January 13, 2021
MEMBERS OF
NATIONAL SOCIETY OF
PROFESSIONAL ENGINEERS
AMERICAN CONGRESS OF
SURVEYING AND MAPPING
Subject: Fast Track Application For the Childress Winery LLC located at 1000 Childress Vineyard Road.
This is the second submittal for this project.
References: 1. Application letter dated 01/10/22 for Fast Track Permit Form SFTA 06-21. Please
disregard the letter dated 01/10/22. It is being replaced by this one dated 01/13/22.
2 Marked up Davidson County GIS photo showing the new sewer line and various buildings
at Childress Winery LLC at 1000 Childress Vineyard Road.
3. Company representative for Childress Winery LLC is Steve Hartzog (336-460-2976).
4. The WWTF Permit Number for pipe placed in 2004 is NC0055786 for City of Lexington
Waste Water Facility.
5. Childres"s Winery LLC is registered to do business in NC. See number 0644898 dated
09/10/2002. See Attachments.
6. Letter designating Steve Hartzog as representative. See attachment.
7. NCGS map showing location.
8. Second Fast Track Permit Form SFTA 06-21.
9. Zoom meeting for this project on Friday 01/07/22 to discuss this project. Attendees
included Jennie Graznak of NCDEQ, Alex Lowe of NCDEQ, Roger Jones of City of
Lexington, Steve Hartzog of RCR, and Randall Kale of Kale Engineering.
10. Meeting at restaurant and winery to walk over site and examine the waste water facilities.
Attendees included Roger Jones of the City of Lexington, Steve Hartzog of RCR, and
Randall G. Kale of Kale Engineering.
11. Fast Track Application FTA 06-21 dated 01/13/22.
This letter serves as the revised cover letter for the subject application for the new sewer line to be
constructed at the Childress Winery LLC located at 1000 Childress Vineyard Road. Please note that this
letter will replace the reference 1 letter and a new narrative is given below.
This project will consist of constructing 1500'+- of new 4" and 6" Schedule 40 Core Foam Pipe to take
waste water from the san sewer lift station at the winery to the Swearing Creek Outfall. This new pipe is
being installed to eliminate the need for the pump station. This new pipe being placed will be gravity flow
only to Swearing Creek Outfall. Waste water will continue to flow into the pump station, but will not be
pumped out. It will exit the pump station by gravity flow to the Swearing Creek Outfall. This outfall goes
to City of Lexington Waste Water Facility. See the reference 2 marked up GIS Photo. This is an
economic decision based on the cost of maintaining the pump station.
The existing 8" pipe, which was constructed in 2004 will continue to receive waste water from the
restaurant which is gravity flow only. Currently some of the waste water going into the 8" line comes from
the pump station and some of it is gravity flow from the restaurant. Therefore the flow in the existing 8"
pipe will be lessened, but it will not become a "dry pipe". It will continue to be used with the lesser flow.
The new 4" gravity pipe leaving the pump station will service only one building. It was permitted by the
City of Lexington and will be used as it has been placed recently. The new 6" pipe being installed will be
KALE ENGINEERING
3550 Vest Mill Road
WINSTON SALEM, N.C. 27103
PROPERTY SURVEYS
CONSTRUCTION SURVEYS
DESIGN OF ROADS AND STREETS
WATER AND SEWAGE SYSTEMS 336-768-0250
SUBDIVISION PLANNING & LAYOUT email kaleengr@bellsouth..net
MEMBERS OF
NATIONAL SOCIETY OF
PROFESSIONAL ENGINEERS
AMERICAN CONGRESS OF
SURVEYING AND MAPPING
permitted by NCDEQ as noted in the above referenced items. This application letter is to be used for the
application process for the 6" line for NCDEQ.
The amount of waste water being permitted and shown on the reference 4 form is 0. No new buildings are
being constructed and the total existing amount of waste water has already been approved. The total
amount of waste water was approved for the 2004 construction of the 8" line and the amount of waste water
is not being increased.
This new 4" line was permitted by the Davidson County plumbing department and is already under
construction. Thus far 75' +- of 4" line and 125'+- of 6" line has already been installed. This new pipe
was connected to the invert (lowest point) inside the existing pump station with the invert of the new 4"
pipe matching the invert of the lowest pipe that empties into the pump station. The waste water will gravity
flow out from the invert of the pump station. The pump station will remain in place, but it will not be used
to pump the wastewater. The waste water that drains into the pump station will drain out only. The pump
station will no longer be used to pump the waste water.
The end of the new 6" pipe is located 200'+- from the lift station and the invert elevation of the new pipe is
2' lower than the invert of the lift station and 6'+- below the surface of the ground. The line is also located
12'+- West of the centerline of the existing gravel driveway leaving the lift station and going Northward
from the lift station. The new line placed thus far has been placed on 1/8" per foot, which is 1%.
The Reference 11 Fast Track Application has been revised as requested to my best knowledge. Please note
that the waste water being added to the system is 0. However Kale Engineering did add the quantities and
the percentages of waste water that were approved in 2003 and 2004 for the previous project. These
numbers were included for informational purposes only and will not increase the amount of total waste
water approved for this system.
I hope this helps explain this project. If you have any questions, please do not hesitate to call me at 336-
768-0250. We are always glad to hear from you.
Randall G. Kale
Kale Engineering
336-768-0250
Division of Water Resources
State of North Carolina
Department of Environmental Quality
Division of Water Resources
FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 06-21 & SUPPORTING DOCUMENTATION
Application Number: (to be completed by DWR)
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Childress Winery LLC (company, municipality, HOA, utility, etc.)
2. Applicant type: 0 Individual 0 Corporation 0 General Partnership 0 Privately -Owned Public Utility
0 Federal ❑ State/County 0 Municipal X Other
3. Signature authority's name: Steve Hartzog per 15A NCAC 02T .0106(b)
Title: Company Representative
4. Applicant's mailing address: PO Box 398
City: Welcome State: NC Zip: 27374-0398
5. Applicant's contact information:
Phone number: (336) 460-2976 Email Address: shartzognarcrracing.com
II. PROJECT INFORMATION:
1. Project name: Childress Winery
2. Application/Project status: x Proposed (New Permit) Existing Permit/Project
If a modification, provide the existing permit number: WQ00 and issued date:
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of a master plan, provide the existing permit number: W000
3. County where project is located: Davidson
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.84301° Longitude: -80..28310°
5. Parcel ID (if applicable): 6719-04-845329 (or Parcel ID to closest downstream sewer)
ILL CONSULTANT INFORMATLON:
1. Professional Engineer: Randall G. Kale License Number: 10748
Firm: Kale Engineering P.0
Mailing address: 3550 Vest Mill Road
City: Winston Salem State: NC Zip: 27103-
Phone number: (336)768 -0250 Email Address: kaleengr®bellsouth.net
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: City of Lexington Waste Water Facility Permit Number: NC0055786
Owner Name: City of Lexington
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s): WQCS00042
2. Downstream (Receiving) Sewer Information: 15 inch X Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCSCS00042
Owner Name(s): City of Lexington
FORM: FTA 06-21
Page 1 of 5
GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
['Yes ❑ No X N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑ No X N/A
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and
supplementary documentation as required by 15A NCAC 02T.01 I5(c) been attached?
