HomeMy WebLinkAboutNCC216732_Site Plan or Location Map_20211222111110111i
ASPHALT DRIVEWAY (PROFILE)
BRIDGE
BUILDING
CHECK DAM STD. 6.83
CONCRETE DRIVEWAY (PROFILE)
CURB & GUTTER
DITCH, CREEK OR BRANCH
--
EDGE OF PAVEMENT
EXISTING FIRE HYDRANT
FH
EXISTING GAS MAIN
G
EXISTING GAS SERVICE
GS
EXISTING IRON PIN
0
EXISTING 1 SANITARY SEWER
SS
EXISTING SANITARY SEWER MANHOLE
C1
EXISTING �_ WATER MAIN
W
EXISTING WATER OR SANITARY SEWER R/W
EXISTING WATER SERVICE
Ws -
EXISTING WATER VALVE
I><
FENCE (LABEL TYPE)
X X X-
GAS VALVE
a
GRAVEL DRIVEWAY (PROFILE)
GROUND (PROFILE)
GUARD RAIL
T T T T ,
MARSH
ali, ali,
OVERHEAD ELECTRIC
OHE
PIERS
POWER POLE W/GUY WIRE
0
PROPERTY LINE
-R-
PROPOSED AIR RELEASE VALVE
PROPOSED FIRE HYDRANT
PROPOSED q SANITARY SEWER
PROPOSED SANITARY SEWER MANHOLE
•
PROPOSED CL WATER MAIN (MARKED EVERY 100')
1
PROPOSED WATER METER LOCATION
PROPOSED SANITARY SEWER EASEMENT
SSE
TEMPORARY CONSTRUCTION EASEMENT
e
PROPOSED WATER VALVE
►�
RAILROAD
RIP - RAP
ROAD/STREET RIGHT-OF-WAY
—RfW
SEDIMENT FENCE (SILT FENCE) STD. 6.62
■
SIDEWALK
SIDEWALK
STORM DRAIN WITH CATCH BASIN OR DROP INLET —
STREET SIGN
�-
TEMPORARY DIVERSION STD. 6.20
TD — TD — TD
TEMPORARY SEDIMENT TRAP STD. 6.60
TEMPORARY STREAM CROSSING STD. 1
�T�
TOWER LINE
------
TREE
0
UNDERGROUND CABLE
uc
UNDERGROUND ELECTRIC
UE
UNDERGROUND TELEPHONE
UT
UNDERGROUND TELEVISION CABLE
TV
WATER METER
11 WM
WATER VALVE
WV
M
THE TOTAL DISTURBED AREA FOR THIS PROJECT IS 3.05 ACRES.
AN EROSION CONTROL PERMIT IS REQUIRED.
DESIGN COMPANY: FRAZIER ENGINEERING, P.A.
PLANS PREPARED BY: MARK E. LAMBERT, P.E.
ADDRESS: 6592 BOB WHITE TRAIL, STANLEY, NC 28164
PHONE: (704)-822-8444
DATE DESIGN COMPLETED: JULY 2018
SURVEY COMPANY: SURVEY AND MAPPING CONTROL
SURVEYED BY: TONY B. SANDERS
ADDRESS: 12727 DORMAN ROAD, PINEVILLE, NC 28164
PHONE: (704) 542-9095
DATE SURVEY COMPLETED: JUNE 2018
DEVELOPER: -
ADDRESS: -
PHONE: CONTRACTOR: -
ADDRESS: -
PHONE: -
INSPECTOR: FRAZIER ENGINEERING, P.A.
INSIDE CHARLOTTE: (✓) YES ( ) NO:
TOPO NO: 72/109
Creek line type
shown on the
plans
CHARLOTTE
%fV Im E Ft
CHARLOTTE, NORTH CAROLINA
SANITARY SEWERAGE SYSTEM IMPROVEMENTS
INDEX OF SHEETS
SHEET
NO.
1
COVER SHEET
SHEET
NO.
2
STA. 0+00 TO STA. 10+50
SHEET
NO.
3
STA. 10+50 TO STA. 21+50
SHEET
NO.
4
STA. 21+50 TO STA. 30+47.68
SHEET
NO.
5
"A" STA. 0+00 TO STA. 0+63.29
"B" STA. 0+00 TO STA. 0+48.04
"C" STA. 0+00 TO STA. 0+34.62
SHEET
NO.
6
STANDARD DETAILS
SHEET
NO.
7
STANDARD DETAILS
SHEET
NO.
