From: Parker, Jerry A
Sent: Thursday, December 02, 2021 2:14 PM
To: Conchilla, Ryan
Subject: FW: [EXTERNAL] FW: B-4805
Rya n,
This is the email chain that describes how Duke Power has been instructed to install the utility poles. Let me know if you
have any questions.
Jerry
From: Eason, Patty P<peason@ncdot.gov>
Sent:Wednesday, December 1, 2021 2:35 PM
To: Parker,Jerry A<japarker3@ncdot.gov>
Subject: RE: [EXTERNAL] FW: B-4805
Jerry:
Before I send this on to Duke, do you need to run it by Ryan or anyone? I didn't want to risk putting you in a bind if I
needed to wait.
Thank you!
From: Parker,Jerry A<japarker3@ncdot. ov>
Sent:Tuesday, November 30, 2021 2:50 PM
To: Eason, Patty P<psaan@ncdaategaa_v>
Subject: RE: [EXTERNAL] FW: B-4805
Patty,
From what I am gathering from the email is that they can auger the hole using a line truck, place the pole in the hole and
install pole foam instead of putting back the dirt. The dirt would not be placed in the adjacent wetland or buffer but
would be hauled off and disposed of properly. If they could install the poles this way, we should be okay.
Jerry
From: Eason, Patty P<psaan@ncdaategaa_v>
Sent:Tuesday, November 30, 2021 11:40 AM
To: Parker,Jerry A<japarker3@ncdot. ov>
Subject: FW: [EXTERNAL] FW: B-4805
This is Duke's response to B-4805. Is this acceptable?
Thank you!
i
From: Roberts, Randall K<Ran_d_alI_._Ro.berts(
Sent:Tuesday, November 30, 2021 11:00 AM
To: Eason, Patty P<pn sc n( ncd_nt:.f >; Daniels, Don T<D ne_Daniels(2_d_uk�..- com>
Subject: RE: [EXTERNAL] FW: B-4805
CAUTION. External email. Do not click links or open attachments unless you verify.Send all suspicious email as an attachment to
Report Sparn.
Patty,
We will use a standard auger on the line truck to dig the hole and once the pole is set we will use hydraulic tamps to
tamp the hole. I can have them hand dig the hole also, if using the auger is a concern, and I can have them install pole
foam in the pole hold, instead of putting dirt back if that is a better option.
Thanks,
Randy
From: Eason, Patty P<pnsaan( ncdaategaa_v>
Sent:Tuesday, November 30, 2021 10:47 AM
To: Daniels, Don T< on: a_ni21.s.2.4d .Ake_-nn_�_rRy com>; Roberts, Randall K<Ran_d_all.F�c bnrts( d ak - ner com>
...._...
Subject: [EXTERNAL] FW: B-4805
Good morning:
Can you provide a description of how the pole would be installed? Such as auger, set pole, etc.? I have attached the
roadway plan sheet that indicates buffer zone and wet land area that the pole and guy are planned? The guy on
northside indicates hand dug in the wetland so that should be sufficient but the pole installation in the buffer just needs
some description and I think we will be fine.
Thank and have a great, thankful Thanksgiving.
From: Parker,Jerry A<japarker3( ncdot. v>
Sent:Tuesday, November 23, 2021 2:23 PM
To: Eason, Patty P<pnsaan( ncd_nt:.f >
Subject: RE: B-4805
Patty,
After reviewing the attached drawings and consulting with the USACE Representative, I believe that NCDOT should be
okay to proceed with this project provided that the contractor submits a description of how they plan to install the
utility poles.The description should specify that any clearing in the wetlands will be by hand only and there should be no
removal of vegetation in the buffer. Except for the actual placement of the poles and anchor wires, there should be no
bottom disturbing activity in either the wetlands or buffer. Hammering or augering the poles is allowable. Some types of
machinery may be okay in the buffer as long as it does not disturb the bottom and does not result in the removal of
vegetation. If machinery will be used in the buffer, please specify the type of machinery and where it will enter and exit
the buffer. Any disturbance in the buffer should be minimized. Definitely do not cross the stream with any
machinery. Also, any poles placed in the buffer should be at least 10 feet from the top of bank. Let me know if you have
any questions.
2
Jerry
From: Eason, Patty P<psaan( ncdaategaa_v>
Sent: Monday, November 22, 2021 6:48 PM
To: Parker,Jerry A<jagarker3( ncdot. v>
Subject: B-4805
Jerry:
This is a bridge replacement project in Rockingham that Tim is letting. The permit shows no permitted sites or impacts
but drawing file attached has Duke with two PUEs, one in the buffer zone and one in a wetland area. Are these impacts
so small that no permit is needed? I just want to be sure because Tim has let the project and I am trying to get utilities
going.
Let me know or we can discuss.
Thanks.
Patty Eason, PE
Division Construction Engineer
336-487-0000