Loading...
HomeMy WebLinkAboutSW4210901_Plansheet - Misc. Detail_20220105KIMMER TOP ET IE BAFFLES WITH METAL ROPE RTO REST SKIMMER CLASS B STONE T-POST, WOVEN WIRE (4'X4'X1') FABRIC BACKING AND COIR [FIBER NETTING PROTECT WEIR (SEE SHEET 1 of:W WITH FILTER FILTER FABRIC 0 FABRIC 111 25%215 LL 25% 25% Tfi HIHifil V` BAFFLES yffiffi=ff_5'x3'x18" AT 25% BOTTOM 6" STONE APRON WITHul BASIN LENGTH FILTER FABRIC LENGTH NOTES: SKIMMER BASIN CROSS SECTION -EARTH BERM SHALL BE STABILIZED w/SEEDING ACCORDING TO PLAN SPECIFICATIONS. TOP OF DAM /-LINE WEIR WITH FILTER FABRIC TOP OFDAM WEIR ffl LENGTH -111-111 II II -111 - - DITCH AND B URY FILTER TIM FABRIC EDGE (MIN. 12" OF ll FABRIC) ffl ffl 111111111111 ffl ffl ffl M Ilk �/ WEIR CROSS SECTION MAINTENANCE • INSPECT TEMPORARY SKIMMER BASIN AND EMPTY SKIMMER OF ALL DEBRIS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL. REMOVE SEDIMENT AND RESTORE BASIN TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE BASIN. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL AREA. REPAIR BAFFLES. • CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUM OF 1.5 FEET BELOW THE LOW POINT OFTHE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT TO SUGHTLYABOVE DESIGN GRAD E.STABI LIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE BASIN IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING AND MATTING, AS NEEDED. STANDARD TEMPORARY SKIMMER BASIN SHEET I OF 2 -SCALE: NTS GENERAL EROSION CONTROL NOTES: 1. SEE EROSION CONTROL SHEETS FOR SKIMMER BASIN DIMENSIONS 2. DAM HEIGHT MAXIMUM OF 5'FROM ORIGINAL GROUND SURFACE. 3. SOIL STABILIZATION FABRIC REQUIRED FOR EMERGENCY SPILLWAY. INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH LAMINATED PLASTIC OR IMPERMEABLE GEOTEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ONE PIECE, NOTJOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS. SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTION(S) SHOULD OVERLAP THE LOWER SECTION(S) SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. COIR FIBER BAFFLE SPECIFICATIONS FOR SKIMMER BASINS Construction MATERIALS Spe7SO cifications I . I I matting made of 100% coconut fiber (coin) twine woven into high Strength matrix with the properties shown in Table 6.65a. 2. Staples should be made of 0.125 inch diameter new stool wire formed into a `U' shape not less than 12 inches in length with a throat of I inch in width. The staples anchor the porous baffles into the sides and bottom of the basin. 