federal • Municipality ■ State/County 0 Private Partnership 0 Corporation • Other (specify): re O0Id. 400 N. Church Street Ile. Monroe , Street Address City U. If. North Carolina lg. 28112-4804 Z State Zip Code ;1 h. 704-296-4210 11 i. 704-296-4232 'lj _._ Telephone acsimi e E-mail Q O 2. Project (Facility) Information: ' —I Or W2a. West Union Elementary WPS and Force Main 2b. Union a Brief Project Name (permit will refer to this name) County Where Project is Located < 3. Contact Person: Q 3a. David P. Rector, P.E. Design Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-882-4222 3c. drector@eagleonline.net Phone Number E-mail (of an existing permit) If Modification, Permit No.: 1. Project is 11.1 New • Modification For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ►i Public (skip to Item B(3)) • Private (go to Item 2(a)) 2a. If private, applicant will be: ❑ Retaining Ownership (i.e. store, Z ❑ Leasing units (lots, townhomes, 0 ❑ Selling units (lots, townhomes, etc. ' 2b. If sold, facilities owned by a (must choose one) church, single office, etc.) or ■ Public Utility (Instruction III) etc. - skip to Item B(3)) i ■ Homeowner Assoc./Developer (Instruction IV) - go to Item B(2b)) Q 3. Union County 2 Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project De O 4a. Twelve Mile Creek Waste Water Treatment Plant 4b. NC0085359 Li- Name of WWTF WWTF Permit No. Z 5a. Union County 5b. 8-inch 15c. Unknown l— Owner of Downstream Sewer Receiving Sewer Size 1 Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): i - 0 Car Wash Ce 0 Residential Subdivision W ■ Apartments/Condominiums ■ Institution 100 % Domestic/Commercial a ❑ Mobile Home Park • Hospital m ►4 School ❑ Restaurant _ ■ Church % Industrial ; 0 Nursing Home % Other (specify): • Office s • Other (specify): (p fY)� 7. Volume of wastewater to be permitted in this project: 34,500 ADF gallons per day 8. If the permitted flow is zero, indicate ❑ Interceptor Line - Flow will be permitted ❑ Flow has already been allocated ■ Rehabilitation or replacement of why: is subsequent permits that connect to this line in Permit No. existing sewer with no new flow expected DTA n'lrn'1 D.... 1 /1C!A APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2HPAGE .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). goo baS 15 GPD / STUDENT + 360 GPD / DWELLING 3 4,/ ,ADO 12., o00 + 22,,500 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main — __ _ (use the pull down menu) -- - — ---- -- 8" 100 Gravity 4"._...-_.-_.-_—_..10,887 �--_.��........__.....__...._...__..------Force �-............................................... Main 6. LLI—.__....._._._._._...._... -- --- Z— - — - — - 1— Z0 — - - _ - — Z ENTER TOTAL LINE LENGTH IN MILES. 2.1 Q11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option Ce (self chosen - as shown on . Design Flow . Operational Point (1- dual Tine feed; 2- permanent generator w/ATS; 3- 0 plans for cross-reference) (MGD)- GPM @ TDH `portable generator w/telemetry; 4-wet well storage) 1 i _WWPS 0.0863 102 @ 89.6 3-Portable Generator w/ telemetry ce W 1 - C" 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force m Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ■ No : If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: - • 'SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 113. Have the following permits/certifications been submitted for approval? , Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ■ No ►�4 N/A Sedimentation and Erosion Control Plan? Yes 0 No ❑ N/A Stormwater? ■ Yes ❑ No ® N/A V-rA A']/AI n.... 1 1141111, APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Z 0 Q O_ lL N Crj Q . 0 2 WC ix F- N V 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: • A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, ..,oes.--... __..we � -�--�-W -does . ApStream Classification is not needed because the design depend...__- _.. not on wet well storage as a power reliability option for anypumpstation near a Class C down sloe waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) _Waterbody_ County River Basin Index Classification A Blythe Creek Union Catawba 11-138-2-6-1 "C" B McNeely Branch Union Catawba 11-138-2-6 "C" UNT McNeely Branch Union Catawba 11-138-2-6 "C" Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Z — Q U LL [t La . 0 Q 1. Applicant's Certification: 1, John C. Dyer, P.E., attest that this application for West Union Elementary WWPS and Force Main has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes an else statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor wh h may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 1 a. A. L. e GP 3 Signing Official SignatureIF Date 2. Professional Engineer's Certification: 1 attest that this application for Westilnion Elementary WWPS and Force Main has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest That to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track pefrnittiag of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Divisioeduidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. n,+n,,,fty otiqmn 2a. David P. Rector, P.E. a ° 4.Professional Engineer Name �,,,.�oFESSlpy.��9 ¢ ' a 9r '; .2b. Eagle Engineering, Inc. - 1 Engineering Firm - s. S� 2c. 310 Indian Trail -Fairview Road - 3 Address ' Glp10--••�,.,tj 2d. Indian Troll 2e. NC `2f. 28079 �'',,,9P,q L?-,',a►'`'' City State Zip erles 1 2g. 704-882-4222 2h. 704-882-4232 2i. drector@eagleonline.net Telephone Facsimile E-mail Seal, Signature & Date I TA n"1/n4 n,,.. 1 ncrn' it Number WQ0022768 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 34500 Facility Fast Track Facility Name West Union Elementary WWPS and Force Main Location Address Owner 07/01/03 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation FO2Mtr 155ug-rD ��r /03 Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affiliation Jon Dyer 400 North Church Street Monroe NC 28112 Scheduled Orig issue App Received Draft Initiated Issuance 06/26/03 Regulated Activities School Subdivision Outfall NULL Public Notice Issue Effective Requested/Received Events Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N CHURCH STREET MONROE NC 28112-4804 704/296-4210 FAX 704/296-4232 TO 114L CNG INS INe JUN 2 62003, NC DEFT OF ENVIRONMENT AND NA1URALRESOURCES NOCRESVILLE REGIOAIALOFFICE TRANSMITTAL ATTENTION I\ EGTvl2 DATE 41 z 9/0 3 REGARDING WS ; /-i U) j S4 at- p S 4 FM We are sending you: Copy of letter Plans Prints Shop Drawings Other Copies Date No. Description / D W Q f �S► — 4 pp Li e - no 4k .2 7 3 03 (4 Lic.70, These are transmitted as checked below: For approval For review and comments Remarks 171-1345E For your use As requested I�T��✓+�2�r) "its A1cD N12. Signed: Received By: Date: • . 74'71. 2 • . ” 4:14ir • :, " .ar • • I "fr't • ; -r . . • • • • . • • • 4 "t . '' •, .....• ,, ;!•• ,. -,..,, • 1.1.1-,,,,..„ -•••- er----, .-, .-.. ,. I... , .,.. .. . _ _.,... t *..-,....,.....-.7.-:- _,....,,, .1 ' .....'" ':::0•- 1.; - •:-., -:•;': '• . T..% •'.f.j .....,..",.'"? ';4.... ..,a, ?. .'• : •,,, - • .... -. ." 4..j' -,,, e•--.7.;',...741,:,/,'77- ,••••;''',-,;%-r.%T.F7.7.N.:',.... -'7' -',. ll?, ".7-14!"r_.-"7,,,":.•-r•-7. ' " ' 4.- ..; . . " -.,. . - ,,.._ •-•"-.1-,...;•,..:-'"' ..- ,'..11,', ,:--Z'F..1::..:•,..:--. :-;.:"-‘,-- 4 . - - • 'r-ZZ. ;'-.. 4-- ••••- . .. '../...".^.,-`..t". . ''.^^7-47 - • -• L • -- ,:;,,,,,!%,,,..flk7.....;n.- *.•!-.-::•Iir-S"-:.''-: ••- •-'' 7----. ' ' ' • . .,-' - -:. .11 :','''', ::',. ..:-:'': 'it e;--';H:'..: ''':;:r1'-''. - • , . • . • • ,,t,- , ,, 4; '1:r•_:•-••,, - • 4:-.1..„,-,,-.4,,'..:,......„....,.,,,,,,.,...!--?,,:.?......,...,,,,r..,.,!:: ..,e....r,.... 4-1. .•:..0:„.2",i.: ,;,• . , , . - . . • • • • . _ - - • • • • , . • - - • ' . ;" • • ▪ ' „ • • •-••!-;,,,,N"-• -7; ' • 4.,;-""'.=;-'4.-:•!"-- • .' .., _ ,. .... .. ,..•.-,•.... ::-,-," : .