HomeMy WebLinkAboutWQ0002376_RLAP Inspection Report_20211216ROY COOPER Governor ELIZABETH S. BISER Sec, Nat y S. DANIEL SMITH Director Summer Woodard — City Manager City of Reidsville 1100 Vance Street Reidsville, North Carolina, NC 27320 NORTH CAROLINA Environmental Quality December 16, 2021 Subject: Compliance Evaluation Inspection City of Reidsville, Residuals Land Application Program Permit No. WQ0002376 Rockingham County Dear Ms. Woodard: On November 30, 2021 staff of the North Carolina Division of Water Resources Winston-Salem Regional Office (DWR) performed an announced routine compliance inspection of the City of Reidsville's residuals land application program. This inspection was conducted by DWR staff member Jim Gonsiewski. Mr. Brent Collins of EMA Resources was present during this inspection. The inspection reflects compliance with the permit. Please refer to the enclosed inspection report for additional observations and comments. If you have any questions regarding this letter, please contact Jim Gonsiewski or me at (336) 776-9800. S incerely, CDocuSigned by: L.OA. T. SMIttt 145849E22§C94EA... Lon T. Snider Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ — WSRO enc.: Compliance Inspection Report cc: Brent Collins — EMA Resources (Electronic Copy) Rockingham County Environmental Health (Electronic Copy) WSRO Electronic Files Laserfiche Files ODE �I��Nnpn101(mNq,rtgn!p QuJii� North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 County: Rockingham Region: Winston-Salem Contact Person: Steven L Routh Directions to Facility: System Classifications: LA, Primary ORC: Brent M Collins Secondary ORC(s): On -Site Representative(s): Related Permits: Compliance Inspection Report Permit: WQ0002376 Effective: 06/04/20 Expiration: 12/31/26 Owner : City of Reidsville SOC: Effective: Expiration: Facility: City of Reidsville RLAP 230 W Morehead St Reidsville NC 27320 Title: Director of Public Works Phone: 336-349-1070 Certification: 27651 Phone: 336-751-1441 NC0024881 City of Reidsville - Reidsville WWTP Inspection Date: 11/30/2021 Entry Time 10:10AM Exit Time: 11:45AM Primary Inspector: Jim J Gonsiewski Phone: 336-776-9704 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Land Application of Residual Solids (503) Facility Status: Compliant ❑ Not Compliant Question Areas: El Miscellaneous Questions 1.1 Sampling MI Pathogen and Vector Attraction Transport (See attachment summary) Land Application Site Page 1 of 4 Permit: WQ0002376 Owner - Facility: City of Reidsville Inspection Date: 11/30/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On November 30, 2021 staff of the North Carolina Division of Water Resources Winston-Salem Regional Office (DWR) performed an announced routine compliance inspection of the City of Reidsville's residuals land application program This inspection was conducted by DWR staff member Jim Gonsiewski. Mr. Brent Collins of EMA Resources was present during this inspection. Loading operations at the City of Reidsville WWTP and field application of residuals were obsereved. The inspection reflects compliance with the permit. Page 2 of 4 Permit: WQ0002376 Owner - Facility:City of Reidsville Inspection Date: 11/30/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Distribution and Marketing ❑ Land Application ❑ Pathogen and Vector Attraction a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Sampling Describe sampling: TCLP, nutrients, metals, vecotr and pathogens Is sampling adequate'? Is sampling representative? Comment: Transport Is a copy of the permit in the transport vehicle? Is a copy of the spill control plan in the