Loading...
HomeMy WebLinkAboutSW8990719_Historical File_20050801Transmittal Toe Paul Bartlett, DWQ Pane John K. Klein, PE CC: Ed Hill DatK 7/28/2005 Ma Trademark Comer Project No.: SW8 990719 Mod File No,: 25016 As per letter dated July 28, 2005, please find enclosed two (2) copies of the revised Drawing for the project. Revisions include: �q V 1. UVeir elevation has been added on the fbrebay wall detail. 2. The pond depth elevation has been corrected to 30.0 and excavation depth corrected on the pond detail. We trust this will satisfy your needs. Should there be any further questions, please feel free to contact our office. Thank you 3410 Wrightsville Avenue Wilmington NorthCandina 28403 910.799.7967 Fax 910.793.0599 P. 1 COMMUNICATION RESULT REPORT ( JUL.26.2OO5 5:O1PM ) TTI NCDENR WIRO FILE MODE OPTION ADDRESS (GROUP) RESULT PAGE 707 MEMORY TX 9-7930599 OK P. 3/3 REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional office Michael F. Easley, Governor FAX COVER SHEET Date., 7/26/05 To: John Klein Company: Wrightsville Eng. Services FAX #; (910) 793-0599 William G. Ross, Jr., Secretary No. of Pages; 3 (I ncl. Cover) From: Paul Bartlett Water Quality Section Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SWS 990719 Modification Project Name: Trademark Corner MESSAGE: John, A Request for Additional Information is attached for the subject project. The original will be mailed to Mr. Hill, and a copy will be mailed to you. //1 //**/" State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor FAX COVER SHEET Date: 7/26/05 To: John Klein Company: Wrightsville Eng. Services FAX #: (910) 793-0599 William G. Ross, Jr., Secretary No. of Pages: 3 (Incl. Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SW8 990719 Modification Project Name: Trademark Corner MESSAGE: John, A Request for Additional Information is attached for the subject project. The original will be mailed to Mr. Hill, and a copy will be mailed to you. ENB1ptb: S:IWQSISTORMWATERIADDINF0120051990719Mod.ju105 127 Cardinal Drive Extension, Wilmington, NC 28405-3845 Telephone (910) 796-7215 FAX (910) 350-2004 An Equal Opportunity Affirmative Action Employer Page 1 of 1 North Carolina Elaine F. Marshall � EFART ENT OF TVI:E Secretary E RET RY of T E: Corporations Corporations Home 19important Notice Corporate Forms/Fees ,'Corporations FAQ YTobacco Manufacturers ')Dissolution Reports =ONon-Profit Reports "Verify Certification Online Annual Reports Links A'Secretary Of State Home aRegister for E-Procurement aDept. of Revenue Legislation 01999 Senate Bills '>2001 Bill Summaries #'Annual Reports 1997 NCorporations 1997 eOther Legislation Search �=By Corporate Name jFor New Corporation WBy Registered Agent Online Orders Start An Order IDNew Payment Procedures Contact Us OCorporatiuns Division vSecretary of State's web site Print Printable Page PO Box 29622 Raleigh. NC 2i62"622 (919)807 03 Date: 7/26/2005 Click here to: View Document Filings I Print apre-populated Annual Report Form I File an Annual Report I Corporation Names Name Name Type NC Trademark Corners, Legal LLC Limited Liability Company Information SOSO: FID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address 0565390 Current -Active 9/27/2000 Domestic NC Perpetual Plage, Robert 807 Wood Cove Road Wilmington NC 28409 807 Wood Cove Road Wilmington NC 28409 2713 Trademark Drive Wilmington NC 28405 2713 Trademark Drive Wilmington NC 28405 For questions or comments about the North Carolina Secretary of State's web site, please send a -mail to Webmaster. http://www.secretary.state.nc.us/Corporations/Corp.aspx?Pitemld=5286698 7/26/2005 ybmu4 LIMITED LIABILITY COMPANY ANNUAL REPORT NAME OF LIMITED LIABILITY COMPANY: Trademark Corners, LLC STATE OF INCORPORATION: NC SOSID: 0565390 Date Filed: 3/31/2004 8:44 PM Elaine F. Marshall North Carolina Secretary of State SECRETARY OF STATE L.L.C. ID NUMBER: 0565390 FEDERAL EMPLOYER ID NUMBER: NATURE OF BUSINESS: None REGISTERED AGENT: Plage, Robert REGISTERED OFFICE MAILING ADDRESS: 807 Wood Cove Road Wilmington, NC 28409 REGISTERED OFFICE STREET ADDRESS: 807 Wood Cove Road Wilmington, NC 28409 County: New Hanover PRINCIPAL OFFICE TELEPHONE NUMBER: (910) 392-1500 PRINCIPAL OFFICE MAILING ADDRESS: 2713 Trademark Drive Wilmington, NC 28405 PRINCIPAL OFFICE STREET ADDRESS: 2713 Trademark Drive Wilmington, NC 28405 MANAGERSYMEMBER S/OR G ANI7_,ER S : Ed Hill Title: Manager 809 Wood Cove Rd. Wilmington, NC 28409 CERTIFICATION OF ANNUAL REPORT MUST BE COMPLETED BY ALL LIMITED LIABILITY COMPANIES Ed Hill FORM MUST BE SIGNED BY A MANAGER/MEMBER Ed Hill 3/31/2004 DATE Manager/Member TYPE OR PRINT NAME TYPE OR PRINT TITLE ANNUAL REPORT FEE: E-Paid Secretary of State • Corporations Division • Post Office Box 29525 • Raleigh, NC 27626-0525 OF WAIF Michael F. Easley, Governor � 9p �O G William G. Ross, Jr., Secretary co r North Carolina Department of Environment and Natural Resources + Alan W. Klimek, P.E. Director Division of Water Quality July 26, 2005 Mr. Broadus E. Hill, III, Managing Member Trademark Corners, LLC 807 Wood Cove Road Wilmington, NC 28409 Subject: Request for Additional Information Stormwater Project No. SW8 990719 Modification Trademark Corner New Hanover County Dear Mr. Hill: The Wilmington Regional Office received a Stormwater Management Permit Application for Trademark Corner on July 13, 2005 for review on July 21, 2005. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: (tii t1. Please enter the weir elevation on the Forebay Wall Design detail on Drawing C- Please correct the pond depth elevation to 30.0' and excavation depth on the to Pond W/Forebay detail on Drawing C-1. