HomeMy WebLinkAbout20070741 Ver 2_Revised Fig 3-Site Plan - Wade Hampton Utility Crossing_20211217NOTES: 1. PRELIMINARY- DO NOT USE FOR CONSTRUCTION.THIS PLAN IS NOT INTENDED TO IN ANY WAY TO REPRESENT A DETAILED CONSTRUCTION DOCUMENT AND IS INTENDED FOR USACE NATIONWIDE PERMIT SUBMITTAL. 2. POST CONSTRUCTION STREAM CHANNEL MUST BE RESTORED TO PRECONSTRUCTION CONFIGURATION AND DIMENSIONS. PROPOSED 4" DIA. INTERNALLY RESTRAINED CL. 51 DUCTILE IRON PIPE SUBSURFACE STREAM CROSSINGS TO REPLACE EXISTING ABOVE GROUND WATER MAIN AND SEWAGE FORCE MAIN STREAM CROSSINGS BACKFILL TRENCH WITH NATURAL STREAMBED MATERIALS REMOVED FROM STREAMBED (COBBLES, GRAVELS & SANDS) FOR PIPE INSTALLATION. THE TOP 6" OF STREAMBED MATERIALS REMOVED SHALL BE STORED SEPARATELY IN A SAFE LOCATION AND REPLACED IN THE TOP 6 INCHES OF THE STREAMBED TO THE PRE -CONSTRUCTION CROSS SECTION, ELEVATIONS AND DIMENSIONS. USE FULL LENGTH 20 FT J SECTIONS OF 4" DIP TO MINIMIZE THE NEED FOR IN LINE JOINTS IN STRAIGHT SECTIONS OF PIPING. WHERE REQUIRED, IN LINE JOINTS ARE TO HAVE INTERNALLY RESTRAINED GASKET SYSTEM. MIN. 24" THICK, NCDOT CL. 1 CLEAN RIP -RAP ON WEST (RIGHT) BANK ONLY MINIMIZE STREAMBANK DISTURBANCE ON EAST (LEFT) BANK, RESTORE BANK TO PRE -CONSTRUCTION GRADES AND DIMENSIONS AND RE -PLANT AND STABILIZE ALL LEFT BANK DISTURBED AREAS WITH NATIVE, WOODY VEGETATION TO PROVIDE PERMANENT STABILIZATION OF ALL DISTURBED AREAS. TYPICAL BOTH WATER AND FORCE MAIN PIPELINE REPLACEMENT LOCATIONS. KEY RIP -RAP INTO SLOPE AND STREAM BED, RESTORING STREAM CHANNEL TO PRECONSTRUCTION ELEVATIONS, GRADES AND +L Q GEOMETRY. TYPICAL. J+�y NORMAL CREEK WATER LEVEL NATURAL + CREEK ++ � BED Y' ++++ x INTERNALLY RESTRAINED - x 2 FT xxx xxx MECHANICAL JOINT COUPLING AND FITTINGS AT CONNECTIONS TO EXISTING PIPING. INSTALL RIPRAP ON FILTER FABRIC, J MIRAFI 140N OR APPROVED EQUAL J Q Q Z,aLu my °7za LL0� m JI— w m m NO JOINTS ALLOWED IN 4" DIP SECTION UNDER STREAM BED AND FOR A MINIMUM OF 2 FT BEYOND THE EDGE OF WATER ON BOTH SIDES OF STREAM. VIEW LOOKING UPSTREAM PROVIDE INTERNALLY RESTRAINED BENDS, FITTINGS & JOINTS AS REQUIRED PER PLAN AND AS NEEDED FOR SITE SPECIFIC CONDITIONS PROPOSED 4" DIP SUBSURFACE STREAM CROSSING PIPING TO REPLACE EXISTING ABOVE GROUND WATER MAIN AND SEWAGE FORCE MAIN STREAM CROSSINGS NOTES: 1. CREEK CROSSING UTILITY INSTALLATIONS SHALL BE IN ACCORDANCE WITH REGULATORY REQUIREMENTS FOR A SITE SPECIFIC INSTALLATION. 2. INSTALL PROPERLY SIZED TEMPORARY HDPE CULVERT IN STREAM (CENTERED ON PROPOSED UTILITY CREEK CROSSING) AND COMPLETELY DIVERT STREAMFLOW THROUGH CULVERT USING TEMPORARY SAND BAGS. EXCAVATE BENEATH THE TEMPORARY CULVERT AND INSTALL THE UTILITY AT THE PROPER DEPTH BELOW THE TEMPORARY CULVERT AT THE PROPER DEPTH. BACKFILL THE STREAM BED PORTION OF THE UTILITY TRENCH WITH CLEAN, NATURAL STREAM BED MATERIALS CONSISTING OF COBBLES, FINE GRAVELS AND SANDS FREE FROM ORGANIC MATERIALS. USE A TEMPORARY HDPE CULVERT AND SANDBAGS TO DIVERT STREAM FLOW TO COMPLETE RIP RAP SLOPE PROTECTION ON BOTH STREAMBANKS AS SHOWN ON PLAN, KEYING INTO NATURAL GRADE. THE TEMPORARY CULVERT AND SANDBAGS MUST BE REMOVED AT THE END OF EACH WORK DAY AND UNDER THE THREAT OF RAIN EVENTS AS NEEDED TO PREVENT IMPACT THE FLOOD HEIGHTS AND AS NEEDED TO PREVENT EROSION DAMAGE. UPON COMPLETION OF ALL PIPE INSTALLATION, COMPLETELY REMOVE THE TEMPORARY CULVERT AND SAND BAGS AND RESTORE THE STREAM CHANNEL TO PRECONSTRUCTION DIMENSIONS AND CROSS SECTIONS. 3. AREAS TO BE GRASSED SHALL BE SOWN WITH A COMMERCIAL MIX PRE -PACKAGED OF NATIVE GRASSES AND WILDFLOWERS WHICH ARE NATIVE TO THE LOCAL AREA. NO SEED MIXES CONTAINING TALL FESCUE OR LESPEDEZA SHALL BE USED. TEMPORARY SEEDING SHALL CONSIST OF WHEAT, RYE GRAIN OR OATS. ANY EROSION MATTING, IF USED, SHALL BE FREE OF NYLON OR OTHER TYPES OF PLASTIC AND SHALL BE SHORT TERM, BIODEGRADABLE MATTING THAT DOES NOT POSE AN ENTANGLEMENT HAZARD TO WILDLIFE. ALL SEEDING AND MATTING PRODUCTS SHALL BE APPROVED BY THE ENGINEER PRIOR TO THEIR USE. WATER MAIN OR SEWAGE FORCE MAIN REPLACEMENT STREAM CROSSING SECTION NOT TO SCALE TYPICAL REPLACEMENT WADE HAMPTON GOLF CLUB rlGuxa Lofquist &Associates, Inc. SUBSURFACE PIPE PROPOSED REPLACEMENT OF POTABLE WATER & SANITARY SEWER STREAM xunnaex PL.4NNING ENGINEERING DESIGN so S N,_VC z9 F='a� 7ke 14>a jNSTALLATION CROSSING MAINS u ©.o PREPARED FOR: WADE IIAMPTON POA, INC. 3 Ol SrVISED I21h 21 CROSS SECTION 7ACKSON COUNTY, NORTH C.4ROLI\ A