vehicle? Is the spill control plan satisfactory? Does transport vehicle appear to be maintained? Comment: Land Application Site Is a copy of the permit on -site during application events? Yes No NA NE ❑ ❑ II ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ ❑ • 0 • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ▪ ❑ ❑ ❑ ▪ ❑ ❑ ❑ Yes No NA NE ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ ■ ❑❑❑ Yes No NA NE • ❑ ❑ ❑ Page 3 of 4 Permit: WQ0002376 Owner - Facility: City of Reidsville Inspection Date: 11/30/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the application site in overall good condition? Is the site free of runoff/ponding? If present, is the application equipment in good operating condition? Are buffers being maintained? Are limiting slopes buffered? 10% for surface application 18% for subsurface application Are there access restrictions and/or signs? Is the application site free of odors or vectors? Have performance requirements for application method been met? For injection? For incorporation? Does permit require monitoring wells? Have required MWs been installed? Are MWs properly located wl respect to RB and CB? Are MWs properly constructed (including screened interval)? Is the surrounding area served by public water? If Annual Report indicates overapplication of PAN, are wells nearby that may be impacted? Are soil types consistent w/ Soil Scientist report/evaluation? Is the water table greater than 1'/3' bls. Is application occurring at the time of the inspection? Comment: No monitoring wells required. ▪ ❑ ❑ ❑ ■ ❑❑❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ U ❑ • ❑ ❑ ❑ ❑ ❑ U ❑ ❑ ❑•❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ U ❑ ❑ ❑ U ❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ Page 4 of 4 North Carolina Department of Environmental Quality Division of Water Resources Water Quality Section NON -DISCHARGE COMPLIANCE INSPECTION REPORT CLASS B RESIDUALS LAND APPLICATION General Information Facility Name: Reidsville v.VTP Permit No.: W00002376 Owner: City of Reidsville Plant ORC Name: Scott Bryan LA ORC / Contract Company: Brent Collins EMA County: Rockingham Permit Issuance Date: 06/04/20 Permit Expiration Date: 12/31/26 Telephone No.: 336-349-1100 Telephone No.: 336-399-3646 Other Contact(s): Telephone No.: Facility Location (address, gps or directions): 407 Broad Street Reidsville Reason for Inspection ROUTINE E FOLLOW-UP ❑ COMPLAINT ❑ PERMITTING ❑ Other: Comments (attach additional pages as necessary) On site at 10:10 AM. Met with Brent Collins, EMA. Met at the WVVTP. Four tankers/tractor trailers (7,200-gallon tankers - numbers 101, 105, 107, 115). Observed one tanker loading up residuals from the two 1,000,000-gallon concrete digesters. No spillage. No staining of the asphalt or tracking of sludge out of the WVVTP observed. Discussed operations at the WVVTP. Left WVVTP and travelled out to the land application site at 10:45 AM. Arrived at application field (NC-RC-011-02) at 11:10 AM. A rain guage was observed attached to one of the two tractors. Inspected the field. The terrain was slightly hilly with the slopes ranging from 0% to 6%. The solids content in the residuals was 1.12%. The field was properly flagged. No runoff or ponding of residuals from previous applications were observed. Two 4,200 gallon tractor -pulled spreaders (303 and 311) were applying residuals. At 11:20 AM, the equipment was moved to NC-RC-012-01. The O&M plan and the permit were present. The O&M plan was adequate. Each vehicle had an O&M plan and maps. The residual spreading was good. No additional run off or ponding