Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0020132_Regional Office Historical File Pre 2018
State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director October JON C. DYER. DIRECTOR OF PUBLIC WORKS UNION COUNTY 400 NORTH CHURCH STREET MONROE, NC 28112 Subject: Dy NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCE Permit No. WQ0020132 Correction Union County Old Hickory Industrial Park Wastewater Collection System Extension Union County In accordance with your request received August 10, 2001, we are forwarding herewith the corrected page 2 of the cover letter of Permit No. WQ0020132 for the subject wastewater collection system extension. The following corrections have been made to the permit: 1. The permit has been corrected to indicate that the Union County Twelve Mile Creek wastewater treatment facility (NPDES Permit No. NC0085359) will receive the wastewater from this extension. Pleas: replace page 2 of the cover letter with the corrected page 2 of the cover letter into Permit No. WQ0020132 issued July 30, 2001. If you need any additional information concerning this matter. please contact Kristin E. Mtguez at. (919) 733-5083 extension 524. cc: Union County Health Departn-tent LandDesign, Inc. Mooresville Regional Office, Water Qu Permit File WQ0020132 Central. Flies y Section Sincerely, 1 Gregory J. Thorpe 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled//10% post -consumer paper Kerr T. Stevens The sewage and wastewater collected by this system shall be treated in the Union County Wastewater Treatment Facility (NPDES Permit No. NO0085359) prior to being discharged into the receiving stream. If any parts, requirements, or (imitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699- 6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Kristin E. Miguez at (919) 733-5083 extension 524. Sincerely, :if448nTh cc: Union County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0085359) LandDesign, Inc. Prate Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Kerr T. Stevens, Director July 30, 2001 JON C. DYER, DIRECTOR OF PUBLIC WORKS UNION COUNTY 400 NORTH CHURCH STREET MONROE, NC 28112 Dear Mr. Dyer: AVA NC NORTH CAROLINA r-ARTMENT OF' ENVIRONMENT AND NATtRAL RESOURCES JUL 3 1 2001 WATER QUA Lin/ SECTIO Subject: Permit No. WQ0020132 Union County Old Hickory Industrial Park Wastewater Collection System Extension Union County In accordance with your application received June 7, 2001, we are forwarding herewith Permit No. WQ0020132, dated July 30, 2001, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as - constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County for the construction and operation of approximately 7,163 linear feet of 8-inch gravity sewer, and 1,879 linear feet of 10-inch gravity sewer to serve as part of the Old Hickory Industrial Park project (trunk line), with no discharge of collected domestic wastewater into the Union County's existing sewerage system, pursuant to the application received June 7, 2001, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper The sewage and wastewater collected by this system shall be treated in the Union County Wastewater Treatment Facility (NPDES Permit No. NC0069841) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699- 6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Kristin E. Miguez at (919) 733-5083 extension 524. Sincerely, tha{-; ii tteAr err T. Stevens cc: Union County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0069841) LandDesign, Inc. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected at least three times per week until July 1, 2000; thereafter, pump stations shall be inspected at least daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every da_ y. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A.copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663- 1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Pry' Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the thirtieth day of July, 2001 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Aiierr T. Stevens, Director} r Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0020132 3 Permit No. WQ0020132 July 30, 2001 ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 4 Re: Wastewater Collection System Extension Union County Permit No, WQ0026132 i°r M�t� '% -7�s' ndustrial Park, Phase I N #t1 f9f ENGINEER'S PARTIAL CERTIFICATION I, Kevin W. Vogel, P,E., a duly registered Professional Engineer in the State of North Carolina, have periodically observed a portion of the construction of the wastewater collection system extension from existing Manhole 50 STA2+16.02 through Manhole30 STA77+00 for a total of 1,659 feet of 10' pipe and 6,065,12 of 8" pipe to serve Old Hickory Industrial Park, The facilities are covered under Permit Number ly 30, 2001. I state, in my professional judgment, that the construction of the partial wastewater collection system extension as referenced, was observed to be constructed within substantial compliance and intent of the approved plans and specifications. This statement is a declaration of professional judgment. It does not constitute a warranty, or guarantee, expressed or implied, nor does it relieve any other party of his responsibility to abide by contract documents, applicable codes, standards, regulations and ordinances.. Kevin W. Vogel, P.E. North Carolina Professional Engineer Number 21164 Date. May 25, 2004 G:1159905500CStCERTIFICATIONS 5,25,54 DOC/RTC LANDDESIGN May 25, 2004 Mr. Kim Colson Supervisor, Fast Track Permitting Rev ew System NC Division of Water Quality VVater Quality Operations 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Wastewater Collection System Extension Union County Permit No, WQ0020132 fANI-E° 7/37/ 0 I Old Hickory Industrial Park, Phase I Union County LandDesign PN #1099055 Dear Mr, Colson: VVATE•lid 20.1:4 •HNOW•DtSC•HAfiGEPERMITTING- After periodic and final observation cif wastewater collection system extension to serve Old Hickory Industrial Park, we are writing to certify completion of the work in accordance with the plans and specifications. This partial certification covers existing Manhole 50 STA2+16.02 through Manhole30 STA77+00 on Sheets 10-17 of the As - Surds for Phase I for a total of 1,659 feet of 10 pipe and 6,065,12 of 8" pipe. A copy of the State approval letter, observation report and As-Buirts plans are enclosed. The facilities are covered under Permit Number WQ0020132, dated July 30, 2001. Should you have any questions, please do not hesitate to contact