HomeMy WebLinkAboutNC0047759_Compliance Evaluation Inspection_20220106DocuSign Envelope ID: 313CE61D134-5739-495E-91374-1 DA7EC916735 t�. STATE q, ROY COOPER��� > Governor O ELIZABETH S. BISER Secretary S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality January 05, 2022 Alton C Cuthrell Pruitthealth-Sea Level LLC 468 Hwy 70 E Sealevel, NC 28577 SUBJECT: Compliance Inspection Report PruittHealth at Sealevel WWTP NPDES WW Permit No. NCO047759 Carteret County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the PruittHealth at Sealevel WWTP on 12/16/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0047759. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". Please respond in writing to this office within 30 calendar days of your receipt of this letter regarding your plans or measures to be taken to address the following issues: 1. Install a bar screen, as mentioned within the permit; 2. Remove landscaping debris to enable access to the discharge pipe and outfall; 3. Perform actions to repair or provide plan to address corrosion of tank(s); 4. Install additional handrails along elevated catwalk of treatment system; 5. Repair the visual alarm at the influent pump station; and, 6. Submit permit renewal application to Raleigh by 1/31/2022. Additional details and information regarding each of the items listed above is provided on the attached inspection report. D_E Q�� North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 910.796,7215 DocuSign Envelope ID: 313CE61D134-5739-495E-91374-1 DA7EC916735 If you should have any questions, please do not hesitate to contact Bryan Lievre with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at bryan.lievre@ncdenr.gov. Attachment Cc: Patricia Davis (via email) Laserfiche Sincerely, EW DocuSigned by: Vt Ua, Sad GIA�41" E3ABA14AC7DC434... Morella Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ D_E Q�� North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 910.796,7215 DocuSign Envelope ID: 3BCE6DB4-5739-495E-9B74-1 DA7EC916735 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCO047759 111 121 21/12/16 I17 18 LC] I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I 1166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 10:OOAM 21/12/16 17/08/01 PruittHealth at Sealevel WWTP 468 US Hwy 70 E Exit Time/Date Permit Expiration Date Sealevel NC 28577 11:30AM 21/12/16 22/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Patricia Taylor Davis/ORC/252-466-6787/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Alton C Cuthrell,468 Hwy 70 E Sealevel NC 28577/Maintenance Director/252-225-0112/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: Bryan Lievre DWR/WIRO WQ/910-796-7215/ 1/5/2022 El�,2r2ccr� 1_1 v-~4249ABED37443E... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Morella Sanchez -King DWR/WIRO WQ/910-796-7218/ DocuSigned by: 1/6/2022 F1446"Lua S —b EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. �-EMBAMAc7Dc434... Page# DocuSign Envelope ID: 313CE61DI34-5739-495E-91374-1 DA7EC916735 NPDES yr/mo/day Inspection Type (Cont.) NCO047759 I11 12I 21/12/16 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A routine compliance inspection of the Pruitt Health at Sea Level Wastewater Treatment Plant (WWTP), was performed on December 16, 2021. The purpose of the inspection was to verify that the facility is operating in compliance with the conditions and limitations specified within Permit NC0047759. Patricia Davis, contract operator in responsible charge (ORC), was present during the inspection. According to the current permit which was issued 7/7/2017, became effective 8/1/2017 and expires 7/31/2022, the wastewater treatment and closed loop recycle facility consists of: - An influent pump station; - A manual bar screen; - An equalization basin with aerated flow; - A flow splitter box; - Dual package plants (for a total flow of 0.014 MGD) extended aeration units with: o Extended air -activated sludge basins; o Clarifiers; o Aerobic digesters; - Dual tertiary filters; - Chlorine contact basin with liquid chlorine equipment; - Liquid sodium bisulfite dechlorination equipment; - A flow measuring device; - A clearwell; and, - A mudwell. A review of monitoring records since the last inspection performed on 2/1/2017, indicate that the system has had violations of daily exceedances of BOD5 or enterococci on 7/2/2018, 9/10/2018, 6/10/2019, 11/12/2019, 3/16/2020, 7/6/2020, 7/20/2020 and 7/12/2021. It should be noted that with the exception of the samples obtained in 7/2020, all other subsequent sampling events resulted in results below daily maximums and below monthly average limits. Daily exceedances were attributed to required chlorine and bisulfite adjustments as well as possible temperature and other demand changes within the wastewater. The following items are recommended to be corrected or addressed for the facility (with some of these items having been mentioned within the 2/1/2017 inspection report): 1. A bar screen should be installed as mentioned within the permit. These structures are highly recommended to be installed in order to keep solids out of the equalization basins. If the system does not feel as though the structure is warranted, a request should be made to eliminate this structure from the permit. A hanging basket -type was previously indicated as being purchased; however, a review of our files does not indicate that our office was ever contacted to inform us that the structure was installed — despite our prior request. 2. Landscaping debris has been stockpiled within the access path to the discharge outfall. The path to the outfall needs to be cleared and maintained in order to check the line for breaks and maintain the line, as needed, as well as to ensure that the outfall does not contain floating solids or foam (per conditions of the permit). 3. Corrosion of the metal tank which encompasses the equalization/filter/mudwell/clearwell was observed. Tank refurbishing or a plan maintain this structure is needed to prevent system failure and increase life expectancy of the structure. 