HomeMy WebLinkAboutWQ0038060_Application (FTSE)_20220113Permit Number WQ0038060
Program Category
Non -discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
dean.hunkele
Coastal SWRule
Permitted Flow
322,387
Facility
Central Files: APS SWP
1/5/2022
Permit Tracking Slip
Status
Project Type
In review
Major modification
Version
Permit Classification
N
Individual
Permit Contact Affiliation
Facility Name Major/Minor Region
RiverLights Development Sewer Minor Wilmington
Location Address County
New Hanover
Facility Contact Affiliation
Owner
Owner Name
Cape Fear Public Utility Authority
Dates/Events
Scheduled
Ong Issue App Received Draft Initiated Issuance
11/3/2015,.. 12/22/2021
Owner Type
Government - Municipal
Owner Affiliation
Kenneth Waldroup
235 Government Center Dr
Wilmington NC 28403
�-
Public Notice Issue Effective
v�MCIQM&CREED
HAND DELIVER
TO:NCDEQ
127 Cardinal Drive Extension
Wilmington, NC 28403
ATTENTION: Dean Hunkele
DEC 26YTE F TRANSMITTAL
DATE: -December 22, 2021
PROJECT NO: 2735-0250
TASK NO:
RE: RiverLights — SF 5-6
Sewer Fast Track Submittal
Modification
TRANSMITTAL NO: 1
PAGE 1 OF 1
WE ARE SENDING: ® Originals ® Prints ❑ Shop Drawings ❑ Samples
❑ Specifications ❑ Calculations ® Other - Check
Quantity
Drawing No.
Rev.
Description
Status
1/1
Original and Copy: Application FTA 10-14
G
1/1
Original and Copy: FTSE
G
1
Permit Fee $480
G
1/1
Original and Copy: Sewer Narrative
G
1/1
Original and Copy: Associated Site Maps (Topo/Street View)
C
1
Copy of Permit WQ0038060
C
Issue Status Code: A. Preliminary B. Fabrication Only C. For Information D. Bid
E. Construction F. For Review & Comments G. For Approval H. See Remarks
Action Status Code: 1. No Exceptions Taken 2. Make Corrections Noted 3.Other
4. Amend & Resubmit 5. Rejected - See Remarks
REMARKS:
S: \2735\0250\IOLomm\19-Transmittal Letters\2021-12-22 SF 5-6 NCDEQ SEWER.doc
RECEIVED/NCDENR/DWR
..,,y�erry Reoional
Operations Section
Wilmington Regional OKce
243 NORTH FRONT STREET, WILMINGTON, NC 28401 (910) 343-1048 FAX (910) 251-8282
Signed
McKIM & CREED, INC.
Emily McArthur, EI
State of North Carolina
DWR
Department of Environmental Quality
Division of Water Resources
Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 06-21 & SUPPORTING DOCUMENTATION
Application Number: (to be completed by owR)
All items must be completed or the aoulication will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Cape Fear Public Utility Authority (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership
❑Privately-Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: Jeff Theberge, PE per 15A NCAC 02T 01061bi
Title: EngineerinS Manager
i
4. Applicant's mailing address: 235 Government Center Drive
City: Wilmington State: NC Zip: 28403-_
5. Applicant's contact information:
Phone number: (910) 332-6673 Email Address: Jeff.Theberge(a,cfoua.org
IL PROJECT INFORMATION:
I 1. Project name: RiverLiehts Conventional Phase 5 & 6 Modification
2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project
If a modification, provide the existing permit number: W00038060 MOD and issued date: 10/26/2021,
i
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of.a master plan, provide the existing permit number: W000_
3. County where project is located: New Hanover County
4. Approximate Coordinates (Decimal Degrees): Latitude: 34.1570Longitude:-77.938°
5. Parcel ID (if applicable): R07000-006-009-0000 (or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Kathryn Espinoza PE License Number: 040271
Firm: McKim & Creed. Inc.
Mailing address: 243 N. Front St
City: Wilmington State: NC Zip: 28401
Phone number: (910) 343-1048 Email Address: kespinoza!nlntckimcreed.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: M'Kean MAffitt (Southside) W WTP Permit Number: NPDES NC 002973
Owner Name: Cape Fear Public Utility Authority
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s): W 000 42385
2. Downstream (Receiving) Sewer Information: 16 inch ® Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCS_
Owner Name(s): Cane Fear Public Utility Authority
FORM: FTA 06-21 Page I of 5
vI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑ No ® N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational A ereement (FORM: DEV I been attached?
❑ Yes ❑ No ®N/A
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Acreement (FORM: HIOA) and
supplementary documentation as required by 15A NCAC 02T.01 15(c) been attached?