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to August 2, 2005, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. North Carolina Division of Water Quality 127 Cardinal Drive Extension Phone (910) 796-7215 Customer Servicel-877-623-6748 Wilmington Regional Office Wilmington, NC 28405-3845 FAX (910) 350-2004 Internet: h2o.enr.state.nc.us One NofthCarolina AI&WAY An Equal Opportunity/Affirmative Action Employer— 50% Recycled110% Post Consumer Paper Mr. Broadus E. Hill, III July 26, 2005 Stormwater Application No. SW8 990719 Modification Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7301. Since ly, Paul T. Bartlett, P.E. Environmental Engineer ENB/ptb: cc: S:\WQS\STORMWATER\ADDINFO\2005\990719Mod.juIO5 John K. Klein, P.E., Wrightsville Engineering Services, PLLC Paul Bartlett Page 2 of 2 Web's Topographic Map T,/.�,eP, .,I C�� ✓hrP.✓ f4&4/79zv Page 1 of 1 rx v, y Fi ` '}fi• l+ 1. 7�• C. � • f I l s�••t" +jyr. �. •. - ,;' t .. '• . �' - ;' •`Y` r � �t � ....'•,T ••./,�'".3 r •�' a .. .. �'�Iw f• S fee" ' �'i.• {fr 1 r �; 'f � :Sl .�, ` ' ' {•. _ t tit '. 4L;CCJJ�i^ r� e� �e yk•,• f� �iv. VI. :or ,:.rii • ', _Sse±'.+r -� +;::t' �+- 4`: � -• � h `J�.y- y� y:,,�...,� ., E ` ' f��.'�-y, t, .�:..-��_'[•/�� f�j` A,,. . t Y f �' "^ �� , � , y r '.;•� U��' lo/• �T} Y�"' +' r ;;tj �, �F` �: �,'� #. �b �. •� .. Kt � '..w '+•}! _.. '� !•., ki' :•a i'+•". .`.. .��/ yr%"�, .'lY//aa// a Fi`-_ rr r;: /' . to f •i . �� ,«s; '.+ tj rY•.f'=:� `r .1�!;`. �4 - a" A•. 1 .+ 1 Yw ` F.i'' j �F t .•�,tt%�• F .hM.•.Z'`.'�i a =. l'.� Q 1w.il 1�»:Y y� i t, -fir -' tti �tl:! ^L;,Nty ��i: •it iti� r'+ +1k" (2 t /. {rf f 4�.'" -'Y �i Ai r ... :.�^ • V'� r � s- �`� a t � t 11 1 � .wJ '.' � ::.• �rY`� 1 1+' •!.;'��.t» r 19'---wC'~.v. .-7 '^-�. v'tiY! 'L• ��a y�{J� 1Q�.` .• •=., 1 ���`1 r' ! ` .�1' i -�` . � ' t rF 'u^• �t �,'S K K k�+. �• `Y '� R. IrrY t f i+ t.. } "` 'a .� � of fif r � t � •Jf .. v Y j �.•: S� Xe 1 f••' }•.r+.:. w'-f+ S I. " .t - , .'• Yi. •� ,tea,' !, j "\.•I ' }. ee •' C .rF..' l o +/. � 7y� e+. n •••i ''' a '�'•{ y / r �-•: J �^_ � �':.r�'T' + � . k' ~ r+ •� ti t' tfJrlr-' .Ir b• ff�lf-+^i•F- sew T-.4 ham•,}. �-a•. ! t. t +++'f +' +•e .;,f M* 0 0.3 0.6 0.4 1.2 1.5 km 0 0.1 0.2 0.3 0.4 0.5 mi Map center is 340 17.100'N, 770 52.001W (WGS84/NAD83) Scotts Hill quadrangle 117-9034 Projection is UTM Zone 18 NAD83 Datum G=-1.617 http://www.topozone.com/print.asp?z=18&n=3799141.45539714&e=236163.338216051 &... 7/26/2005 Trademark Center SW8 990719 Modification Subject: Trademark Center SW8 990719 Modification From: Paul Bartlett <Paul.Bartlett@ncmail.net> Date: Mon, 25 Jul 2005 16:15:46 -0400 To: Cameron Weaver <Cameron.Weaver@ncmail.net>, Linda Lewis <Linda.Lewis@ncmail.net> The mystery of SW8 030510 might be solved! SW8 990719 Mod was issued 7/23/03 for Northchase Auto-Shine/Trademark Corner. A permit number had been deleted from the application and SW8 990719 Mod written in. The only record of 030510 is an Add Info fax in 2003 from Laurie Munn. I think 030510 was opened and then Laurie realized the application was a permit modification and rescinded the number, although the number remains in BIMS. So there are no files for 030510 and there shouldn't be. I talked with John Klein; has has no knowledge of 030510. His records show 990719 and 961104 (off -site treatment). Cameron, please have Lindsay close out the 030510 number (permit issued as SW8 990719 Mod, 7/23/03) in BIMS and process the new application for Trademark Corner as SW8 990719 MOD only. Thanks, Paul 1 of 1 7/25/2005 4:16 PM Transmittal Toe Water oualty supervisor Fmw John K. Klein, PE DQ Broadus E. lit, III Date: 7112105 Poc) PON Trademark Comer, Modification to SIM 990719 File No.: 25016 FAST TRACK SUBMITTAL The Developers of the tract, Trademark Comers, LLC, has requested that the project be fast -tracked in the most expedient fashion possible. We realize that the project has not had a pre-app meeting; however, the information was forwarded prior with the meeting canceled at the owner's request. Due to the I,fi'o available._ nature of the project, we are requesting that the project be reviewed at the earliest slot The prig' project name orthC se AutoShin�' to be incorporated into the new project area which expands the project area, renames the o tact, revises the ownership and provides construction of a new wet dekation basin for the project thereby removing the project from the NorthChase Apartments regional stor water pond. This new submittal provides for future development within the project area. Enclosed for your needs are: Completed original StomMater Management Permit Application Form plus one (1) copy Original Wet Detention Basin Supplement Permit application processing fee of $420 Two (2) Copies of the detailed Narrative with Calculations Two (2) copies of the Drawing Should there be any questions conceming the enclosed information, please feel free to contact our office. Thank you SW 6L 1 3LU05 Dad 1 D rnod 3410 Wrightsville Avenue Wilmington North Carolina 28403 910.799.7967 Fax 910.793.0599 DESIGN NARRATIVE SEDIMENATION CONTROL SPECIFICATION AND DRAINAGE CALCULATIONS for TRADEMARK CORNER NORTHCHASE PARK OF COMMERCE 2715 TRADEMARK DRIVE NEW HANOVER COUNTY, NORTH CAROLINA PREPARED FOR Trademark Corners, LLC 807 Wood Cove Drive Wilmington, NC 28409 (910) 791-2666 July 2005 FILE NO.: 25016 CAN �loo�,,. ��,.