Loading...
HomeMy WebLinkAboutNC0060283_Response to NC NOV-2021-TX-0065_20211214 TREVCO ENVIRONMENTAL * MAINTENANCE 2020 Howard Gap Road Hendersonville,N.C.28792 Phone(828)691-7191 12/14/21 Division of Water Resources,NCDEQ Aquatic Toxicology Branch Supervisor Attn: Cindy Moore 1621 Mail Service Center Raleigh,NC 27699-1621 Ms. Moore: In regard to NOV 2021-TX-0065 for Ridge View Community (permit 4NC060283) we ask for leniency in lieu of a fine to continue to try and find a resolution to this problem. We have not had a Toxicity problem since 2013. The Community is noncomplex wastewater, has no industrial wastewater, and consists of 100% domestic wastewater_ So far we have tried the following: We have tested above the chlorine and dechlor feeders for toxicity and have found an oxidizer that is not being added by the owner or operator. Door to door informational interviews have been conducted by the operator and owners staff. Three paper notifications have been mailed to the tenants. We are working closely with ETS Inc lab to identify the oxidizer. A head wall was installed in the receiving stream to address inflow into the system. All the septic tanks have been pumped and cleaned out 1 time with lot 5&7 septic pumped twice. Organics and inorganics samples have been taken from two suspect septic tanks before initial pumping. Jim at ETS had me sample all 14 septic tanks prior to pumping looking for the oxidizer. A DPD test for chlorine was run on the creek and ground water that was dug up in an exploratory hole in the center of park and was found to be absent for chlorine. We are conducting ongoing THE analysis to determine and resolve our toxicity problem as soon as possible. We have conducted additional (not required) Toxicity sampling above the chlorine and dechlor tablet feeders that also failed. We have removed Lots S and 7 from the effluent by pumping the septic tank and still did not pass (lots S and 7 had the highest# of organics and inorganics of the tested lots in park). We contacted and attempted to hire Forrest Westall to help us know where to go next, he was very helpful and allowed the operator to ask all his questions. He did not see an engineering solution to our problem. Information was supplied by Hach (DPD test) of other oxidizers that can act like chlorine in their test. Norweco (chlorine and dechlor)was contacted by the operator for assurance that their chemical were not over strength. The Owner has made this a top priority to eliminate the toxin to protect the environment. He has funded this search in every direction that we could think of. Please allow us time and resources to remedy this problem in lieu of a possible fine. Your understanding in this matter is greatly appreciated. If I can be of further assistance please don't hesitate to call. Sincerely, Trevor C. McMinn (ORC) Ridge View Community