Loading...
HomeMy WebLinkAboutNCG550800_NOV-2021-PC-0289_20210524pocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA ROY COOPER Governor DIONNE DELLI-GATTI Secretory S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality May 24, 2021 CERTIFIED MAIL # 7017 2680 0000 2219 5633 RETURN RECEIPT REQUESTED Hubert L. Riley 2117 Shaw Road Durham, NC 27704 Subject: NOTICE OF VIOLATION Tracking Number: NOV-2021-PC-0289 Compliance Evaluation Inspection Single Family Wastewater Treatment System NPDES General Permit NCG550000 Certificate of Coverage NCG550800 Facility Name: 2432 Redwood Road Durham County Dear Hubert Riley, On April 29, 2021 Chris Smith from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the subject General NPDES Permit. No one was at home at the time of the inspection. Our records indicate the treatment system consists of a septic tank, sub -surface sand filter, tablet chlorinator with chlorine contact chamber, discharge pipe and a rip -rap apron for post aeration. General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550800 authorize the discharge of domestic wastewater from your treatment system to receiving waters designated as an unnamed tributary to Panther Creek classified Water Supply (WS-IV) and Nutrient Sensitive Water (NSW) in the Neuse River Basin. The authorized discharge is in accordance with the effluent limits and monitoring requirements established within the General Permit. The items below show what conditions were noted at your facility: Findings during the inspection were as follows: 1. Treatment system operation: The wastewater treatment system shall be maintained at all times to prevent seepage of sewage to the surface of the ground. 2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than ,eD_EQ� oeweeean m Unicannergal Met\ North Carolina Department of Environmental Quality ' Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA Hubert L. Riley, NCG550800 May 24, 2021 Page 2 of 3 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. Within 30-days of receiving this letter, please send a copy of the most recent receipt/invoice to this office showing the date the septic tank was last checked and/or pumped out. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. During the inspection the presence of solids on and around the lid of the septic tank was observed inside the access riser. This may indicate that the system is not functioning properly and is causing the septic tank to overflow. 3. Disinfection: Your system is lacking disinfection, either chlorine tablets or a UV light system. New rules put into place on August 1, 2007 require all SFR systems to have a means of disinfection. Since your system had no disinfection, the installation is to include a chlorine tablet dispenser, a contact chamber capable of providing a minimum 30-minute contact time, Within 30-days of receiving this letter, please send a schedule to this office that states your plan for correcting this deficiency. During the inspection the existing chlorinator could not be located and may have been removed and/or damaged during grading work that appears to have been conducted on the property. 4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform and Total Residual Chlorine. Within 30-days of receiving this letter, please let this office know if you have monitored your effluent discharge within the last 12 months and provide this office with a copy of the lab results if you have. If you have not monitored your effluent, then please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than August 16, 2021. If, during this time, you are unable to collect a representative sample of the effluent discharge due to insufficient flow from the discharge pipe, then update this office with that information and continue to monitor the discharge and if conditions for sampling become favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 5. Locations of treatment units are unknown: Within 30-days of receiving this letter, provide this office with a sketch or map of the location of the treatment units (sand filter, chlorinator, contact chamber) in relation to the permitted residence. 6. Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The end of discharge pipe was not visible nor accessible the day of the inspection. To comply with the general permit monitoring requirements, you need to be able to sample and analyze the effluent from your SFR system through the discharge rr,Iar� Q ow.,ernn m En.wo....rn auut,�r/ North Carolina Department of Environmental Quality . Division of Water Resources Raleigh Regional Office 3800 Barrett Drive : Raleigh. North Carolina 27609 919 791.4200 DocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA Hubert L. Riley, NCG550800 May 24, 2021 Page 3 of 3 pipe. You need to keep the area around the discharge pipe cleared of vegetation, soil and leaves. Please take the necessary steps