----• .4 ' & _ _„ - _ --• •••44-",'".....,"-;',•147/6f.•-=4 ;' • •446.,. P.: ' A 'i,-1.-,t-•- I. ' ' -''' • " i ▪ ''' •- ..- ' ' 4- It -•••• •!" • . • „..", ----,-;`,"1% • — • ",•.! , ; : • - • • • 7 7 .2r3;1 wws. P • • • I • • • • . ' • • • • • • • • % • • ; . ; • " • . , -„ • •••"--C.- •7,,.;;;41 - 6 • . • ..'• -- •!, `• ' • -, • •, •, ,. .z :. " .. _ i `. k .t ; ; : -" , r ,,F „y , -. .? - •i- ';r. • ,. ;, . - i . •. .... / ,. . . . 4 . ' • • ," -, . , 7 . t : .- 4 . 4 •; - •, : • , - . . . . : '-- ', - - " 7 11 • , ; :-, 2 I- . , ., -7! _ !. , - - , "! : ' ' . 7:; _ ' ' 7 - ' ' ' ' ' ' ' ' • - • 1?"1:., 7 : , - - : • .4 - •- -- , . - - 7 , 4 - 4 - - 7 - . , , , , ,, - ; L : : : : , : - . , . . . . „ . : _ s . 1 4 - - - "L • . . •:. .. . . . : - . . -.7_,c4_.._,,.„ — . ,„A - •-• ,;7.a- "•2,. -',4 '„,;,' .' ':'11 :,_,j.',.". ,•• -,:.- '-., , '''..', -,- ,' •.x-. ', ',„•1'f ..,e .•. N',,.-i:.: '.:....:"","1::. ,%:";',e .,- .'i ;Ag '.-..• "re‘ - . ;- -,, ,4-'. •.-;- :,7.e) .;..- 'if: .4.i ... .: ".;' .., .,;. ;. ..y ,;. :,. .., .t,:.=. '.e7.,',. !. . . '.2 . '...7,-: '..", , •, -....0` -.!`t< ... f,.•-1...1•i'• 4 ‘,- ,•,-•,1'••. .'1:.,,t.'.1,.1'-',i1: -,i.,.,.-.,..‘: •1..,i '1,•,•6e.•. . ,. `.`4:•. ,!. ..•*„''.4•" ,,'',' :..4 ' 4 „ - 5 - ', ' '; '4, ' - I ' " „ , .' F-" , _ " .•: '_ :, .,. F . , n '. ,'t - . •„ .;-..:„L'"'i .—.,.•..-•••-i-.. .•,-..';•7,':',3":-,•-'-,,•.'..,.f:kL.:'..,.. --)"- r.:"-, ;z,-'..,-,..',", .--.,., '-, „-y -'_1.-,:. . :.!.,..„- ..."; "', -.-C..- ..'. ,' .'.'., '.,'7.,': C..'.T, •.g r▪ 7r";'.''4.,...:.;,.,4.',.'-,',i•,.- ',---,'L'..1,',''••'T,"'..i.4:;,'',',,.-4:,:.V."r:.',-'y;'-'''1,,.'-:. -'7s'‘'.-,7....•.2-1'._,t,- '... ..--.,.. F., ."4-,4-.4.,. :.1. 44. 1''% • '•„ . , -'-!.- '.-,,: ?f'i ..., ::.,.., -.",,.f l-. 4-.7• -- -,,•.:';. ":,', -'-='-1,.- `7';'4 '. ,„,;''.,' l.1. ..7,,4..,,r-.,, _-,,:.!'.?,-'.,.!;•,.["'.:.2.4 ,-, ;••..,'••-'..-..-::,'i. ::., -,7L' ,I .,-' . 1 . ..2--c--.r--' , - `-.' .,,. . ,'"', ' '5;- .. ..1- ,. -&,4.. . .s. •..'', .4,;-,7:-., Z-1•-,;" '•;", J-',_j.,-?7: :. *- C:'-2•fr,'•1'qrt,:-„'-.':.'t,',7.,.:%,!., ''; , ,: 1 ,; :,n •.0 ; . ,-.,4•;:yt :';'_-'.'& ': .. '... F ,. .e' ..' ..' ,.'•.- -'.--.,' .:_-.1'•.': '; 4 ,•,'_.,% . ,7",..' ,•.,4-6'.'.'-'.1::.1..'' ,4-: • 1 • . - - : :_ '• -T .. -Li ..t . -1: ...., ..4-,..,.," •..,7'.;T•" ,-.- ,7-`.71 ..-1.i,:2"•'' 3;- [',,r'•4'. e . ''-:. ,7'.;- ',; 4.,. . " .:•:. . ' ..- . T..,„ - -. ,. .., 7 . . . - ...?, '4 : ' .• ,- . . '• .t- '3 : ,•,1., '- -;,-.. 1 t• •--,:,.„":'•....',•1:...•i,,.4:1.; '.•, '.'. .•' .'-,•. :•- :f- -- ",r:4•4„ ;1f.'.':, '''• '- r' • •_-1-• ,.TrVi!:f'.."..:",,,...1.- c :ri.- •-' , ,,-. . . .-..4''• ' ; '•:,'''• -' '.. .:.. . --'f.t.: Ir y ', -,, ., .,:-. •/ .4,r"q [41,". ,:..:, 7'I‘7,.0, 'r a`.4," .4. .t.•, ...,„' ',,'',4., '14 . .'-•-•,74-, ,...,-" 1.-.-i.4..•• •'- .:..4 ,. •.'-:,,= .\ -• . „. . - ' _7&4 ,;;- , -• ,, '. - . ' r ' r % . '.. . vyf*:-•-7.--:;_.!,,,-,-.4, -t ,' t '7777 - 4..e, r,,Y ,'1'• --,-'1‹-..7_„--.. `:- 7.:'2. ... ....• :•..• ,.,. • : • ; • , - " • .- . . ; . 4 ; -•• . • - . - • •"."4,• - .• • 1 ••• : "?-4•"4`•01": ▪ •-.: ••"4 17. • • • • •.. 7 7r - • " . ' 4" ' • • • , „ • • • • ' - • • • • " L ' • .4-.,n4„:,-„.44s,:r ..r r • ..\ •— ' = - . ,•-:. :_ F . PORTION OF WEST UNION USGS 7.5 MINUTE ELEMENTARY SCHOOL ' . WAXI-LAW. N.C. QUAD WWPS AND FORCEMAIN ', . -.,10 Indian irai I - Ear-. t...v Rd. Si Mali. \ c = •,-.-o , 704)s42-•:::: 4.'"eit 1 V.7-.21.44C111•7: .,. i 4 or ) i©iiee" au►.mvii !"'I a io eseiei noiAl (i917 P"liq} Ef ■ .iJmoiirlifwlon L pa;sri 'i i ia►aaidouoica►idVi aaiaup a�«tiL9tt. ft6+It9 611UU 4 1k t OIll R He •pinIgs7 "2119-Hrd fijal`k WI r r SJ K 5 a�r�/i!!``TTr��;��►,�(�y.tt 1 s ss uu L IK:1 U:_1 l IGMA t�74.1 tt i% 411116N VOLL%7U :IJ ERFORMANCE PUMP'P. Total Head In 1. Ft 4) 140 12 35 30 25 20 60 5 40 Ga Dia. 10 20 30 G7 7 SUBMERSIBLE GRINDER PUMPS MODEL: WG30HNVG50HANG75H WGX3OH/WGX5OHANGX75H SPEED: 3450 RPM 70 80 50 100 110 76) (227) (285 7 (416) AvaUab Standard WG30H-21-2 WG30H-03- G301-1-232 G30H-43-25 G3OH-53-25 WG50H-21 -25 G50H-03-25 G50H-23-2 G50H-43-25 G75H-43- VVG75H-53-2 odes Explosion G GX30H-03-25 WGX3OH-23-2 GX30H-43-2 GX30H-53-?5 VVGX50H-21 -25 WGX50H-03-25 GX50H-23-25 GX50H-43-25 GX50H-53-25 GX75H-03-25 GX75H-23-25 GX75H-43-25 GX75H-53-25 Proof HP 1 Volt X3OH 21 25L31 230 3 0 ;3C10 • 46 575 230 200 3 230_ 3 Start Run PhaseHertz Ams Am 0 2 21 3 6 9 460 3 5 575 3 7.5 200 7.5 230 7.5 1 460 3 7,5 575 Electrical Data Run KW Start KVA .0 4,3 . 4.3 4 3 26 4,3 41.9 23.9 21,1 20,7 NEC Run Code KVA Letter 4.8 G 5 2 H 60 21 , 5.2 4.3 21,0 5.2 60 122 32 6.3 28, 7,4 6021.6 6.3 3 7. 78 18.8 6.3 27,0 6 39 9.4 6.3 1, 7. 6031 7.5 6.3 0 7, 60 90 25.8A 7,9 60 78 227, 27.0 60 11,2 7,9 8.9 ' 60 31 9,0 7,9 31.0 Service Factor .4 A 1 7 • , 1,7 1.7 1,7 1,7 5 • 5200/296 WG30 & WG3OH WG50 & WG5QH WG75H (grinder Pumps 13800A876 HIGH CAPACITY GRINDER PUMP WG INSTALLATION AND SERVICING INSTRUCTIONS FOR MYERS WG75H,WG50, WG5OH, WG30 AND WG3OH GRINDER PUMPS 3, 5 AND 71/2 HORSEPOWER 3450 RPM HIGH HEAD GRINDER PUMP WGH 5200/297 " PUMP MODELS --The 3, 5, and 71/2 HP grinder pumps ,are made in two models. The WG50 and WG30-5 arid 3 HP unify are for high capacities at medium head conditions. Wye ve sheets Page 3c 4.) The VVGi5H, WG5OH, and WG30H-71/2, 5, and 3 HP units are for lower capacities at higher Beads, (See curve sheet Page 304.) Both series are made for single phase 230 volts and three phase for 200, 230, 460 and 575 volts. (See Fig, 1 and Fig. 2 for pump construction.) PACKAGING —Each pump with 25 ft. of power and control cable is packed in card- board carton with Wooden support base. Catalog number and engineering number are labeled on the carton. INSTRUCTIONS —These instructions cover only the pump unit. Other instructions for lift out rail system and electrical controls are included with those items. Cornplete dis- assembly instructions are furnished only to authorized service stations. ) Control Cord #18/5 Potted -in Lead Wire All Fasteners Stainless Stee Ball Bearings.Top and Bottom 011 Lubricated Motor Housing Cast Iron All Iron Parts Coated Inside and Out with Baked -on Epoxy Paint Seal Chamber Oil Filled Support Sleeve Bearing Prevents Shaft Deflection Due to Radial Load from Grinder Impeller Pump Impeller Bronze Shredding Ring Hardened -Stainless Steel Shaft Locking Screw Power Cord STO Or S0 insulation # 10/4 _ Rubber cord Seal and Grip Connection Compartment Stator Winding. Suhin"erged InOil Stainless Steel Pump and Motor Shaft Mechanical Shaft Seals Carbon and Ceramic Faces Electrode'to Sense Seal Failure . 'Pump Case .Cast'Froh Grinder Ifnpelier Hardened Stainless Steel CAUTION —PUMP IS NOT TO BE DISASSEMBLED IN THE FIELD EXCEPT AT CERTIFIED SERVICE STATIONS OR AT MYERS FACTORY. WARRANTY IS VOID IF PUMP 1S TAKEN APART FOR ANY REASON EXCEPT TO REPLACE GRINDER IMPELLER AND GRINDER RING WHICH IS COVERED IN THESE INSTRUCTIONS. DESCRIPTION OF PUMP— Fig. 1 and Fig. 2 are cut -away drawings of pump showing both high capacity and high head types. Ali motor components except shaft are the same on both series. These pumps are designed for the rugged service of grinding and pumping commercial and industrial sewage. They are not intended for pumping heavy slurries or liquids containing abrasives or corrosive elements. Three phase motors are generally used for commercial and industrial service but single phase motors are available where 3 phase Control Cord #18/5 Potted In Lead Wires All Fasteners Stainless Steel Ball Bearings Oil Lubricated Motor Housing Can iron Air Iron Parts Coated Inside and Out with Baked -on Epoxy Paint Seal Chamber Oil Filled Support Bearing Prevents Deflection troln Side.Load of Grindor°Impeller Pump Impeller Bronze Shaft.Lbcking Screw Power Cord STO or SO Insulation . #1014 Rubber Cord Seal and Grip Connection Compartment Stator Winding Submerged in 011 Stainless Steel Pump