�� RECEIVED 1ArL R s-wgI g0Ir9r+�o p AA w Si. 6 In 'rree��i�t��Na 'REPARED BY WRIGHTSVILLE ENGINEERING SERVICES, P.L.L.C. 3410 Wrightsville Avenue Wilmington, NC 28403 (910) 799-7967 TABLE OF CONTENTS DESIGN NARRATIVE DWQ STORMWATER DESIGN AND SEDIMENT CONTROL 1-INCH STORM DESIGN RIP -RAP OUTLET DESIGN POND DESIGN, POSTDEVELOPMENT RUNOFF RATES 2-YEAR 10-YEAR 25-YEAR 100-YEAR EROSION AND SEDIMENT CONTROL SPECIFICATION DESIGN NARRATIVE 1. GENERAL: The purpose of this submittal is to present design of the stormwater management measures for the subject site. Included within this submittal are the Drawings and Storm Drainage Calculations. All items are part of the overall plan and included by reference. This submittal involves modification to permit number SW8 990719, NorthChase Auto -Shine to include the adjoining tract also under common ownership. Both tracts were originally designed to discharge into the DWQ wet detention pond at NorthChase Apartments to the south; this submittal wilt include design of a new pond to serve the site and disconnection from the existing pond. The owners also desire that the new permit be issued in the name of the parent company, Trademark Comers, LLC. 2. EXISTING SITE: The existing site is completely cleared with low grasses. Soils are predominately Leon (Le). Overall, the site is moderately drained due to the nearby roadway collection swales which are located to the north and east of the subject property. The site falls within the drainage boundary of Smith Creek, a class C-Sw water as was noted in the original submittal documents. 3. PROPOSED IMPROVEMENTS: This proposal calls for the construction of a wet detention basin to serve the existing NorthChase Auto -Shine as well as allocations for future development on the comer tract. The existing outlet pipe discharging to the south wiH be incorporated into the design with the remainder of the piping removed and the downstream inlet opening plugged. Due to space limitations, the pond -will be constructed rising a Beta-unii-vg welt strruciure around the perimeter, 1 op of the wall shall be a minimum of 36.0 (existing ground surface) with a bottom grade elevation of 34.0. Calcutation of the 14nch storm volume indicates that the 1-inch storage volume will occur below the elevation where the wall occurs. Storage above this elevation are designed to meet NHC predevelopment runoff rates. 4. STORM DRAINAGE CALCULATIONS: Calculations for the project involve design. of the wet detention pond to satisfy state and local requirements. State requirements were designed using. appropriate methods used by NCDNR for wet detention basins and pond sizing calculations. Modeling for the past -development runoff involved breaking the project into two drainage basins: the pond collection area; and, those grassed areas which drain away from the project. Based on the site data, these areas are 1.10 acres and 0.4 acres respectively. The combined flow from both of these were evaluated to the predevelopment rate of runoff. Post -development runoff calculations were made using a TR-20 analysis with the HydroCAD modeling software furnished by Applied Microcomputer Systems. Based on our evaluations, the pond will be adequate to meet pre -development rates of runoff. Refer to the Design Calculations for additional review. Page Two Design Narrative Trademark Corner The 100-year storm event was evaluated to ensure that the emergency spillway will contain the overflow without overtopping the top of the pond perimeter. Based on the routing using the 100-year storm, the maximum pond height will be approximately 35.14 MSL. The existing building finished floor is well above this elevation and will not be threatened should this level occur 5. EROSION CONTROL CONSIDERATION: As no real land, dishwbing, except for the pond construction itself, it to be done, sedimentation and erosion control is to be handled by use of silt fencing around the perimeter of the project. Additional measures proposed include but not limited to the following: a. Use of temporary seeding should construction activity be halted for the designated time periods. b. Rip -rap protection at all pipe ends. c. Silt fencing around sensitive areas and perimeter areas. DWQ STORMWATER DESIGN, PREDEVELOPMENT RUNOFF RATES AND SEDIMENTATION CONTROL DESIGN Wrightsville Engineering Services, PLLC PROJECT: Trademark Corner PROJECT NO.: 25016 CLIENT: Trademark Corner, LLC DATE: Jury 2005 LOCATION: NorlhCihase, New Hanover County, NC PREPARED BY: JKK SUBJECT: Stormwater Calculations GIVEN: Design for detention pond drainage basin. Design Storms: 2-year, 10-year and 25-year Soils: Leon (its) Hyrologic; Group: B 1. PROJECT AREA (PA) : (See Plan) PA = 6W47 SF = 1.50 Acres Comprised of the following types of regions: Areas Draining to the Detention Pond = 1.10 Ac Other non -built -upon area not collected into pond (wetlands, etc) = 0.40 Ac Total: 1.50 Acme 2. RUNOFF COEFFICIENTS: Preconstruction (undeveloped) = 0.30 Impervious = 0.95 Turf (developed) = 0.Z0 3. RAINFALL INTENSITY: Use Klrpich Method Average Predeveloped Slope: Larvest Length (L)= 295 Vertical Drop = 1.5 Watershed Slope = 0.51 % Tc ((LA3/H)A0.385)/128 where: L = 295 ' H= 1.5' Therefore, To = 5 min. USE: 5 min 4. RAINFALL INTENSITY: (see dwM For 2-year, 5 min storm, intensity () = 5.88 in/hr For 10-year, 5 min storm, intensity (i) = 7.23 inthr For 25--,^=r, 5 min stur,-n, intens4 (i) = 8.15 inthr For 100-year, 5 min storm, k tensky (i) = 9.6 Whr Rainfall Amounts, 24-hr Storm Event (for pond routing): see