was observed during the application. Proper buffers were maintained. Observed transfer of residuals from tankers to spreaders. No problems noted. Left the application fields at 11:45 AM. Is a follow-up inspection necessary? ❑ Yes ® No Primary Inspector: Jim Gonsiewski Date of Inspection: 11/30/2020 Secondary Inspector: Entry Time: 10:10 AM Exit Time: 11:45 AM Non -Discharge Compliance Inspection Report Residuals Generating Facility Was the residuals generating facility inspected? Residuals Storage: Describe storage: Two 1,000,000 - gallon concrete digesters. Number of days/weeks/months of storage: 4-5 months Residuals Sampling: Is sampling adequate and representative for each sample type? Describe Sampling (Pathogens, VAR, Nutrients/Metals, TCLP): TCLP, metals/nutrients, pathogens, vectors ® Yes ❑ No Transport Vehicle: Is transport occurring at time of inspection? Are necessary records (spill plan) present in vehicle? ID of observed vehicte(s): 101, 105, 107, 115, 211, 214 Record Keeping and Reporting Information: Is current permit and prior annual reports available upon request? Has the facility been free of public complaints for the last 12 months? TCLP analysis conducted and results available? Frequency? ® 1/yr or ❑ 1/permit cycle Residuals metals and nutrient analysis conducted? Frequency? quartef+(See permit for frequency) Nutrient and metals loading calculations? (to determine most limiting parameter) Do lab sheets support data reported on Residuals Analysis Summary? Are PAN balance records available and within permit limits? Are there nutrient (crop) removal practices in place? Are hauling records available? (gal and/or tons hauled during calendar year to date) Are field loading records available? Are field inspections conducted and are records available? Are soil sample results available? Did soil results call for lime amendment? If so, are there records of application? Soil results indicate that Cu & Zn indices are <3,000 (ideally <2,000)? Soil results indicate Na <0.5 meq/100 cm', and Exchangeable Sodium Percentage (ESP) <15%? Does the permit require groundwater monitoring? Are groundwater lab results present? There are no 2L GW standard violations indicated in the lab results? Pathogen and Vector Attraction Reduction Records Pathogen Reduction: Which Alternative was used to demonstrate compliance? ❑ Alternative 1 Fecal Coliform Density. Were 7 samples collected and geometric mean <2 million mpn/cfu? ❑ Alternative 2 Process to Significantly Reduce Pathogens (5 options) ❑ Alternative 3 Use of Equivalent to RSRP (Not commonly used - See White House Manual) IfAlternative 2 was used, select which Option was utilized and complete the section below. ❑ Option 1 - Aerobic Digestion Are logs present showing time and temperature? Was the time & temp. between 40 days at 68°F (20°C) and 60 days at 59° F (I5°C)? ❑ Option 2 - Air Drying ❑ Option 3 - Anaerobic Digestion Are logs present showing time and temperature? Was the time & temp. between 15 days at 95° F — 131° F (35°-55° C) and 60 days at >68° F (20° C)? ❑ Option 4 — Composting (Not commonly used - See White House Manual) ❑ Option 5 - Lime Stabilization Are logs present showing time and temperature? Was the pH raised to >12 after two hrs of contact? Was the temperature corrected to 25° C (77° F) (by calculation, NOT auto correct)? Page 2 of 4 Y N NA NE N OD ❑ Y N NA ® ❑ ❑ ® ❑ ❑ Y N NA ® ❑ ❑ ® ❑ ❑ ® ❑ ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ® ❑ ❑ • ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑❑❑❑❑® ❑❑ ®M®❑❑❑❑❑❑®❑❑❑❑❑r ❑❑4 Y N NA NE ® ❑ ❑ ❑ Y N NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ DODD DODO L OD ❑ Non -Discharge Compliance Inspection Report Vector Attraction Reduction: Select which Option was used to demonstrate compliance and complete answer associated questions. El Option 1 - 38% Volatile Solids Reduction Y N NA NE Are lab results and calculations present? DODD Was the reduction on volatile solids (not total solids)? ❑ ❑ ❑ ❑ Were samples collected at correct locations? ❑ ❑ ❑ ❑ (beginning of digestion process & before land application) Was there a >38% reduction? DDDD ❑ Option 2 - 40-Day Bench Scale Test Y N NA NE Were residuals from an anaerobic digester with average temp. 30°C — 40°C? ❑ ❑ ❑ ❑ Are lab results and calculations present? ❑ DOD Was the test anaerobically digested in lab, and test run for 40 days? ❑ ❑ ❑ ❑ Was the lab bench -scale test done between 30°C (86°F) and 37°C (99°F)? ❑ ODD Was the reduction of on volatile solids (not total solids)? ❑❑ DDD ❑ ❑ ❑ Was the reduction less than 17%? ❑ Option 3 - 30-Day Bench Scale Test Y IN NA NE Were residuals from aerobic digestion? ® DOD Are lab results and calculations present? ❑ ® ❑ ❑ Were residuals 2% or less total solids? ® DOD If not 2% total solids, was the test ran on a sample diluted to 2% with unchlorinated effluent? ❑ ❑ ❑ Was the test run for 30 days? NIODD Was the test done at 20°C (68°F)? DDO Was the reduction of on volatile solids (not total solids)? MOOD Was the reduction less than 15%? NDDD ❑ Option 4 - Specific Oxygen Uptake Rate (SOUR Test) Y N NA NE Were residuals from aerobic digestion? ❑ ❑ ❑ ❑ Were residuals <2% total solids (dry weight basis) (not diluted)? ❑ DDO Was the test done between 10°C (50°F) and 30°C (86°F)? DODD Was the temperature corrected to 20°C (68°F)? ❑ DOD Was the sampling holding time <2 hours? ❑ DDO Was the test started within 15 minutes of sampling or aeration maintained? DODD Was the SOUR equal to or less than 1.5 mg of oxygen per hour per gram of total residual solids (dry weight basis)? EDDO ❑ Option 5 - 14-Day Aerobic Process Y N NA NE Were the residuals from aerobic digestion? DODD Was the average residuals temperature higher than 45°C (113°F)? ❑ ODD Were the residuals treated for 14 days and temperature maintained higher than 40°C (104°F) for the 14-day period? DODO ❑ Option 6 - Alkaline Stabilization Y N NA NE Was the pH of the residuals raised to >12 and maintained for two hours without addition of more alkali? ❑ ❑ ❑ ❑ Did the pH of residuals remain at > 11.5 an additional twenty-two hours (i.e. 24 hours total) without the addition of more alkali? DODD Was the pH corrected to 25°C (77°F) (by calculation, NOT auto correct)? DODD ❑ Option 7 - Drying of Stabilized Residuals Y N NA NE The residuals do not contain unstabilized residuals? DODD Were the residuals mixed with any other materials? ❑ ❑ ❑ ❑ Were the residuals dried >75% total solids? DODD ❑ Option 8 - Drying of Unstabilized Residuals Y N NA NE Were the residuals mixed with any other materials? DODO Were the residuals dried >90% total solids? LI ODD ❑ Option 9/10 — Injection/ Incorporation of Residuals (Not commonly used - See White House Manual) Page 3 of 4 Non -Discharge Compliance Inspection Report Land Application Site(s) Were application site(s) inspected? Ifso, please list Site ID(s) below. Application Site ID(s): NC-RC-011-02, NC-RC-012-01 ®Yes No Is application occurring at the time of inspection? ® Yes ❑ No If no, note the date of the last event: Was the Division notified of the application event(s)? ® Yes ❑ No Weather Conditions: ® Sunny ❑ Partly Cloudy ❑ Cloudy ❑ Overcast ❑ Stormy ❑ Windy (wind direction: ) ® Breeze ❑ Calm ® No Precipitation ❑ Drizzle 0 