8
STANDARD DETAILS
APPLICATION FOR NON -DISCHARGE PERMIT
GRAVITY SEWER MAIN EXTENSION
CHARLOTTE WATER
PROJECT NAME
UPPER LITTLE SUGAR CREEK REPLACEMENT CREEK BASIN UPPER LITTLE SUGAR
SEWER PHASE 2 FROM BILMARK AVENUE TO GEORGETOWN DRIVE
CLTWater PROJECT NO.: 7030250014-16-600
PROJECTTYPE: ❑NEW CONSTRUCTION XRELOCATION ❑MODIFICATION OF PERMIT NO.
OTHER
VOLUME OF WASTEWATER GENERATED BY THIS PROJECT: 0 GALLONS PER DAY BASED
ON 190 GAL/DAY/SINGLE FAMILY HOUSEHOLD X HOUSEHOLDS OR
135 GAL/DAY/MULTI-FAMILY UNIT X UNITS OR IS BASED ON:
WASTEWATER TREATMENT PLANT RECEIVING WASTEWATER:
❑ McALPINE CR. (NCO024970) ❑ IRWIN CR. (NCO024945) ❑ McDOWELL CR. (NCO036277)
X SUGAR CR. (NCO024937) ❑ MALLARD CR. (NCO030210) ❑ ROCKY CR. (NCO036269)
NATURE OF WASTEWATER 100 % DOMESTIC % INDUSTRIAL
T U"�'R E E K %COMMERCIAL %OTHER
UPPER LITTLE SUko- AR REPLAU'O�EMENT
ORIGIN OF WASTEWATER ❑ SUBDIVISION ❑ COMMERCIAL
❑ SCHOOL ❑ INDUSTRIAL
❑ APARTMENTS/CONDO'S X OTHER VARIOUS ESTABLISHED CUSTOMERS
SEWER PHASE 2 FRU`O�M BILMARK AVENUELIST ANY PARAMETER AND ITS CONCENTRATION THAT WILL BE GREATER THAN NORMAL DOMESTIC LEVELS:
NONE
ARTWIN RD
a
S�"��
�O
d
Z
0
= Z
d vA
DR
d
S
CANSERW0�D
Z
� 0
f10T
v,
CT
v
L Z
�Fo
�CFT
ow
N ��
RD
DR
B�ACKHAWK
A
DERRYD�WNE
�GP
�
LANE
U
�
z J
J
W ARRO
HUGHES DR
J � A
w �
m
z
SN❑ WHITE LN z
z
J
Q
Z
J
0
O
3
LD
W
�
ca
z z
3 o
W
q
PHASE 2
o
U
A
VICINITY MAP
NOT TO SCALE
OOO
CALL NC ONECALL\
BEFORE YOU DIG
STOP
1-800-632-4949
,AVOID UTILITY DAMAGE,
IF WASTEWATER IS NON -DOMESTIC, DESCRIBE LEVEL OF PRETREATMENT:
N/A
IF A PRETREATMENT PERMIT IS REQUIRED, HAS ONE BEEN ISSUED? ❑YES ❑ NO
HAS ENGINEER DETERMINED THAT DOWNSTREAM SEWERS ARE CAPABLE TO HANDLE THIS FLOW? X YES ❑ NO
PERMIT NO. FOR SEWERS IMMEDIATELY DOWNSTREAM NOTAVAILABLE
PIPE DIAMETER OF SEWERS IMMEDIATELY DOWNSTREAM 18 INCH
HAS ENGINEER DETERMINED THAT NC DEM AND CLTWater MINIMUM DESIGN STANDARDS ARE MET BY THIS
PROJECT? RYES ❑ NO
COMPLETE NAME AND ADDRESS OF ENGINEERING DESIGN FIRM:
FRAZIER ENGINEERING, P.A.
6592 BOB WHITE TRAIL
STANLEY, NC 28164
TELEPHONE 704 822 8444
PROFESSIONAL ENGINEER'S CERTIFICATION:
I, MARK E. LAMBERT ATTEST THAT THIS APPLICATION FOR UPPER LITTLE SUGAR CREEK
REPLACEMENT SEWER PHASE 2 FROM BILMARK AVENUE TO GEORGETOWN DRIVE
HAS BEEN REVIEWED BY ME AND IS ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. I FURTHER ATTEST
THAT TO THE BEST OF MY KNOWLEDGE THE PROPOSED DESIGN HAS BEEN PREPARED IN ACCORDANCE WITH THE
APPLICABLE REGULATIONS. ALTHOUGH CERTAIN PORTIONS OF THIS SUBMITTAL PACKAGE MAY HAVE BEEN DEVELOPED
BY OTHER PROFESSIONALS, INCLUSION OF THESE MATERIALS UNDER MY SIGNATURE AND SEAL SIGNIFIES THAT I HAVE
REVIEWED THIS MATERIAL AND HAVE JUDGED IT TO BE CONSISTENT WITH THE PROPOSED DESIGN.