and Motor Shaft Mechanical Shaft Seals Carbon and Ceramic Faces Electrode to Sense Seal Failure Pump Case • Cast iron Shredding Ring Hardened Stainless Steel Grinder impeller Hardened Stainless Steal FIG. 1 FIG. 2 13S00A876 5200/298 cannot be obtained especially in rural areas. Transformers must be large enough to maintain full voltage for single phase. Low voltage on large single phase motors can. cause considerable trouble and motors are not guaranteed to operate on low voltage. All single phase motors must have special electrical control box furnished by Myers. INSTALLING SINGLE PHASE MOTORS WITH CONTROLS OTHER THAN MYERS VOIDS WARRANTY. Pump motor chamber and seal chamber are oil filled for long life and best heat transfer. The seal chamber is provided with an electrode to give signal to control panel if water enters the seal chamber due to worn or faulty lower seal. Motor is provided with a heat sensor that automatically stops motor if overheating occurs for any reason. This sensor resets as soon as motor temperature drops to safe Guide Support Bracket • Slide Rails Gale. Pipe Pump Support Pipe Gale. Check Valve and Sealing Casting Discharge Pipe Gate. or Plastic All Iron Paris Coated Inside and Out with Baked -on Epoxy Paint range. Heat sensor trips at 200°F. Additional overload heaters are used in the control box to trip under overload conditions. MOTOR CORDS— Each pump motor has two cords, one large power cord and one small control cord. Both cords are the same for single and three . phase. The power cord is a 4 conductor type with ST or SO 600 volt insulation. The wires are color coded blue, black, red and green. For 3 phase the blue, black and red lines are power lines and the green is ground. For single phase the black and blue lines are power and the red is for start winding and the green is ground. All cords are CSA and ULapproved. Any three phase motor can be reversed by interchanging any two line leads. Single phase motor is single rotation only. Correct motor rotation is counterclockwise when looking at the grinder end of pump. • Lifting Chain Support Conduit Fitting Gale. Grinder Pump Unit Pump Seal and Discharge Casting FIG. 3 13800A876 5200/299 The control cord is a 5 conductor type with ST or SO 600 volt insulation. The black and white leads connect to heat sensor and the red conductors connect to seal failure, green is ground. All green ground wires connect to screw terminal in motor connection housing and to grounding bar in electrical control box. IMPORTANT - These ground wires must be connected in control box to grounding bar that is connected to a good outside ground. MO- TOR IS NOT SAFE UNLESS GROUNDED. INSTALLING PUMP IN SUMP - These pumps re usually installed in concrete or fiberglass basins with the lift -out rail system. Fig. 3 shows pump mounted on the rail system. Instructions for installing rail system is fur- nished with rail package, If pump is not installed with lift -out rail system it must be properly supported to discharge pipe so that space is provided under pump for entrance of sewage. Pump inlet should not be closer than 5 inches from bottom of sump. it is not generally desirable to install these pumps without the rail system except on special O.E.M, packaged systems. MODEL WG30-21 WG30-03 WG30-23 WG30-43 WG30-53 WG50-21 WG50-03 WG50-23 WG50-43 WG50-53 WG30H-21 W G 30H-03 WG30H-23 WG30H-43 WG30H-5 WG50H-21 WG5OH-03 WG50H-23 WG50H-43 WGSOH-53 WG75H-03 WG75H-23 WG75H-43 WG75H-53 MAXIMUM AMP STARTING PUMP AFTER INSTALLING IN SUMP BASIN - If pump is 3 phase pump rotation must be checked. Before lowering pump into basin connect power lines and start motor using H-O-A switch in the hand position. Grinder impeller should turn coun- terclockwise when looking at grinder impeller. If rotation is wrong interchange any two line leads at control box. CAUTION - keep hands completely away from grinder impeller when making this check. Disconnect line leads from panel and mark wires so they can be reconnected in same manner as used for test. THREE PHASE CONTROL BOX - Any suitable three phase control equipment can be used for simplex or duplex operation. These control boxes are also available from Myers. If other than Myers box is used over- load heaters must be selected in accordance with full load amp ratings given in this instruc- tion booklet. SINGLE PHASE CONTROL BOX - Single phase pumps must use the Myers control box. Warranty is void if other than Myers single phase control box is used. IND NG RESISTANCE VALUES WINDING RESISTANCE IN OHMS BLACK BLACK RED TO MAX. SPEED VOLTS PHASE TO WHITE TO RED WHITE AMPS 3450 230 1 .47 3.14 3.61 36 3450 200 3 .72 .72 .72 20.5 3450 230 3 .72 .72 .72 17.8 3450 460 3 2.9 2.9 2.9 8.9 3450 575 3 6.5 6.5 6.5 7 3450 230 3450 200 3 3450 230 3 3450 460 3 3450 575 3 3450 230 1 3450 200 3 3450 230 3 3450 460 3 3450 575 3 .47 .72 .72 2,9 6.5 .76 1.48 .98 3.9 1.4 3.14 .72 .72 2.9 6.5 5.15 1.48 .98 3.9 1.4 3.61 ,72 .72 2.9 6.5 5.91 1.48 .98 3,9 11.4 43 28.5 24.8 12.4 9.9 21 1' 5 13 6.5 5.2 5 3450 230 1 .47 3.14 3.61 32 5 3450 200 3 .72 .72 .72 21.6 5 3450 230 3 .72 .72 .72 18.8 5 3450 460 3 2,9 2.9 2.9 9.4 5 3450 575 3 6.5 6.5 6.5 7.5 7' 3450 200 3 .72 .72 .72 25.8 71/2 3450 230 3 ,72 .72 .72 22.4 71/2 3450 460 3 2.9 2,9 2,9 11.2 71/4 3450 575 3 6.5 6.5 6.5 9 If amp readings are hig d i1 'indicates voltage may tie higher or lower than normal or that pump grinder may clogged with trash causing extra loa 13800A876 j 5200/300 CHECK LIST IF PUMP DOES NOT OPERATE PROPERLY CHECKING FOR MOISTURE IN MOTOR— Use ohmmeter and set on highest scale. Readings on the large power cord between any of the conductors red, black, white to green con- ductor or motor shell should be more than 500,000 ohms. Motor probably will run with a lower reading, but if pump is out of service and reading is below 500,000 ohms the motor housing and stator should be removed and baked in a drying oven at 220°F. To be serviced only at authorized service station. Readings should be taken with line Leads disconnected from terminal strip. RESISTANCE OF WINDINGS —Every motor winding has a fixed resistance and winding must check close to the values given below to operate properly. This winding resistance also shows if motor is connected for voltage being used. Use ohmmeter for this test and set on scale to read directly in ohms. TROUBLE CHECK LIST —Troubles listed are generally caused by the pump. Other trouble can occur from faulty control box operation. CONDITION Pump runs but does not pump liquid from basin. These will be listed with the control box instructions. PROBABLE CAUSE 1. Pump impeller may be air locked, this occasionally occurs on a new installation. Start and stop pump several times to purge air. 2. Run additional water into basin so that pump will be submerged deeper to clear air. 3. If pump is three phase, rotation may be wrong. See instructions for checking proper rotation. 4. If air does not clear it may be necessary to lift pump out of sealing elbow and start motor to allow pump to pump for a few seconds. Airvent hole is provided in pump case, so some water will flow from this hole when pump is operating. If vent hole gets clogged clean out. 5. If pump has been installed for some time and does not pump, it may be clogged at grinder inlet 6. Discharge gate valve may be closed. 7. Discharge check valve may be clogged or have a broken clapper. 8. Discharge head may be too high. Check elevation. Maximum pump head at zero flow is shown on pump curve sheet. 9. If above checks do not locate trouble, motor rotor may be loose on shaft which allows motor to run but will not turn impeller or only at low RPM. 13800A876 5200/301 TROUBLE CHECK LIST (Con't) CONDITION PROBABLE CAUSE Red Tight comes on at control box. This indicates some water has leaked past the lower seal and has entered the seal chamber . and made contact with the electrode probe. Pump must be removed from basin within approximately two (2) weeks for replacement of lower seal. This preventative repair will save an expensive motor. Overload trips at control box and alarm buzzer or flashing red light comes on due to high water level in basin. 