3. Ensure that stool posts for porous baffles are of a sufficient height to support baffles at desired height. Posts should be approximately 1-31S" wide measured parallel to the fence. and have a minimum weight of 1.25 lb/linear ft. The posts must be equipped with an anchor plalt-, having a minimum area of 14.0 square inches and be of the self -fastener angle steel type to have a means of retaining wire and coix fiber mat in the desired position without displacement. 4. Use 9-gauge high tension wire for support wire. Table 6.65a Specifications for Porous Baffle Material Coir Fiber Baffle Material Prooertv Reauirements____� 0 0 z M M Z M C0 .0 x Cn Z --i x > C > _06 00 0 > 0 > M Z _n C) 7) > Cal z 111340. 0 y 2" WEEP WEEP HOLES PLAN F #4 BAR Z TOP ELEVATION 6 SECTION X_x - 6" 1 7 SEE NOTE OF BOX & PIPE NOTE: YARD INLET/CATCH BASIN TO BE OPEN ON ALL FOUR SIDES AND HAVE MANHOLE LID IN TOP BAFFLES WITH METAL T-POST, WOVEN WIRE FABRIC BACKING AN COIR FIBER NETTING SEE BAFFLE BOTTOM DETAIL (THIS ANCHORE SHEET) E E T�)� WITH STAPLES SKIMMER DEWATERING DEVICE WITH RETRIEVAL ROPE TOP OF DAM 5'-0"' ANCHORE HORE HILL 1, WITH TH STAPLES LES DEVICE E RETRIEVAL ROPE FILTER FABRIC LINED WEIR RIPRAP STONE ENERGY DISSIPATER 4'X4'X1'CLASS B STONE UNDER SKIMMER ROPE WITH STAKE PERSPECTIVE VIEW NOTES: 1. DRIVE STEEL FENCE POST AT LEAST 18 INCHES INTO SOLID GROUND. 2. WOOD POST ARE NOT ACCEPTABLE. 3. DIRECT WATER TO TOP OF BASIN USING STABILIZED DITCH, SLOPE DRAIN PIPE OR OTHER APPROVED METHOD. SPACE BAFFLES 25% OF BASIN BOTTOM LENGTH BAFFLE DETAIL CORR FIBER MATTING - SECURE WITH NYLON ZIP TIES. ZIP FLOWDON ST WOVEN WIRE FABRIC.-/ SECURE WITH NYLON TT 1 1 11 ZIP TIES. Eft T-POSI- SHEET 2 OF STANDARD TEMPORARY SKIMMER BASIN SCALE:NTS2 NOTES: 1. SKIMMER IS TO BE A SURFACE DEWATERING DEVICE. FAIRCLOTH SKIMMER SPECIFIED. 2. SKIMMER SHOULD RISE TO LEVEL OF WEIR HEIGHT IN TEMPORARY BASIN OR TO RISER INLET. 3. ROPE ATTACHED TO SKIMMER TO HELP KEEP CLEAN. RIG OUTLET END: CONNECTII TO OUTLET PIPE OR RISE NOT INCLUDED WITH SKIMMER SUPPLIED BY USER. STANDARD SKIMMER DETAIL SCALE:NTS NOTE: SKIMMER TO BE MANUFACTURED BY FAIRCLOTH SKIMMER. THE SKIMMER AND ORFICE ARE SIZED ACCORDING TO FAIRCLOTH SKIMMER SIZING CALCULATOR THAT CAN BE FOUND AT HT-FPS://FAIRCLOTHSKIMMER.COM/SKIMMER-SIZING/. SIZING IS SHOWN ON TEMPORARY