Loading...
HomeMy WebLinkAboutWQCSD0403_BIMS Report_20220114Compliance Inspection Report Permit: WQCSD0403 Effective: 11/16/10 Expiration: SOC: Effective: Expiration: County: Iredell Region: Mooresville Contact Person: Michael A Melton Directions to Facility: Owner : Aqua North Carolina Inc Facility: Mallard Head Collection System Title: Engineering Manager Phone: 704-489-9404 Ext.57238 System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0062481 Aqua North Carolina Inc - Mallard Head WWTP Inspection Date: 01/12/2022 Entry Time 12:15AM Exit Time: 01:15PM Primary Inspector: Tony Parker Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions In General Spills/Response Plan II Inspections Manholes (See attachment summary) Page 1 of 4 Permit: WQCSD0403 Owner - Facility:Aqua North Carolina Inc Inspection Date: 01/12/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Page 2 of 4 Permit: WQCSD0403 Owner - Facility:Aqua North Carolina Inc Inspection Date: 01/12/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General # Is this system a satellite system? # If Yes, what is system name or permit number? Is there a overall sewer system map? Does the map include: Pipe sizes Pipe materials (PVC, DIP, etc) Pipe location # Flow direction # Approximate pipe age # Pump station ID, location and capacity # Force main air release valve location & type # Location of satellite connections Are system maintenance records maintained? Comment: This is a private deemed system. Spills and Response Action Plan # Is system free of known points of bypass? If No, describe type of bypass and location # Have there been any sewer spills in the past 3 years? If Yes, were they reported to the Division if meeting the reportable criteria? If applicable, is there documentation of press releases and public notices issued? Are all spills or sewer related issues/complaints documented? # Are there repeated overflows/problems (2 or more in 12 months) at same location? # If Yes, is there a corrective action plan? Is a Spill Response Action Plan available? Is a Spill Response Action Plan available for all personnel? Does the plan include: # 24-hour contact numbers # Response time # Equipment list and spare parts inventory # Access to cleaning equipment # Access to construction crews, contractors, and/or engineers # Source of emergency funds # Site sanitation and cleanup materials # Post-overflow/spill assessment Yes No NA NE ▪ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ • ▪ • • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ Page 3 of 4 Permit: WQCSD0403 Owner - Facility:Aqua North Carolina Inc Inspection Date: 01/12/2022 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Comment: No SSO's reported for the review period. Inspections Yes No NA NE Are adequate maintenance records maintained? • ❑ ❑ ❑ Are pump stations being inspected at the required frequency? ❑ ❑ • ❑ Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ • ❑ Is there a system or plan in place to observe the entire system annually? • ❑ ❑ ❑ Is the annual inspection documented? • ❑ ❑ ❑ # Does the system have any high -priority lines/locations? ❑ ❑ • ❑ Are inspections of HPL documented at least every 6 months? ❑ ❑ • ❑ Are new lines being added to the HPL list when found or created? ❑ ❑ • ❑ Comment: The system has no HPL's and no P/S. Manholes Yes No NA NE Please list the Manholes Inspected: All 7 of 7 M/H's. No issues noted. Are manholes accessible? • ❑ ❑ ❑ # Are manhole covers/vents above grade? • ❑ ❑ ❑ Are manholes free of visible signs of overflow? • ❑ ❑ ❑ Are manholes free of sinkholes and depressions? • ❑ ❑ ❑ Are manhole covers present? • ❑ ❑ ❑ # Are manholes properly seated? • ❑ ❑ ❑ # Are manholes in good condition? • ❑ ❑ ❑ # Are inverts in good condition? • ❑ ❑ ❑ Is flow unrestricted in manholes? • ❑ ❑ ❑ Are manholes free of excessive amounts of grease? • ❑ ❑ ❑ Are manholes free of excessive roots? • ❑ ❑ ❑ Are manholes free of excessive sand? • ❑ ❑ ❑ Are manhole vents screened? ❑ ❑ • ❑ Are vents free of submergence? ❑ ❑ • ❑ Are manholes free of bypass structures or pipes? • ❑ ❑ ❑ Comment: No issues with M/H's and adequate records are mintained. Page 4 of 4