HomeMy WebLinkAboutWQ0043001_Application (FTSE)_20211101DWR
Division of Water Resources
NC Dept of Environmental Quality
State of North Carolina
Department of Environmental Quality
Division of Water Resources
NOV 01 2021 FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 06-21 & SUPPORTING DOCUMENTATION
Application Number: Wp\NoCelOO\ (to be completed by DWR)
All items must be completed or the application will be returned
1. APPLICANT INFORMATION:
I. Applicant's name: Johnston County (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership
❑ Federal ® State/County ❑ Municipal
3. Signature authority's name: Chandra C. Farmer, PE per I5A NCAC 02T .0106(b)
Title: Director of Utilities
4. Applicant's mailing address: 309 E. Market Street PO Box 2263
City: Smithfield State: NC Zip: 27577
5. Applicant's contact information:
Phone number: (919) 989-5 1 00 Email Address: chandra.farmer@johnstonnc.com
11. PROJECT INFORMATION:
1. Project name: Cleveland Apartments Gravity Sewer Extension
2. Application/Project status:
Proposed (New Permit)
If a modification, provide the existing permit number: WQ00
❑ Privately -Owned Public Utility
❑ Other
NC Dept of Environmental Quality
NOV 01 202i
Raleigh Regional Office
❑ Existing Permit/Project
and issued date:
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Johnston County
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.566751 Longitude: -78.529671
5. Parcel ID (if applicable): 06E03199D (or Parcel ID to closest downstream sewer)
11I. CONSULTANT INFORMATION:
1. Professional Engineer: Kimberly C. Rineer P.E. License Number: 025511
Firm: Johnston County Public Utilities
Mailing address: 309 E. Market Street PO Box 2263
City: Smithfield State: NC Zip: 27577
Phone number: (919) 989-5725 Email Address: kim.rineer a johnstonnc.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
I . Facility Name: Central Johnston County Regional Wastewater Facility Permit Number: NC0030716
Owner Name: Johnston County
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
I. Permit Number(s): W00028844
2. Downstream (Receiving) Sewer information: 8 inch
IL Gravity E Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCS00060
Owner Name(s): Johnston County
VI. GENERAL REQUIREMENTS
I. if the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑ No ® NIA
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement i I'ORM: DEV) been attached?
❑ Yes ❑ No ®NIA
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational lt}lliFlaatiti,}uality
supplementary documentation as required by 15A NCAC 02T.0115(c) been attached?
❑ Yes ❑ No ® N/A
4. Origin of wastewater: (check all that apply):
❑ Residential (Individually Owned)
® Residential (Leased)
❑ School 1 preschool / day care
❑ Food and drink facilities
❑ Businesses / offices / factories
❑ Retail (stores, centers, malls)
❑ Retail with food preparation/service
❑ Medical r' dental ! veterinary facilities
❑ Church
❑ Nursing Horne
NOV 01 2021
❑ (=Reek* Regional Office
❑ Hotel and/or Motels
❑ Swimming Pool/Clubhouse
❑ Swimming Pool/Filter Backwash
❑ Other (Explain in Attachment)
5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103.(201)
If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No
6. Has a flow reduction been approved under 15A NCAC 02T ,01 14(f)? ❑ Yes ® No
> If yes, provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow e,n
No. of Units
Flow
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
GPD
a See I5A.NCAC 02T .01 14(b], (d), (e)(11 and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T.0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14j shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114)
> Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that conneati.,line.
Please provide supplementary information indicating the approximate timeframe f�Cp�pitti�tt�4�l r it `flow.
❑ Flow has already been allocated in Permit Number: _ Issuance Date:
® Rehabilitation or replacement of existing sewers with no new flow expected
❑ Other (Explain):
NOV 01 2021
Raleigh Regional Office
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
I. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8"
317'
PVC
➢ Section II & 111 of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - .
3. Total number of pumps at the pump station:
3. Design flow of the pump station: millions gallons per day (firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s): gallons per minute (GPM) at
5. Summarize the force main to be permitted (for this Pump Station):
feet total dynamic head (TDH)
Size (inches)
Length (feet)
Material
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01C.1.b. D Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify)
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or El Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B):
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(I)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(()_&(g)? ® Yes ❑ No
15A NCAC 02T.0305(f) contains minimum separations that shall be Drovided for sewer systems:
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
18 inches
'Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
'Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class 1 or
Class II impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
I0 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application
*15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatiyes are used and provide narrative information to explain.
**Stream classificatioy .can be identified using the Division's NC Surface Water Classifications webpage
2. Does this proJect complyywith the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A
➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document,
signefllsealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply we separation requirements for wetlands? ❑ Yes ❑ No ® NiA
➢ Please provide suppy entary information identifying the areas of non-conformance.
➢ See theDivision's'draft separation requirements for situations where separation cannot be met.
➢ No variance is required if the alternative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No
If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No
➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage/authorization under a 404 Nationwideiindividual permits ❑ Yes ® No
or 401 Water Quality Certifications?