dart For 2-year, 4.50 in For 10-year, 7.00 in For 25-year, 8.05 in For 50-year, 9.00 in For 100-year, 10.00 in 5. DETERMINE PEAK DISCHARGE (Q): Q= C x i x A Q (cfs); A (acres) i (in/in) a. Predevelopment Rate (Qpre): RETURN f A RUNOFF PERIOq C i( nlhr) (AM (CFSI 2 0.30 5.86 1.50 2.6 10 0.30 7.23 1.50 3.3 25 0.30 8.15 1.50 3.7 100 0.30 9.6 1.50 4.3 6. Summary of Wit -Upon Areas into Pond: 25016 - Trademark Comer Wrightsville Engineering Services, PLLC Parking - 1S207 SF = 0.42 Acres Buildings - 2807 SF = 0.06 Acres Sidewalks - 0 SF = 0.00 Acres Future Development - 168M SF = 0.39 Acres Total Built Upon Area = ✓ 37814 SF = 0.87 Acres w Turf. 10102 SF = 0.23 Acres Pond bA Buift-upon = 0.868 Ac / 1.10 Ac = 78.9 % use: 80.0 % 7. RATIONAL METHOD RUNOFF COEFFICIENTS FOR PIPING: impervious = 0.87 Ac x 0.95 = 0.82 Turf = 0.23 Ac x 0.20 = 0.05 1.10 0.87 Weighted C Factor = 0.79 use. 0.80 8. STORM DRAINAGE DESIGN: Refer to StormCad design data for piping 9. DETENTION POND DESIGN: Design to shore the first 1-inch of runoff from project area Imperv. 1.00 x 37814 SF x 1'/12' = 3151 CF Turf 0.20 x 10102 SF x 1'/12' = 168 CF 3320 CF Based on stale requirements for ponds without vegetative filter and using the design impervious percent of ✓ 80.0 with a depth of -3.0 feet, the ratio of surface area (SF) to drainage area to drainage area (DA) _ / 9.40 Therefore, minimum required pond surface area (SA) is: 9.40 x 1.100 / 100 = 0.10 Acres 4504 SF AVE. CUMUL AREA AREA VOLUME VOLUME ELEV. (SFI Sf_ZF fm , CF 30.0 2488 2949 31.0 3409 3905 32.0 4400 5478 33.0 41. �3 7138 34.0 77 7719 35.0 7719 7719 36.0 7719 Depth where storage requiremw-it met: Depth of Required Storage: Elevation of Top of Riser. Depth of Storage Provided: Volume of Storage Provided: 0 (Pond Design Bottom) 2949 Yf, (Volume below surface) 2949 w 3905 6853 w 5476 2331 (neat Pool Eleva *m) 7138 -..--' 7138 (Volume above surfacel 7719 �pG7 1`85 w 7719 22576 33.47 0.47 VF or 33.47 0.47 VF or 3320 CF✓ 5.6 Inches 5.6 Indies 25016 - Trademark Comer Wrightsville Engineering Services, PLLC 10. DWQ ORIFICE DESIGN: Design orifice for dirge allowed using the fotloweng equation Q= C x A x (29h)An 5 where: Q = CFS C = Orifice coefficient = 0.6 A = Orifice Area (SF) g = 32.2 ft/s2 h = pressure head (ft) Rearranging the above equation for A yields: A=Q/Cx(2gh)^0.5 Design parameters: Pond Outlet Invert = 33.00 14nch storage level = 33.47 Average Pond Elevation = 33.23 Trial Orfice Design = 1.250 Orifice Centerline = 33.1 Ave Pressure Head (h) = 0.18 Pond Volume: 3320 CF 3320 CF Time to Drain: 2 Days 5 Days Release Rate: 0.019 CFS MODS CFS Orifice Area: 0.0094 SF 0.0038 SF Orifice Diameter 0.109, 0.(W ' 1.312 " 0.83 " USE FOR DESIGN: 1.250 ,. Actual Draw -Down Rate = 0.017 CFS Actual Ave Draw -down time = 52.9 Hours = 2.2 days 11. Forebay Design Req: Design trebay for 20 % of the total volume below permanent pool. Volume below surface: 12331 CF FOREBAY VOLUME AVE. CUMUL AREA AREA VOLUME VOLUME ELEV. (SF) (SF) (CF) (CF) 30 45 0 152 152 31 259 152 392 544 32 524 696 33 1874 1099 1643 0 2338 2338 Total Volume Below Normal Pool Elevation = 2338 Percent Forebay vs Total Volume = 19.0 % 12. Forebay Weir Design (see NydroCAD cads for basin with 25year storm) weir equation: Q = C x H1312 x (L - 0.2H) where: Q=CFS 25016 - Trademark Comer Wrightsville Engineering Services, PLLC C = weir coefficient = . 3.33 L = weir length (FT) = 2 x H (min) H = head (FT) rearranging and solving for weir length yields the folkyMng: L=(Q!CxHA312)A0.2X Forebay Flow Rate: Q = 8.72 CFS (see HydroCAD calos) Set invert at normal pod elevation = 33.00 Design weir capacity = 8.72 CFS Design weir depth = 6 " = 0.50 FT Therefore, required weir length = 7.51 FT use: 8 FT 14. Pond Summary: Storage Volume Provided = 3320 CF Pond Outlet Invert = 33.00 Design Storage Elevation = 33.47 Depth = 0.47 VF Pond Bottom Elevation = 30.00 Outlet Orifice Diameter = 1.25 inches Ave Discherge Rate = 0.017 CFS Anticipated drawdown time 52.9 Hours = 2.2 Days 15. Rip -Rap Outlet Cakulatlo .- Refer to Figure &06.b.1 and 8.06.b.2 for rip rep design charts Pond Inlet: Pipe Diameter = Q(25) Peak Flow Rate = Velocity at end of FES = From Figure 8.06.b.1, case falls within Zone 1 Therefore, apron length = 4 x D = Pond Outlet Pipe Diameter = Q(10) Peak Flow Rate = Velocity at end of FES = From Figure 8.06.b. J , case foie widin Zone 2 Therefore, apron length = 6 x D = 24 inches = 2.0 Ft 8.72 CFS (see HydraCAD calcs) 5.02 FPS (refer to FlowMasher Cakes with FES width) 8.0 FT using Class A rip -rap 12 inures = 1.0 Ft 2.12 CFS (see HydraCAD calcs) 9.07 FPS (refer to FkowMaster Cakes with FES width) 6.0 FT using Class B rip -rap 16. Summary of Pre and Post Development Calculations: Refer to HydmCAD model output for detailed evaluation of each node. The project was modeled as aonsistirog of drainage basins and catch basins corresponding to each of the proposed inlets. The routed runoff was passed thru the pond with post-developnoent amounts being determined STORM PREDEVELOPMENT POST DEVELOPMENT EVENT RATE (CFS) RATE (CFS) 2 2.6 0.5 10 3.3 2.1 25 3.7 3.1 100 4.3 4.6 25016 - Trademark Comer N" II as% TS6 RBWVAL 301OOT VBG=72P FMTSB Rl9Q�J1 tip 3' IS' 4.0' 4.F SO 5.5' b.w 6.5' W 10% .9 .$ .7 .6 .S 0 0 0 2D% 1.7 1.3 1. 1.1 1.0 .8 .7 .5 .5 30% IS 2.2 1.9 1.5 1.3 1.2 1.0 .9 40% '3.4 3.0 2.6 2. 1 1.9 1.6 1.4 Ll 1.0 50% 4.3 3.7 3.3 3.0 2.7 .� 2.1 1.9 1.5 1.3 69 % 3.0 4.5 _3 3.5 3.2 2.0 .6 2.3 2.0 1.6 70% 6.0 .2 4.5 4.1 3.7 3.1 2.9 2.S 2.1 1A 60% 6.a 5.2 . 4.7 4.2 3.7 3.2 2. 