❑ Yes ❑ No ® N/A
4. Origin of wastewater: (check all that apply):
® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 %Domestic % Commercial % Industrial (See 15A NCAC L_j)
If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Hasa flow reduction been approved under 15A NCAC 02T .01141 )? ❑ Yes ®No
➢ If yes, provide a covv of flow reduction apuroyal letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow "•b
No. of Units
Flow
Residential
360 gal/day
33
11,880 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gav
GPD
Total
11,880 GPD
a See 15A NCAC 02T .01 14(b) (d). (e)(I ) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S_42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project:_ GPD (per 15A NCAC 02T .0114)
D Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
❑ Flow has already been allocated in Permit Number: Issuance Date:
❑ Rehabilitation or replacement of existing sewers with no new flow expected
❑ Other (Explain):
FORM: FTA O6-21 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravitc Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
8 554 PVC
Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section 1B contains information related to minimum slopes for gravity sewer(s)
Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (Pump Stations/Force Mainsl:
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -
3. Total number of pumps at the pump station:
3. Design flow of the pump station: — millions gallons per day (firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s): _ gallons per minute (GPM) at _ feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01 C.I.b. [:]Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) _
6. Power reliability in accordance with 15A NCAC 02T .0305(h )(1 ):
❑ Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
Y Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ if the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
FORM: FTA 06-21 Page 3 of 5
IX. SETBACKS & SEPARATIONS —(02B.0200 & 15A NCAC 02T.0305(i)):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0.0=05 (_0 & I c 1? ® Yes ❑ No
I5A NCAC 02T.0305(0 contains minimum separations that shall be provided for sewer s stems
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
18 inches
'Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
WWater mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
10 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
v It noncompliance with 02T.0305(f) or (g), see Section X.1 of this application
* I SA NCAC 02T.0 30Ae) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee
2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A
➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A
➢ Please provide supplementary information identifying the areas of non-conformance.
➢ See the Division's draft wparation requirements for situations where separation cannot be met.
➢ No variance is required if the altemative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No
If yes, does the project comply with setbacks found in the river basin rules per 15A. NCAC 02B 0200? ❑ Yes ❑ No
➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No
or 401 Water Quality Certifications?
➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required.
6. Does project comply with 15A NCAC 02T.01051 c 116) (additional permits/certifications)? ® Yes [:]No
Per 15A NCAC 02T.0105(c )L61, directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No
Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
FORM: FTA 06-21 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with )5A NCAC 02T, the Minimum Design Criteria for the Permitting of Punill Stations
and For cc Mains (latest version 1. and the GraviI% Sewer Minim um Design Criteria (latest version I as applicable?
® Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Anoroval of the reuuest will be issued
2. Professional Engineer's Certification:
I, Kathryn Espinoza, PE , attest that this application for RiverLights Conventional 5&6 MOD
(Professional Engineer's name from Application Item In. I.) (Project Name from Application Item It- 1)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Design Criteria for Gravit�_Sewers flalest version), and the Minimum Design Criteria. tor_the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application
information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
1, j6(F ,attestthatthisapplicationfor �wcRLGPhS GQ. l?". ) a L.dA91fILA-o6M
(Signature Authority Name from Application Item 1.3) (Project Name from Application Item H.1)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE — In accordance with General Statutes 143 215.0 and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature:_ \IrAA /A Date:
FORM: FTA 06-21 / I I — Page 5 of 5
X, CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
❑ Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
2. Professional Engineer's Certification:
I, _Bradford Sedgwick , attest that this application for _Masonboro Lodge
(Professional Engineer's time from Application Item III.1.) (Project Name from Application Item 11.1)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Desipn Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application
information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
I, Earl M. Worsley, Jr attest that this application for _L I) Masonboro Lodge (Signature Authority Name from Application Item I.3.)
(Project Name from Application Item I
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature: �� 51e Date: Ad 22IZ)
FORM: FTA 06-21 Page 5 of 5
i i Mk i,m of Water V. ,- ,,:. .
State of North Carolina
Department of Environmental Quality
Division of Water Resources
Flow Tracking for Sewer Extension Applications
(FTSE 10-18)
Entity Requesting Allocation: NNP IV - Cape Fear River, LLC
Project Name for which flow is being requested: RiverLights Conventional Ph. 5 & 6
More than one FTSE maybe required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: M'Kean Maffitt (Southside) WWTP
b. WWTP Facility Permit #: NPDES NC 0023973
All flows are itt MGD
c. WWTP facility's permitted flow 12.000
d. Estimated obligated flow not yet tributary to the WWTP 2.944
e. WWTP facility's actual avg. flow 8.044
f. Total flow for this specific request 0.011880
g. Total actual and obligated flows to the facility 11.000
h. Percent of permitted flow used 91.7
1I. Complete this section for each pump station you are responsible for along the route of this proposed
wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C) (D)=($+C) (E)=(A-D)
Design
Average
Approx.
