HomeMy WebLinkAboutSW6220101_Plansheet - Misc. Detail_20220119 (4)TO BE EXPOSED\ ECHANICAL JOINT TH GRIP RING nNE MIN 18" BRICK SUPPORT ON EACH SIDE OF PIPE 2" ° a ........... d MIM 6" d' TAMPED BACKFILL uiu nr 7d" Tuarnnm BRASS PIPE NIPPLE 2" DIA RICK TO OR LONGER TO BRING PIPE SUPPORT UP TO FINISHED GRADE VALVE BOX el CONCRETE BLOCKING PIPE NIPPLE 2" DIA MIN. 1/3 C.Y. AT 3000 P.S.I. COUPLING WITH 2" THREADED PORT NOTE: SEE TYPICAL VALVE BOX DETAIL NTS FOR BRICK INSTALLATION PLAN ELEVATION AO 24"xl8" RFrTANVrl ii OD V/ 0 CAST IRON + + + + + + + + + + + + + + + + 11" + + + M T R + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 16 3/4" ISOMETRIC NTS 5 VALVE BC EXCESS LOOPED IN BOX TRACER WIRE NOTE: NO. 1 DRILL HOLE METER BOX DETAIL FOR 3/4" SERVICE 1111111111i�1® NOTE: AT PIPE INTERSECTIONS, MULTIPLE VALVES, RUN WIRE UP AT ONLY ONE VALVE. SINGLE 12 AWG SOLID CORE WIR PLACE EMPTY VALVE BOX AT INTERVALS WHERE VALVES DO NOT OCCUR & PLACE TRACER WIRE IN BC" PRECAST CONCRETE PROTECTI -FINISHED GRA[ BOX P.V.C. PIPELINE 0 GATE VALVE TRACER WIRE TO BE LAID UNDERNEATH WATER LINE _MASONRY BLOCK NOTES: 1. DRILL HOLE IN VALVE BOX TO INSERT TRACER WIRE,BRING UP TO INSIDE AND ROLL UP AT LEAST 6"—B" EXCESS 2. PLACE TRACER WIRE IN VALVE BOX AT 1,000" INTERVALS OR AS NOTED ON THE PLANS, TYPICAL. 3. DO NOT SPLICE WIRE WHEN BEGINNING A NEW SPOOL. INSTEAD INSTALL A VALVE BOX AND ATTACH EACH WIRE WITH A NTS BRASS SCREW TO THE VALVE BOX. 9 TYPICAL TRACER WIRE INSTALLATION AS SHOWN PRECAST CONCRETE STEAMER EDGE CONNECTION OF ON PLANS PROTECTION RING ROAD 2 1/2" HOSE 01 CONNECTION W 6" G.V. & BACKFILL a U C. I. BOX 6" WATER STONE N LINE (7 C.F. MIN.) Q ry M m I d N BLOCKING (SEE NOTE) 4-3/4" TIE RODS WITH BRACKETS .. 6" HYDRANT TEE WEEP HOLE TO NOTE: (SEE DETAIL) REMAIN OPEN 1.)TIE HYDRANT TO MAIN LINE MASONRY BLOCK 2'-0" W/TIE RODS IN LIEW OF CONC. BLOCKING IN SANDY SOIL. 2.)MECHANICAL JOINTS USED WITH GRIP RINGS NTS 2 FIRE HYDRANT ASSEMBLY INSTALLATION LAYI N G CONDITIONS DESCRIPTION PROJECT USE TYPE 1 TYPE 2 TYPE 3 TYPE 4 EXISTING AS NOTED ON PLANS ROAD ROAD SHOULDER z z BACKFILL AS INDICATED X p �Z COQ Nr72 M NEW WATER LINE 45° BEND SERVICE LINE TO CORPORATION METER CONNECTION COCK-A.Y. MCDONALD OR EQUAL SERVICE SADDLE - A.Y. MCDONALD OR EQUAL STYLE HINGED 3891 FOR 3/4" SERVICE SADDLE - A.Y. MCDONALD OR EQUAL TRENCH WIDTH PIPE O.D. + 18" FOR PIPES UNDER 33" O.D. NOTE: PIPE O.D. + 24" FOR PIPES OVER 33" O.D. 1. "SERVICE CONNECTION" IN PROPOSAL TO INCLUDE SERVICE SADDLE, 45° BEND, CORPORATION COCK AND ALL LABOR INVOLVED IN MAKING A COMPLETE SERVICE CONNECTION. 2. SERVICE PIPING TO BE 3/4" SDR-9 PE TUBING 3. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE NTS 3 TYPICAL WATER SERVICE CONNECTION FLAT BOTTOM UNDISTURBED NOT USED. EARTH TRENCH, LOOSE BACKFILL NOTES: 1. INSTALL METER AT R/W 2. "TWO (2)-3/4" SERVICE LINES MUST BE INSTALLED INSIDE A 2 SLEEVE. 3. "TWO (2)-l" SERVICE LINES MUST BE INSTALLED INSIDE A 3" SLEEVE." 