2.2 2.0 90% 7.5 6.5 5.9 5.3 4.9 4.3 13.5 !i &2 7.4 +6.9 6.2 5.6 3.0 4.4 LIS 3.2 ft% T85 RZMYAJ6 NO VWWAT= MLTIMR RWJU1 m =wm 31 3.S' 4.0' 4.5' 5.0' 53' CO' 6.5' 7.0' 7J? 109 11.3 1.0 .8 .7 .6 .5 .4 .3 .2 .1 2DX 2.4 2,0 1.8 1.7 1.5 11.4 1.2 2.4 .9 .6 30% 3.3 3.0 2.7 2.5 2.2 1.9 1.6 1.% 1.1 .8 40% 4.5 4.0 3.5 3.1 2.8 2.5 2.1 1.8 1.4 1.1 50% 5.6 3.0 4.3 3.9 3.5 3:1 2.7 13.4 2.3 IS LS 600 7.0 6.0 5.3 4.9 4.3 1_9 2.9 2.4 1.0 70% $.1 7.4 6.0 5.5 A 5.0 14..s 3.9 14 2.9 2.3 � 80lb 9.4 8.0 7.0 6.4 1.7 5.2 4.6 4.0 3.4 2.$ 90'S! 10.7 9.0 7.9 7.2 6.5 S,9 5,2 4.6 3.9 3.3 1 ' 12.0 10.0 $_t 8.1 7,3 6.6 5.9 S.1 4.3 3.6 M to PM)Viow-ld me Cut NAWHMioyER Coom7STORM WATER DBMGNMRNUAL SEG'T!owO - RUNOFFDETMWmArtoNPRocBDURES TABLE 40 3 NEW HANOVER COUNTY DEPTH - DURAriON - FREQUENCY TABLE TABLE 40-3A Duration Return ftiod 2 }+r S-yr 1 ayr 2S-yr 50-yr 1 p0.yr (time) () (in) (xn) (M) (in) (in) 5 miry 0.49 0•55 0.60 0.69 0.74 0.80 10 min 0.89 0.99 1.07 1.20 1.31 1.41 15 min 1.15 1.29 1.40 1.57 1.70 1.84 30 min 1.62 1.92 2.14 2.47 in 2.99 60 min 2.10 2.58 2.92 3.41 3.80 4.18 2 hr 2.50 3.30 3.60 4.20 4.70 5.20 3 hr 2.80 3.50 4.05 4.70 S.20 5.80 6 hr 3.30 4.20 4.82 5.71 6.40 7.00 12 br 3.90 5.00 5.80 6.90 7.70 8.60 L.24 hr 1 4.50 5.80 7.00 8.05 9.00 10.00 TABU 40-3B Duration Return Period 2-yr yr 1 ayr 25-yr 50-yr 100-yr (time) (inlhr) (inlhr) Ouft) (hv'hr) (inft) (in/hr) 5 mm 5.88 6.63 7.23 8.I5 8.87 9.60 10 min 5.28 5.91 6.43 7.22 7.85 8.48 15 min 4.60 5.15 5.59 6.27 6.82 7.36 30 min 3.23 314 4.29 4.94 5.46 5.97 60 min 2.10 2.58 2.92 3.41 3.90 4.18 2 hr 1.25 1.65 1.80 2.10 2.35 2.60 3 hr 0.93 1.17 1.35 1.57 1.73 1.93 0.55 0.70 0.80 095 1.07 1.17 L24hr 0.33 0.42 0.48 0.58 0.64 0.72 0.19 0.24 0.29 034 0.39 0.42 Source: Latest Versions ofNWS TP-40 and NWS H dro-35 3+ ADOPTED SEPMWM S. 2000 PAGE 40-5 Pond Inlet Velocity Worksheet for Rectangular Channel Project Description - Project File d:Vandpr-2125016-11riprap.fM2 Woricsheet Pond Inlet Rip Velocity Flow Element Rectangular Channel Method Manning's Formula Solve For Channel Depth Input Data -- Mannings Coefficient 0.013 Channel Slope 0.76 % Bottom Width 47.75 in Discharge 8.72 fLO/s Results Depth 0.44 ft Flow Area 1.74 ft2 Wetted Perimeter 4.85 ft Top Width 3.98 ft Critical Depth 0.53 ft Critical Slope 0.004169 ft/ft Velocity 5.02 ft/s Velocity Head 0.39 ft Specific Energy 0.83 ft Froude Number 1.34 Flow is supercritical. Jul 11, 2005 KLEIN ENGINEERING AND ASSOCIATES ROWMaster v4.1 c 14.29.'S6 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Pond Outlet Velocity Wbrksheet for laeclaingular Channel Project Description Project File d:llandpr-2125016—ftprap.fm2 Worimheet Pond Outlet Velocity Flow Element Rectangular Channel Method Manning's Formula Sohre For Channel Depth Input Data Mannings Coefficient 0.013 Channel Slope 12.50 % Bottom Width 23.50 in Discharge 2.12 iP/s Results Depth 0.12 ft Flow Area 0.23 fl2 Wetted Perimeter 2.20 ft Top Width 1.96 ft Critical Depth 0.33 ft Critical Slope 0.005249 ft/ft Velocity 9.07 ft/s Velocity Head 1.28 ft Specific Energy 1.40 ft Froude Humber 4.63 Flow is supermilical. Jul 11, 2005 KLEIN ENGINEERING AND ASSOCIATES FlowMaster v4.1 c 14:31:49 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 766-1666 Page 1 of 1 Appendices NEW YORK DOT DISSWATOR METHOD FOR USE IN DEFINED CHANNELS (Serum: 'Bank and channel lining procedures", New York Department Of Transportation, Division of Design and Construction, 1971.) Note: To use the following chart you must know: (1) Q full capacity (2) Qto (3) V full (4) Vlo where Q = discharge in efs and = Velocity in FPS. ESTIMATION OF MIME SIZE AND DIMENSIONS FOR CULVERT APRONS Step 1) Compute flow velocity V, at culvert or paved channel outlet. Step 2) For pipe culverts Do is diameter. For pipe arch, arch and box culverts, and paved channel outlets, Du=Ao. where A.= cross -sectional area of flow at outlet. For multiple culverts, use Det�1.25xDo of single culven. Step 3) For apron grades of 10% or steeper, use recommendations For next higher zone. (Zones 1 through 6). s- ■r■u Y�p,rrYi�4Mlrruusl.ncrr�[Q ���maaaaroinssa.r�ar yip, rM rrar�oruarr,ra i�o>mo ■rsamr mc�Or� m muaKuKAffm wraum d ■>a[rlar■= n■' �■rrrii�Triwr r.rrrrl■r�rmas 1MT4_ +�_ IIllgt#A.t*"KplQ rvrrr=torer.su>s■r::sr r�ualaQal[.a41alsl�q� p �`� lu■a�u_ rim*rt�mruvrra=tiarrml..aRa ar:rl,'zs*.earl=nmrrr �mn�rrtiu ar� err= r�o�rr�.Qra�,arp saays'-ter >isa■.■r■=Offlapns. al�raaaiom�arlar Inn� ■r.r, ia�1■a1r111Qilrr a01 �AIm�mrommmWW" r=�"'n"'onarrits iaiu �Illrrrr■ '[{.>/■rrq\frrl��ila v rlin�o'■rrac`�irrrvi 1 Yrr lsR►■l.ir rrri�r rrl �xrr ��l11171r1R®fIi1R¢rrl=ril e■!. IlQarrrrr�lp ■� �� t1own"Nsl ■R'l�■rlatpf.r�''f71101 .MA�<Rlli=1>f..airarrrlrailrrrltrRrlrir ENMA" —rslllW ■a A m�t�=itrir��r`'.vaor+trq A2mLm Ir�rr�un=rnum &'�WjLWA arw■rar►�ar '1�ttamar.��[■e[u ;�iarrr■1Q�r11�rarer■rrlrr wn ��� [rAw ¢n�a�ir�ti�i�■a■m iw�iK;arst�m�r I ft m reqlaout,�narraml ] 20"m �lrlrr.►tarrtr, erne- lolrriut.=cioi■.r■-vsa.nlnul. rrmnu-".aswaa ruarar>rai ■�i�rii�Lie�rXjr"X l�rriiiiaaairariusanrums �a:u�;1a RIN!'! �uom .�:,� R�rYRttirilrliNrf"O!wO■.rl- rare■u►rrar ra.<rrsrri u,vn ream urrr�arrr■■r r aarrlr IIIaipwra■■rlamr ra=�acuarr ■r■ err o ■■ rr�ln,q, r■t+iliitrr�u■rw�r�irr■.rarsa�urrrrr.0 reel rlrrrr lolrr��rair ■rrl■lrtar ■rrrra u _a�YrOti`rrr.rrrltt■r HrllW,�lril<r�•rr r-•U17r■�.r.r.