to ensure the discharge outlet is visible and accessible. Maintaining the area will allow you to monitor the discharge and to collect effluent samples as required by the subject permit. Part II Section B.14 of General Permit NCG550000 requires the permittee to "pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division. Division records indicate the required annual fee ($60 per year) for the period ending 09/30/2021 and due 10/02/2020, has been paid. There are no overdue fees for the subject COC. The wastewater treatment system should be periodically inspected to ensure the treatment components are always maintained and in good operating order. You are also reminded to maintain all monitoring data and associated maintenance records onsite for a minimum of three years and available for inspection. This inspection report is being issued as a Notice of Violation because there is currently no chlorinator installed, no septic tank maintenance records, no effluent analysis records, and the outfall could not be located. Within 30-days receipt of this letter, please submit a written response to this office indicating the actions you will take or have taken to comply with or resolve the issues noted in items 2-7 above. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Chris Smith at 919-791-4257 Sincerely, DocuSigned by: L1ttssa f. Aitzunitd, B2916E6AB32144F.,. Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): EPA Water Compliance Inspection Report Cc: RRO/SWP Files Laserfiche f.311D of EmYonofnW Oua: North Carolina Department of Environmental Quality 1 Division of Water Resources Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA United States Environmental Protection Agency E PA Washington, D C 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 Li 3 1 NCG550800 111 121 21/04/29 11718 [j 1912] 201 9 I I I I I I I I I I I i i i I I I I I I I I I I I I I ( I I I I I I I I i i i 1 r6 Inspection Work Days Facility Self -Monitoring 671 I 70I Evaluation Rating B1 QA I 711 I 72 I N I 731 I I I Reserved 174 7511 I I I 1 I I 180 I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 2432 Redwood Road 2432 Redwood Rd Durham NC 27704 Entry Time/Date 11:OOAM 21/04/29 Permit Effective Date 20/04/14 Exit Time/Date 11:15AM 21/04/29 Permit Expiration Date 20/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Hubert L Riley,2117 Shaw Rd Durham NC 27704/// No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) ® Permit II Operations & Maintenar 11 Records/Reports • Sludge Handling Dispot 11 Facility Site Review Effluent/Receiving Wate Laboratory 11 Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Chris Smith Inspector(s) Agency/Office/Phone and Fax Numbers Date Docusignedby: DWR/RRO WQ/919-791-4200/ r,LViS S14.4 S/24/2021 C 1D4270C0D8E94E9 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date r—DocuSigned by: Valet-SSa f. it' 6/1/2021 EPA F916E6AB3 144F orm 35620-3 (Rev 9-94) Previous editions are obsolete. Page# 1 DocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA 3( NPDES NCG550800 111 121 yr/mo/day 21/04/29 117 Inspection Type 18 Li, (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Mobile home appears to be unoccupied at the time of the inspection. Some grading work has been done behind the dwelling and potentially over the sand filter. The chlorinator that appears to have been present during past inspections is not locatable and may have been damaged/removed during grading work. Inspector was unable to locate outfall. Solids were present on top of and around the cement lid o the septic tank inside the access riser. It is not known if the solids are waste or infiltrated soil, but may be due to damaged sandfilter, chlorinator, outfall pipe, or some or all of the above. Page# 2 DocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA Permit: NCG550800 Inspection Date: 04/29/2021 Owner - Facility: 2432 Redwood Road Inspection Type: Compliance Evaluation Other Yes No NA NE Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Newer permit has not been issued. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Solids may be backing up into the septic tank. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Could not locate outfall. Septic Tank (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Comment: Last septic tank cleanout not known. Sand Filters (Low rate) (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Yes No NA NE ❑ ❑ ❑ • ❑ ® ❑ ❑ O E OD ❑ ❑ • ❑ 11 ❑ ❑ ❑ Yes No NA NE ❑ ® ❑ ❑ ❑ ❑ • ❑ Yes No NA NE ❑ ❑ ❑ O D OD DDD Yes No NA NE ❑ ❑• ❑ ❑ ❑ ❑ • ❑ ❑ ® ❑ ❑ ❑ ■ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ • 11 ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: FF086CBC-6E13-43AB-8F64-39463B8EADEA Permit: NCG550800 Inspection Date: 04/29/2021 Owner - Facility: 2432 Redwood Road Inspection Type: Compliance Evaluation Sand Filters (Low rate) Is the sand filter effluent re -circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) Comment: Yes No NA NE ❑ ❑ ® ❑ ❑ ❑ • ❑ ❑ ❑ ® ❑ Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ❑ ❑ ❑ El Are all other parameters(excluding field parameters) performed by a certified lab? 0 0 ❑ a # Is the facility using a contract lab? ❑ 0 0 0 # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 0 ❑ 0 Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? 0 0 0 El Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? 0 0 ❑ Comment: Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Unable to locate chlorinator. Yes No NA NE DDD ❑ ❑ ❑ El ❑ ❑ ❑ it ❑ ❑ ❑ 1611 ❑ ❑ ❑ B Page# 4 Inspection Date: 47' 2_41• 2-021 Start Time: ) [ (:5C)<A-"--A- End Time: (t 15 G• - SlNGLE FAMILY WASTEWATER SYSTEM CHECKLIST Permitcea. 010-w-t' 'Rikq pE,— . NG `�s-so V O Address: 24132- R ,,...)oO_2o,..a- E-m aii- . ?hone:(_glel_r-_G 7Z 20Z3 . ' Cell Ph n.s.� ..J _....._� County: -Dv c kUv,N. The P+�Peer'7it�e isar'..f.: rslb;•e for iln l_ e i ;1:: X rarrasaaaaraaaaaaaa.... m. ..r.,.... ._.v__..�. .� ..a.....�:�_.s��-„�-_..s-�....,.,....van..wa,.r'.n......_�....'.'.�..�.,_.��.�..�..�. ,'.�. is •: :i s) system. Doesn't�Dicl Not" 1. Is tire current r sii' nt In tie horns the Pemlitiec i 7. If notd7'es the re..'ien`: rent from tile prrni t. ? 33. Chann;_ of Ownership fcirn ne :dd? (mail t'n.z.re a inspection and maintenance ._ il.F'; J. If y' s to..'! who is t:le corit:Jrci:r? �•:_ NO Apply I n`i_., is •_ SEPTK,'TANK Ti:._-a:_....,and ri:_... , _...._. :: :- r: ..._._...;..... . 1.7i:5st Y'Urnp J In tim.. 12st yez...52 1'7.) [.7•.1 �., t i'.' s otic .-r. EFFLUENT FIL i ,'i 11. If Yes to fi!to: vi•i sn Yiasth f'!' clean.__.? .3 I. iil .5t :'r'r `.. _. u.. h.o n.. r'iaii... ..,:.i tJ SA''IO FIi_ T ER / TRrATI'AENT PODS YES 12 1_ _j_t :7i SJ!':.: ita rJ othar than Sandi. R-I! 13 I; yes. w,f:_.. F: (_... rr : - Peet, T E..'`.`.,- , !� t�i_7. lid.. �'.i..'il:�. r-•;:{i'r r%.. r��il J'i l!:''. DISI4NF±' C i in •t i 1_1''. Y S .I i• DISINFECTION 'TAEi .ITS .'E5 Ltd •'..�., tiiS. Ir-;Iri. Ct'i. _, f.{'•. •! :)Il .__.._.:`J� :r.� ;t7.':): ?.!. =•r. ��r i . ' _ /nt s :1:J';V' o i` Cy�= r: p;ri;L .... . ECi LOR (Dis c'narg only) ES_. 23, I errmi'tte . 7 t1 r 1;;I s , t�. : U��_ i �- ?;'�- :;_:'i:.. !ice �=t,'I•a;: ? S. !�!' r -' , ' t 1 �1==.:;�_r...,...it G�_i_�i`r`�; i�; 26. Ark I:_`.S contacting `!`r t i J i; poo; h'. t':71.o ti ` ,_ ._ :.C1,'1`r • NC.-; '- \ l%h \ \.ta vJ .. _ ; 0 .` X r,c7 [.a no prc_a_ci •, t. ;,V< ... pr:ceact tott1i n ! '_ton. 1 1- PUMP TANK YES r7 All pump and alarm stems shall be inspected monthly (non•d stharge) 27. Is the pump working? 23. Are theaudible and visual high water alarms operational? 29. Does the permittee know how to check the pump & high water alarm? 30. Last functional test: PUMP AUDIBLE & VISUAL DISCHARGE ONLY YES [J NO If no proceed to the next section. A visual review of the oi. ttall loca`.'on shall be executed t.vce each year (.ae at the time of ssmplirg to ensure no visible solids or e rdence of a malfunction i1 Doesn't Did Not Yes No Apply Investigate NO If no proceed to the next section. ❑ ❑ 31. Does the permittee know where the outfall is located? 32. Were you able to locate the outfall? 33. Is the end of the discharge pipe visible and 34. Is outlet discharging? 35 Is right of way m=inteined around the discharge point? 3o Any Lab Results available? 37. is there evidence of solids around the discharge point? 11 1 •If no proceed to the next section. 'he irr'galion system shall be inspected monthly to ensure. the system is f:» ref teal...3 and e.urpment Is operating a des:cned. 18. Is the system DRIP or IRRIGATION (circle one)? If irrigation number of sprinkler heads 39. Are the buffers adequate? • 1 40. Is the site free of ponding and runoff? U 41. Does the application equipment appear to be .',o-H ing prooerlJ? j J i wire fence i u -� e e ir; g ti,Dn ea J I 1 }_- Is therea minimum two �. s�rre nd r� ._ lire ,.,_ a _ El 1 1 ❑ 1 1 1 1 ❑ 11 n 1 1 ■ ❑ ❑ GENERAL ------ ---- 43. Are the treatment units locked and or secured? ❑ 44 Has resident had any sewage problems? if 1_s e;pta:r, ir tr_ ccr:.-lert s._t•on. Lei 45 Dces the system match the permit description? I' ,, _ �.1a n •r.. r _ c_nrcr' _ec:ion 1 1 ,- I 1 :S Is the system compliant? 47. Is the system failing? If yes. taxes p,cb_r_s if pcs_ tie ❑ _ - 48. If system is failing. an/ sign of children or animals cor actinlog se.vsge'? NOD Sent#.-: - - - NOV Sent '.. - .A. --- - 1�"I 1 1 l1 l>,' r 1 I I - - -_. 1 1 1 1 [—I Li Fl l 1 _. 11 1 tJ 1 1 1'1 r-�.� U I,--; --- Comments: Pnotcs Ta!< en? YES (_--i NO II 1 } Cif\ \� v t ,. c —Mr' `D1J CO( \I� A- - , 5j e,;,.1 e may-, •• w Y �� J L ] •Z.'CVL C `11'e i \ J �� O r 1 ✓� ..• 1 ,- yvN-Lk. � W.,:'e. -e. a./•,.n . j-C. • • �IJCO �r 3C d �'�rs/\ �� L �t (7 C {C �.\G•n.- C A `fir• yam. 4�J • 1`01-/�,i/ ' U J- V k l. 1 Tr c- ct,M / / l`j INSPECTOR: C �1 `- ` .'1 , ` SIGNATURE: MAA