SKIMMER BASIN CHART PROVIDED IN THE PLANS. PROPERTY OWNER TO ENSURE THAT NPDES STORMWATER LOGS Top Bank Zone 2 'One Managed Zone 2 Stream Undisturbed Vegetation Managed Zone 1 Natural No Impervious Vegetation Undisturbed Vegetation Area No Impervious Natural Area Vegetation 30' 20' Centerline Stream 20' 30' TYPICAL STREAM BUFFER CROSS-SECTION NOTES: USE CLASS "B" CONCRETE THROUGHOUT. U) PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. < OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT < 12" CENTERS AS DIRECTED BY THE ENGINEER. M 0 0 USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. UL _j CL 1­4 z IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB 0 0 in AS SHOWN ON STD. NO. 840.00. < I= :z 3- LU LL < FOR 8'-0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER I-_ 0 O0 8'-0' TO 16'-0" IN HEIGHT USE 8" WALLS AND BOTTOM SLAB. ADJUST cc < QUANTITIES ACCORDINGLY. �- = Z LU CO I-- LL 0 _j CONSTRUCT WITH PIPE CROWNS MATCHING. x 0 1­4 < 0 CO INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A > POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. CL CHAMFER ALL EXPOSED CORNERS 1". LU 0 DRAWING NOT TO SCALE. INCREASE THE SIZE OF THE 6" OPENING TO 8" MAX., AS DIRECTED BY THE ENGINEER BY ADDING 2" TO THE WALL HIEGHT ABOVE THE TOP ELEVATION. ADJUST QUANTITIES ACCORDINGLY. z 1-4 U) Cal cc TOP SLAB dJ 0 GUTTER LINE U_ 1 " 0 #4 BAR Z 6"' 0 1-- 2'- -4 LU 4- 3 TOP ELEVATION VATION Cr ---- 7-111'2" CLR, 0 9C 10 0 0 00 PIPE WALL 01 1 CC I(THICKNESS VARIES � < (MIN.) a: 1 z #4 BAR Z < Z I CO LU SECTION Y-Y PART SECTION Y-Y 0E-4 SHOWING DETAILS AT OPENING _j LU 0 l.- z MIN. DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN (BASED ON MIN. HEIGHT, H) Uj LU REINFORCING ITOP & BOT. SLAB CU. YDS. CONC. TOTAL QUANTITIES DEDUCTION DED. ONE I= 6" THROAT BARS - X I BARS - Y I BA DIMENSIONS IN BOX BOX & SLABS ONE 1 0 0. Z IPENING LENGTH I NO.1 LENGTH 1 0 TOP SLAB 1307. 8LABIWALL/Fr. UIG. REINF.1 YD' (MIN III) C.S.C. S. R.C.R. C. YD' z T LENGTH 3'-0" 1 6 1 4'-3" 2 4'-3" 3'- 3 0.015 0.032 2.24 4'- 6 0.181 1 0.271 1 0.250 27 1 1.046 "1 1 1 W-O" 1 A I A' -a" 1 9 a7 I i inn n nga n nnR n nea0 0.053 0.059 SHEET 1 OF 2 0.066 0.066 840.04 3 i" MIN. T OPE TEMPORARY SWALE CHART, IKERNODLE LANDING SUBDIVISION PHASE 2 SWALE UPSTREAM SWALE AREA (AC.) AREA TOTAL (AC) COMPOSITE C CX1 Q(CFS) TOTAL CL(CFS) SLOPE (%) LEFT SLOPE RIGHT SLOPE TYPE LINER N FLOW