Loading...
HomeMy WebLinkAboutWQ0002520_NOV-2020-LM-0055_20200602ROY COOPER Covmwr MICHAEL S. REGAN Secretary S. DANIEL SMITH fxreetor James G Latham, Jr Town of Bath PO Drawer 6a Bath, NC 27808 SUBJECT: NOTICE OF VIOLATION NORTH CAROLINA Environmental Qualfty June 1, 2020 Tracking Number: NOV-2020-LM-0055 Permit No. WQ0002520 Town of Bath WWTP Beaufort County Dear Mr. Latham: A review of the February 2020 Non -Discharge Monitoring Report (NDMR) for the subject facility revealed the violation(s) indicated below: Limit Exceedance Violation(s): Sample Limit Reported Location Parameter Date Value Value Type of Violation 002 BOD, 5-Day (20 Deg. Q 2/20/2020 15 22 Daily Maximum Exceeded (00310) 002 Nitrogen, Ammonia Total (as 2/20/2020 6 30.04 Daily Maximum Exceeded N) (00610) 002 Solids, Total Suspended 2/20/2020 10 14 Daily Maximum Exceeded (00530) 002 BOD, 5-Day (20 Deg. Q 2/28/2020 15 17 Daily Maximum Exceeded (00310) 002 Nitrogen, Ammonia Total (as 2/28/2020 6 11.28 Daily Maximum Exceeded N) (00610) NorthCaro linaDepart mentofEoviroamentalQuality I Dins-:•_fV-'star Resources Washington Regional Office 1943 Washington Square Ma;' IV, asr 5t3n. North Csro'irts 27339 ° 257-946-4F481 Limit Exceedance Violation(s): Sample Limit Reported Location Parameter Date Value Value Type of Violation 002 BOD, 5-Day (20 Deg. C) 2/29/2020 10 19.5 Monthly Average Exceeded (00310) 002 Nitrogen, Ammonia Total (as 2/29/2020 4 20.66 Monthly Average Exceeded N) (00610) 002 Solids, Total Suspended 2/29/2020 5 11.9 Monthly Average Exceeded (00530) Monitoring Violation(s): Sample Monitoring Location Parameter Date Frequency Type of Violation 002 pH (00400) 2/1/2020 5 X week Frequency Violation 002 pH (00400) 2/8/2020 5 X week Frequency Violation 002 pH (00400) 2/15/2020 5 X week Frequency Violation 002 pH (00400) 2/22/2020 5 X week Frequency Violation 002 pH (00400) 2/29/2020 5 X week Frequency Violation Reporting Violation(s): Sample Location Parameter Date Type of Violation 002 Chlorine, Total Residual (50060) 2/29/2020 Parameter Missing Remedial actions, if not already implemented, should be taken to correct any noted problems. The Division of Water Resources may pursue enforcement actions for this and any additional violations. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent (SOC). North Caro rs Department of Erv:ror. msnts 'qua ty I D v.sor. of Water Faso4rces Wash rgton Raflona-Offce 1943 Wask rflton Swsre his:: I Wash'r.gtor, North %sro :ra 27589 ems, 252 *4 —64B 1 If you have any questions concerning this matter or to apply for an SOC, please contact Will Hart of the Washington Regional Office at 252-948-3968. Sincerely, ROW TOW." Robert Tankard, Assistant Regional Supervisor Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ cc: LaserFiche NorthCaro linaDepart mentofEoviranmentalQualrty I QiwsianofWater Resources Washington Regional Office 1 943 Washington Square Ma;' I Washington, North Csrwirts 27339 �`� ° 257-946-4F481