HomeMy WebLinkAboutnc0039331_Compliance Evaluation Inspection_20220103ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Chris D. Blice, Chief Operations Officer Chatham County Schools PO BOX 128 Pittsboro, NC 27312 NORTH CAROLINA Environmental Quality January Yd, 2022 Subject: Compliance Evaluation Inspection NPDES Permit NCO039331 Facility Name: Bonlee Elementary School Chatham County Dear Mr. Blice: On December 17, 2021, Josh Brigham of the Raleigh Regional Office conducted a compliance evaluation inspection of the treatment facilities located at Bonlee Elementary School. The purpose of this inspection was to ensure compliance with the subject NPDES permit. During the inspection, the guidance of John Poteat was greatly appreciated. Bonlee Elementary School is located at 153 Bonlee School Road in Bonlee, North Carolina in Chatham County. The subject facility is covered under NPDES permit NCO039331. The subject facility is permitted to discharge wastewater into an unnamed tributary (UT) to Bear Creek, which is classified as Class C waters in the Cape Fear River Basin. This NPDES compliance evaluation inspection consisted of the following: • Review of the NPDES permit; • Review of the owner/facility information; • On -site review of records and logs; • On -site inspection of the wastewater treatment units; and • Inspection of the discharge. D. Q� North Carolina Department of Environmental Quality I Division of Water Resources z - d-ARaleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 noFmn v+ " -V 919.791.4200 Findings during the pre -inspection file review were as follows: 1. The current NPDES permit was issued effective April 1, 2017. The current permit expired October 31, 2021. Division records indicate that a permit renewal application was received on October 25, 2021. 2. A review'of Division records revealed that there are no overdue annual permit fees. 3. A review of the facility's DMR violation report since 2018 indicated the facility has had limit violations for BOD, Fecal Coliform, Ammonia, and TSS. There have also been monitoring violations for BOD, Fecal Coliform, Ammonia, TSS, and Temperature. There have also been two reporting violations. These violations have been addressed through separate correspondence. 4. The subject facility is classified as a Grade I Wastewater (WW-1). The designated Operator in Responsible Charge (ORC), John Poteat, and Backup ORC, Adam Pickett, are certified at WW-4 and WW-2 respectively. Findings during the inspection were as follows: 5. A review of onsite records was performed. DMRs and lab data are kept on site and no discrepancies were found after a cursory check of the August and September 2021 DMRs. Chain of custody forms were complete. The operators log was current and detailed. 6. Field parameters (pH, temperature, DO) are measured by the operator. All other parameters are measured by Meritech. 7. The facility treats wastewater utilizing the following treatment units: septic tank; 2 pump tanks; 2 micron filters; 4 pressure gauges; 2 recirculation tanks; 2 recirculating sand filters; flow meter; distribution box; and UV disinfection system. The observed treatment units were as described in the NPDES permit. 8. The high-water alarms within the effluent pump tanks were tested during the inspection. The audible alarm functioned when the floats were raised to create a false high-water level, but the visual alarm did not function. The ORC indicated the bulb needed to be replaced. Please ensure the light bulb is replaced. 9. The high-water alarms within the recirculating tanks were tested during the inspection. The audible alarm functioned when the floats were raised to create a false high-water level, but the visual alarm did not function. The ORC indicated the light bulb needed to be replaced and later sent in a picture of it functioning. 10. The inspector observed that both of the re -circulating sand filters were free of ponding, algae and excessive vegetation. 11. The ORC collects grab samples from a spigot that has been piped to collect treated effluent. 12. The effluent pipe was not discharging at the time of inspection and the stream was clear and free of any solids. If you have questions concerning this report please contact Josh Brigham at 919-791-4251 or j oshua.brigham(cr�,ncdenr. gov. Sincerely, Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ ATTACHNMNTs: EPA Water Compliance Inspection Report Cc: RRO Files Laserfiche qEQ5 North Carolina Department of Environmental Quality I Division of Water Resources ig Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 /"� 919.791.4200 United States Environmental Protection Agency Form Approved. EPA Washington, D.C.20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCO039331 I11 121 21/12/17 I17 18LCJ 191 S I 201 21111111111111111111111111111111111111111111 P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ------------- -------- Reserved ------------------ 67 70LI 71 I 72 ti i 73L_LJ74 71 I I I I I I I80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 08:30AM 21/12/17 17/04/01 Bonlee Elementary School 152 Bonlee School Rd Exit Time/Date Permit Expiration Date Bear Creek NC 27207 09:30AM 21/12/17 21/10/31 Name(s) of Onsite Representative (s)Mtles(s)/Phone and Fax Number(s) Other Facility Data /// John Thomas Poteat/ORC/919-412-7554/ Name, Address of Responsible Official/T-itle/Phone and Fax Number Contacted Chris D Blice,Chatham County Schools Pittsboro NC 27312//919-542-3626/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit E Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran E Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Joshua S Brigham DWR/RRO WQ/919-791-4200/ ,G? "') _._ I l 41 z o Z-4 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 1 31 NCO039331 I11 1 21/12/17 17 181„, Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) See attached inspection report. Page# 2 Permit: N00039331 Owner -Facility: Bon lee Elementary School Inspection Date: 12/17/2021 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ■ ❑ ❑ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ ■ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Comment: Upstream / Downstream Sampling Yes No NA NE Page# 3 Permit: NCO039331 Owner - Facility: Bonlee Elementary School Inspection Date: 12/17/2021 Inspection Type: Compliance Evaluation Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, ■ ❑ ❑ ❑ and sampling location)? Comment: No upstream flow. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? ■ ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 N ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ■ ❑ ❑ ❑ representative)? Comment: Grab samples stored on ice. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ■ ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 0 ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ■ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ M ❑ Comment: PH, DO and temp measured by ORC. Other parameters measured by Meritech Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? ❑ N ❑ ❑ Is septic tank pumped on a schedule? 0 ❑ ❑ ❑ Are pumps or syphons operating properly? 0 ❑ ❑ ❑ Page# 4 Permit: NCO039331 Owner - Facility: Bonlee Elementary School Inspection Date: 12/17/2021 Inspection Type: Compliance Evaluation Septic Tank Yes No NA NE Are high and low water alarms operating properly? ■ ❑ ❑ ❑ Comment: Visual alarm did not function. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ 0 ❑ Is the distribution box level and watertight? ■ ❑ ❑ ❑ Is sand filter free of ponding? ■ ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? ❑ ❑ ❑ ■ # Is the sand filter surface free of algae or excessive vegetation? ■ ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ ❑ ■ Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? ■ ❑ ❑ ❑ Are UV bulbs clean? 0 ❑ ❑ ❑ Is UV intensity adequate? ■ ❑ ❑ ❑ Is transmittance at or above designed level? ■ ❑ ❑ ❑ Is there a backup system on site? ❑ 0 ❑ ❑ Is effluent clear and free of solids? ■ ❑ ❑ ❑ Comment: Bulbs are cleaned weekl Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? ❑ ❑ ❑ Is the flow meter operational? ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: In -line house flow meter. ORC stated that it will be replaced in the next year. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ■ ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ■ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ■ ❑ Comment: No discharge observed Page# 5 Permit: NC0039331 Owner - Facility: Bonlee Elementary School Inspection Date: 12/17/2021 Inspection Type: Compliance Evaluation Effluent Pipe Yes No NA NE Page#