Loading...
HomeMy WebLinkAboutWQ0043063_Application (FTSE)_20211220Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 828.281.3350 Transmittal 4) ANCHOR QEA December 15, 2021 To: NCDEQ Division of Water Resources Asheville Regional Office 2090 US 70 Highway Swannanoa, NC 28778 From: Robert Cork Anchor QEA of North Carolina, PLLC Cc: Ken Kramer, Givens Highland Farms Alexandra Baratucci, Anchor QEA of North Carolina, PLLC Re: Fast Track Sewer System Extension Permit Application Givens Highland Farms — Campus Redevelopment Phase 2 Black Mountain, Buncombe County, North Carolina Copies Description 2 Original and one copy of permit application submittal 1 Application Fee ($480) 3°17211 DEC 1 6 2021 Water Quality Regional Operations Asheville Regional Office Fast Track Transmittal CoverFast Track Transmittal-Cover.docx Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 828.281.3350 North Carolina Department of Environmental Quality Division of Water Resources Asheville Regional Office Water Quality Section 2090 US Highway 70 Swannanoa, North Carolina 28778-8211 Re: Givens Highland Farms — Campus Redevelopment Phase 2 Fast Track Sewer System Extension Permit Application To Whom It May Concern, ANCHOR QEA December 13, 2021 Water Quality Regional Operations Asheville Regional Office The purpose of this letter is to fulfill the requirements stated by the North Carolina Department of Environmental Quality (DEQ) for the approval of an extension of the sanitary sewer system. On behalf of Givens Highland Farms (Givens), Anchor QEA of NC, PLLC (Anchor QEA) is hereby submitting a Fast -Track Extension application. Givens, under the design and planning guidance of Anchor QEA and others, is preparing a redevelopment project which requires the extension of the sanitary sewer system to an expanded and rebuilt subdivision. Project Purpose and Name The proposed project, called Campus Redevelopment Phase 2, is located on the campus of Given Highland Farms off North Rim Road, Wagon Trail, and Brookside Drive in Black Mountain, NC 28711. The plat number is 134-147 and the property PIN number 0609-55-1146. This project intends to demolish existing buildings on the campus, to be rebuilt with new apartments and new common activity areas for the residents. Due to the installation of new apartments, an extension to the water main and connection to the new buildings is required. The extension will be to an existing private system for service to an additional 36 residential apartments and condominiums, producing a total wastewater flow of 9,500 gallons per day (GPD). This 9,500 GPD is an additional demand of 3,500 GPD to the sewer system compared to the previous buildings. The additional demand of 3,500 GPD has been approved by Metropolitan Sewerage District; this can be confirmed by the Flow Track Acceptance Form included as Attachment 2. The proposed sewer extension will consist of the installation of approximately 756 linear feet of standard dimension ratio (SDR) 35 polyvinyl chloride (PVC) pipe, 5 manholes, and 2 service connections. Previous development was permitted by the Division of Water Quality to Givens Estates under Permit No. WQ0022578. All requirements and specifications allowed under this permit shall be maintained. December 13, 2021 Page 2 This project intends to add to the existing private sewer system, with a tap into Existing Manhole (EMH) MSD #30-24327, plug and demolish EMH MSSD #30-24328, and install a manhole to cut into the existing line. Enclosures Enclosed with this letter is the check for $480.00 and the forms and attachments which meets DEQ's requirements, as necessary to complete the review and process the sewer extension permit application. Givens and Anchor QEA realizes that this is a non-refundable fee used to cover the costs of various field studies and staff time required to process the application and cannot be used as a credit against any other costs incurred. We anticipate needing the sewer extension for the above stated purpose to be authorized by January 31, 2022. This date is the anticipated start of construction date. Should DEQ require more information or have any further questions, please do not hesitate to contact Robert Cork at 828-771-0370 or via email at rcork@anchorqea.com, or Alexandra Baratucci at 828-641-9322 or via email at abaratucci@anchorgea.com. We look forward to receiving approval of the permit from DEQ. Sincerely, Robert Cork, P.E. MEng cc: Ken Kramer of Givens Highland Farms, Inc. Walter Dinicola of Anchor QEA Alexandra Baratucci of Anchor QEA Attachments Figure 1 Attachment 1 Attachment 2 Attachment 3 Attachment 4 Attachment 5 Project Location Map NCDEQ Fast Track Sewer System Extension Application Form FTA 06-21 Flow Tracking / Acceptance Form FTSE 10-18 and