Loading...
HomeMy WebLinkAboutNC0085154_Compliance Evaluation Inspection_20211213DocuSign Envelope ID: 666051 F4-9873-4B03-89E5-29C29425CCAE ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED. December 13, 2021 Email: Jared Trent Duncan, ORC tduncan@weavervillepublicworks.org SUBJECT: Compliance Inspection Report Lawrence T. Sprinkle Jr. WTF NPDES WW Permit No. NC0085154 Buncombe County Dear Mr. Duncan: The North Carolina Division of Water Resources conducted an inspection of the Lawrence T. Sprinkle Jr. WTF on 12/07/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0085154. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at linda.wiggs@ncdenr.gov. ATTACHMENTS — Inspection Report Ec: Server, LF Sincerely, DocuSigned by: �.tin.a�a 'Wiogogy 6C38CDE2B5CF449... Linda Wiggs Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ DEQ North Carolina Department of Environmental Quality 1 Division of Water Resources Asheville Regional Office 12090 US- Highway 70 1 Swannanoa, North Carolina 28778 828.296 4500 DocuSign Envelope ID: 666051 F4-9873-4B03-89E5-29C29425CCAE United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL I 21IIIIII IIIIIIIIIIIIIIIIII NPDES yr/mo/day Inspection 3 I NC0085154 111 121 21/12/07 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 I IIIIII P6 Inspection Work Days 671 Facility Self -Monitoring Evaluation Rating B1 QA Reserved I 70I I 711 1 72 I N I 73I 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Lawrence T. Sprinkle Jr. WTF 50 Sam's Rd Weaverville NC 28787 Entry Time/Date 10:30AM 21/12/07 Permit Effective Date 21/01/01 Exit Time/Date 12:30PM 21/12/07 Permit Expiration Date 25/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Jared Trent Duncan,PO Box 338 Weaverville NC 287870338//828-658-2417/ Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Compliance Schedules Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Linda S Wiggs of Inspector(s) DS PIO Agency/Office/Phone and Fax Numbers Date DWR/ARO WQ/828-296-4500 Ext.4653/ Signature of Management Q A Reviewer i DS Agency/Office/Phone and Fax Numbers • Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 DocuSign Envelope ID: 666051 F4-9873-4B03-89E5-29C29425CCAE 3I NPDES yr/mo/day NC0085154 I11 121 21/12/07 17 Inspection Type 18LI (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Inspector, Linda Wiggs, met with the ORC, Trent Duncan to conduct a Compliance Evaluation Inspection. Two filters are backwashed approximately every 60 hours in the winter and approximately every 100 hours in the summer. This depends on Ivy River water quality which the ORC said has improved over time. Solids Management: Weaverville currently employs Bionomics annually to manage solids. Bionomics was last onsite for approximately 2 weeks in August -September 2021. The company set up a belt press system onsite and hauled a daily load each day to the County landfill. Weaverville is considering an expansion in the future at this facility, as well as extending the discharge line down the road. Records are well organized. ETS is the laboratory used by Weaverville, ETS contracts Metals work out. Metals results are reported by the laboratory in mg/I, the ORC needs to convert the Metals result values to ug/I for DMR reporting. Calcium Thiosulfate liquid is used for de -chlorination. The facility has a Compliance Schedule (Compliance Action Plan CAP) for Copper (Cu). The first annual CAP is due 1/2/2022. Page# 2 DocuSign Envelope ID: 666051 F4-9873-4B03-89E5-29C29425CCAE Permit: NC0085154 Inspection Date: 12/07/2021 Owner - Facility: Lawrence T. Sprinkle Jr. WTF Inspection Type: Compliance Evaluation Compliance Schedules Is there a compliance schedule for this facility? Is the facility compliant with the permit and conditions for the review period? Comment: The first annual CAP is due 1/2/2022. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Process controls include pH, TRC. Yes No NA NE • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new MODE application? Is the facility as described in the permit? • El El ❑ # Are there any special conditions for the permit? • El El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • El El El Comment: Compliance Action Plan for Copper. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • El El El Is all required information readily available, complete and current? • El El El Are all records maintained for 3 years (lab. reg. required 5 years)? • El El El Are analytical results consistent with data reported on DMRs? • El El El Is the chain -of -custody complete? • El El El Dates, times and location of sampling ■ Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis • Name of person performing analyses ■ Transported COCs • Are DMRs complete: do they include all permit parameters? • El El El Has the facility submitted its annual compliance report to users and DWQ? El El • El Page# 3 DocuSign Envelope ID: 666051 F4-9873-4B03-89E5-29C29425CCAE Permit: NC0085154 Inspection Date: 12/07/2021 Owner - Facility: Lawrence T. Sprinkle Jr. WTF Inspection Type: Compliance Evaluation Record Keeping (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: ETS is the Contract Lab. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ • ❑ Is storage appropriate for cylinders? ❑ ❑ • ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ • ❑ Are the tablets the proper size and type? ❑ ❑ • ❑ Comment: Calcium Thiosulfate is used. Are tablet de -chlorinators operational? ❑ ❑ • ❑ Number of tubes in use? Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Yes No NA NE Page# 4 DocuSign Envelope ID: 666051 F4-9873-4B03-89E5-29C29425CCAE Permit: NC0085154 Inspection Date: 12/07/2021 Owner - Facility: Lawrence T. Sprinkle Jr. WTF Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Are weirs level? ❑ El • El Is the site free of weir blockage? ❑ El • El Is the site free of evidence of short-circuiting? • ❑ ❑ ❑ Is scum removal adequate? ❑ ❑ • ❑ Is the site free of excessive floating sludge? • ❑ ❑ ❑ Is the drive unit operational? ❑ El • El Is the return rate acceptable (low turbulence)? ❑ ❑ • ❑ Is the overflow clear of excessive solids/pin floc? • ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) • ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ • ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? • ❑ ❑ ❑ Is the tubing clean? ❑ ❑ • ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ Page# 5