us. yin W. el, P.E. Principal LandDesign Charlotte 704,333.0325 KW\drc Enclosures Ca: Charles 0' Cain, Union Co, Public Works Director Ken Chapman, Crosland Commerval G;41099055=C$42404412FICATUDNS 5.25 04 00CRTG UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232. To: NC Division of Water Quality Water Quality Section Permits and Engineering Unit 1617 Mail Service Center Raleigh, N.C. 27699-1617 Attention: TRANSMITTAL IV WATT: QUAx,l' NON.' Date: 7/7/04 Regarding: Record Drawings and Engineer's Certification for Old Hickory Industrial Park Phase 1 Sewer Trunk (Partial) We are sending you: Li Copy of letter Plans EIJ Prints © Shop Drawings Other Copies 1 1 Date No. Description 5/12/04 Record Drawings 5/25/04 Engineer's Certification for Sewer ( ±D0020132 These are transmuted as checked below: E] For approval For your use Ej As requested 0 For review and comments Remarks: Signe Receiv by: Date: North Carol October 3, 2006 Kevin W. V9t;`P. E. Land Dtg: 223 Nth Graham Street C otte,NC 2€3202 Michael F. F.aslc},Err ve OCT . 4 200( ATER QUALITY SECTI Subject: Incomplete/Inadequate Engineering Certit€cation Old Hickory Park Permit Number WQO020132 Union County Ross Jr., Secretary NauraResources n of . Director er Quality Dear Mr. Vogel. Regretfully, the Division can not accept the submitted engineering certification for the subject permit due to the following reasons:. The Division no longer accepts typed certification letters Only the approved Engineering Certlficoti Form provided as the last page in the issued permit is accepted. Record drawings are not present. Pump station calculations are not present, These are required upon completion of at projects issued a permit through the Division's fast track process. ❑ Project changes are not evident in the record drawings or provided in written form nor is there any indication that the project was completed with minimal changes that are in conformance with at statutes, regulations and our Minimum Design Criteria (if applicable). Q Partial or full certification is not indicated on the Engineering Certification Form or record drawings. PE seal, signature or date is missing from the Engineering Certification Form, record drawings and/or pump station calculations (if applicable). D The record drawings do not show at of the required information (Le, plan/pr©file of all sewer lines, all treatment component locations and sizes, site map, etc.). [l Inspection frequency is not specified on the Engineering Certification Form. The partial certification does not show a completed project section or phase. Other: Please make the appropriate corrections and resubmit the engineering certification along with a copy of this letter, to the appropriate regional office if noted on the certification form by November 3,2006 It is recommended that delivery of certifications provide some method of proof of receipt by the Division. Receipt of engineering certifications in no way absolves the Permittee's responsibility to ensure the project meets all statutes, regulations and design criteria associated with the project. Note that the Division reorganized. All sewer related matters are now handled through the Pretreatment, Emergency Response and Collection Systems Unit under the Point Source Branch. The Unit is located on the 13?,, floor of the Archdale building in downtown Raleigh. Please ensure the letterhead information is used for all correspondence to ensure timely delivery, Una NorthCarollna Naturally Pretreatment, 1617 Mail Sec, `l`clephone (919) 733-5b sponse and Collection Sys NC 77699-1617 nit lntcrnet http://h2o.enr.nc.state.us/ er s An Equal Opportunity Action Employer 5O o recycled// I0"A post -consumer paper Page 2 of 2 If you have any question regarding this letter, please feel free to contact me at 919-733-5083, extension 526. Enclosure CC: vTA Director of Public Works Union County 400 North Church Street Monroe, NC 28112 Central Files - WQ0020132 Sincerely, Tom Ascenzo Environmental Technician r�9 QG � r 1 C Michael F. Easley, Govemor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality October 5, 2006 Union County Public Works 400 North Church Street Monroe, North Carolina 28112-4804 SUBJECT: Old Hickory Industrial Park Phase 1 Permit No. WQ0020132 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: • The Division received a final engineering certification for the subject project on October 2, 2006: A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from htto://h2o.enr.state.nc.us/ndpu/ndouapps.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary}, please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, r.piD. Rex Gleason, P.E. 0 Surface Water Protection Regional Supervisor Enclosure Cc: Kevin W. Vogel Surface Water Protection Section Central Files (certification page only) Please forward copy to Engineer Nne orthCarohna Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.enr.nc.state.us/ndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper 1 VY4JVYLJL Permit No. WQ0020132 1 July 30, 2001 uL r UDL. ',mu m runt t1/el2 E�TGTNEER'S CERTIFICATION Partial , Y. Final I. YZ� l' k. Flo(-L as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, 244LJ &Q(, InlD1AJf ZA.1 L UNitsJ CO l for the Project Name 1 Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Past -Track Permitting of. Pump Stations and Force Mains adopted June 1.2000 as applicable; and other supporting aterials. North Carolina Professional Engineer's seal, signature, and date: s 1 -k� 154 iro The abv o e Engineer's Certification shall be completed and submitted to the address below with one copy of the ' onstruction Record _Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered.a violation of the permit and shall subject the Perrnittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 4 `UNION COUNTY PUBLIC WORKS 400 N.. Church Street Monroe, NC 28112-4804 704/296-421 Fax 704f294 32 tcor,E To: Mooresville Regional Office Water Quality 610 East Center Ave. Suite 301 Mooresville NC 28115 OCT - 2 200 ATER ouA 1 Y Attention: Dee Browder A`NSMITTAL Date: ,9f28/06 Regarding: Record Drawings and Engineer's Certification for Sewer to serve Old Hickory Industrial Park Phase 1 (Final Certification) We are sending you: Copies 1 Date No. 9/25/06 Copy of letter Other Plans Q Prints El Shop Drawings Description Record Drawings 9/25/06 Engineers Certification for Sewer (WQ0026132" These are transmitted as checked below: © For approval For your use 0 As requested 0 For review and comments Rema Signed: s: Received by: Date: