Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0041731_Application (FTSE)_20220111
Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Wadesboro (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: David Edwards per 1 SA NCAC 02T .0106(b) Title: Town Manager 4. Applicant's mailing address: 124 E. Wade Street City: Wadesboro State: NC Zip: 28170- 5. Applicant's contact information: Phone number: (704) 694-5171 Email Address: WadesboromanaQer a,windstream.net II. PROJECT INFORMATION: 1. Project name: Wadesboro Industrial Park 2. Application/Project status: ❑ Other ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0041731 and issued date: June 9, 2020 If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Anson 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.988635' Longitude:-80.067355' 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Mark Lacy License Number: 036286 Firm: LKC Engineering Mailing address: 140 Aqua Shed et City: Aberdeen State: NC Zip: 28315-_ ![f I 0 '021 2 k,0 LKC ENGINEERING, PLLC PO Box 888 Aberdeen, NC '.28315 (910) 420-1437 PAY TO THE ORDEFI=OF Fidelity Bank FOR ' �_.t_2.0 _ . . f: DATE 8084 - 66-358/531 6'b COLLARS 0 Engineering EM Landscape Architecture Surveying r December 8, 2021 Mr. Trent Allen, PE NCDENR Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301 Re: Wadesboro Industrial Park Town of Wadesboro, Anson County Public Water Supply Systems Permit Modification Existing Permit No. WQ0041731 Mr. Allen, Regarding the above referenced project, please find enclosed: rtl.,CIVCLt OEQiavR DEC 1 0 2021 WOOS =AYETTR/i3 pp ;inNNN4! OFFICE 1. One Copy of the Fast Track Application Modification Package 2. One Copy of Existing Permit No. WQ0041731 3. One Project Layout Map 4. One USGS Project Map 5. One application fee check for $480.00 The proposed project will include the installation of approximately 865 If of 8-inch PVC gravity sewer, 190 If of 8-inch DIP gravity sewer, 2,205 If of 6-inch PVC force main, and a new sewer pump station. This modification includes downsizing the proposed 8-inch force main to a 6-inch force main, replacement of existing 6-inch gravity sewer on Liberty Street with approximately 575 If of 8-inch gravity sewer, and minor miscellaneous gravity sewer modifications around the industrial park site. The attached application does not include any flow because there will be no flow to the system initially and proposed use is unknown. Flow will be permitted prior to making any connections to the system. If you have any questions, please do not hesitate to contact me at (910) 420-1437 or by email at brandon@lkcengineering.com. Sincerely, LKC Engineering, PLLC baifizekkqz 40-bcd-eua- Brandon Lovelace, E.I. LKC Engineering, PLLC, 140 Aqua Shed Court, Aberdeen, North Carolina 28315 PH: 910/420-1437 * FAX: 910/637-0096 * License No. P-1095 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Town of Wadesboro (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: David Edwards per I5A NCAC 02T .0106(b) Title: Town Manager 4. Applicant's mailing address: 124 E. Wade Street City: Wadesboro State: NC Zip: 28170- 5. Applicant's contact information: Phone number: (704) 694-5171 Email Address: Wadesboromanager@windstream.net ❑ Privately -Owned Public Utility ❑ Other t*tivtu DEQ/DWR DEC I 0 2021 VVOROS FAYE1TEVQLE REGIONAL ©PUCE II. PROJECT INFORMATION: 1. Project name: Wadesboro Industrial Park 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0041731 and issued date: June 9, 2020 If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Anson 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.988635' Longitude: -80.067355' 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Mark Lacy License Number: 036286 Firm: LKC Engineering Mailing address: 140 Aqua Shed ct City: Aberdeen State: NC Phone number: (910) 420-1437 Zip: 28315-_ Email Address: mark n,Ikcengineering.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Anson County Regional WWTP Permit Number: NC0041408 Owner Name: Anson County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Town of Wadesboro FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes [No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories 5. Nature of wastewater : ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) % Domestic/Commercial % Commercial % Industrial (See I5A NCAC 02T .0103(20)) �Is there a Pretreatment Program in effect? 6. Has a flow reduction been approved under I5A NCAC 02T .0114(f)? ❑ Yes ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: ❑ Yes ❑ No ❑ No Establishment Type (see 02T.0114(f)) Daily Design Flow a.b No. of Units Flow Industrial gal/day GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Iota/ GPD a See 15A NCAC 02T .0114(b), (d), (e)(I) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I5A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: GPD (per ISA NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & NIDC (Gravity Sewers): I . Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 865 PVC 8 190 DIP > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: Pump Station 0+00 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.983739° Longitude:-80.068507' 3. Design flow of the pump station: 0.185 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 350 gallons per minute at 120 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6 2205 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(I ): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) i% 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ®Yes ❑No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webnage > If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 & Buffer Permitting Branch ❑ Yes ®No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per I5A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per I 5A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A I Eyes. include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 3. Applicant's Certification per 15A NCAC 02T .0106(b): David Edwards, Town Manager X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting_of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supportinE documents. 2. Professional Engineer's Certification: I, Mark A. Lacy P.E. attest that this application for (Professional Engineer's name from Application Item 1II.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. �t, vk0 i North Carolina Professional Engineer's seal, signature, and date: �� �( � ��•FESS%p�•9 14 s 62Q�' i x Y� t :,qRK A. 4P—ft00 itti Jz —Lvzl attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 2 FORM: FTA 04-16 Page 5 of 5 ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director David Edwards, Town Manager Town of Wadesboro 124 E. Wade Street Wadesboro, NC 28170 NORTH CAROLINA Environmental Quality June 9, 2020 Subject: Permit No. WQ0041731 Town of Wadesboro Wadesboro Industrial Park Wastewater Collection System Extension Permit Anson County Dear Mr. Edwards: rtUti V tLJ DEQ/DWR DEC 1 0 2021 WQROS CAYETTFVII, IF P P.N.;iV4 OFFICE In accordance with your application received June 8, 2020, we are forwarding herewith Permit No. WQ0041731 dated June 9, 2020 to Town of Wadesboro for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition II.1: This permit shall not be automatically transferable; a request must be made and approved. Condition II.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system- wide collection system permit issued to the Permittee. It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. ODE Depart. nl of Environmental goal\ie.*/ North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1225 Green Street, Suite 714 I Fayetteville, North Carolina 28301 910.433.3300 Town of Wadesboro Permit No. WQ0041731 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Stephanie Zorio at (910) 433-3322 or via e-mail at stephanie.zorio@ncdenr.gov. Sincerely, ,-DocuSignedd by: "-5189C2D3DD5C42B... Trent Allen, Regional Supervisor Water Quality Regional Operations Section Fayetteville Regional Office Division of Water Resources, NCDEQ cc: Mark Lacy, LKC Engineering, 140 Aqua Shed Ct., Aberdeen, NC 28315 Laserfiche File Page 2 of 9 STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Wadesboro Anson County for the construction and operation of approximately 590 linear feet of 8-inch gravity sewer and 2,200 linear feet of 8-inch force main and a 350 GPM @ 120 TDH pump station with a permanent generator w/ATs to serve the Wadesboro Industrial Park project, and the discharge of 0 gallons per day of collected domestic wastewater into the Anson County Regional Wastewater Treatment Plant existing sewerage system, pursuant to the application received June 8, 2020, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. —DocuSiggnnedd by: _ Tren'A11 ;°feral Supervisor Division of Water Resources, NCDEQ By Authority of The Environmental Management Commission Permit Number: WQ0041731 Permit Issued: June 9, 2020 Page 3 of 9 Downsizing of Proposed 8-inch Forcemain to 6-inch Forcemain ARBOR MARSHALL ° SALEM 2 -� tm bps rn Upsizing Existing 6-inch Gravity Sewer to 8-inch Gravity Sewer Increasing Downstream Capacity LKC ENGINEERING, PLLC WADESBORO INDUSTRIAL PARK AERIAL MAP 0 250 500 1,000 Feet /4/ Proposed 8-inch Gravity Sewer ps Legend Proposed Pump Station "/ Proposed 6-inch Force Main Downsizing of Proposed 8-inch Forcemain to 6-inch Forcemain Upsizing Existing 6-inch Gravity Sewer to 8-inch Gravity Sewer Increasing Downstream Capacity r LKC ENGINEERING, PLLC WADESBORO INDUSTRIAL PARK AERIAL MAP Legend PSI Proposed Pump Station /� 0 250 500 1,000 / Proposed 6-inch Force Main Feet "/ Proposed 8-inch Gravity Sewer