Loading...
HomeMy WebLinkAboutNCG030293_2021 DMR_20211110SHIELD ENGINEERING October 5, 2021 Rick Mirecki CIRCOR Pumps North America LLC 1710 Airport Road Monroe, North Carolina 28110 Subject: Monthly Stormwater Sampling — September 2021 Certificate of Coverage No. NCG030293 CIRCOR Pumping Technologies — Monroe, NC Shield Project No. 1150109-17 Dear Mr. Mirecki: Shield Engineering, Inc. (Shield) successfully collected a monthly storrnwater sample for Stormwater Discharge Outfall (SDO) #004 at the CIRCOR Pumps North America LLC — Monroe facility on September 21, 2021. The pH was measured at 6.4 at SDO #004 and the total event precipitation was 0.12 inches. In addition to the collection of samples, Shield performed Qualitative Monitoring at SDO #004. Shield has prepared the Stormwater Discharge Monitoring Report (DMR) using the results of analyses from the commercial laboratory that the CIRCOR facility has contracted with, and the field values indicated above. The sampling results from the September 215` event show that CIRCOR has an exceedance of Copper at Outfall #004. CIRCOR remains in Tier Three for Copper and Zinc at SDO 4004. Shield greatly appreciates the opportunity to provide environmental services to CIRCOR. If you have any questions in reference to this document or require further information, please feel free to contact the undersigned at (704) 394-6913. Respectfully, SHtEL ENGINEERING, INC. Magdaline Tzannis Senior Project Manager MeU�@�4 Seniogineer Robert L. Griffin, PE President/CEO Attachments: DMR — September 2021, Pace Analytical Report, Qualitative Monitoring Reports 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0293 Person Collecting Samples: TJ Gladden Facility Name: Circor Pumping Technologies Laboratory Name: Pace Analytical Facility County: Union Laboratory Cert. No.: 329 Discharge during this period: U Yes Lj No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ✓ Yes No If so, which Tier (I, ll, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR L Yes Lj No Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall004 Outfall005 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 9/21/2021 NA 46529 24-Hour Rainfall in inches 0.12 C0530 TSS in mg/L (100 or 50*) 96.3 pH in standard units (6.0 — 9.0 FW, 00400 6.8-8.5 SW) 6.4 Copper, total recoverable In mg/L 01119 (0.010 FW, 0.0058 SW 0.0118 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) <5,0 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.076 Chemical Oxygen Demand (COD) in 00340 mg/L(120) <25.0 00552 Non -Polar Oil & Grease in mg/L (15) <12.5 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): Exceedance of Copper at SDO #004, "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." //// 0 /,�)- Signature of Permittee or Delegated Authorized Individual Date Email Addrese Phone Number