HomeMy WebLinkAbout330065_Inspection_20211117Facility Number
Division of Water Resources
0 Division of Soil and Water Conservation
0 Other Agency
Type of Visit: f/i Compliance Inspection • Operation Review 0 Structure Evaluation 0 Technical Assistance
Reason for Visit: (► Routine 0 Com ' taint 0 Follow-up 0 Referral 0 Emera enc) 0 Other 0 Denied Access
Date of Visit: _ I I J I} Arrival Time:
Farm Name: r, n
Owner Name:
Departure Time:
Mailing Address:
Physical Address:
Facility Contact:
Owner Email:
Phone:
County: Region()
Onsite Representative:
Certified Operator:
Back-up Operator:
Location of Farm:
Title:
Latitude:
Integrator:
Phone:
Certification Number:
Certification Number:
Longitude:
Swine
Design Current
Capacity Pop.
Wean to Finish
Wean to Feeder
Feeder to Finish
Fan -ow to Wean
Fan -ow to Feeder
Farrow to Finish
eAk
Gilts
Boars
Other
Design Current
Wet Poultry Capacity Pop.
Layer
Non -Layer
D Poult
Design Current
Ca s aci Po
Cattle
Design Current
Capacity Pop.
Dairy Cow
Dairy Calf
Dairy Heifer
Dry Cow
Non -Dairy
Beef Stocker
Beef Feeder
Beef Brood Cow
Discharges and Stream Impacts
I. Is any discharge observed from any part of the operation?
Discharge originated at: ❑ Structure D Application Field ❑ Other:
a. Was the conveyance man-made?
b. Did the discharge reach waters of the State? (If yes, notify DWR)
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does the discharge bypass the waste management system? (If yes, notify DWR)
2. Is there evidence of a past discharge from any part of the operation?
3. Were there any observable adverse impacts or potential adverse impacts to the waters
of the State other than from a discharge?
❑ Yes ZliNo ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
❑ Yes VI No ❑ NA ❑ NE
❑ Yes 21Islo ❑ NA El NE
5/12/2020 Continued
Page I of 3
`Date of Inspection: / //J i I p1
Waste Collection & Treatment
4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate?
a. If yes, is waste level into the structural freeboard?
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in):
❑ Yes ErNo ❑ NA ❑ NE
❑ Yes ❑ No ❑ NA ❑ NE
Structure I Structure 2 Structure 3 Structure 4 Structure 5 Structure 6
5. Are there any immediate threats to the integrity of any of the structures observed?
(i.e., large trees, severe erosion, seepage, etc.)
6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes IZINo ❑ NA ❑ NE
waste management or closure plan?
If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR
❑Yes ErNo ❑NA ONE
7. Do any of the structures need maintenance or improvement? ❑ Yes I 1'10 ❑ NA ❑ NE
8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes ErNo ❑ NA ❑ NE
(not applicable to roofed pits, dry stacks, and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require ❑ Yes No ❑ NA ❑ NE
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes 'No ❑ NA ❑ NE
maintenance or improvement?
11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes zf No 0 NA 0 NE
❑ Excessive Ponding 0 Hydraulic Overload ❑ Frozen Ground 0 Heavy Metals (Cu, Zn, etc.)
❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus El Failure to Incorporate Manure/Sludge into Bare Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area
12. Crop Type(s):
13. Soil Type(s):
14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes 12rNo 0 NA ❑ NE
15. Does the receiving crop and/or land application site need improvement? ❑ Yes 2 No ❑ NA ❑ NE
16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes E2" 'o ❑ NA 0 NE
acres determination?
17. Does the facility lack adequate acreage for land application? ❑ Yes 0 No ❑ NA 0 NE
18. Is there a lack of properly operating waste application equipment? ❑ Yes 0 No ❑ NA 0 NE
Required Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes 121r No 0 NA ❑ NE
20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes [/'No 0 NA 0 NE
the appropriate box.
❑WUP El Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑Other:
21. Does record keeping need improvement? If yes, check the appropriate box below. Yes ❑ No 0 NA ❑ NE
Waste Application Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code
,i Rainfall Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey
22. Did the facility fail to install and maintain a rain gauge? ❑ Yes [% No 0 NA ❑ NE
23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes I7No ❑ NA 0 NE
Page 2 of 3 5/12/2020 Continues
'Facility Number: J 3 - [p�
'Date of Inspection:
24. Did the facility fail to calibrate waste application equipment as required by the permit?
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check
the appropriate box(es) below.
❑ Failure to complete annual sludge survey
❑ Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
❑ Yes No El NA ❑NE
❑ Yes 2No El NA ❑NE
['Failure to develop a POA for sludge levels
26. Did the facility fail to provide documentation of an actively certified operator in charge?
27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification?
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern?
If yes, contact a regional Air Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the
permit? (i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below.
❑ Yes 112rNo ❑ NA
❑ Yes 2rNo [] NA
❑ Yes 2rNo El NA
❑ Yes No El NA
❑ Yes ❑ No ❑ NA
El Yes pNo El NA
El Application Field ❑ Lagoon/Storage Pond El Other:
32. Were any additional problems noted which cause non-compliance of the permit or CAWMP?
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
34. Does the facility require a follow-up visit by the same agency?
❑ Yes
❑ Yes
❑ Yes
2 No
' No
No
❑ NA
❑ NA
❑ NA
❑ NE
❑ NE
❑ NE
❑ NE
❑ NE
❑ NE
❑ NE
❑ NE
❑ NE
Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments.
Use drawings of facilit to better explain situations (use additional pages as necessa )
ekk.6.-#,ktetfcr - r 7al o 15 g&rn _
1, (a a C) q 1)1 1l o -;-
Ci as a p ^ I . i 1o?o, �oc-er
toooe-i93- z-/0--I 1,11
'1444±t r; -- S 1 9 C 3 �ed-to 1. -- Akt j 6'i t w .
Ptc l�C ` .� ) \ c r± ,
A-9 d (-4-€7\ ,n-- 4 1),.
11/A - - cx,LA e i:L C,N-0( , -a2 a_41- 3
'PST I \0i1 0) D) CJ
IA C —
Reviewer/Inspector Name:
Reviewer/Inspector Signature:
Page 3 of 3
ZC11v 3e car.CL
com
Phone: 9i
Tr! -;
Date: pi
5/12/2020