Loading...
HomeMy WebLinkAboutNC0088765_Water Compliance Inspection Report_20160602 United!States Envirorvnentel Protection Aganry Form Approved. EPA Washington,D.C.20,160 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 15 ' 3 I NC0088765 I11 121 16/05/18 I17 18'ej 19 I ,¢ t 20I 21111111 IIIIIIIIIII 1111111 1111111 11111111111 Inspection Work Days Facility Self-Monitoring Evaluation Rating 81 CA Reserved 671 I 701 I 71 I I 72 I a, I 731 I 174 751 I I I I I I IBO LJ Section B:Facility Data I I I I I Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 02:OOPM 16/05/18 12/12/01 Tuckaseages RV Resort 78 Wilmont Cemetery Rd Exit Time/Date Permit Expiration Date Whittier NC 28789 03:OOPM 16/05/18 17/11/30 Names)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Mark Fredrick Teague/ORC/828-293-9396/ Name,Address of Responsible Of6cial/Title/Phons and Fax Number Contacted Wayne Smith,51 Bridge St SyNa NC 28779//828586-0724/8286319227 No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit 0 Operations 8 Maintenance 0 Facility Site Review 0 Effluent/Receiving Waters Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Names)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date G.Landon Davidson ARO GW//828-2964500/ ��// Timothy H Heim ARO WO//828-2964c 665/ Y— Signature of Management O A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions am obsolete. Page# 1 Perna: NCO088765 Owner-Facility: T-kaseegee RVRewrt Inspeeaon Date: 05118/2016 (nape tion Type: compliance Sampling Operations S Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ 0 ❑ ❑ Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ M ❑ ❑ Solids,pH, DO, Sludge Judge,and other that are applicable? Comment: Weeds and veoetation have significantly overgrown the facility and must be removed.This presents both an operational barrier and safety hazard to the ORC and inspector. Institute a regular program for weed/vegetation control. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ #Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? ❑ 0 ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The effluent weir box and UV disinfection chamber are unsecured and potentially accessible by the public. These constitute a safety hazard (specifically for children). Secure access with a fence or lock system. Pump Station -Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Is the wet well free of excessive grease? M ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? M ❑ ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ 0 ❑ Is audible and visual alarm available and operational? ❑ 0 ❑ ❑ Comment: Audible and visual alarm was tested by the ORC during the inspection and the audio component was not functional. Repair the alarm system. The ORC shall perform regular inspection and documentation of the pump station as required by the permit conditions. Disinfection -UV Yes No NA NE Are extra UV bulbs available on site? ❑ 0 ❑ ❑ Are UV bulbs clean? ❑ 0 ❑ ❑ Is UV intensity adequate? ❑ 0 ❑ ❑ Is transmittance at or above designed level? ❑ ❑ ❑ 0 Is there a backup system on site? ❑ 0 ❑ ❑ Page# 3