�� alr■oum/u.rnl�i;w■M>tartar■r b`■rra=1#■llq/l9=7 5' f 0' 15` 20' 25' DIAMETER (Ft) Figure 8.06.b.1 ttm IZ03 8.06.3 0 _ . � rv" M MATE AL P40Y CT CLOEF f I TO FREVEW bCOUR AM [H �L21lLWA S t STONE FILLING (FINE) 3 x Qo 4 x Do 3 x Do 6 x 2 STONE FILLING (LIGHT) CL 8 3 ISTONE FILLING (MEDIui CL_ 1- ~_ 4 x Do ` _Do 8 x Do 4 STONE FILLING (HEAVY) CL. t 4 x Da S x Do 5 STONE FILLING (HEAVY) CL. 2 5 x Of 10 x Do 6 STONE FILLING (HEAVY) CL 2 6 x Do 10 x Do T SPECIAL STUDY REOUIRED ENERGY DWIPATORS, STILLING BASIN OR LARGER SIZE STONE). Fig. 8.06.b.2 Width = 3 limas Pipe dk (min.) (DETERMINATION OF STONE SIXXS FOR DUMPED STONE CHANNEL LININGS AND REVETMENTS Step 1) Use figure 8.06.b.3 00 determine maximum stone size (e.g. for 12 Fps --?A" or 5501bs. Step 2) Use figure 8.06.b.4 to determine acceptable size range f(3r stone (for 12 FPS it is 125-500 lbs. for 75% of scene, and the maximum and minimum range in weight should be 25-500 lb&) Note. In determining channel velocities for stone linings and revetmen4 use the following coe0icients of roughness: Diametef Mannin's Min. ikesuxmw --(inches) "n" of fining (inches) Pima 3 0.031 Light 6 0.035 Medium 13 0.040 Heavy 23 0044 9 12 12 1g 18 24 30 36 (c]wMIS) (Dirapswo 5.06.6 Rev. IZA3 Precast F�Inurred Concrete Flared End Sections ,��► rr�g oLJ FAWble P/gsdc Type Mhfs SpedficaUO178: N.r Department of TransporWbI7 fifi F3 lik 77 T 1 M -4 K- TTf OD NJ D Wall At Jj4 1 jk �—.- C 5OR D Well I OD L I A 8 C E P 10 H J I K M Wt. 12'i 2 16 75 4 24% 5Ql/s 23% 141A 13% 13% 1314 14dt 13A 650 15 2% 19% 75 7 19% 45% 30 17% 167 17% 16% 2 2 880 18 24 2% 23 75% 9 19 461/2 36 20"%a 201A 20% 19% 2 2 1.170 30 3 31& 30 37% 733A '73% 11 13% 421A ` 52 3114 21'A 47SA 59% 27% 341Aa 27 331A 2M ' 333A 26% 32% 2% 2A 2% 2Va 1,460 3614 42 41/b , 44 51 ` 99 90 16 22 61 % 63% 3ra 341A I 71 77 41 40 397'e 38% 3% .a S1 A 2.000 3,600 48 5 58" 983A 25% 69% 291A 84 471A 53% 467A 521;%s 46 521A 451/ 517/e 4% 4% 31/2 3% 5,100 6,200 154 60 6% 6 65 72 100 99 27 65 35 90 58% 589N 58% 671/2 4% 4% 30 60 39 96 65% 65 643A 64 43A 43A 11,650 ' 0D at joint is enlarged to C Wall N.C. Products Corp. P.O. Box 2M77 Leigh! EV C. 27+611 (919) &,�4.2557 Drainage Ba 'n 2P DWQ Pon Combined Su [Reach o Link (3S) Areas Pond Calcs Type It/ 24-hr Rainrfall=4.50" Prepared by Wrightsville Engineering Services, PLLC Page 1 FlydroCADO 7.00 s/n 001707 019W2003 Applied Microcomputer Systems Subcatchment 1S: Drainage Basin Runoff = 4.60 cfs @ 12.07 hrs, Volume= 0.313 af, Depth= 3.41" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Type III 24-hr Rainfall=4.50" Area ac CN Description 1.100 92 Urban commercial, 85% imp, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (f tft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 1S: Drainage Basin Hydrograph Type III 24-hr 4 Rainfall=4.50" Runoff Area=1.100 ac 3- Runoff Volume=0.313 of Runoff Depth=3.41" 2- TC=5.0 min CN=92 1-1 il 0 i a a 10 11 12 13 14 15 16 17 18 18 20 Time (hours) Pond Calcs Type !ll 24-hr Rainfall=4.50" Prepared by Wrightsville Engineering Services, PLLC Page 2 HydroCADD 7.00 s/n 001707 01986-2003 Awied Microcomouter Svstems Subcatchment 3S: Uncollected Areas Runoff = 0.46 cfs @ 12.09 hrs, Volume= 0.032 af, Depth= 0.97" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Type III 24-hr Rainfall=4.5V' Area (ac) CN Description 0.400 61 >75% Grass cover, Good, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (fifft) (fused) (cfs) 5.0 Direct Entry Subcatchment 3S: Uncollected Areas Hydrograph Type Ili 24-hr 04 Rainfall=4.50" 0.35. Runoff Area=0.400 ac ° Runoff Volume=0.032 of o °25 Runoff Depth=0.97" 02 Tc=5.0 min 0.15- CN=61 0.1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time (hours) Runoir Pond Calm Type N 24-hr Rainfall=4.50" Prepared by Wrightsville Engineering Services, PLLC Page 3 HydroCAQV 7.00 s1n 001707 01986-2003 Applied Microcomputer Systems Pond 2P: DWQ Pond Inflow Area = 1.100 ac, Inflow Depth = 3.41" Inflow = 4.60 cfs cQ 12.07 hrs, Volume= 0.313 of Outflow = 0.29 cfs @ 13.61 hrs, Volume-- 0.117 af, Atten= 94%, Lag= 92.3 min Primary = 0.29 cfs @ 13.61 hrs, Volume= 0.117 of Routing by Star -Ind method, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Peak Elev= 33.91' @ 13.61 hrs Surf.Area= 7,189 sf Storage= 9,542 cf Plug -Flow detention time= 278.7 min calculated for 0.117 of (37% of inflow) Center -of -Mass det. time=172.0 min ( 927.4 - 755.4 ) # Invert Avail'.Storage Storage Description 1 32.50' 24,591 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 32.50 6,047 0 0 33.50 7,189 6,618 6,618 34.50 7,189 7,189 13,807 36.00 7,189 10,784 24,591 # Routing Invert Outlet Devices 1 Primary 33.00' 12.0" x 8.0' long Culvert RCP, square edge` headwall, Ke= 0.500 Outlet Invert-- 32.00' S= 0.1250 T n= 0.013 Co= 0.900 2 Device 1 33.00' 1.3" Vert.,Orific elGrate C= 0.600 3 Device 1 33.65' 10.0" Vert. Orific afGrate C= 0.600 Primary Outflow Max--0.29 cfs @ 13.61 hrs HW--33.91' (Free Discharge) t-'! !v-art (Passes 0.29 cfe of 2.43 cfs potential flora) 2=0r1flce1Grate (Orifice Controls 0.04 cfs Q 4.4 fps) rificelGrate (Orifice Controls 0.25 cfs @ 1.7 fps) Pond Calm Prepared by Wrightsville Engineering Services, PLLC HydroCAD® 7.00 sh 001707 01986-2003 Applied Micmwm 1 Pond 2P: DM Pond Hydrograph 4.60 dTs Inflow Area=1.100 ac Peak Elev=33.91" Storage=9,542 cf Type /it 24-hr Rainfall=4.50" Page 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 W 18 19 20 Time (hours) Innow MY Pond Cales Prepared by' R Services, PLLC Link 4L: Combined Type 11124-hr Rainfa11=4.50" Page 5 Inflow Area = 1.500 ac, Inflow Depth = 1.20" Inflow = 0.48 cfs @ 12.09 hrs, Volume= 0.150 of Primary = 0.48 efs @ 12.09 hrs, Volume= 0.150 af, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Link 4L: Combined Hydrograph Inflow Primary 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time (hours) Drainage Ba 'n 2P DWQ Pon Su Rich on [Unk (3S) 4L Combined t®a%deAQ� <.M%M Areas Pond Calcs Type 11124-hr Rainfall=7.00" Prepared by Wrightsville Engineering Services, PLLC Page 2 HydroCAD® 7.00 s!n 001707 01986-2003 Applied Mcrocomputer Systems Subcatchment 1S: Drainage Basin Runoff = 7.51 cfs @ 12.07 hrs, Volume= 0.527 af, Depth= 5.75" Runoff by SCS TR 20 method, UH=SCS, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Type Ill 24-hr Rainfall=7.00" Area (ac) CN Description 1.100 92 Urban commercial, 85% imp, HSG B Tc Length Slope 5.0 1 Capacity Description Direct Entry, Subcabchment 1S: Drainage Basin Hydrograph Type III 24-hr Rainfall=7.00°° Runoff Area=1.100 ac Runoff Volume=0.527 of Runoff Depth=5.75°° Tc=5.0 men CN=92 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 16 19 20 Time (hours) Pond Calcs Type 11124-hr Rainfall=7.00" Prepared by Wrightsville Engineering Services, PLLC Page 3 HvdroCAD® 7.00 stn 001707 01986-2003 Ana6ed Microcomputer Svstems Subcatchment 3S: Uncollected Areas Runoff = 1.28 cfs @ 12.08 hrs, Volume= 0.083 af, Depth= 2.48" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Type III 24-hr Rainfall=7.OV' Area (ac) . Chl Description 0.400 61 >75% Grass cover, Good, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 3S: Uncollected Areas Hydrograph 12B ds Type III 24-hr Rainfall=7.00" Runoff Area=0.400 ac Runoff Volume=0.083 of Runoff Depth=2.48" Tc=5.0 min CN=61 0 1 2 3 4 5 a 7 fS 9 10 11 12 13 14 15 16 17 1R 19 91 Time (hours) — Runoff Pond Calm Type III 24-hr Rainfall= 7. 00 " Prepared by Wrightsville Engineering Services, PLLC Page 4 HydroCAD® 7.00 aln 001707 019W2003 Applied Microcomputer Systems Pond 2P: DWQ Pond Inflow Area = 1.100 ac, Inflow Depth = 5.75" Inflow = 7.51 cfs c@ 12.07 hrs, Volume= 0.527 of Outflow = 1.67 cfs @ 12.46 hrs, Volume-- 0.325 af, Atten= 78%, Lag= 23.5 min Primary = 1.67 cfs @ 12.46 hrs, Volume= 0.325 of Routing by. Stor-Ind method, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Peak Elev= 34.44' Q 12.46 hrs Surf.Area= 7,189 sf Storage= 13,365 cf Plug -Flow detention time= 192.0 min calculated for 0.325 of (62% of inflow) Center -of -Mass det. time= 114.6 min (857.7 - 743.2) # Invert Avail.Storage Storage Description 1 32.59 24,591 cf Custom Stage Data (Prismatic) Listed below T Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 32.50 6,047 0 0 33.50 7,189 6,618 6,618 34.50 7,189 7,189 13,807 36.00 7,189 10,784 24,591 # Routing Invert Outlet Devices 1 Primary 33.00' 12.0" x 15.0' long Culvert RCP, square edge headwall, Ke= 0.500 Outlet Invert-- 28.50' S= 0.3000 7 n= 0.013 Cc-- 0.900 2 Device 1 33.00' 1.3" Vwt. Orifice/Gmie C= 0.600 3 Device 1 33.65' 10.0" Vert Orlfic afGrate C= 0.600 Primary OutFlow Max=1.67 des @ 12.46 hrs HW=34.44' (Free Discharge) t-1-CUI -ft (Pssses 1.67 cfs of 3.66 cfs potential flow) --2-0rifrcelGrate (Orifice Controls 0.05 cfs a 5.7 fps) L-3=0rifcafGrate (Orifice Controls 1.61 cfs @ 3.0 fps) Pond Cale Prepared by Wrightsville Engineering Services, PLLC HydroCAD® 7A0 sin 001707 01986-2003 Appled Microcom Type Ill 24-hr Rai►ftl=7.00" Page 5 Pond 2P: DWQ Pond Hydrograph 7. Inflow Area=1 A 00 ac Peak Elev=34.44' 5 Storage=13,365 cf 1 17.51 cis I 1 A7 cis 0 1 2 3 4 5 6 7 8 8 10 11 12 13 14 15 16 17 18 Time (hours) tr►Row Primary Pond Calcs Prepared by Wrightsville Engineering Services, PLLC HydroCADD 7.00 sln 001707 01986-2003 App&ed Microcoml Link 4L: Combined Type 11124-hr Rainfall=7.00" Page 6 Inflow Area = 1.500 ac, Inflow Depth = 3.26" Inflow - 2.13 cis @ 12.33 hrs, Volume= 0.408 of Primary = 2.13 cfs a 12.33 hrs, Volume= 0.408 af, Men= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-20.00 hrs, clt= 0.01 hrs Link 4L: Combined Hydrograph 2.13 cis 11 Inflow Area=1.500 ac 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time (hours) Irdlow Primary Drainage Ba nn 2P DWQ Pon Su [Reach] juj�k Zia - Combined 3S Areas Pond Calm Prepared by Wrightsville Engineering Services, PLLC HydroCAD07.00 s/n 001707 0198&2003 Applied Microcom Subcatchment 1S: Drainage Basin Type 11124-hr Rainfall=8.05" Page 2 Runoff = 8.72 cfs @ 12.07 hrs, Volume= 0.618 af, Depth= 6.74" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Type III 24-hr Rainfa11=8.05" Area (ac) CN Description 1.100 92 Urban commercial, 85% imp, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (M) (ft/sec) (cfs) 5.0 Dined Entry, Subcatchment 1S: Drainage Basin Hydrograph a- Type III 24-hr Rainfall=8.05" Runoff Area=1.100 ac Runoff Volume=0.618 of 5 Runoff Depth=6.74ae LL 4 Tc=5.0 min 3 - CN=92. 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time (hours) — Runoif Pond Calcs Prepared by Wrightsville Engineering Services, PLLC HydroCAD® 7.00 s/n 001707 01986-2003 Applied Microcom Subcatchment 3S: Uncollected Areas Type 11124-hr Rainfal1=8.05" Page 3 Runoff = 1.67 afs @ 12.08 hrs, Volume= 0.107 af, Depth= 3.21" Runoff by SCS TR-20 method, UH=SCS, Time Span-- 0.00-20.00 hrs, dt= 0.01 hrs Type ill 24-hr Rainfall=8.05" Area (ac) Chl Description 0.400 61 >75% Grass cover, Good, HSG B Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 5.0 Direct Entry, Subcatchment 3S: Uncollected Areas Hydrogmph 1.67 ds Type Ill 24-hr Rainfall=8.05" Runoff Area=0.400 ac Runoff Volume=0.107 of Runoff Depth=3.21 •• Tc=5.0 men C N=51 0 1 2 3 4 5 6 7 6 9 10 11 12 Time (hours) 16 17 1f! 16 71 — Runoff Pond Calm by Wrightsville Engineering Services, PLLC D 7.00 sin 001707 01986-2003 Applied Mcrocorr� Pond 