1. Push in on red reset button to reset overload_ If overload trips again after short run, pump has some damage and must be removed from basin for checking. 2. Trouble may be from clogged grinder causing motor to overload or could be from failed motor. 3. Trouble may be from faulty component in control box. Always check control box before removing pump. Yellow run light stays on continuously. 1. Indicates H-O-A switch may be in the hand position. 2. Level control switch may have failed causing pump to continue to operate when water is below lower weight, or lower weight may have dropped off. 3. Grinder assembly may be partially clogged causing pump to operate at very reduced capacity. 4. Gate valve or check valve may be clogged causing low pump flow. .5. Pump may be air logged. 13800A878 5200/302 CONDITION Circuit breaker trips. TROUBLE CHECK LIST (Con't) PROBABLE CAUSE 1. Reset breaker by pushing clear down on handle then back to on position. If breaker trips again in few seconds it indicates excessive load probably caused by a short in the motor or control box. Check out instructions given with control box before pulling pump. 2. If this condition happens after an electrical storm, motor or control box maybe damaged by lightning. 3. Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box. Pump is noisy and pump rate is low. 1. Grinder assembly may be partially clogged with some foreign objects causing noise and overload on the motor. 2. Grinder impeller may be rubbing on grinder ring due to bent shaft or misalignment. Grease and solids have accumulated around • pump and will not pump out of basin. 1. Lower weight of level switch may be set too high. Set bottom of lower weight even with bottom of inlet flange to grinder. 2. Run pump on hand operation for several minutes with small amount of water running into basin to clean out solids and grease. This allows pump to break suction and surge which will break up the solids. if level switch lower weight is set properly this condition generally will not occur. 3. Trash may have accumulated around lower weight causing pump to turn off too soon. Clean trash from weight and suspension cable. 13800A876 5200/303 REPLACING GRINDER IMPELLER AND GRINDER SHREDDING RING • This is the only disassembly operation allowed in the field. AD other repair, must be done at factory or at authorized service station. STANDARD TOOLS REQUIRED: 1. Allen head socket set. 2. Standard socket wrench set. 3. Set of open end wrenches. 4. Plastic hammer. 5. Vise Grip pliers. 6. Large screwdriver 5/8" wide blade. Heavy handle. 7. Wire brush. 8. Three cornered file. 9. Several smaller screwdrivers. IMPORTANT —Pump should be thoroughly cleaned of trash and deposits before starting disassembly operations. CAUTION —DISCONNECT ALL POWER AN D CONTROL WIRES TO MOTOR AT CONTROL PANEL BEFORE STARTING DISASSEMBLY • OPERATIONS. NEVER RELY ON OPENING CIRCUIT BREAKER ONLY. DISASSEMBLY OF SHREDDING RING AND IMPELLER 1. Remove screws from holding ring and remove ring. 2. Use two screwdrivers, one each on opposite side of ring and pry on snap ring that holds shredding ring in place. Remove shredding ring. 3. Hold impeller by prying against impeller cutting bar and remove cap screw from end of shaft. 4. Use large screwdriver in slot in end of shaft and bump on cutter vane with plastic hammer. Bump in counterclockwise direction as thread is right hand. It may take several bumps to loosen impeller. 1 1 1 If impeller cannot be loosened it will be necessary to take unit to service station for service. DON'T CONTINUE TO POUND ON IMPELLER AS IMPELLER AND SHAFT - CAN BE DAMAGED. 5. If impeller comes off easily clean upend replace if worn. 6. Be sure pump impeller has not loosened when grinder impeller is removed. This can be checked on reassembly of grinder impeller and shredding ring. Tips of. impeller cutter vanes should extend about 1/8" below bottom of shredding ring. If more than 1/8" extends below ring it means pump impeller has loosened. See sectional drawing Fig. 1 or Fig. 2. Remove grinder impeller and ring as described above and remove bolts from pump case and remove case. Use back off screws in motor mounting plate to pry loose from pump case. 7. After case is removed wrap emery paper around shaft and hold with vise grip pliers. Use cloth on impeller and screw up against shoulder. Now pump can be re -assembled. 8. Clean all threads with wire brush and file smooth any threads that may be nicked. 9. Use Never-Seeze or other graphite compound on threads before replacing grinder impeller. Q. Be sure cap screw in bottom of shaft is tight. Hold impeller with screwdriver between cutter bar and teeth of shredding ring while tightening cap screw. 1. Be sure impeller turns free by hand after reassembly. Some drag will occur due to seals but there should be no binding or tight spots when turning -the grinder impeller. 2. ALWAYS use a rag on the impellers when turning to prevent cutting hands on the sharp corners of shredding ring. 13800A876 TOTAL HEAD IN Meters F 30 2 20 TOTAL HEAD tN Meters F 5 40 0 20 10 500 PEA' Is%V Nt,1TE pump performance curves SUBMERSIBLE GRINDER PUMP MODEL: WG30/WG50 SPEED: 3450 RPM DATE: DECEMBER 8, 1987 111111111111 "Note: Single phase 5 HP pumps. do not exceed 5' dia, impeller. IMO EMI Us c 700 Liters SUBMERSIBLE GRINDER PUMP MODEL: WG30H1WG50H/WG75H RING: 20 SLANTED HOLES SPEED: 3450 RPM DATE: OCTOBER 1, 1990 0 10 20 30 -, 40 5© 60 70 80 90 100 11C1 L1.5. Gabor* 0 100 150 200 250 300 350 400 Liters 5200/304 FLOW PER MINUTE 13800A876 WIRING DIAGRAMS oJThoL O.RJ2 tioit.N6 ..- REsaa S 1;!LibEt .•• '644-11ECliAS SCREW SENSOR E't'ECTRODES ON 'STATOR POWER CORD cobillertn 230_ Vf)LI 4.HREE .PHASt. CONTROL CORD Pa:ITINS RESIN S:I=i1:10ES .6CX61-ECT1R'S .GROUND SCREW .MOTOR . . . . HEAT --SEN ER 'ELECTRODES STATOR ON -'STATOR . POWER CORD • 2-*) V`ti5 EJPiig.§..-E . . ......... . CONTPDL Lgaa POtti NG i3EstN 8pucEs tONNcloRs tart )o hill : gi • • HeATsttl$CIR ELECTRODES ON STATOR POWER PIM cONNFCTORS STATOR 460 VOLT -THREE PHASE CONTROL CQRD POTTING RESIN SPLICES CONNECTORS 'G-RDUND• SCR -QV MOTOR ..EIE-A'r SENSOR EUECTROUES 'STATOR •ON:S%)R POWER CORD .200 OR -575 VOLT -THREE PHASE DIMENSIONAL DIAGRAMS •Wdb-dr,lit.R:16tgAp .OR ejb'd)1174DtA=00rikp 16 \-2'1 01A -2 FLAff•dE:ORILL'ED'r6R 2 VZ TDP1PEFLNGE EIL.•....adTwS101.11•1 ANGT'SH'GRINDER:PLIMP WGSOFI GRINDER PUMP OR WG3DRGRINDER•POMP 91. 4 I DiA FLANDE.DRILLED FOR 2 V2 STD. PIPE' FLANGE 5200/410 WG3OH9 WG5OH & WG75H Submersible Grinder Pumps Parts List COVERS 3&5HP_1AND 3PHASE &71I2HP-3PHASE WG3OH, WG5OH & WG75H Submersible Grinder Pumps Parts List COVERS 3 & 5 HP - 1 AND 3 PHASE & 71/2 hp - 3 PHASE No. Description No. Req. Part Number Cord Cap Complete - 3 HP, 10 and All 30 25` Cord Length As Specified Cord Cap Complete - 5 Hf 10 25' Cord Length As Specified Connector 225698010 22569B900 225696011 22569/3901 15781A007 4 5 7 Pipe Plug, 14' NPT, Hex Hd. 'O' Ring, 47/e x 4Sfe' x'/e' Cap Screw, Hex Hd.,'/,s'-14 x 1'/' Cap, Upper Bearing '0" Ring, 51/2' x 5,4° x 5022A54 5676A123 19102A6 225908 5876A112 achine Screw, #10-24 x'', ckwasher,#10 ube, Plastic, 1 l4" Lg, OR Tube, Plastic, 3' Lg. Housing, Motor g,. 