Approval from MSD Developer Operational Agreement Existing Permit No. WO0022578 Check in the Amount of $480.00 nl \\6 ' Y DEC 1 b 2021 DW lir Quality Operations State of North Carolina Department of Environmental Quality Division of Water Resources Asheville Regional Office FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria (Gravity Sewer & Pump Stations/Force Mains) and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T, 15A NCAC 02T .0300, Division policies, and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that do not meet any part of the minimum design criteria (MDC) documents; ➢ Projects that involve more than one variance from the requirements of 15A NCAC 02T; ➢ Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPs) or simplex grinder pumps; ➢ Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents ® Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ Include the permit number/status of any other required sewer permits (downstream/upstream) ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Modification Application Packages): ® Submit a check or money order in the amount of $480.00, dated no more than 90 days prior to application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 05-21): ® Submit the completed and appropriately executed application. D. If necessary for clarity or due to space restrictions, attachments to the application may be made. E If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. p If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. • The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and forni FTSE indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area, including the closest surface waters. ➢ General location of the project components (gravity sewer, pump stations, & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include an aerial location map showing general project area (such as street names or latitude/longitude) so that Division staff can easily locate it in the field. G. Existing Permit (Application Packages for Modifications to an Existing Permit): ® Submit a copy of the most recently issued existing permit. ® Include a descriptive and clear narrative identifying the previously permitted items to remain in the permit, items to be added, and/or items to be modified (the application form itself should include only include items to be added/modified). The narrative should also include whether any previously permitted items have been certified. ® The narrative should clearly identify the requested permitting action and accurately describe the sewers to be listed in the final permit. H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): El Per 15A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Propertv Owners' Associations ❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM: HOA). O Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ® Developers of lots to be sold O Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For more information visit the Division 's collection systems website INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778-8211 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5095 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Water Quality Section Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609 (919) 791-4200 (919) 571-4718 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Water Quality Section Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Water Quality Section Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 (336) 776-9797 Fax Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin Water Quality Section INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 3 of 3 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Givens Highland Fanns (company, municipality, HOA, utility, etc.) 2. Applicant type: ['Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ['Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Ken Kramer per 15A NCAC 02T .0106(b) Title: Executive Manager 4. Applicant's mailing address: 200 Tabernacle Road City: Black Mountain State: North Carolina Zip: 28711-7733 5. Applicant's contact information: Phone number: (828) 357-3606 Email Address: kkramer( givenshighlandfarms ❑ Other IL PROJECT INFORMATION: 1. Project name: Givens Highland Farms Campus Redevelopment Phase 2 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0022578 and issued date: June 5, 2003, For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Buncombe 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.614889 ° Longitude:-82.348757° 5. Parcel ID (if applicable): 0609-55-1146 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Walter Dinicola License Number: 044681 Firm: Anchor QEA of North Carolina, PLLC Mailing address: 231 Haywood Street City: Asheville State: North Carolina Zip: 28801- Phone number: (410) 794-7783 Email Address: wdinicola@anchorqea.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: MSD of Buncombe County Permit Number: NC0024911 Owner Name: Metropolitan Sewerage District V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Givens Highland Farms FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ® Yes ❑ No ❑ N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ® Residential (Leased) ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ® Food and drink facilities ❑ Church ❑ Businesses / offices / factories ® Nursing Horne ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool/Clubhouse ❑ Swimming Pool/Filter Backwash El Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Dwelling/ Residential Areas (66 from 30 units, 95 from 60 bedrooms) 100 gal/unit 95 9,500 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 9,500 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 3,500 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ® Flow has already been allocated in Pennit Number: W00022578 Issuance Date: June 2003 ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) 8 756 Material SDR35 ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - . ° 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (fine capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C. I .b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ D. Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)? ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ® Yes ❑ No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ®No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: I, Walter Dinicola , attest that this application for Givens Highland Farms Campus Redevelopment Phase 2 (Professional Engineer's name from Application Item III.1.) (Project Name from Application Item II.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: Walter Dinicola 3. Applicant's Certification per 15A NCAC 02T .0106(b): Digitally signed by Walter Dinicola Date: 2021.12.13 16:23:28 -05'00' I, Ken Kramer , attest that this application for Givens Highland Farms Campus Redevelopment Phase 2 (Signature Authority Name from Application Item I.3.) (Project Name from Application Item II.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 06-21 Page 5 of 5 X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force ivlains (latest versionj, and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ®Yes El No if no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. Professional Engineer's Certification: 1, Walter Dinicola , attest that this application for Givens Highland Farms Campus Redevelopment Phase 2 (Professional Engineer's name from Application Item 111.1.) (Project Name from Application item 11. I) has been reviewed by me and is accurate, complete and consistent with the information supplied ht the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version), Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: Walter 1 Digitally signed by ,\Walter Dlnlcola Iinicola.. Date:2021.12.13 16:23:28 -05'00' 1 Applicant's Certification per 15A NCAC 02T .0106(b): 001,1.11,04 SEAL 044681 FNOINE:. •' Q: J, DN. ``° rrrnnn„,"` 1, Ken Kramer , attest that this application for Given Highland Farms Campus Redevelopment Phase 2 (Signature Authority Name from Application item 1.3.) (Project Name from Application Item attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. l also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.611, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: _Z. ;e/ / FORM: PTA 06-21 Page 5 of 5 DW 1 DEC1b1 ter Quality Reg::;' Asheville Rec.:: Division of Water Resources Entity Applicant Name: Robert Cork, Anchor PEA PLLC State of North Carolina Department of Environment Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE-04-16) Project Name for which flow is being requested: 2021201 - GIVENS HIGHLAND FARMS - APT DEMO AND REMODEL More than one F7SE mar he required for a single project if the owner of the II'UI'TP is not responsible for all pump stations along the route al.the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWII) Facility Name: Water Reclamation Facility b. WWTP Facility Permit 1/: NC0024911 c. WW1? facility's permitted flow: d. Estimated obligated flow not yet tributary to WWII): e. W W7•P facility's actual avg flow: I'. 'Total flow for this specific request: g. Total actual and obligated (lows to the facility: h. Percent of permitted flow used: 40 10.3160 24.2114 4II flows ure in MGD 0.0035 34.5274 86% I1. Complete this section Ibr each pump station you are responsible Ibr along the route of this proposed water flow. List pump stations located between the project connection point and the WWII) (A) (13) (C) (D)=(B+C) (E)=(A-D) Design Approx. Obligated, Not Total Current Pump Station Firm Average Daily Current Avg. Yet Tributary Flow Plus Available (Name or Capacity.