➢ Please provide the permit number./permitting status in the cover letter if coveragelauthorization is required.
6. Does project comply with 1 5A NCAC 02T.0105(c)(6) (additional permitsicertifications)? ® Yes ❑ No
Per ISA NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No
Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
X. CERTIFICATIONS:
I. Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains ('latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer
review times. For projects requiring two or more variances or where the variance is determined by the Division to be a
significant portion of the project, the full technical review is required.
2. Professional Engineer's Certification:
I, (? , } , attest that this application for V.d ii
(Pro ssional Engin is na from Application Item 111.1.) (Project Name from Application It14m.I.l)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Desin Criteria for Gravity Sewersji latest version), and the Minimum Desil;n Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE - In accordance with General Statutes 143-215.6A and I43-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application
information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC I¢rQ1 OI)
ow
North Carolina Professional Engineer's seal, signature, and date: Q'�!
O FEssic,, . ti ,
Ith9l�/ •
• \
SEAL
O 55111_ i
Zicryi
3. Applicant's Certification per I5A NCAC 02T .0106(b):
1, _(l IGI � c'�_3_= tat r.Jr f1)4. , attest that this application for
(Signature Authority Name from Appliefation Item 1.3 )
'f1e•• j!G1liE� •t��
(Project Name ram Application t• 11 l)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE In accordance with General Statutes 143-215.6A and I43-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature:
la2Lete4A-- Date: (} 311_a
DESIGN NARRATIVE
FOR
FAST TRACK SANITARY SEWER PERMIT
JOHNSTON COUNTY PUBLIC UTILITIES
CLEVELAND APARTMENTS GRAVITY SEWER EXTENSION
309 E. Market St.
Smithfield, North Carolina 27577
JCPU Project # 21-092-S
October 2021
DESIGN NARRATIVE
1.0 PROJECT DESCRIPTION
The Cleveland Apartments Gravity Sewer Extension project will install approximately 317 linear
feet of 8-inch PVC sanitary sewer from an existing manhole to a cut -in proposed 4' manhole.
The proposed 4' manhole will be cut into an existing 8-inch PVC gravity sewer line that runs
parallel to Cleveland Road (SR 1010). The proposed gravity sewer line's purpose is to divert
flow from the aging system at the rear of the property to the newer system at the roadway
providing a more reliable sanitary sewer service to Cleveland School Apartments and
surrounding facilities. The work will take place entirely on County -owned property.
2.0 EXISTING SYSTEM
The existing collection system in this area is aging. It was originally built to serve the school but
since that time several other facilities have been added and the school has been converted to
private apartments. The system is failing and causing issues for all facilities tied to it.
3.0 PROPOSED ADDITIONS
The proposed construction will add approximately 317 linear feet of 8-inch PVC
sanitary sewer, 2 cleanouts, and a 4' manhole. The pipeline will be laid at a 1.05% grade. No
new flow is expected. The downstream WWPS will remain the Josephine WWPS (WQ0028867).
.S
h
USGS V.S. DEPARTMENTS.W�µOf HE INTERIOR
SURVEY
'.try[
h 7 s
Ir
emum 1 H .. Swtw Same a..nErr Suer
.�: r✓. w"mir. r..r.r
mum. mu
' US Topo
CLEVELAND APARTMENTS GRAVITY SEWER EXTENSION USGS MAP
SCALE S:Ts 000
lee
•
Jr
EOMONOSON QUADRANGLE
NERTN CAROL.
-YARME SE.R3
•
.S
1f
,11
G
N
a
0 r
0
O.
G
4
mum arum wwmalwr.m. m
nnn
o■n
ono
EDMONDSON. NC
1019.
itf#4,41/00* goon*
DEPARTMENT OF PUBLIC UTILITIES
Post Office Box 2263
SMITHFIELD, NC 27577
(919) 989-5075
October 27, 2021
NCDEQ Water Quality Section
3800 Barrett Drive
Raleigh, NC 27609
RE: Johnston County Public Utilities
Cleveland Apartments Gravity Sewer Extension
Fast Track Sewer System Extension Application
To Whom It May Concern:
NC Dept of Environmental Quality
Nov 01 2021
Raleigh Regional Office
We respectfully submit this application for a Fast Track Sewer System Extension Application for the Cleveland
Apartments Gravity Sewer Extension project. The project installs approximately 317 linear feet of 8-inch PVC sanitary
sewer, a 4' manhole, and 2 cleanouts. The gravity sewer extension's purpose is to re-route flow from Cleveland School
Apartments and surrounding buildings.
Included in this submittal are two copies (one original, one copy) of the following
documentation:
• Fast Track Application (Form: FTA 06-21)
• USGS Quad Maps
• Project Narrative
• Check No. 119582 in the amount of $480.00
Please do not hesitate to contact me should you have any questions or concerns. We
appreciate your time and consideration regarding this matter.
Sincerely,
Johnston County Utilities
�L �vl'iP.eti
Kimberly Rineer, P.E.
cc: Chandra Farmer, Johnston County
Mike Keen, Johnston County