5434A43 6107A15 10649A102 10649A116 22571 D Oil, Transformer (5 Gal. C Cap Screw, Socket Hd., 9/e-16 x 1' Lubricant, 'Never Sea Cat. No. NSBT-8, 8 Oz. Can Gad, 4 11009A6K 6106A28 22386A 7 Gasket, Vellumgdd Case, Volute Machine Screw, Socket Flat Hd., 4/,4'19x134' Sealant, Loctite Grade 271 5231A78 226390 7597A21 14550A1 20 22 Retainer, Impeller Machine Screw, Socket Flat Hd., S/10-18 x 1" Washer, Anger Spring Bearing, Bald 22585A 7597A17 19331A6 8565A22 24 25 26 27 0 Rotor with Shaft Shaft Only (ForAll 3, 5, 71 HP Units} Stator Bearing, Ball Housing, Seat Seat, 114" Shaft Ring, Retaining '0°Ring, 7" x 634' x'le" Electrode, Wire Female, Rubber See Chart 22637C100 See Chart 8565A23 22576D 22577A 12558A8 5876A114 22578A A 2 4 5 Plug, Special Housing, Lower Seal, with Bearing '0' Ring, 6' x 5344' x Va Cap Screw, Hex Hd., r/,6 -14 x 1 a/' impeller, Pump, 3 HP (Specify O.D.) OR Impeller, Pump, 5-71/2 HP (Specify 0.D.) 4 A C 5876A113 19102420 225836502 00501 7 41 42 Impeller, Grinder Ring, Shredding Clamp, Shredding Ring Cap Screw, Hex Hd.,'/e°-16 x 1' Washer, 'he x "ha x'/.r Thick 4 260106000 '25134B000 22643E 19101A/0 30A126 43 45 Cap Screw, Hex Hd., Washer, Support Ring, Retaining 4 x 214' 4 'Effective alter Sept. 1, 1990. New impeller and ring are inlerc previous impeller and ring. 05030A215 12558A025 geable with Pump Cat, No. WG30H-21 WG30H-03 WG30H-23 WG30H-43 WG30H-53 W G50H-21 WG50H-03 W G50H-23 W GSOH-43 WG50H-53 22636C101 22636C100 22536C100 22636C100 22636C100 22636C103 22536C102 22636C102 22636C102 22636C102 Stator Only 22574C110 22574C 111 22574C112 22574C112 22574C114 22574C100 22574C101 22574C102 22574C102 22574C104 Stator w/Housing 22571D245K 22571D250K 22571D255K 22571D255K 22571D265K 225710220K 22571D225K 22571D231K 22571D231K 22571D240K WG75H-03 WG75H-23 WG75H-43 WG75H-53 22636C102 225740101 22636C102 22574C102 22636G102 225740102 22636C102 22574C104 22571D225K 22571D231K 22571O231K 22571O240K *Wastewater. Pumping Station* **Design Analysis** Project West Union Elementary School Union County, North Carolina By: DPR 1. Determine Force Main Size Peak Design Flow, Qp Pipe Dia., Dfm Pipe Area, Afm Velocity, Vfm Il. Determine Wetwell Size Min. Cycle Time, t Pump Discharge Rate, q Inflow Rate to Wetwell, Q 30,000 Gpd 63 Gpm 3 Ins 0.25 Ft 0.0491 Sf 2.84 Fps 30 62.5 25.0 Min Gpm Gpm tl)iawd aw r; Wetwell Dia., Dww Wetwell Area, Aww Drawdown Vol., Vs 5.0 Ft 19.63 Sf 469 . Gal 63 Cf ;StarageBHt. h III. Set Wetwell Control Elevations Top of Slab El. Influent Invert El. High Water Alarm El. Pump No. 2, On El. Pump No. 1, On El. Pumps Off El. Wetwell Flr. El. Bottom of Slab El. 680.00 Ft 673.10 Ft 672.60 Ft 672.10 Ft 671.60 Ft 668.41 Ft 666.91 Ft 666.41 Ft Prepared by David P. Rector, PE Page 1 of 3 [Reference] [Pump Discharge Rate, q] [GPDI(T x 60)] [(PI x DfmA2)/4] [Vfm>2.0fps] [Peak Flow] [ADF] [t = Vs/q/2 + Vslq-Q] [Vs = tg14] [(PI x Dww"2)14] [cf = 7.48 gal] [ht = Vs/Aww] [Manufacturer's Recommendations] [Exist. Influent elev.] [lnfl. El. - 0.50 Ft] [HWA EL - 0.50 Ft] [Pump No. 2 El. - 0.50 Ft] [Pump No. 1 El.; top of pump] [Pumps Off El. -1.5 Ft] [Wetwell Flr. - Slab Thickness] Pest Union Eletnantar Sch Union County, North Carolina By; DP .. 1V, Determine Total Dynarnic Head, TDH [Referen stewater Pumping Station* "*Design Analysis** . El. of Force Main 601 „20 Ft Pumps Off El, 667,88 Ft 23,32 Ft Lic Head, Hs ength of Force Main, Lim 10,910 Ft Friction Factor, C 150 Peak Design Flow, op 73 Gpni Pipe Neu Dfm 3 ins 143,01 Ft ion Head, Hf1 r Friction Head„ Hf2 2,05 Ft Equity, Length of Minor Losses, Le 156 Ft Total Friction Head, Hf 145i05 Ft 0,00 Ft Head, Hp Total Length of Pipe, L stern Cury Design ROW Hf Hs TDH Gpm] [Ft] [Ft] [Ft] 066 Ft 0 23 23 20 23 43 72 23 96 53 23 16 260 23 284 EI-Pu P' fEL] [PVC 1120, ATM G-2241, PC 200, SDR [Hf T 10.44LQ 85/C'1.65Dins44>665 ] [Hf Hf1 + Hf2] [Connects to prop, Blythe Creek Outfall] [TDH Hs + Hf + HF] [L Lfi + Le] [Flyght Model No, C-3127; Impeller 262] Pump Pump Flaw TDH [Gm] [Ft Prepared by David P. Rector, PE Page 2 of 0 182 25 176 50 160 75 14E 95 100 WdD MO-1d TOTAL HEAD FEET en 0) 0) N 0 0 0 CJ CY) 0) 0 0 L .e. Limited to intermittent duty r -= Cavitation Limit' * INPUT KW • • ■ ■ ■ 1 Mobile Power 1800 RPM Diesel Standby Power Ratings Prime Power Ratings Made In LSA Gerera'lor available wRh ©r without trader Saldor ll obile Power Gen alto Features ✓ Brushless alternator for long life, low maintenance Voltage regulation 1/2% 60 Hertz frequency Industrial grade Tier 2 John Deere engine Glow plugs FueVwater separator Electronic governor Digital Controller with analog gauges. Automatic safety shutdowns with digital readouts for low oil pressure, high water temp, engine overcrank and engine overspeed. Low fuel level shutdown (user select), battery disconnect switch, voltage adjust pot. ■ Analog gauges and meters for engine oil pressure, coolant temp., battery volts, and generator output volts, hertz, amps with phase select II Illuminated instrumentation panel ■ Main Circuit breaker for main power connection ■ Circuit breakers for single phase receptacles ■ Battery charg 1111 Shore X Single phase receptacles are powered during all main voltage configurations • Heavy gauge steel sound attenuated enclosure with internally mounted muffler. Durable powder coat paint finish. Pad lockable doors I Single point lifting eye ■ Long run, internal,, single wall XLPE fuel tank III 6 bolts to remove generator from trailer ▪ Premium grade DOT approved single axle highway trailer featuring: Torsion bar suspension, plastic corrosive resistant fenders, front leveling jack, running fights„ hydraulic brakes, lighted license plate bracket III Generator available with trailer (TS35T) or without trailer (TS35S) II 3" pintle hitch IN Battery included ■ Warranty: - limited 3 year warranty - 1 year or 3000 hours parts and labor - 3 year or 3000 hours parts Generator Specifications - PreJunint Standby Output 125°C Rise Single phase @ 240V...... 3 phase @ 208V,......... 3 phase @= 240V ..... , .... . 3 phase @ 480V...„,....... Prime Output 105°C Rise Single phase @ 240V... , .. . 3 phase @ 208V ...... 3 phase @ 240V .. . 3 phase @ 480V........ Amperage (Standby Rating) Single phase amperage @ 240/12 3 phase amperage @ 208V 3 phase amperage @ 240V .. 3 phase amperage @ 480V .. V . . kVA/k W 25/25 37/30 37/30 37/30 kVA/kW . , 22/22 33/27 27 33/27 Amps 104/2%104 104 . 90 45 Voltage-3 phase adjustable 208/20/240/416/440/460/480 Voltage -Single phase adjustable 120/127/139/240/254/277 3 phase Power Factor.. . .. . ............... 0,8 1/2% 60 Hertz 5% . Class H Voltage Regulation ..... Frequency ............. Total Harmonic Distortion . Insulation ............. Engine Specifications Manufacturer .......... . Model ................. Cylinders ............. . Induction system... Displacement, L (cu, in.). EPA Emissions Level ... . HP @ rated speed ...... Bore and stroke. — „ . .... . Lubrication capacity (with filter). , e , .. ..... , ... 8.5 Qts Battery recommendation (min. cold cranking amps).... 675 - Battery, battery rack and cable supplied - Spin -on oil filter - Thermostat controlled liquid cooling system 12V engine alternator - 12V starter motor . John Deere 4024TF270 4 Turbocharged 2.4L (149) .. Tier 2 ..48 1800 3.4" x 4,1" Receptacle Specifications 120 Volt 20 Amp Duplex GFCI ... , ....... . 120/240 Volt 50 Amp Twistiock (C56369) .. Two wire remote start capability . _ . , .. , . . 2 ..2 . Yes Fuel Sys Specifications Fuel Consumption Standby Rating Full load ............ Approximate Run Time 1/2load ............. Full load ............. Fuel Capacity Gallons ..... . ...... . Fuel.. — GPH 1.4 . 2,8 Hours .,36 ,18 50 el Weights and Dimensions Weight without fuel .... . ............. . ... . . 2710 Weight without fuel and without trailer . , ..... „ 2150 Dimensions with trailer (L x W x H) 137" x 62" x 71" Dimensions without trailer (L x W x H) . 74" x 38" x 54" Sound Level Sound level dB(A) . . 7 meters, full load Start/Stop/Auto Switch, Alarm Horn, V Pot, Battery Disconnect Switch, Trailer and Running Lights. . 