* Flow** (Firm / Daily Flow, Daily Flow, Obligated Flow Capacity Number) MOD pl) MGD MGD MOD *** * The Firm Capacity of any pump station is defined as the maximum pumped now that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not Tess than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <= 0. Downstream Facility Name (Sewer): Downstream Permit Number: III. Cernication Statement: ..ir441 r�rd I MSD of Buncombe County Collection System WQCS00004 certify to the best ()I' my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the Ilow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation ofthe planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data . This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums Ibr which I am the responsible pi y. Sigj ..ure of this form indicates ac eptance of this wastewater flow. t/"l)tc ial .Sigjfnnnr / Daril igning Page I of I FTSL:04-16 li\ \ram, ' ,-.- DEC 1 6 2021 STATE OF NORTH CAROLINA COUNTY OF BuncombeWater Quality RegcrL ." % t :rations Asheville RegiolL, Utfice DEVELOPER'S OPERATIONAL AGREEMENT Permit No. This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this day of , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Givens Highland Farms, LLC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Buncombe County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as Campus Redevelopment Phase 2 (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, Givens Highland Farms, LLC (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction andrepair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions andlaw. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws andDeclaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 03-19 Page 1 of 2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit mayrequire as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of apermit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MANAGEMENT COMMISSION S. Daniel Smith Director, Division of Water Resources (Date) Givens Highland Farms, LLC Name of DEVELOPER By: ._ (Si Ken Kramer, Executive Director Print Name and Title (Date) FORM: DEV 03-19 Page 2 of 2 Jt.� � �f;li .. DEC 1 6 2021 Michael F. Easley, Governor William G. Ross, Jr., Secretary Water Quality Regional OperatlonNorth Carolina Department of Environment and Natural Resources Asheville Regional Office Alan W. Klimek, P.E., Director Division of Water Quality Asheville Regional Office WATER QUALITY SECTION Mr. Kenneth Partin, Executive Director Givens Estates 2360 Sweeten Creek Road Asheville, North Carolina 28803 Dear Mr. Partin: June 5, 2003 . Subject: Permit No. WQ0022578 Givens Estates \,12( Wastewater Collection System Extension ncombe County In accordance with your application received May 9, 2003, and additional information received on June 4, 2003, we are forwarding herewith Permit No. WQ0022578, dated June 5, 2003, to Givens Estates for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer named in the application. It shall be the Permittee's responsibility to ensure that the as - constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143- 215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Givens Estates for the construction and operation of approximately 7,157 linear feet of 8-inch gravity sewer as part of the Givens Estates project, and the discharge of 34, 700 Mr. Kenneth Partin June 5, 2003 Page Two gallons per day of collected domestic wastewater into the Metropolitan Sewerage District of Buncombe County's existing sewerage system, pursuant to the application received May 9, 2003, and additional. information received on June 4, 2003, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Metropolitan Sewerage District of Buncombe County's Wastewater Treatment facility (NPDES Permit No. NC0024911) prior to being discharged into the receiving stream. Construction of the subject wastewater collection system shall not commence until approval for the construction and operation of these sewers has been obtained from the Metropolitan Sewerage District of Buncombe County. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Larry Frost at (828) 251-6208. Surely, /Alan W. Klimek, P.E. Enclosure xc: Buncombe County Health Department Wm. James Jones — William G. Lapsley & Associates Water Quality Central Files NDPU Files Larry Frost eie 2 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES GIVENS ESTATES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT WQ0022578 This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted at least once per year. 3 WQ0022578 g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject. the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 4 WQ00578 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number (828) 251-6208, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letterform within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 5th day of June, 2003 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 1 Ian W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ000-a-5 7 Q. 5 Permit No. WQ0022578 June 5, 2003 f Complete and submit this form to the permit issuing Asheville Regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (7 periodically, ❑ weekly, ❑ full time) the construction of the Givens Estates wastewater collection system extension, Buncombe County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS: MR. FORREST R. WESTALL WATER QUALITY REGIONAL SUPERVISOR ASHEVILLE REGIONAL OFFICE 59 WOODFIN PLACE ASHEVILLE, NC 28801 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 6 l 1 � y I 'zo ° -<-- amp Dorothy Walls•...—„. Fellowship <4I AMErZi Ch rch 00� �o Sanatorium ? ( H j� �ail1 j c `--- ORAGMONT RD tl a r �� Jam' t cY\v P- r �;- Project Location =o,,� �* •Z cy 7 f----=''.----.<r l' cc c,, '�� m / _ _ }-III w, �° �o o LPG , }c ✓�_ �� Pi ui , �, J ai �TA:ERNACI�RD ` � .r' •.-ccir,)/ 0 LD,U.Si-i-HT/V-'//..Y1i170 ENA ST' 1-- .), ______-:-,— � 1! RFOT RD rovestone SOURCE: Base from DeLorme Topo USA. HORIZONTAL DATUM: NSRS 2011 North Carolina State Plane, NAD83, US Survey Feet Publish Date 2021/10/08 2:07 PM 1 User: jbigsby WFGW-AM LEGEND: Existing Sanitary Sewer Line Proposed Sanitary Sewer Line rilepath V. ProjectsV1510-Givens Highland FarrnsVCampus_ Redevelopment Phase 2\•PernittingVIS10 PM-001 (Vicinity Map) dvrg }) ldLU 'A ANCHOR QEA NORTH CAROLINA or Black Mountain Asheville • Charlotte 0 Not to Scale \�,v jHILLTOP RD`. "SR2 0 1) 0 1500 Feet Figure 1 Vicinity Map Water Quality Regional OpolailOnS Givens Highland Farms p�hol��j►e Regional Office Campus Redevelopment Phase 2 \1510-GHF-PH2-PL001-C 1510-givens highland tars\campus redevelo CAMPUS REDEVELOPMENT PHASE 2 GIVENS HIGHLAND FARMS NORTH CAROLINA .* Black Mountain Asheville • Charlotte VICINITY MAP 0 NORTH 0 2000 4000 SCALE IN FEET LOCATION MAP NORTH 0 300 600 SCALE IN FEET Water Quality Regional C erations Asheville Regional Office DRAWING INDEX SHT NO. DWG NO. TITLE 1 G1.0 COVER SHEET 2 G2.0 NOTES, LEGEND, AND ABBREVIATIONS 1 3 G2.1 NOTES, LEGEND, AND ABBREVIATIONS 2 4 E1.0 EXISTING CONDITIONS, WEST 5 E1.1 EXISTING CONDITIONS, EAST 6 C1.0 PROPOSED SITE PLAN, WEST 7 C1.1 PROPOSED SITE PLAN, EAST 8 C1.2 SITE DETAILS 9 C2.0 EROSION AND SEDIMENTATION CONTROL PLAN, WEST 10 C2.1 EROSION AND SEDIMENTATION CONTROL PLAN, EAST 11 C2.2 EROSION AND SEDIMENTATION CONTROL DETAILS 1 12 C2.3 EROSION AND SEDIMENTATION CONTROL DETAILS 2 13 C2.4 NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING 14 C2.5 NCGO1 SELF -INSPECTION, RECORDKEEPING, AND REPORTING 15 C3.0 PROPOSED GRADING PLAN, WEST 16 C3.1 PROPOSED GRADING PLAN, EAST 17 C4.0 ROAD PROFILE AND CROSS SECTIONS 18 C5.0 PROPOSED STORMWATER PLAN, WEST 19 C5.1 PROPOSED STORMWATER PLAN, EAST 20 C5.2 STORMWATER PROFILES 21 C5.3 STORMWATER DETAILS 1 22 C5.4 STORMWATER DETAILS 2 23 C6.0 PROPOSED WATER PLAN, WEST 24 C6.1 PROPOSED WATER PLAN, EAST 25 C6.2 WATER PROFILES 26 C6.3 WATER DETAILS 1 27 C6.4 WATER DETAILS 2 28 C7.0 PROPOSED SANITARY SEWER PLAN, WEST 29 C7.1 PROPOSED SANITARY SEWER PLAN, EAST 30 C7.2 SANITARY SEWER PROFILES 31 C7.3 SANITARY SEWER DETAILS 1 32 C7.4 SANITARY SEWER DETAILS 2 PROJECT DATA OWNER: GIVENS HIGHLAND FARMS, LLC 200 TABERNACLE ROAD BLACK MOUNTAIN, NC 28711 KEN KRAMER, EXECUTIVE DIRECTOR 828-357-3606 LANDSCAPE ARCHITECT: EQUINOX ENVIRONMENTAL 37 HAYWOOD STREET, SUITE 100 ASHEVILLE, NC 28801 MEGAN FOY 828-253-6856 CIVIL ENGINEER: ANCHOR QEA OF NORTH CAROLINA, PLLC 231 HAYWOOD STREET ASHEVILLE, NC 28801 WALTER DINICOLA, PE 828-281-3350 ARCHITECT: RLPS ARCHITECTS 250 VALLEYBROOK DRIVE LANCASTER, PA JOHN HOUCK 717-560-9501 BUNCOMBE COUNTY PIN: 0609-55-1146 ZONING DISTRICT: 01-6 RIVER BASIN: FRENCH BROAD PROPOSED USE: CONTINUING CARE RESIDENTIAL FACILITY PERMIT SET - NOT FOR CONSTRUCTION z 0 ANCHOR QEA 9:0-C/14 I G II L A N D ARMS 2pQ'Q oe sA ,.04 ,,9 2 E SEAL 09468I REVISIONS REV DATE BY APP'D DESCRIPTION DESIGNED BY: W. DINICOLA DRAWN BY: 1. BIGSBY CHECKED BY: ---- APPROVED BY: ---- SCALE: AS NOTED DATE: NOVEMBER 19, 2021 GIVENS HIGHLAND FARMS CAMPUS REDEVELOPMENT PHASE 2 COVER SHEET G1.0 SHEET R 1 OF 32 m =ill 0 rCO 7J i ��������i�r 1 I!!!!I!II�II��V, �.\\.1i\I: y1IIIIIIIIIIIIII\IIIIIIIIIIU\11�;IlVlll'IPI�Iilli�lllp o {l1� III �, ���IIIIIII�IIIIIIIIIIIIIi!i z �llllllll��1\,\\\\\\\,\\\\�!��������Illlllll� j ,!ill'III� II�\1\\l1'iii\lillli���\\��lu uI IIIIIk! co m 01 r 0 0, Security features included. Details on hack IIIIIIIIIIIII1111llllllllli'