4. Handrails were missing from the alongside the elevated catwalk on the bridge between the tertiary tank and the aerator tank. The lack of handrails on this elevated structure could place a person in imminent danger of death or serious bodily injury and should be corrected immediately. 5. The visual alarm at the influent pump station needs to be repaired. The lightbulb was replaced during the inspection, so additional activities will be required to be performed to assess and repair this item. 6. Please remember that a renewal application should be submitted 6 months prior to the expiration Page# DocuSign Envelope ID: 3BCE6DB4-5739-495E-9B74-1 DA7EC916735 Permit: NCO047759 Owner -Facility: PruittHealth at Sealevel WWTP Inspection Date: 12/16/2021 Inspection Type: Compliance Evaluation of the existing permit (i.e. by 1/31/2022). Ms. Davis was very knowledgeable of the facility and the facility seemed to be well maintained although constant upkeep is required to deal with corrosive conditions. Records were reviewed and found to be detailed, well organized and complete. The facility is compliant with the discharge Permit NC0047759. Please review the comment sections of the inspection report for more details. Page# DocuSign Envelope ID: 3BCE6DB4-5739-495E-9B74-1 DA7EC916735 Permit: NCO047759 Owner -Facility: PruittHealth at Sealevel WWTP Inspection Date: 12/16/2021 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? ❑ 0 ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The current permit was issued 7/7/2017, became effective 8/1/2017 and expires 7/31/2022. The owner is reminded to submit a renewal application six months prior to the permit expiration date (i.e. by 1/31/2022). As previously mentioned within the last inspection report, the facility does not have a bar screen. Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ Comment: The influent pump station is located approximately 450 feet southeast of the treatment system and approximately 90 feet outhwest of the generators behind the main building. High level alarms are present at the pump station and within the maintenance room on the main building. Although the audible alarm sounded at the pump station, the visual alarm did not illuminate. The lightbulb was repalced during the inspection, but this did not rectifv the Droblem so additional measures will be reauired to reDair the alarm. Q- c,..-- Type of bar screen Yes No NA NE a.Manual ❑ b.Mechanical ❑ Are the bars adequately screening debris? ❑ ❑ ■ ❑ Is the screen free of excessive debris? ❑ ❑ 0 ❑ Is disposal of screening in compliance? ❑ ❑ 0 ❑ Is the unit in good condition? ❑ ❑ 0 ❑ Comment: Bar screens should be installed to prevent solids from clogging the treatment system components Page# 4 DocuSign Envelope ID: 3BCE6DB4-5739-495E-9B74-1 DA7EC916735 Permit: NC0047759 Inspection Date: 12/16/2021 Owner -Facility: PruittHealth at Sealevel WWTP Inspection Type: Compliance Evaluation Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate? Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ Comment: High liquid levels alarms are present at the WWTP and in the maintenance room in the main building. Visual and audible alarms at the WWTP were functioning during the inspection. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment: Sludge is pumped from the system 1 - 2 times per year by Craven Ag Services. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Yes No NA NE Ext. Air Diffused ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ Page# 5 DocuSign Envelope ID: 313CE61DI34-5739-495E-91374-1 DA7EC916735 Permit: NCO047759 Inspection Date: 12/16/2021 Aeration Basins Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/1) Owner -Facility: PruittHealth at Sealevel WWTP Inspection Type: Compliance Evaluation Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment: As mentioned, the facility is operate at DO levels of 5-6 mg/L as the system reportedly operates poorly at below 3 ma/L. One of the trains continues to be used as a storage vessel due to low flow. Trains continue to be rotated every fall and spring. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? IY-Tvki[•7►/_90I:1 • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ Comment: The system is equipped with a Siemens Hvdroranqer 200 flow meter which is located within an effluent flume. The meter was last callibrated on 1/14/2021 by Chadwick Instrument Service Co. The system is permitted for 14,000 pals/day, had an average daily flow of -2,865 pals/day for 2020 and -2,323 pals/day for 2021 (1/20 through 11/20) with -1,900 pals/day for 11/2020. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Yes No NA NE ❑ ❑ N ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ Comment: Only grab samples are required to be obtained by the permit. Grab samples are obtained from the effluent of the flume which also contains the flow meter. Effluent was noted to have been clear and free of solids during the inspection. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ 0 ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ❑ Comment: The effluent pipe is reportedly submerged. As perviously mentioned, the system has dumped landscaping debris in the outfall access right-of-way. The path to the outfall needs to be cleared and maintained in order to verify that the outfall does not contain floating solids or foam (per conditions of the permit). Page# 6 DocuSign Envelope ID: 3BCE6DB4-5739-495E-9B74-1 DA7EC916735 Permit: NCO047759 Inspection Date: 12/16/2021 Owner -Facility: PruittHealth at Sealevel WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ Comment: ORC checks settleability durinq daily visits and measures sludqe weekly. ORC checks total residual chlorine, temperature and PH with Pruitt Health at Sea Level's Certification Number 5280. All other samples are sent to Environmentl 1 for analyses. Daily O&M log book and calibration records were viewed and found to have been well maintained. oraanized and comDlete. Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Comment: System has two backup generators which are both maintained by contract staff through corporate office. Page# 7