67 age Adjust ide Markers Ratings: - Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility poweroutage, No overload capability for standby rating, Standby ratings in accordance with ISO 3046. BSS5114, DN 6271. (Prime Power Rating: Prime power is the maximum power available for continuous duty. A 10°/. overload capacity is available for 1 hour out of 12 hours of operation. Manufacturer reserves the right to implement specifications or design changes without notice, WARNING_ Do not connect generator to any building's electrical system unless a disconnect switch has been installed„ Distributed by: NATIONAL PO 'i ER CORPORATI-ON P.0, Dor 56729 • Rnkl)11- 11kaN GaaxHlwia s7658 19141 790-1672 r,10,5191 790`9714 5100 Gepanwe Dr. • ralerp, ('loth ELA.1.1:4'a4raaa" _. Baldor Electric Company F & x 2400 • Fort Smith, AR 72902-2400 U.S.A. Phone (479) 646-4711 • Fax {479) 648-5792 • International Fax (479) 14/ www.baldcr.00rn Pttnie0 in U E,A. 41106 FARR n250L1 Section 2 General information Thank you for purchasing your Baidor Generator Set. This manual contains information you need to safely and efficiently install and operate your generator set. During the preparation of this manual every effort was made to ensure the accuracy of its contents. This manual describes only very basic engine information. A separate owner's manual for the engine is supplied with this unit for your use. Please refer to the engine manual for information relative to engine operation, maintenance, recommendations and additional safety warnings. Copyright Baldor © 2006. Ali rights reserved. This manual is copyrighted and all rights are reserved. This document may not, in whole or in part, be copied or reproduced in any form without the prior written consent of Baldor Electric Company, Inc. Baldor Generators have earned the reputation of being high quality and dependable. We take pride in this fact and continue to keep our quality standards high on our list of priorities. We are also constantly researching new technological ideas to determine if they could be used to make our generator sets even better. Baldor makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of fitness for any particular purpose. The information in this document is subject to change without notice. Baldor assumes no responsibility for any errors that may appear in this document. Limited Warranty Baldor will replace or repair free of charge any part or parts of the generator of their manufacture that are defective in workmanship and materials for a period of time as set forth in the Warranty Period chart below. All Baldor products requiring warranty service shall be transported or shipped freight pre -paid to a Baldor Generator repair facility. Notification of the defect or problem, a description of the manner in which the Baldor generator is used, and the name, address and telephone number of the customer requiring warranty service must be included. Baldor is not responsible for removal and shipment of the Baldor product to the service center or for the reinstallation of the Baldor product upon its return to the customer, or any incidental or consequential damages resulting from the defect, removal, reinstallation, shipment or otherwise. Problems with Baldor products can be due to improper maintenance, faulty installation, non-Baldor additions or modifications, or other problems not due to defects in Baldor workmanship or materials. If a Baldor Generator repair facility determines that the problem with a Baldor product is not due to defects in Baldor workmanship or materials, then the customer will be responsible for the cost of any necessary repairs. Genset engines are covered under the engine manufacturers warranty. Proper engine maintenance is required. Any request for engine warranty or repair should be made directly with the engine manufacturers warranty center. See engine manufacturers data for applicable engine warranty periods and location of repair centers. This Limited Warranty and Service Policy represents Baldor's sole and exclusive warranty obligation with respect to Baldor products. Baldor's liability to a customer or any other person shall not exceed Baldor's sales price of the applicable Baldor product. BALDOR DISCLAIMS ALL OTHER EXPRESSED AND IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. Warranty Period Generator Series Labor* Parts Portable Products (Premier, Powerchief, DG Series) 1 Year 3 Years Towable Products (TS) 1 Year or 3,000 Hours 3 Years or 3,000 Hours POW'R LITE Light Towers 1 Year or 3,000 Hours 3 Years or 3,000 Hours Light Fixture, Lamps and Ballasts are excluded from any warranty coverage 3600 RPM Standby Systems (Some AE Models) 1 Year or 1,000 Hours 3 Years or 1,000 Hours 1800 RPM Standby Systems (Some AE Models, DLC, GLC) 1 Year or 3,000 Hours 3 Years or 3,000 Hours Industrial Standby Systems 1 Year or 1,000 Hours 2 Years or 1,000 Hours Industrial Prime Power Systems 1 Year or 1,000 Hours 1 Year or 1,00o Hours International 1 Year or 1,000 Hours 1 Year or 1,000 Hours *For products covered under labor coverage, travel expenses will be allowed up to 7 hours straight labor or 300 miles, whichever occurs first, and only applies to permanently wired and mounted products (AE, DLC, GLC, IDLC). You must save the purchase receipt. Proof of purchase, date, serial number and model number will be required for all portable and Towable products to qualify for any warranty consideration. A start-up inspection form/warranty registration must be completed in its entirety and submitted to Baldor Generators within 30 days of start-up to qualify for any warranty consideration, excluding: Portables, Towables and Light Towers. MN2417 General Information 2-1 Automatic Transfer 100 - 400 Amps, Transfer Switches 1 00 - 400 Amps, 600 VAC Submittal 100A, 3 Pole, 60 Hz, 480 VAC,3 Phase. . NE{UTA:9 X fENERAC GTS S V STEnn El 0 0 1 • Standard time delay neutral will reduce switchover problems. • Logic control with inphase monitor regulates switch functions and allows adjustable switch settings with LED indicators. • Control switches located on the front of the door for ease of operation. • All switches are UL 1008 listed and CSA certified. • Electrically -operated, mechanically -held contacts forfast, positive connections. • Rated for all classes of Ioad, 100% equipment rated, both inductive and resistive with no derations. • 2, 3, and 4 Pole 600 VAC contactors. • 160 millisecond transfer time. Standard Features • Single coil design, electrically operated and mechanically held • Programmable exerciser • SPDT auxiliary contacts • Main contacts are silver alloy to resist welding and sticking • Conformal coating protects all printed circuit boards • indicating LED's for switch position —Normal, Emergency, and Standby Operating • NEMA 1 enclosure with hinged door and key -locking handle • Three -position switch —Fast Test, Auto, Normal Test • Arc chutes on main contacts Optional Accessories • NEMA 12 enclosure • NEMA 3R enclosure • NEMA 4 & 4X enclosure • Exterior AC meter package • Controls accessible through door in door design on NEMA type 3R and 4 enclosures — key lock provided on access door • 4-pole design for neutral isolation • Two (2) sets of auxiliary contacts • Preferred source selector switch • Manual 3 position selector switch • Remote automatic control circuit • Signal before transfer contacts • Return to normal timer bypass GENERAC° POWER SYSTEMS, INC. GENERAC•POWER SYSTEMS, INC. - P.O. BOX8 • WAUKESHA, WI 53187 262/544-4811 • FAX 262/544-4851 GTS Control Systems LOGIC CONTROL w / Inphase Monitor Utility Voltage o Dropout 75-95% (Adj.) Pickup 85-95% (Adj.) Line Interrupt 0.1-10 Sec. (Adj.) Engine Minimum Run 5-30 Min. (Adj.) Engine Warmup 5 Sec.-3 Min. (Adj.) Return to Utility 1-30 Min. (Adj.) Engine Cooldown 1-30 Min. (Adj.) Standby Voltage 85-95% (Adj.) Standby Frequency 80-90% (Adj.) Time Delay Neutral 0.1-10 Sec. (Adj.) Transfer on Exercise On/Off Switch Warmup Timer Bypass On/OffSwitch Time Delay Neutral Bypass OnfOff Switch On/Off Switch Inphase Monitor Withstand Current -f IQa.'