2P: DMIQ Pond Type III 24-hr Rainfall=8.05" Page 4 Inflow Area = 1.100 ac, tnflow Depth = 6.74" Inflow = 8.72 cfs @ 12.07 hrs, Volume= 0.618 of Outflow = 2.12 cfs @ 12.44 hrs, Volume= 0.414 af, Atten= 76%, Lag= 22.0 min Primary = 2.12 cfs @ 12.44 hrs, Volume-- 0.414 of Routing by Stor-Ind method, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Peak Bev= 34.68' @ 12.44 hrs Surf.Area= 7,189 sf Storage= 15,123 cf Plug -Flow detention time= 180.3 min calculated for 0.414 of (67% of inflow) Center -of -Mass det. time= 108.4 min ( 848.0 - 739.6 ) # Invert Avail -Storage Storage Description 1 32.50' 24,591 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubicfeet) (cubic -feet) 32.50 6,047 0 0 33.50 7,189 6,618 6,618 34.50 7,189 7,189 13,807 36.00 7,189 10,784 24,591 # Routing Invert Outlet Devices 1 Primary 33.00' 12.0" x 15.0' long Culvert RCP, square edge headwall, Ke= 0.500 Outlet Invert= 28.50' S= 0.30007 n= 0.013 Cc-- 0.900 2 Device 1 33.00' 1.3" Vert Orifice/Grate C= 0.600 3 Device 1 33.65' 10.0" Vert Orifice/Gmte C= 0.600 Primary OutFlow Max=2.12 cfs @ 12.44 hrs HW=34.68' (Free Discharge) t-1=Ojsoe:t (Passca 2.12 cfs of 4.11 cfs potential flow) 1-2=0rifice/Grabe (Orifice Controls 0.06 cfs @ 6.1 fps) L--3=0r1f1cs/Grate (Orifice Controls 2.06 cfs Q 3.8 fps) Pond Calm Prepared by Wrightsville Engineering Services, PLLC Pond 2P: DM Pond Hydrograph Inflow Area=1,100 ac Peak Elev=34.68' Storage=15,123 cf 8.72 ds 2.12 ds Type W 24-hr RainfaN=&05" Page 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Tm* (hours) Inflow Primary Pond Cates Type 11124-hr Rainfall=8.05". Prepared by Wrightsville Engineering Services, PLLC Page 6 HvdroCAD® 7.00 afn OG1707 ® 49M-2CM Ann!PA RA#,mmmnthnr Cua4amc Link 4L: Combined Inflow Area = 1.500 ac, Inflow Depth = 4.17" Inflow = 3.08 cfs Q 12.11 hrs, Volume= 0.521 of Primary = 3.08 cfs @ 12.11 hrs, Volume-- 0.521 af, Men= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-20.00 hrs, dt-- 0.01 hrs Link 4L: Combined Hydrograph Inflow Area=1.500 ac 1-1 IUSdsI i z s 4 5 6 7 8 9 10 11 12 13 14 15 18 17 18 19 20 Tune (hours) trr Av Pd"Mry 1S Drainage Ba 'n 3S 2P Unco ected Areas DWQ Pon 4L Combined sub Reach on Link Pond Calcs Type 11124-hr Rainfall=10 00" Prepared by Wrightsville Engineering Services, PLLC Page 2 HydmCADS 7.00 s/n 001707 01986-2003 Applied Microcomputer Systems Link 4L: Combined Inflow Area = 1.500 ac, Inflow Depth = 5.88" Inflow = 4.57 cfs @ 12.09 hrs, Volume= 0.735 of Primary = 4.57 afs @ 12.09 hrs, Volume= 0.735 af, Men= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-20.00 hrs, dt= 0.01 hrs Link 4L: Combined Hydrograph In1bw Pnmary Inflow Area=1.500 ac 1 19 s 4 5 a 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time (hours) STORMWATER POND DESIGN POSTDEVELOPMENT RUNOFF RATES 2-YEAR 1-0-YEAR 25-YEAR 1 aQ-YEAR EROSION AND SEDIMENT CONTROL SPECIFICATION SECTION 02910 EROSION AND SEDmENT CONTROL PART 1 1.01 GENERAL: The Contractor shall maintain all work areas within and outside the project boundaries free from environmental pollution which would be in violation of any Federal, State or local regulations. 1.02 EROSION AND SEDEWENT CONTROL: All work shall comply with the regulations of the North Carolina Sedimentation Control Act of 1973. 1.03 DISTURBED AREAS: Sufficient erosion control practices must be installed and maintained to retain sediment within the boundaries of the site. All disturbed areas shall be non -erosive and stable within fifteen (15) working days or 90 calendar days whichever is shorter. All slopes, including ditches and stockpiles, must be stabilized within fifteen (15) days or thirty (30) calendar days whichever is shorter. 1.04 AREAS UNDER ACTIVE CONSTRUCTION: All erosion control devices shall be installed and maintained as required by the North Carolina Department of Environment, Health, and Natural Resources. Such measures may consist of berms, dikes, drains, and sediment basins, or use of fiber mats, woven plastic filter cloths, gravel, mulches, bituminous spray, and other erosion control devices or methods. Refer to drawings for minimum requirements for erosion and sediment control devices. PART 2 PRODUCTS 2.01 FERTELXFJNG AND SEEDING: Refer to drawings 2.02 SILT FENCE: Silt fence shall be used as a permeable barrier that retains sediment on the construction site. Use a synthetic filter fabric which is certified by the nianuflicturer or supplier conforming to the following requirements: Filtering efficiency - 85% minimum Tensile Strength of 20% maximum elongation 30 Ibs/lin in (min) Slurry Flow Rate - 0.3 gal/sq ft/min Installation and maintenance shall be by the manufacturers' recommendations. Materials shall meet the requirements of the North Carolina Department of Transportation. T-13-1 PART 3 AIR AND WATER QUALITY PROTECTION 3.01 PROTECTION OF AIR QUALITY: The air pollution likely to occur due to construction operations shall be minimized 'by wetting down bare soils during windy periods, requiring the use of properly operating combustion emission control devices on construction vehicles and equipment used by contractors, and by encouraging the shutdown of motorized equipment not actually in use. T rash burning will not be permitted on the construction site. 3.02 PROTECTION OF WATER QUALITY: The Contractor shall observe the rules and regulations of the State ofNorth Carolina and agencies of the United States Government prohibiting the pollution of stream or river waters by the dumping of any refuse, rubbish or debris therein. T-13-2