Loading...
HomeMy WebLinkAboutNC0061719_Performance Annual Report_20100226Performance Annual Report I. General Information Facility/System Name: Woodlake Responsible Entity: Aqua North Carolina, Inc. Person in Charge/Contact: Tom Roberts Applicable Permit (s): NC0061719 ~~WOCS00_123' Description of Collection System or Treatment Process: . NA- R AUG 1 0 2010 D This 0.50 MGD wastewater treatment facility consists of a bar screen, an Aeromod Complete Mix system, tube settling clarifier, sludge: digester, chlorination and post aeration. II. Performance Text Summary of System Performance for Calendar Year 2009 APR 1 6 2010 Overall the plant does perform well. Having clarifiers would replace the need for settler tubes. It has been budgeted in years past. Going forward, Aqua is trying to maximize the existing design of the plant. This includes coaching and training the operator with proper cleaning and maintenance procedures. List (by month) any violations of permit conditions or other environmental regulations. Monthly lists should include discussion of any environmental impacts and corrective measures taken to address violations. January Compliant February Compliant March The daily maximum for fecal was exceeded. The operator cleaned out the chlorine contact chamber. April The daily maximum for fecal coliform was exceeded. The chlorine chemical feed pump lost prime and therefore did not feed sufficient chemical. The operator re -primed the pump. May The daily maximum for fecal colifom was exceeded. The chlorine pump was replaced and the chlorine contact chamber was cleaned. June Compliant July Compliant August September The daily and average monthly NH3-N limits were exceeded. Aqua replaced a blower and stabilized the feed of Dissolved Oxygen. Subsequently, the concentration of NH3-N was lowered. wo daily fecal were exceeded due to the chemical feed pump losing prime again. The pump was replaced. The daily maximum for fecal colifom was exceeded. The operator found the chemical line to have a split. This line was replaced. October Compliant November The daily maximum for fecal was exceeded. This was caused by increased plant flow and underfeed of chlorine. December The daily maximum for fecal coliform was exceeded. This was caused by high plant flow and a dirty contact chamber. II. Notification Our customers will receive a letter regarding the availability of this report upon request. These reports will also be available for review with the customer at Aqua's Southern Ca11 Center. III. Certification I certify under penalty of law that this report is complete and accurate to the best of my knowledge. I further certify that this report has been made available to the users or customers of the named system and that those users have been notified of its availability. u7h q1L2/26/2010 Responsible Person Date Title: Regional Compliance Manager Entity: Aqua North Carolina, Inc.