❑ Yes 0 No X N/A
4. Origin of wastewater: (check all that apply):
❑ Residential (Individually Owned)
❑ Residential (Leased)
❑ School / preschool / day care
X Food and drink facilities
❑ Businesses / offices / factories
0 Retail (stores, centers, malls)
❑ Retail with food preparation/service
❑ Medical / dental / veterinary facilities
❑ Church
❑ Nursing Home
❑ Car Wash
X Hotel and/or Motels
❑ Swimming Pool/Clubhouse
❑ Swimming Pool/Filter Backwash
X Other (Explain in Attachment)
Winery
5. Nature of wastewater: % Domestic % Commercial %Industrial (See 15A NCAC 02T .0103(20))
If Industrial, is there a Pretreatment Program in effect? 0 Yes 0 No
6. Has a flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ❑ No
➢ If yes, provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(0)
Daily Design Flow a,b
No. of Units
Flow
winery
625 gal/day
1
625 GPD
Winery processing
1,000 gal/day
1
1,000 GPD
Hotel
9,600 gal/day
1
9,600 GPD
Restaurant
1,200 gaVday
1
1,200 GPD
gal/
GPD
gal/
GPD
Total
GPD
a See 15A NCAC 02T .0114(b) (d) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use
areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals
as defined in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for estabhshments not identified [in table 15A NCAC 02T.0114] shall
be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114)
> Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
❑ Flow has already been allocated in Permit Number: NC0055786 Issuance Date: 10/22/03
X Rehabilitation or replacement of existing sewers with no new flow expected
❑ Other (Explain):
FORM: FTA 06-21
Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
I. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
6
1425
PVCC
> Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
> Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: . ° Longitude: -
3. Total number of pumps at the pump station:
3. Design flow of the pump station: millions gallons per day (firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify)
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B):
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
> Include documentation that the portable source is owned or contracted by the applicant and is compatible with the
station.
FORM: FTA 06-21 Page 3 of 5
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations'
storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be
provided as part of this permit application in the case of a multiple station power outage.
FORM: FTA 06-21 Page 4 of 5
SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)?
15A NCAC 02T.0305(fl contains minimum separations that shall be provided for sewer systems:
x Yes ❑ No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
18 inches
2Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
2Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HOW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**My other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
10 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
> Ifnoncompliance with 02T.0305(f) or (Q), see Section X.1 of this application
*15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpage
2. Does this project comply with the minimum separation requirements for water mains? x Yes ❑ No ❑ N/A
> If no, please refer to 15A NCAC I8C.0906(f) for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands? x Yes ❑ No ❑ N/A
> Please provide supplementary information identifying the areas of non-conformance.
> See the Division's draft separation requirements for situations where separation cannot be met.
> No variance is required if the alternative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: x No
If yes, does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200? ❑ Yes 0 No
> This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes x No
or 401 Water Quality Certifications?
> Please provide the permit number/permitting status in the cover letter if coverage/authorization is required.
6. Does project comply with I5A NCAC 02T.0I05(c)(6) (additional permits/certifications)? x Yes 0 No
Per 15A NCAC 02T.0105(c)(6) directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" Yes x No
Per 15A NCAC 02T.0402 "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
> If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
FORM: FTA 06-21 Page 5 of 5
CERTIFICATIONS:
1. Does the submitted system comply Vvith 1 5A NCAC 02T the Minimum Design Criteria for the Permitting of Pumu Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
❑ Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
concurrently with the approval of the permit. and projects requiring a variance approval may be subject to longer
review times. For projects requiring two or more variances or where the variance is determined by the Division to be
a significant portion of the project, the full technical review is required.
2. Professional Engineer's Certification:
I, CR(it 0 CIQ I I (� - Kde_ attest that this application for Ch 4 Ctve..SS ,/17 h e' `/
(Professional Engineer's name from Application Item In.1.) (Projec Name from Application Rent II. I)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain
portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this
material and have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the
application information, including failure to disclose any design non-compliance with the applicable Rules and design
criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
176.743 , attest that this application for GA i I Cl N e S s w i Nt e v y
A / L
(Signature Authority Naz tom Application Item I.3.) (Project Name from Application Item Ilk)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the
Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this
application package are not completed and that if all required supporting information and attachments are not included, this
application package will be returned to me as incomplete.
NOTE — In accordance with General Statutes I43-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Date: !- I3 - ZZ,
FORM: FTA 06-21 Page 6 of 5