DEPTH (FT) ACTUAL DEPTH (FT) TOP(TOP(FT)T(PSF) VELOCITY (FT/SEC) BOTTOMWIDTH (FT) LINING STAPLE PATTERN 17 - 0.05 0.05 0.4 2.20 0.09 0.09 1.50 31 4:1 TRI N/A 0.020 0.14 1.50 10.5 1.31 0.13 N/A N/A N/A 18 19 0.56 0.92 0.4 2.20 0.99 1.62 1.50 3:1 4:1 TRI TEMP 0.053 0.57 1.50 10.5 1.43 0.53 N/A NAG S75 OR EQUAL D 24 - 0.11 0.11 0.4 2.20 0.24 0.24 4.00 31 4:1 TRI N/A 0.037 0.18 1.50 10.5 1.61 0.22 N/A N/A N/A 25 0.10 0.10 0.4 2.20 0.22 0.22 5.30 3:1 4:1 TRI N/A 0.036 0.17 1.50 10.5 1.77 0.26 N/A N/A N/A 26 0.16 0.16 0.4 2.20 0.35 0.35 5.25 31 4:1 TRI N/A 0.035 0.20 1.50 10.5 2.01 0.31 N/A N/A N/A 27 26 0.16 0.32 0.4 2.20 0.35 0.70 6.00 3:1 4:1 TRI TEMP 0.033 0.25 1.50 10.5 2.62 0.92 N/A NAG S75 OR EQUAL D 28 27 1.07 1.39 0.4 2.20 2.35 3.06 4.00 3:1 4:1 TRI N/A 0.033 0.46 1.50 10.5 3.10 1.15 N/A NAG S75 OR EQUAL D 29 0.14 0.14 0.4 2.20 0.30 0.31 4.00 4:1 3:1 TRI N/A 0.045 0.24 1.50 10.5 1.54 0.60 N/A 32 33 OA4 0.29 0.4 2.20 0.30 1 0.63 6.10 4:1 3:1 TRI 1 TEMP 0.034 0.24 1.50 10.5 2.56 0.90 N/A NAG 575 OR EQUAL D 33 0,15 0.15 0A 2,20 0.33 0.33 5.25 4:1 3:1 TRI N/A 0.035 0.20 1.50 105 101 031 N/A N/A N/A 34 0.04 0.04 0.4 2.20 0.09 0.09 5.30 4:1 3:1 TRI N/A 0.037 OA2 1.50 10.5 1A1 020 N/A N/A N/A 35 18 0.37 1.29 0.4 2.20 0.81 2.84 3.40 4:1 3:1 TRI TEMP 0.033 0.46 1.50 10.5 3.03 0.98 N/A NAG S75 OR EQUAL D 36 - 0.15 0.15 0.4 2.20 0.33 0.33 1.50 4:1 3:1 TRI N/A 0.040 0.26 1.50 10.5 1.13 0.11 N/A N/A N/A 37 0.09 0.09 0.4 2.20 0.19 0.19 2.00 4:1 3:1 TRI N/A 0.040 0.20 1.50 10.5 1.10 0.12 N/A N/A N/A 38 0.06 0.06 0.4 2.20 0.12 0.12 1.00 4:1 3:1 TRI N/A O,044 0.20 1.50 10.5 0.72 0.06 N/A N/A NJA 39 0.07 0.07 0.4 2.20 0.15 0.15 1.50 3:1 4:1 TRI N/A 0.041 0.19 1.50 10.5 0.90 0.09 N/A N/A N/A 40 0.05 0.05 0.4 2.20 0.11 0.11 1.00 3:1 4:1 TRI N/A 0.044 0.19 1.50 10.5 0.69 0.06 N/A N/A N/A 41 0.10 0.10 0.4 2.20 0.21 0.21 2.00 3:1 4:1 TRI N/A 0.040 0.21 1.50 10.5 1.14 0.12 N/A N/A N/A 42 0.19 0.19 0.4 2.20 0.41 0.41 1.50 3:1 4:1 TRI N/A O,039 0.28 1.50 10.5 1.21 0.13 N/A N/A N/A 43 0.55 0.55 0.4 2.20 1.21 1.21 3.75 4:1 3:1 TRI N/A 0.034 0.36 1.50 10.5 2.65 0.94 N/A NAG S75OREQUAL D 44 6.04 6.04 0.4 2.20 13.29 13.29 2.00 3:1 3:1 TRI N/A 0.032 1.04 1.50 9.0 4.10 1.30 N/A NAG S75 OR EQUAL D 45 0.30 0.30 0.4 2.20 066 0.66 100 3.1 3.1 TRI N/A 0.040 1 1.50 9.0 127 0.26 N/A N/A N/A 46 0.12 0.12 1 0.4 1 0.26 ()!26 -7 .50 3:1 11 TRI 1 N/A O�040 0.27 1 1.50 9. 