Loading...
HomeMy WebLinkAboutSW4210803_Plansheet C-4.0 - Grading/Drainage Plan_20220120LEGEND PROP. GRAVEL/ABC STONE EXIST. MAJOR CONTOUR EXIST. MINOR CONTOUR PROP. MAJOR CONTOUR PROP. MINOR CONTOUR PROP. SCM EASEMENT PROP. STORM DRAINAGE EASEMENT PROP. PERIMETER BUFFER EXIST. GENERAL PURPOSE UTILITY EASEMENT GRADING NOTES 1. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFFSITE GRADING, WRITTEN PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY OWNER(S). 2. CLEARING AND GRUBBING SHALL BE PERFORMED WITHIN THE LIMITS SHOWN ON THE PLANS. ALL TIMBER, BRUSH ROOTS, STUMPS, TREES, OR OTHER VEGETATION CUT DURING THE CLEARING OPERATIONS SHALL BECOME THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF PROPERLY, AND SHALL BE EITHER REMOVED FROM THE PROJECT SITE BY THE CONTRACTOR, OR SATISFACTORILY DISPOSED OF ON -SITE WITH APPROVAL FROM THE OWNER. 3. WHEN UNDERGROUND OBSTRUCTIONS NOT SHOWN ON THE CONSTRUCTION DRAWINGS (ROCK, PIPING, ETC.) ARE ENCOUNTERED, THE CONTRACTOR SHALL PROMPTLY REPORT THE CONFLICT TO THE OWNER'S ENGINEER. ALL CHANGES MUST BE APPROVED IN WRITING BY THE ENGINEER BEFORE CONSTRUCTION CAN PROCEED. 4. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF ANY UTILITIES DAMAGED DURING CONSTRUCTION. 5. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR PROPER REMOVAL OF ALL CONSTRUCTION WASTE AND DEBRIS. ALL WASTE AND DEBRIS SHALL BE LEGALLY DISPOSED AT AN OFFSITE LOCATION. 6. ROAD SHOULDERS, SWALES, BACK -OF -CURBS, AND CUTIFILL BANKS SHALL BE COMPLETELY DRESSED BY THE CONTRACTOR AND SEEDED AS SOON AS POSSIBLE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF THESE AREAS UNTIL A PERMANENT STAND OF GRASS IS ESTABLISHED. 7. CUT AND FILL SLOPES OF ANY AREA SHALL NOT EXCEED THE RATIO OF 3:1, UNLESS NOTED OTHERWISE. N P . .... ...... ,. SON SON \� \ o 1 I R L o3 I I 00/0 .......�. o \tio .._....�........... I I PERMANENT DITCH (PD-2) / I '4.0�/ SEE SHEET C-8.1 FOR DETAILS/_/O \11 \ POWER o�KE \ E I \ \ HW#400 l � NCDOT +iSTD i838.02 RCP ( CLAS S � TCE iL•E 8 3 44.43�"^� .�, 0 �, fC G °1° H NCDOT STD 838.02 TC CO mod•." ' PERMANENT DITCH (PD-3) -5.00% 844.17 ' SEE SHEET C-8.1 FOR DETAILS 8ds „� SCM RISER + 4 � t �w � + 1 � 15' TEN CONSTRU( EASEME Go y 4 � ..M V b 4 PERMANENT DITCH (PD-1) SEE SHEET C-8.1 FOR DETAILS + 3.76It /° C Go f / �° 840 M M rn f �C 2.43%0 + � I SE Go f , -5.00/° „ ao • / RCp OTCB#201 hl I hIII ")„,dA�RD FES#200 844.14 G Ih,.,... a . 