NORTH CAROLINA PROFESSIONAL ENGINEER'S SEAL, SIGNATURE, AND DATE
p�' �N\A CAR0<i
C4,
�`�o,s�tiOfESS%p.U°•�'/i�i
'',''z/%// llillllll M�``````
CLTWater PERMIT NO.
PLANT FLOW ALLOCATION RECORDED BY:
PERMIT APPROVED BY:
NOTES:
1) CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHARLOTTE
WATER STANDARD SPECIFICATIONS.
2) THE CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION.
3) ALL SHORING SHALL BE IN ACCORDANCE TO OSHA TRENCHING
STANDARDS PART 1926, SUBPART P, AS AMENDED TO DATE.
4) ANY NECESSARY LANE CLOSURES SHALL FOLLOW GUIDELINES
OUTLINED IN THE MANUAL OF UNIFORM TRAFFIC CONTROL
DEVICES AND/OR C.D.O.T. WORK AREA TRAFFIC CONTROL
HANDBOOK. (WATCH)
5) IF THE PROPOSED SEWER MAIN IS INSTALLED WITHIN 12" IN ANY
DIRECTION (VERTICALLY OR HORIZONTALLY) FROM A GAS MAIN,
THEN THE CONTRACTOR SHALL CALL THE APPROPRIATE GAS
COMPANY AND INFORM THEM.
6) MINIMUM PIPE SEPARATION: 10 FEET HORIZONTAL SEPARATION
OR 18" VERTICAL SEPARATION SHALL BE MAINTAINED BETWEEN
WATER MAINS OVER SEWER MAINS. WHEN WATER MAINS ARE
BELOW SEWER MAINS OR THE ABOVE MINIMUM SEPARATIONS
CANNOT BE MAINTAINED, DUCTILE IRON PIPE SHALL BE USED
FOR BOTH MAINS TO 10 FEET EITHER SIDE OF CROSSINGS, AND
ALL ALONG THE LENGTH OF MAINS WHERE MINIMUM SEPARATION
CANNOT BE MAINTAINED.
7) THE CONTRACTOR SHALL SEED AND MULCH AT THE END OF
EACH DAY.
8) RIGHT—OF—WAY USE PERMIT AND STREET CUT PERMIT:
PRIOR TO PERFORMING WORK IN A CITY OF CHARLOTTE
MAINTAINED ROAD RIGHT—OF—WAY THE CONTRACTOR IS
RESPONSIBLE FOR NOTIFYING CDOT AT LEAST 5 DAYS IN
ADVANCE OF WORK. CONTACT BOB STALEY, CHARLOTTE
DEPARTMENT OF TRANSPORTATION BY FAX AT
704-336-4400. THE FAX SHALL INCLUDE TIME AND DATE OF
CONSTRUCTION AND REFERENCE THE APPROPRIATE LANE
CLOSURE DIAGRAM FROM THE "WATCH" MANUAL.
AFTER RECEIPT OF THE RIGHT—OF—WAY USE PERMIT,
CONTACT STREET CUT PERMITS AT TELEPHONE
704-336-4025 FOR APPROVAL TO OPEN CUT STREETS OR
SIDEWALKS. COPIES OF THE PERMITS SHALL BE PROVIDED TO
THE INSPECTOR PRIOR TO CONSTRUCTION AND SHALL BE
DISPLAYED AT THE JOB SITE.
9) THE CONTRACTOR MUST OBTAIN A COPY OF THE LATEST
REVISION OF THE "CDOT STREET MAINTENANCE DIVISION,
REGULATIONS AND FEE SCHEDULE, PROCEDURES FOR WORKING
IN ASPHALT AND CONCRETE PAVEMENTS" AND MAINTAIN IN
THEIR POSSESSION AT ALL TIMES WHEN WORKING IN ANY
CDOT RIGHT—OF—WAY.
ISSUED
JOSEPH C WILSON, P.E., CHIEF ENGINEER
APPROVALS (SEALS)
N.C.R.L.S. (AS BUILT)
`\,`` \11111111 RO
�``o° '6f E S%p� �9 Kv
i
ESES AL/ -
2206J
N.C.P.E.
SUMMARY OF SEWER
MAINS & MANHOLES
SIZE
LENGTH
SIZE
LENGTH
18 INCH
3,047.68
8INCH
145.95
TOTAL NO. OF
MANHOLES: 21
TOTAL NO. LOTS SERVED: N/A
PROJECT NAME: UPPER LITTLE SUGAR CREEK REPLACEMENT
SEWER PHASE 2 FROM BILMARK AVENUE TO GEORGETOWN DRIVE
JOB NO: 7030250014-17-510
DATE OF ACTIVATION:
DATE AS BUILT: BY-
9
A CITY OF CHARLOTTE DEPARTMENT