Obligated,
Pump
Pump
Daily
Current
Not Yet Total Current
Station
Station
Firm Flow**
Avg. Daily
Tributary Flow Plus
(Name or
Permit
Capacity, * (Firm / pf),
Flow,
Daily Flow, Obligated Available
Number)
No.
MGD MGD
MGD
MGD Flow Capacity***
122 WQ0038060 1.462 0.419 0.000 0.484 0.484 -0.065
* The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow
that can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor
(pi) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the W WTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): Cape Fear Public Utility Authority
Downstream Permit Number:
Page 1 of 6
FTSE 10-18
III. Certification Statement:
I Jeff Theberge, CFPUA Eng. Mgr certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving
wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity
related sanitary sewer overflows or overburden any downstream pump station en route to the receiving
treatment plant under normal circumstances, given the implementation of the planned improvements
identified in the planning assessment where applicable. This analysis has been performed in accordance
with local established policies and procedures using the best available data. This certification applies to
those items listed above in Sections I and II plus all attached planning assessment addendums for which I
am the responsible party. Signature of this form certifies that the receiving collection system or treatment
works has adequate capacity to transport and treat the proposed new wastewater.
of Signing Official
Page 2 of 6
FTSE 10-18
PLANNING ASSESSMENT ADDENDUM (PAA)
Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is <
0.
Pump Station (Name or Number):
Given that:
a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for
100 % and 0.484 MGD of the Available Capacity (E) in Pump Station
122 ; and that
b. The rate of activation of this obligated, not yet tributary capacity is currently approximately
N/A MGD per year; and that
c. A funded Capital Project that will provide the required planned capacity, namely
PS 122 Upgrades is in design or under construction with
planned completion in 2022 ; and/or
d. The following applies:
There is a funded and active construction project completing the installation of RiverLights
Pump Station 2, in addition to the necessary upgrades at Pump Station 122. These upgrades
will serve full build out of both sewer shed basins.
Therefore:
Given reasonably expected conditions and planning information, there is sufficient justification to allow
this flow to be permitted, without a significant likelihood of over -allocating capacity in the system
infrastructure.
I understand that this does not relieve the collection system owner from complying with G.S. 143-
215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal
system.
Page 3 of 6
FTSE 10-18
AMR lm�mm! OF
'Irv�f\�i.".�•�•i !,{ �Y1�4`�{I �i �Y��7!i%l, .�i�iNf �. _�i�'.� �/!/Jk.'T� ��
I
RIVER LIGHTS DEVELOPMENT
CONVENTIONAL PHASE 5 & 6
NEW HANOVER COUNTY, NC
FAST TRACK APPLICATION NARRATIVE
Prepared for:
NNP IV -CAPE FEAR RIVER, LLC
3410 River Road, Suite 103
Wilmington, NC 28412
Prepared by:
vMCMM&CR=.
243 North Front Street
Wilmington, NC 28401
(910)343-1048
Project 92735-0250 (40)
Modified: December 22, 2021
FTA Narrative
RiverLights Development
Conventional Phase 5 & 6 - Modification
Wilmington, New Hanover County
December 2021
NNP IV — Cape Fear River, LLC is proposing to develop a 1,329.4 acre tract of land along River
Road. Conventional Phase 5 & 6 received a permit on 10/26/2021 to construct 327 single family
units within the development. The nature of this FTA submittal is to permit a modification to
the existing permit for an additional 33 units and subsequent sanitary sewer linework
associated with this addition. The proposed public system will consist of gravity sewer to
service the proposed development.
NNP IV — Cape Fear River, LLC will install the gravity sewer. The Cape Fear Public Utility
Authority (CFPUA) will own and maintain the system as well as accept the sewer flow
(additional 11,880 GPD) from the subdivision into Pump Station 1 (PSI). PSI will convey flows
to the Barnards Creek Pump Station (owned and operated by CFPUA) which ultimately
conveys flow to the M'Kean Maffitt Southside Wastewater Treatment Plant. PSI (WQ0038060) is
located to the south of the Conventional Phase 1 subdivision. Flows will be gravity fed into PSI
and will be pumped out through a series of 8" and 12" force mains.
8" PVC gravity sewer will be installed throughout the proposed Conventional Phase 5 & 6
project, which will provide public sewer access for the a total of 360 residential units (327 units +
33 additional units = 360 total residential units). PSI is also designed to handle additional flows
from previously permitted and future development.
This new gravity system is designed in accordance with the NCDENR minimum design criteria.
Appropriate horizontal and vertical clearances will be provided when proximal to the proposed
storm drainage system and the proposed water system. The gravity sewer will be certified in
accordance with state regulations and the permit conditions.
S:\2735\0250\40-Permit\44-Applications for Utility Services\DEQ\2021-12-02_Sf-6 TH Lots - Modification\Sanitary Sewer
Narrative (SF 6 Modification).doc