Loading...
HomeMy WebLinkAboutSW4210801_Supplement-EZ Form_20220105SUPPLEMENT-EZ COVER PAGE INFORMATION 1 Project Name 2 Project Area (ac) 3 Coastal Wetland Area (ac) 4 Surface Water Area (ac) -5 Is this project High or Low Density? 6 'Does this project use an off -site SCM? . Width of vegetated setbacks provided (feet) 8 Will the vegetated setback remain vegetated? 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)? � 10 Is streambank stabilization proposed on this project? 11 1Infiltration System _ 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter — 17 Rainwater Harvesting (RWH)- 18 Green Roof 19 Level Spreader -Filter Strip (LS-FS) 20 'Disconnected Impervious Surface (DIS) 21 Treatment Swale 22 Dry Pond _ 23 StormFilter 24 Silva Cell 25 Bayfilter 26 'Filterra FORMS LOADED 27 Name and Title: 28 Organization: 29 Street address: 30 City, State, Zip: 31 Phone number(s): 32 ',Email: unlf Caren __._._._ Q__-- ---.-.-_ Q__.- Low No 0 N/A No __... 0 0 — ----0- _.. --- 0 _--- 0 _ _0 0 _0.. 0 0 — 0 --- 0 Chad E. Abbott, PE C3 Design and Engineering, PLLC 537 East Lyon Station Road, Suite 102 Creedmoor, NC 27522 919-230-0996 chad@c3designeng.com Certification Statement I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. C A 0 ;a SEAL 4 Signature of Designer 10/z s Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LID 1 4 Type of SCM NA 5 Total drainage area (sq ft 1023201 6 Onsite drainage area (sq ft 1023201 7 Offsite drainage area (sq ft) 0 8 Total BUA in project (sq ft) 141052 sf 9 New BUA on subdivided lots (subject to permitting) (sq ft 108000 sf 10permitting) New BUA not on subdivided lots (subject to s 33052 sf 11 Offsite BUA (sq ft sf 12 Breakdown of new BUA not on subdivided lots: Parkin (sq ft 24000 sf Sidewalk (sq ft 1657 sf Roof (sq ft) 84000 sf Roadway s ft 31395 sf Future (sq ft) sf Other, please specify in the comment box below (sq ft sf 13 New infiltrating permeable pavement on subdivided lots (sq ft) sf 14 New infiltrating permeable pavement not on Isubdivided lots (sq ft sf 15permitting) Existing BUA that will remain (not subject to s ft sf 16 Existing BUA that is already permitted (sq ft 13816 sf 17 Existing BUA that will be removed (sq ft) 13816 sf 18 Percent BUA 13% 19 Design storm (inches) NA 20 Design volume of SCM cu ft NA 21 1 Calculation method for design volume NA ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): Property has two drainage area (DA), but summarized in one DA since the mafority of proposed impervious area are located in one specific DA. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 3 sf 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 4.23 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) N/A 8 Bottom width of curb outlet swale(s) (feet) N/A 9 Maximum side slope of curb outlet swale(s) (H:V) N/A 10 Minimum length of curb outlet swale(s) (feet) N/A 11 Are treatment swales used instead of curb outlet swales? Yes 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 lAre variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: N/A Swale 4 FDrainage Area ac BUA (ac) Pervious area ac C Q (cfs) Slope ( % ) Va„ow (fps) Va ua (fps) Flow depth (ft) 1 0.91 0.32 0.59 0.46 3.00 1.85 6.45 3.31 0.55 2 0.34 0.07 0.27 0.35 0.85 1.66 6.11 2.32 0.35 3 0.74 0.25 0.49 0.45 2.41 1.96 6.64 3.20 0.50 4 0.34 0.07 0.27 0.35 0.86 1.85 6.45 2.42 0.34 5 7.74 0.00 7.74 0.20 11.07 1.17 5.13 3.86 0.98 6 5.97 0.00 5.97 0.20 8.53 1.77 6.32 4.23 0.82 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30