2.01 -3.74/° 1, I q I / °,l + Y + ,844.09 r , + + + + 30' GENERAL PURPOSE r= UTILITY EASEMENT 8. DRIVES SHALL BE GRADED IN ACCORDANCE WITH THE LINES AND GRADE SET BY THE ENGINEER. BEFORE PLACING CURB AND GUTTER OR BASE ON THE GRADED SUBGRADE, THE SUBGRADE SHALL BE COMPACTED TO 100% IN ACCORDANCE WITH AASHTO-T99 AND NCDOT SPECIFICATIONS SECTIONS 500, AND THEN SHALL BE PROOF ROLLED IN THE PRESENCE OF THE ENGINEER. PLACES THAT ARE FOUND TO BE LOOSE, SOFT, OR COMPOSED OF UNSUITABLE MATERIALS, WHETHER IN THE SUBGRADE OR BELOW IT, MUST BE DUG OUT AND REFILLED WITH SUITABLE MATERIAL. ALL EMBANKMENTS OR FILLS SHALL BE MADE IN SIX-INCH VERTICAL LIFTS OF SUITABLE MATERIAL. THE FILL SHALL BE ROLLED WITH A SHEEPS-FOOT ROLLER AFTER EACH LIFT, FOLLOWED BY A WHEEL ROLLER, EACH WEIGHING NOT LESS THAN TEN (10) TONS. 9. THE STONE BASE SHALL BE COMPACTED TO 98% OF THE MAXIMUM DENSITY OBTAINABLE WITH THE MODIFIED PROCTOR TEST (AASHTO-T180) BY ROLLING WITH RING OR TAMPING ROLLER OR WITH A PNEUMATIC TIRED ROLLER WITH A MINIMUM WEIGHT OF TEN TONS. WHEN COMPLETED, THE BASE COURSE SHALL BE SMOOTH, HARD, DENSE, UNYIELDING AND WELL BONDED. 10. FILL EMBANKMENTS SHALL BE FORMED OF SUITABLE MATERIAL PLACED IN SUCCESSIVE LAYERS NOT TO EXCEED MORE THAN SIX (6) INCHES IN DEPTH FOR THE FULL WIDTH OF THE CROSS-SECTION, INCLUDING THE WIDTH OF THE SLOPE AREA. NO STUMPS, TREES, BRUSH, RUBBISH OR OTHER UNSUITABLE MATERIALS OR SUBSTANCES SHALL BE PLACED IN THE EMBANKMENT. EACH SUCCESSIVE SIX (6) INCH LAYER SHALL BE THOROUGHLY COMPACTED BY THE SHEEPS-FOOT TAMPING ROLLER, 10-TON POWER ROLLER, PNEUMATIC -TIRED ROLLER, OR OTHER METHODS APPROVED BY THE ENGINEER. EMBANKMENTS OVER AND AROUND ALL PIPE CULVERTS SHALL BE OF SELECT MATERIAL, PLACED AND THOROUGHLY TAMPED AND COMPACTED AS DIRECTED BY THE ENGINEER. 11. ALL BACKFILL SHALL BE OF LOW PLASTICITY, FREE FROM ROOTS, VEGETATIVE MATTER, WASTE, CONSTRUCTION MATERIAL, AND OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND THE MATERIAL SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 12. ALL PROPOSED GRADES SHOWN ON THESE PLANS ARE FINAL GRADES. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE APPROPRIATE SUBGRADE ELEVATIONS. V NOTE: ELEVATIONS AND GRADES ARE AT TOP OF ABC STONE. THE TOP OF ABC STONE LAYERS SHOULD BE ALIGNED OUTSIDE AND INSIDE THE FENCE \ LINES WITH THE #57 STONE ABOVE. roN 3� O:z `� \ 'v �(_),? ON00 \ I I ..,.. 170 �No1 I I �110�� � I r + �r 9 i to , d? 1 / HW#300 15 CLASS IV RCP ' \CONC, HEADWALL ® / / HW#301.. / CONC. HEADWALL �' ............... / //' / ...... .. �... .. " ........... .... . .. , oo PROPOSED HEAVY DUTY CONCRETE g50,,, v DRIVEWAY APRON / e \ (WITHIN NCDOT RIW) f ff f,, f 0�4J�QOv��4 � . � I / v V \ \ \ / / \ �`so 41!� 10 855 No��No INPa ,H / , + v / + / \ .... ` 40' 0 GRAPHIC SCALE 20' 40' 80' 160' U 0 a� o � U (10).� U W O N — N r V (6 U N L ' O � Z r LL co) a� U) Q U rn c Q 0 U_ N d 00 a c o J 3 W NU)0-Z 3 \N .�9 LICENSE NO. - F-1407 = LL CEOm � 0 CO O 2 CO 2 O a F_ F_ W m J M v U F W CO a o w W � W z m L1J CD CD N N a O N 0 0 ZN PROJECT INFORMATION PROJECT MANAGER: DEB DESIGNED BY: JWF DRAWN BY: MSS PROJECT NUMBER: IV18.400 ORIGINAL DATE: TBD Know whafs below. Call before you dig. ( IN FEET) 1 inch = 40 ft. SHEET C-4.0