Loading...
HomeMy WebLinkAboutSW1210801_Supplement-EZ Form_20220118SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Pardee Partners Mills River- Road- Low Density 2 Project Area ac 17.411 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 0.279 5 Is this project High or Low Density? Low 6 1 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting (RWH 18 Green Roof 19 Level Spreader -Filter Strip LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Jared L. DeRidder, P.E. 28 Organization: WGLA Engineering, PLLC 29 Street address: 724 5th Avenue West 30 City, State, Zip: Hendersonville, NC 28739 31 Phone numbers): 828-687-7177 32 1 Email: jderidder@wgla.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. 04 *V,Ss/Q'J� .4 SEAL fir-: 041349 a") ai�� Sig re of Designer II /2,ZhoZl Seal Date DRAINAGE AREAS 1 Is this a hi h density project? No 2 If so number of drainage areas/SCMs 0 3 Does this project have low density areas? YES 4 If so number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM 5 Total drainage area (sq ft 758423 758423 6 Onsite drainage area (sq ft 758423 758423 7 Offsite drainage area (sq ft 8 Total BUA in project (sq ft) 182000 sf 182000 sf 9 _ New BUA on subdivided lots (subject to permitting) (sq ft 10permitting) New BUA not on subdivided lots (subject to s 182000 sf 182000 sf 11 Offsite BUA (sq ft 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft Sidewalk (sq ft 3485 sf 3485 sf Roof (sq ft Roadway sc ft) 20473 sf 20473 sf - Future (sq ft 158042 sf 158042 sf - Other, please specify in the comment box below (sq ft 13 New infiltrating permeable pavement on subdivided lots (sq ft _ ( l 14 New infiltrating permeable pavement not on subdivided lots (sq ft 15 Existing BUA that will remain (not subject to permitting) (soft 16 Existing BUA that is already permitted (sq ft 17 Existing BUA that will be removed (sq ft 18 Percent BUA 23.99% 23.99% 19 Design storm inches 20 1 Design volume of SCM cu ft 21 Calculation method for design volume ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): The proposed private roadway is crowned and will sheet flow off the edge of the road / sidewalk and sheet flow over the vegetated shoulder. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) NIA 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) N/A I} 8 Bottom width of curb outlet swale(s) (feet) N/A 9 Maximum side slope of curb outlet swale(s) (H:V) N/A 10 Minimum length of curb outlet swale(s) (feet) NIA 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 1 Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 1 Please use this space to provide any additional information about this low density project: Due to the nature of the surrounding area being flat, the runoff from the road will sheet flow over a vegetated shoulder with no collections stem or swales being proposed. Swale # Drainage Are Area (ac1 BUA (ac) Pervious area ac C Q (cfs) Slope ( % ) VA—V,�,,,, (fps) (fps) Flow depth (ft) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30