4. SLEEVES SHOULD BE SCHEDULE 40 PVC PIPE. 5. SEE DETAIL FOR SERVICE MATERIAL AND METER SETTING 6. SERVICE LINE SHALL BE 3' BELOW FINISHED GRADE OF DITCHES. FLAT BOTTOMED UNDISTURBED EARTH NOT USED. 7. CONDUIT MUST EXTEND PAST PREPOSED SIDEWALK. TRENCH. BACKFILL LIGHTLY >_ CONSOLIDATED TO CENTERLINE ~ LU w OF PIPE. wZ IL_ O J 1' R/W 6' PIPE BEDDED IN 4" MININUM ALL DUCTILE 3'MIN JOB EXCAVATED MATERIAL. IRON GRAVITY SIDEWALK BACKFILL LIGHTLY CONSOLIDATED SEWER LINE. TO TOP OF PIPE. 2" PVC SLEEVE W/ 3/4" CARRIER PIPE BEDDED IN SAND, GRANULAR MATERIAL OR GRADED GRAVEL TO THE DEPTH OF 1 /8 PIPE DIAMETER, 4" MIN. JOB EXCAVATED MATERIAL COMPACTED TO 4" ABOVE TOP OF PIPE. (APPROX. 95% STANDARD PROCTOR, AASHTO T-99) PIPE BEDDED TO ITS CENTERLINE +++++++ + ++++++\/ ++`++ IN COMPACTED GRANULAR MATERIAL +++`+ + ` + + + �j 4" MIN. UNDER PIPE. COMPACTED GRANULAR OR SAND MATERIAL TO +++ + + +++++ ++++++. % 4"ABOVE TOP OF PIPE. + + . \ \+\ + (APPROX. 959 STANDARD PROCTOR, (AO9 TYPE 5 6 TYPICAL LAYING CONDITIONS 1' FROM EDGE OF ROW o D_ 0_ i METER BOX LID, CAST IRON STREET ALL PVC WATER WATERMAIN LINE AND PVC FORCE MAIN. 12" MIN 0 SINGLE 3/4" SERVICES R/W METERS SHOULD BE >- INSTALLED 3' OFF W w PROPERTY LINE ILz OJ X CL ALL PVC GRAVITY SEWER LINE. NTS NTS 7 TYP. DOMESTIC WATER SERVICE DETAIL 9> Of W 0 U M 3/4 Inch Gate Valve Z Required on Customer side 2 3 " X 18" Within 12 inches of SERVICE LINE - B SS NIPPLE the Meter Box FROM STREET d METER SETTER CENTERED IN BOX METER TO BE INSTALLED P.R.V. Location down stream of the cut-off valve BRICK SUPPORT 1. METER AND SERVICE LINE NOT IN CONTRACT UNLESS SPECIFIED METER SETTER WITH DOUBLE CHECK VALVE 2. INCLUDE STONE IN PRICE OF METER BOX. (BACKFLOW PREVENTER) 3. METER SETTER SIZE AS NOTED ON PLANS. 4. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE. NTS 10 TYPICAL 3/4" METER BOX INSTALLATION ENCASEMENT DUCTII TOBE STORMSEWER� PIPE PLUS O.D. PLUS 2'-0" OR AS SHOWN ON PLANS. NTS 11 TYPICAL STORM SEWER CROSSING DETAIL FINISHED GRADE ° 2„ 1"� ° _,— BACKFILL TO EDGE n d ° a a ° PRECAST CONCRETE I I III —III— -IIII I PROTECTION RING J z Q Z W O N N Q VALVE BOX J VALVE OPERATOR NUT NTS 4 TYPICAL VALVE BOX DETAIL NOTES: 1. CONCRETE SHALL BE 3,000 PSI MIN. 2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE SHAPE MORE EASILY FORMED WITH THE WIDEST PART (BLOCKING AREA) AGAINST UNDISTURBED E 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLA 4. ALL PIPING AND ACCESSORIES TO BE WRAPPED WITH 10 MIL. POLYETHYLENE PRIOR TO POURINC BLOCKING. 5. VOLUME OF THRUST BLOCKING SHALL BE AS SHf ON THE THRUST BLOCKING SCHEDULE. x d e . 6" MIN. X MIN.1/3 C.Y. AT 3000 P.S.I. PLAN BENDS J" 0 OR LESS 24" MIN. — 12" 0 OR LESS X HYDRANT TEE PLAN TEES 18" MIN. 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 910-426-6777 fax I 910-426-5777 license number I C-2354 wwwAD site solutions.com PROJECT NAME WOODSHIRE SUBDIVISION PHASE 7 �� WATER DETAILS 000000000000 8 THRUST BLOCK DETAIL NTS CLIENT 1041 B Robeson Street Fayetteville, North Carolina 28305 Phone: (910) 339-6330 Fax: (910) 964-9089 PROJECT INFORMATION DESIGNED BY: CALEB DRAWN BY: CALEB CHECKED BY: SCOTT PROJECT NUMBER: 1070 DRAWING SCALE NOT TO SCALE DATE RELEASED JANUARY 17, 2022 SHEET NUMBER C-6m3