HomeMy WebLinkAboutNC0020656_Performance Annual Report 2008_20090129Annual Performance Report 2008 General Information Facility/System Name: City of Laurinburg Leith Creek Wastewater Plant Responsible Entity: City of Laurinburg Person In Charge/Contact: Robert A. Ellis, Treatment Plants Director Applicable Permit(s) NC0020656 / WQ002526 / WQCS00062 Description of Collection System The City of Laurinburg's collection system consists of 34 pump stations located throughout the system. There are 123.7 miles of gravity sewers and 24 miles of force mains. Our Leith Creek Plant consist of two types of treatment, one extended aeration plant, consisting of 2 aeration basins, 2 clarifiers, 2 chlorine contact chambers and one return sludge pump station with 3 pumps, total capacity 2.0 million gallons per day (MGD). The second plant is an oxidation ditch style with 1 clarifier, 1 chlorination point and 1 return sludge pump station with 3 dual speed pumps, total capacity 2.0 MGD, for a total treatment capacity of 4.0 MGD. The facility has 2 aerobic digesters, (1) 150,000-gallon tank and (1) 650,000-gallon tank with course air diffusers. Summary of System Performance for Calendar Year 2008 The discharge from the City of Laurinburg's Leith Creek Wastewater Treatment Plant was in non- compliance for the month of September 2008. Mogtiu NPDES Violation Reason(s) September Total Suspended Residual less than Excessive rainfall received 85% removal and excessive influent from Tropical Storm Hanna. flows. (4.037 MGD average) Summary of Sanitary Spills/Overflows: Months Location Volume 09/06/08 Bridge Creek Pump Station 24,000 Gallons 09/11/08 Manhole At 1005 Lila Drive 5,000 Gallons Summary of Sanitary Spills/Overflows (continued): Sanitary sewer overflow events in which volumes exceeding 1,000 gallons overflowed and reach surface waters are included in the monthly estimates and are shown separately as follows: Date Location Gallons Description Corrective Measures 09/06/08 Bridge Creek 24,000 Excessive Flow Continuing to perform smoke Pump Station Due to Tropical testing and visual inspections Storm Hanna. more frequently. 09/11/08 Lila Drive 5,000 Excessive Flow Continuing to perform smoke Manhole dueto Tropical testing and visual inspections Storm Hanna. more frequently. *Note the overflows listed resulted in no environmental impact. Notification This Annual Performance Report will appear on the City of Laurinburg's web site http://www.laurinburg.org and a statement on our Consumer Confidence Report (CCR) will inform citizens that the Annual Report is available via internet or upon request. Certification I certify under penalty of law that this report is complete and accurate to the best of my knowledge. I further certify that this •report has been made available to the users or customers of the named system and that those users have been notified of its availability. /Were,/ Robert A. Ellis, Treatment Plants Director Treatment Plants Director City of Laurinburg January 29, 2009