0 1!17 0!2 5 N/A N/A NJA 47 4.90 4.90 1 0.4 1 2.20 1 10.78 110.78 1.50 3 1 1 3:1 TRI I N/A 0.033 1.03 I 1-.so 9.0 1 3.12 0.96 WA NAG 57; OR EQUAL I = 5.5 1 N/HR (2-YR STORM) TEMPORARY IT NER = NORTH AMERICAN GREEN OR EQUAL C=0.40 TRI =TRIANGULAR TRAP =TRAPE701DAL (WITH BOTTOM WIDTH) PERMANENT SWALE CHART, KERNODLE LANDING SUBDIVISION PH2 SWALE UPSTREAM SWALE AREA (AC.) AREA TOTAL (AC) COMPOSITE C CX1 Q (CFS) TOTAL CKCFS) SLOPE LEFT SLOPE RIGHT SLOPE TYPE LINER N FLOWACTUAL DEPTH FT DEPTH (FT) TOP(F­U VELOCITY (FT/SEC) T (P SF) BOTTOMWIDTH (FT) REMARKS 17 - 0.05 0.05 0.4 2.79 0.14 0.14 1.50 3:1 4:1 TRI N/A 0.045 0.22 1.50 10.5 0.83 0.19 N/A 18 19 0.56 0.92 0.4 2.79 1.56 2.56 1.50 3:1 4:1 TRI N/A 0.040 0.61 1.50 10.5 1.97 0.52 N/A 24 0.11 0.11 0.4 2.79 0.31 0.31 4.00 3:1 4:1 TRI N/A 0.045 0.24 1.50 10.5 1.54 0.60 N/A 25 0.10 010 0A 2.79 0.28 0.28 5.30 3:1 4:1 TRI N/A 0.045 0.22 1.50 10.5 1.65 033 N/A 26 0.16 0.16 0.4 2.79 044 044 525 31 4:1 TRI N/A 0.045 0.26 1.50 10.5 1.86 0.85 N/A 27 26 0.16 0.32 0A 2.79 0.45 0.89 6.00 3:1 4:1 TRI N/A 0.045 0.33 1.50 10.5 2.34 1.24 N/A 28 27 1.07 1.39 0.4 2.79 298 388 400 11 4:1 TRI N/A 0.040 0.59 1.50 10.5 3.18 1.47 N/A 29 0.14 0A4 0A 2.79 0.38 0,39 4.00 4:1 3:1 TRI N/A 0.045 0.26 1.50 10.5 1.65 0.65 N/A 32 33 0.14 1 0.29 0.4 1 2.79 0.38 1 0.80 6.10 4:1 1 3:1 TRI N/A 0.045 1 0.32 1.50 1 10.5 2.23 1 1.22 N/A 33 - 0.15 0.15 0.4 2.79 0.42 0.42 5.25 4:1 1 3:1 TRI N/A 0.045 0.26 1.50 10.5 1.78 0.85 N/A 34 - 0.04 0.04 0.4 2.79 0.12 0.12 5.30 4:1 3:1 TRI N/A 0.045 0.16 1.50 10.5 1.34 0.53 N/A 35 18 0.37 1.29 0.4 2.79 1.03 3.60 3.40 4:1 3:1 TRI N/A 0.040 0.60 1.50 10.5 2.86 1.27 N/A 36 - 0.15 0.15 0.4 2.79 0.41 0.41 1.50 4:1 3:1 TRI N/A 0.045 0.32 1.50 10.5 1.14 0.30 N/A 37 0.09 0.09 0.4 2.79 0.24 0.24 2.00 4:1 3:1 TRI N/A 0.045 0.25 1.50 10.5 1.10 0.31 N/A 38 0.06 0.06 0.4 2.79 0.16 0.16 1.00 4:1 3:1 TRI N/A 0.045 0.25 1.50 10.5 0.73 0.16 N/A 39 0.07 0.07 0.4 2.79 0.19 0.19 1.50 3:1 4:1 TRI N/A 0.045 0.24 1.50 10.5 0.94 0.22 N/A 40 0.05 0.05 0.4 2.79 0.15 0.15 1.00 3:1 4:1 TRI N/A 0.045 0.24 1.50 10.5 0.74 0.1.5 N/A 41 0.10 0.10 0.4 2.79 0.27 0.27 2.00 3:1 4:1 TRI N/A 0.045 0.26 1.50 10.5 1.14 0.32 N/A 42 0.19 0.19 0.4 2.79 0.52 0.52 1.50 3:1 4:1 TRI N/A 0.045 0.35 1.50 10.5 1.21 0.33 N/A 43 0.55 0.55 0.4 279 153 153 375 4:1 3:1 TRI N/A 0.045 0.41 1.50 10.5 2.09 0.96 N/A 44 6.04 6.04 0.4 2.79 16.84 16.84 2.00 3:1 3:1 TRI N/A 0.030 1.11 1.50 9.0 4.56 1.39 N/A 45 0.30 0.30 0.4 2.79 0.84 0.84 1.00 3:1 3:1 TRI NJA 0.045 0.48 1.50 9.0 1.22 0.30 N/A 46 0.12 0.12 0.4 2.79 0.33 0.33 1.50 3:1 3:1 TRI 045 0.32 1.50 9.0 1.07 0.30 N/A 47 4.90 4.90 0.4 2.79 13 13.66 1.50 . 