(olt GTS Series GTS Rated Amps FUSE PROTECTED Maximum RMS Symmetrical Fault Current — Amps Maximum Fuse Size — Amps Fuse Class CIRCUIT BREAKER PROTECTED Maximum RMS Symmetrical Fault Current — Amps Protective Device Continuous Rating (Max) — Amps 100 200,000 200 J,T • Tested in accordance with the withstand an • Current ratings are listed @ 480 VAC M2 Q 14,000 150 150 200,000 400 J,T 200 200,000 400 J,r 25,000 25,000 300 300 c osiT n^quirements of UL 1008 and CSA Standards D1 Unit Dimensions r_D2 CTS Rated Amps 100 150-200 150-200 Voltage ALL 120/240 120/208 Enclosure Height H 36 36 36 Enclosure Width W 24 24 24 • • Ilse Installatrot7 drawings for dttnenstons 0• �vfi ,� ,s:d5+. hyc r3 kr^` v"� r. •. +� t t_;':' .,4?. N� `.Jt2v -rvv 300-400 300-400 300-400 1 i VI Ctii 120/208 277/480 600 iv 36 48* 48* 4 24 30* 30* 300 200,000 600 J,T 400 200,000 600 J,T 35,000 35,000 600 600 Wall Mount Bolt Paftern Enclsoure Depth M1 18 18 18 24 24 18 18 24 24 M2 37.5 37.5 37.5 49.5 49.5 37.5 37.5 49.5 49.5 D1 12.7 12.7 12.7 14.8 14.8 12.7 12.7 14.8 14.8 D2 10 10 10 12 12 10 10 12 12 Weight (Ibs.) 180 185 185 265 265 245 245 325 325 • Note: On NEMA 1 enclosures only, door overlaps enclosure — door dimensions are 48.8 H X 30.8 W. All dimensions in inches. Terminal Lug Wire Ranges GTS Rated Amps 100 150 200 300 400 Contactor Terminals (1 Lug Per Pole) Lug Wire Range 2/0 — 14AWG 400MCM — 4 AWG 400MCM — 4 AWG 600MCM — 4 AWG [250MCM — 1/0 AWG] " 600MCM —4 AWG [250MCM — 1/0 AWG] # Lugs 4 4 4 4 4 Neutral Bar Lug Wire Range 2/0 — 14AWG 350MCM — 6AWG 350MCM — 6AWG 600MCM — 4 AWG [250MCM -1/0 AWG]" 600MCM — 4 AWG [250MCM —1/0 AWG].* Ground Lug (1 Provided) Lug Wire Range 210-14AWG 350MCM — 6 AWG 350MCM — 6 AWG 350MCM — 6 AWG 350MCM — 6 AWG 350MCM — 6 AWG Bulletin 094700000S / Printed in USA 11.97 rev: 06.03 0E6711 I 031 I32.71) EXTENDED DOOR DIMENSION AT 90' 7613.00] r CURRENT TRANSFORMER CONNECTION 936E36.85] 9'4E36.0) 699E27.54] 508E20.02) 457I 7.99] 489C19.27] 215[0.451 1410.550 r REMOTE AUTOMATIC CONTROL CIRCUIT --I CONNECTION 610C24.0) 573E22.54] 450I17.71] 420[16.533 390[15.35] 457E 18.001 GENERATOR START CONNECTION r SIGNAL BEFORE TRANSFER CONNECTION 520E20.47] 160' SVING FROM CLOSE TO OPEN 811.1[O0.441 (TYPICAL) AT S MECMANISN AUXILIARY CONTACT (CUSTOMER) UTILITY SENSING INTERFACE GROUND TERMINAL WERE RANG£= 1114-2/0 AVG rr _CONTROL PCB ENCLOSURE ''',,__CONTROL ON DOOR) WALL MOUNTING BRACKET ■ - OPTIONAL UTILITY/NORMAL CONNECTIONS' VIRE RANGE. a6-2/0 AVG GENERATOR/STANDBY CONNECTIONS WIRE RANGE. a6-2/0 AVG NEUTRAL CONNECTIONS WIRE RANGE. 4 x a14-2/0 AVG CUSTOMER LOAD CONNECTIONS VIRE RANGE a6-2/0 Au0 148E5.841 12E5.031 70(3.07) L287C11.29)----i 3 5 6 .71 ICC CCIVI IT LA0oJT N/A - d N/A nu/. 7RGov • JJJ 1JO AS 7 1/13,04 MODNEWABRAMV.Iii 0(6711AVG 1• 1 . 4 h GIS 0E6711 1 9 Lts2oltM Michael F. Easley, Gove William G. Ross Jr., Secr, North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality April 16, 2007 Ms. Christie Putnam, Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Subject: Permit No. W00022768 Modification West Union Elementary Union County Public Works Union County, North Carolina Dear Ms. Putnam, In accordance with your application received on February 27, 2007, we are forwarding herewith Permit No. WQ0022768, dated April 16, 2007, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. This permit provides for the construction of a 20,550-foot force main segment. Due to odors and corrosive issues that would be expected when the line is not operating at design capacity, it is suggested that the Permittee implement a maintenance program that will address any such negative effects. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper NorthCarolina ✓Vaturay Ms. Putnam Page 2 April 16, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 68 linear feet of 8-inch gravity sewer, 10,913 linear feet of 3-inch force main, a 63 gallon per minute pump station (with duplex pumps, on -site audible and visual high water alarms, and a permanent generator w/ATS), as part of the of the West Union Elementary School project and the discharge of 12,000 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received February 27, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County WWTP (Twelve Mile Creek NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, ------7/ /(_-- for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Collection System Permit File Denver Toler, Eagle Engineering Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the fife of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 i Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 16th day of April, 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Z:7 - - . /C - - - - for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0022768 Modification 3 Fast Track Engineering Certification Permit No. WQ0022768 Modification April 16, 2007 Mr. Christie Putnam Union County Public Works 400 North Church Street Monroe, NC 28112 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of West Union Elementary, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. )N for ViITY SEv'ERS, PUMP STATIONS, AN FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Owner: Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) b. Christie L. Putnam, P.E., Director of Union County Public Works Application Number: (to be completed by DWQ Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) The legal entity who will own this system is: Individual ❑ Federal 0 Municipality State/County 0 Private Partnership ❑ Corporation 0 Other (specify): Q 1 d. 400 N. Church Street Mailing Address 1f. North Carolina Z State • 1 h. (704) 296-4210 Telephone Facsimile — 1 2a. D. Q. 1 i. (704) 296m42 2 Project (Facility) Information. West Union Elementary WWPS and Force 'Main Brief Project Name (permit will refer to this name) Contact Person: Denver D. Toler. P,E.IEayle Engineering Name and Affiliation of Someone Who Can Answer Que le, Monroe City l g. 28112-4804 Zip Code cputnam@co.union.nc.us E-mail 2b, Union County Where Project is Located ions About this Application 3b. (704) 882-4222 3c, dtoler@eagleonline.net Phone Number E-mail t Project is 0 NewModification (of an existing permit) If Modification, Permit No.: WQ0022768 For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc,). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choo 0 Retaining Ownership (i.e, store, church, single office, el Z ❑ Leasing units (lots, townhomes, etc. - skip to item B(3)) ❑ Selling units (lots, townhomes, etc, - go to Item 8(2b)) 3, Union County 0 Q LL Z • Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, Twelve Mile Creek Wastewater Treatment Plant 4b. NC0085359 Name of WWTF WWTF Permit No. 5a. Union Count + j5b 18'" Gravity Vic_ WQ0621594 Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main Permit Number of Downstream Sewer (if known The origin of this wastewater is (check all that apply): Residential Subdivision © Apartments/Condominiums 0 Mobile Home Park School Restaurant ❑ Office ❑ Car Wash O Institution 0 Hospital ❑ Church O Nursing Home ❑ Other (specify): Volume of wastewater to be allocated for this particular project: ( — *Do not include previously permitted allocations 500) 100 % Domestic/Commercial % Industrial % Other (specify): If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected F.t"A 02/03 - Rev, 3 04/05 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AN FORCE MAIMS PAGE 4 z 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). 