Rain ❑ Cloudburst (If applicable, precipitation measurement: Is there a rain gauge onsite? ® Yes ❑ No Weather Notes (i.e. Significant Changes, Forecasts, etc): Temp. (° F): ❑ <32 ❑ 32 — 40 ® 40 — 60 0 60 — 80 Permit and Spill Plan onsite during application? ® Yes ❑ No ❑ >80 Application Observations: [Type of application: ® Liquid ❑ Cake ❑ Other Application Site —Field ID(s): NC-RC-012-01 Intended Crop: Fescue Application Rate (tons or gallons/acre): Nutrient Content: 1.12% PAN Requirement: 209 Ibs/ac 13,000 gallons/acre % of total field area utilized or anticipated for this event? 90 Application occurring at time of visit: ® Yes ❑ No Application Method: ® Surface ❑ Incorp/Injection Incorporation/Injection during visit: ❑ Yes 0 No ® N/A Vegetative Buffer description: ❑None ®Grass ❑Crop 0 Shrub ['Tree 0 Other Current Field Conditions: 0 Bare 0 Stubble 0 Planted Ftaspue ® Pasture Soil Condition: ® Dry 0 Moist ❑ Wet 0 Saturated ® Not -Frozen 0 Frost 0 Frozen 0 Snow -Covered Slope: ® 0-3% ® 3-6% ❑ 6-10% ❑ I0-18% 0 >18% Odor: I None ❑ Mild ❑ Moderate ❑ Strong Vectors: ® None ❑ Few 0 Many 0 Excessive Application Details: Application areas clearly marked? Application within authorized area? Application method appropriate? Application is even (no ponding)? Sufficient setbacks from wells/residences? Sufficient setbacks from surface waters? Slopes >l0% avoided (Surface App.) ? Slopes>18% avoided (Incorp/Inject) ? Incorp./Injection within time -frame? Biosolids visible on surface? Site Restrictions Public access is restricted / Signage present? Grazing restrictions are met? Transfer of biosolids is in permitted area? No evidence of shallow GW? Sufficient timing for harvest restrictions? Off Site Transport Tracking is prevented? Biosolids run-off is prevented? Windblown biosolids prevented? Vegetative buffers exist? Y N NA NE IM❑ ❑ ❑ M 0 0 0 El DOD ill❑❑❑ M ❑ ❑ ❑ ❑ ❑ ® ❑ ❑❑®❑ ® ❑ ❑ ❑ Y N NA NE ❑ ❑ ® ❑ O 0 0 0 ® ❑ ❑ ❑ ® ❑ ❑ ❑ ®❑ D ❑ Y N NA NE ® ❑ ❑ ❑ 0000 MEIEID WOOD Application Site —Field ID(s): - Intended Crop: _ PAN Requirement: Ibs/ac Application Rate (tons or gallons/acre): Nutrient Content: %oftotal field area utilized or anticipated for this event? Application occurring at time of visit: ❑ Yes 0 No Application Method: 0 Surface 0 Incorp/Injection Incorporation/Injection during visit: ❑ Yes 0 No 0 N/A Vegetative Buffer description: ❑None ❑Grass 0Crop ❑ Shrub ['Tree 0 Other Current Field Conditions: ❑ Bare ❑ Stubble Cl Planted (crop) ❑ Pasture Soil Condition: ❑ Dry ❑ Moist ❑ Wet ❑ Saturated ❑ Not -Frozen 0 Frost 0 Frozen ❑ Snow -Covered Slope: ❑ 0-3% ❑ 3-6% 0 6-10% 0 10-18% ❑ >18% Odor: 0 None 0 Mild 0 Moderate ❑ Strong Vectors: 0 None ❑ Few 0 Many 0 Excessive Application Details: Y N NA NE Application areas clearly marked? ❑ 0 El 0 Application within authorized area? 0 0 El ❑ Application method appropriate? ❑ ❑ ❑ ❑ Application is even (no ponding)? ❑ ❑ ❑ ❑ Sufficient setbacks from wells/residences? ❑ 0 0 0 Sufficient setbacks from surface waters? 0 ❑ 0 ❑ Slopes >10% avoided (Surface App.)? ❑ ❑ ❑ ❑ Slopes >I8%avoided (Incorp/Inject)? 0 ❑ 0 El Incorp./Injection within time -frame? ❑ ❑ ❑ ❑ Biosolids visible on surface? 0 0 0 0 Site Restrictions Public access is restricted / Signage present? Grazing restrictions are met? Transfer of biosolids is in permitted area? No evidence of shallow GW? Sufficient timing for harvest restrictions? Off Site Transport Tracking is prevented? Biosolids run-otl is prevented? Windblown biosolids prevented? Vegetative buffers exist? Y N NA NE DODO DODD ❑ ❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Y N NA NE ❑ ❑ ❑ ❑ ❑D Page 4 of 4