3:1 3:1 TRI 1.09 1.50 9.0 3.83 1.02 N/A 1 =6.97 I N/HR (10-YR STORM) TRI =TRIANGULAR C=0.40 TRAP =TRAPEZOIDAL (WITH BOTTOM WIDTH) TEMPORARY SKIMMER BASIN CHART, KERNODLE LANDING PHASE 2 REQUIRED REQUIRED SURFACE TOTAL TOTAL COMPOSITE 10-YEAR TOP TOP DEPTH SIDE SEDIMENT VOLUME SURFACE AREA EM EIRGENCY SKIMMER ORIFICE DEWATERING BASIN# DRAINAGE DISTURBED C-VALUE INTENSIT Q,,(CIFS) LENGTH WIDTH (FT) SLOPES VOLUME PROVIDED AREA (SQ PROVIDED WEIR LENGTH SIZE(IN.) (IN.) TIME(DAYS) AREA (AC) AREA (AC) Y (I NIHR) (FT) (FT) (H:V) (CU FT) (FT) (CU FT) FT) (SQ FT) 8 6.65 2.27 0.40 5.57 14.82 100 50 2.00 2:1 4086 8864 4817 5000 15', 0.5'Flow 2.0 1.75 3.07 9 4.94 1.74 0.40 5.57 11.01 90 40 2.00 2:1 3132 6224 3578 3600 15', 0.5'Flow 2.0 1.50 2.93 10 1.50 0.44 0.40 5.57 3.34 50 25 2.00 2:1 792 1964 1086 1250 5', 0.5'Flow 2.0 0.75 370 NOTE: YARD INLET/CATCH BASIN TO BE OPEN ON ALL FOUR SIDES AND HAVE MANHOLE LID IN TOP 1 1x2 CILR. -W C) aCl) Or y 0 LLI IlIt"Cl-R. 1112 #3 BARS "X" 1 It EQUALLY SPACED CLR. F PLAN PRECAST OR CAST IN PLACE TOP SLAB F #4 BARS "Y" qF HANDLE I,- 1 PIPE SLEEVE #3 BARS 4" EQUALLY SPACED 11/2' CLR. SECTION V-V G #4 11B�t" CLR.- EQUALLYI SPACED Ilt" CILR. - #3 BARS SECTION W-W - 11 -AD. 3" X 1/4" THICK OUND OR SQUARE LIT WASHER 2 HEX NUT COUNTERSINK PART WHERE HANDLE IS LOCATED 1" AND ALLOW HANDLE TO MOVE VERTICALLY. I % 1 PIPE SLEEVE X 3" LONG. PART SECTION THRU COVER SHOWING HANDLE #4 BAR NL 6 j- DOWEL Al 04J E 00 0 4� 1:11 00 U bb " =) C r., 0 LU 0 U r-4 r,4 C: U O 0 C: Z b.0 0 4� a) I > 0 N .- 1�0 Q) (o (n M (n Ma) r-, c: < C: C: U) (3) D U) C: C. 0 MU C: L.0 L/) N ±f L Cli 0 = 4­0 > 0 1-- < 2 Of U j 0 ILL Z Of 0 LU 0 LU U Lu W 0 C) LU - F2 Uj (D >< W o 1-- LU LU z CC 0 Lu 0 < LU z z 0 z U j D Uj J z 0 0 z U Uj z �Id _j LU LU o U LU 0� z 0< < un U V) < M 2 0 U I-- < 0 00 < _j -2- : Z = U LQ Lu Z 0 0 0 Cr 1-- a- V) U 1-- 0 0 LU LU V) I-_ LD z z z LU U') Z LU 2 LU 2 F- x (D (D 0 LLI < z < z _j - < < 2 < 2 1-- 0 0 Z z U z = I.- LU < LU < 0 06 LU LU M oo Cr_ U Z LU I-- LU C:) ­i rJ ­i rJ < 00 rf) rJ Lr) 0 -_ C:) ­i C:) d Z DRAWN BY: JAS CHECKED BY: ARS DATE: 10/14/2020 PROJECT NO.: 302.19 REF. NO.: SCALE: NO SCALE 1111111i"'I", "0100CAR 0\0 C10 10 OF 1