800 students @ 15gpd 12,000gpd (Original permit included 62 single family residences which are to be removed from permit (-22,500gpd)) 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8" 4„ 3"° Length (feet) -32 -10,887 10,913 Gravity or Force Main (use the pull down menu) Gravity Force Main Force Main NTER TOTAL LINE LENGTH IN MILES 2,07 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option. (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator wIATS; 3 plans for cross-reference) (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage) WVVPS 0.012 63 @ 127,6 2 — permanent generator w/ATS 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable? Yes © No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? E] Yes E1 No N/A Yes (] No [] N/A Stormwater? Yes Q No N/A. 14, Does this project involve aerial lines or siphons? Check if yes: Q These lines willbe conssdered hiah priority and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? 0 Be aware that the Division will not accept installed lines more than 1 O% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. Sedimentation and Erosion Control Plan? ETA 02/03 - Rev, 3 04,05 APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality © regional office (see instructions for addresses) OR indicate the following: 0 © A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, Location ID on Map If chosen - as shown on map for cross-reference) A B Name of Waterbody Blythe Creek McNeeley Branch UNT McNeeley i ranch County Union Union Union River Basin Catawba Catawba Catawba Waterbody Strea Index 11-138-2-6-1 11 138-2-6 11-138-2-6 Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Waterbody Classification "CW Applicant's Certification: 1, Christie L. Putnam, attest that this application for West Union Elementary has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215,68, anyperson who knowingly makes any false statement, representation, or certification in any application shall be guilty of a:G`lass 2 misdemeanor which ma rn de a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, gning Officle. Sign lL Professional Engineer's Certification: I, Denver D. Toler, P.E., attest that this application for West Union Elementary has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seat signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215, 6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Denver D. Toler, P.E. Professional Engineer Name 2b, Eagle Engineering, inc. Engineering Firm 2c, 2013 Van Buren Avenue Mailing Address 2d, Indian Trail City 2g. f 704)882-422 Telephone 2e, NC 2f. 28079 State Zip 21, dtoler r eonline.net ignature & Date FTA 02103 - Rev. 3 04/05 pr / AND t147:-...,-"rt; t2ooREs-el_i OFFICZ • -•z.1 FEB 2 72007 )- liVATErYQ' .!TY Topo Map Page 1 of 4 0.4 0.6 0.8 1 rot UTM 17 57.64466E 3864496N (NA©27) USGS Waxhaw (NC) Quadrangle Projection is UTM Zone 17 NAD83 Datum http://www.topozone.corn/print.asp?tat-34.9243t"&.1on=-80.71024&size=l&s. show=n&... 2/12/2007 Permit Number WQ0022768 Central Files: APS SWP_ 04/13/07 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 12000 Facility Facility Name West Union Elementary WWPS and Force Main Location Address Owner Status Active Project Type Major modification Version Permit Classification 1.10 Individual Permit Contact Affiliation Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Orig Issue App Received 07/01/03 04/13/07 Regulated Activities School Subdivision Outfall NULL Scheduled Draft Initiated Issuance Owner Type Government - County Owner Affiliation Christine Putnam, Director Interim 400 N Church St Monroe NC 281124804 Public Notice Issue Effective 04/13/07 04/13/07 ReauestedlReceived Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS Christie L Putnam, P.E, Public World Director February 23, 2007 Ms. Dee Browder NC DENR Mooresville Regional Office 610 East Center Ave. Suite 301 Mooresville, NC 28115 Re: Modification of Permit #WQ0022768 Western Union Elementary WWPS & Force Main Dear Ms. Browder, Union County Public Works Dep cent wishes to modify the Western Union Elementary WWPS & Force Main permit. The reasons for the modification are; 1) To delete 62 residential homes from the permit (- 22,500 gpd) 2) Change the force main from 4" to 3". 3) Delete 32' of 8" gravity. If you have any questions please don't hesitate to call. (704) 296-4254 Sincerely; /1" Neal Gaston CIP Manager file 400 North Church St. • Monroe, North Carolina 28112-4804 • Phone: (704)296-4210 • Fax: (704)296-4232 UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Dee Browder ANDTA-/..1ViW _- I TTAL ly9o0RESV 1.'_F ^,2,O'dAL.OFFICE FEB 2 7 2007 WATER QUALITY SEC I23/07 Regarding: Modification - Permit #WQ0022768 Western Union Elementary WWPS & Force Main We are sending you: ['Copy of letter ❑ Plans ❑ Prints ❑ Shop Drawings ® Other Copies Date No. Description 1 2/13/07 Original Non Discharge Permit Application 1 2/13/07 Copy Non Discharge Permit Application 1 2/22/07 345690 Check for $400.00 1 7/1/03 Copy of Original Permit 1 2/23/07 Reason for modification These are transmitted as checked below: ® For approval ❑ For your use ❑ As requested ❑ For review and comments Remarks: Signed: /:/t Received by: Date: Beverly Eaves Perdue, Governor Dee Freeman, Secretary North Carolina Department of Environment and Natural Resources =r Coleen Sullins, Director -c Division of Water Quality January 13, 2009 Union County Public Works 500 North Main Street Suite 500 Monroe, North Carolina 28112 • SUBJECT: West Union Elementary School Permit No. WQ0022768 Modification Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on December 22;-20O8: Afull review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this fetter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from htto://h2o.enr.state.nc.us/ndpu/ndpuapps.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Robert Krebs 1 tl Surface Water Protection Regional Supervisor Enclosure Cc: Surface Water Protection Section Central Files (certification page only) Please forward copy to Engineer One: - Pretreatment, Emergency Response and Collection Systems Unit Internet httpllh2o.enr.nc.state.uslndpu NorthCarolina 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal opportunity Action Employer Naturally Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper .Fast Track Engineering Certifii lt�at�t Permit No, WQ0022768 Modification April 16, 2007 Mr. Christie Putnam Union County Public Works 400 North Church Street Monroe, NC 28112 Cornplete and submit this form to the permit issuing regional office with One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be dearly identified on the record drawings or in written ry form. Permit modifications are re wired far an changes resultin in non-com fiance with thi ninin um design criteria. This pr..Crja r t st ii riot he considered corn' 1 t.ea nor aUo yr rl ttr operate r..In t E dais, Eng nee required s upporti t > v,. r; „e.ntatt n have been r e eived lay tt c Divisi r . Therefore, it is highly recommended that this certificaatinn tea seat tea a manner that providers proof of receipt by the Division. ulations ENGINEER'SCERTIFICATION 0 Partial final V�I , I'++ ji rie C � as a duly registered Professional Engineer in the State of North Carolina, having been uthorized to observe (periodically, Lj weekly, Lj full time) the construction of West Union Elementary.,, a Union .;ounty project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T, the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/2.96--4232 To: NCDENR Division of Water Quality 610 East Center Ave., Suite 301 Mooresville, NC 28115 Attention: Surface Water Protection Regarding: WQ0022768 West Union Elementary We are sending you: [] Copy of letter Plans [] Prints 0 Shop Drawings Other opies Date 1 12/17/08 Description Engineers Certification elected Pumps Design Analysis w/ Sstern Curve Operating Point Selected Generator elected Automatic Transfer Switch These are transmitted as checked below: For approval D For your use 0 As requested 0 For review and comments Remarks: Sign Received by: Date: TRANSMt TTAL Date: 12/17/08