Loading...
HomeMy WebLinkAboutWQ0012633_Regional Office Historical File Pre 2018Fr State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Mr. Donald Cahal, Owner Meadows Mobile Home Park. 309 Viking Drive Columbia, South Carolina 29223 November 8. 1996 Subject: Permit No. WQ0012633 Meadows Mobile Home Park Sewer Extension Union County In accordance with your modification request made by Mr. Hal Spears and Mr. Denver Toler, P.E. on Novemebr 6, 1996 we are forwarding herewith Permit No. WQ0012633 dated November 8, 1996 to you for the continued operation of the subject wastewater collection extension. Because this system was installed without a permit from the State, it is being required to meet the minimum criteria for systems currently being permitted. Therefore, sorne remedial construction is being authorized in this permit as outlined in conditions 14 through 17. The engineer's certification shall serve as proof of compliance with. these conditions. The only modification which is being made in this pert lit issuance, in comparison to the October 31, 1996 issuance, is that the requirement for fillets in the wet well is being dropped. Because these are existing pump stations, there are some concerns on how to properly install the fillets without the threat of them potentially breaking up in the future and causing significant clogging and structural damage to the pumps. This permit shall be effective from the date o.f issuance until rescinded, shall, hereby void Permit No. WQ0012633 issued October 31, 1996 and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you need additional information concerning this matter, please contact Rick Moore at (919) 733- 5083 extension 527. Sincerely, A. Preston '44oward, Jr., Union County Health Department Mooresville: Regional Office, Water Quality Section Alliance Engineering and Surveying Mr. Harold C. Spears P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-5083 FAX (9i9i 733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Donald Cahal Union County FOR THE continued operation of approximately 4,677 linear feet of 6 inch gravity sewer, a 120 GPM pump station with duplex pumps, high water alarms, portable generator connection, manual transfer switch, approximately 1,240 linear feet of 3 inch force main, a 40 GPM pump station with duplex pumps, high water alarms, portable generator connection, manual transfer switch and approximately 820 linear feet of 2 inch force main to serve 115, three bedroom mobile homes and the discharge of 41,400 GPD (22,320 GPD previously allocated) of collected domestic wastewater into the Union County Public Works' existing sewerage system, pursuant to the modification request made by Mr. Hal Spears and Mr. Denver Toler, P.E. on Novemebr 7, 1996 and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment, Health and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, shall hereby void Permit No. WQ0012633 issued October 31, 1996 and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. The sewage and wastewater collected by this system shall be treated in the City of Monroe's Wastewater Treatment Facility prior to being discharged into the receiving stream. 5. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. r 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 8. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 9. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 10. The Permittee shall provide for the pump station and force main the following items: a. Pump on/off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station, b. An air relief valve located at all high points along the force main, c. A screened vent for the wet well, d. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet cannot be maintained, e. Sufficient devices which will protect the pump station from vandals, and f. Flood protection if the pump station is located below the 100-year flood elevation. 11. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division of Water Quality, such as the construction of additional or replacement wastewater collection facilities. 12. NONCOMPLIANCE NOTIFICATION: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704)663-1699 as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 13. This permit shall become voidable unless the agreements between you, the Union County Public Works Department and the City of Monroe for the collection and final treatment of wastewater is in full force and effect. 2 14. Screened vents shall be installed on the wet wells of both pump stations. The engineer's certification shall serve as proof of compliance with this condition. 15. The 2 inch PVC water line between manholes 13 and 14, which does not maintain minimum separation requirements between water and sewer lines, shall be replaced with 2 inch galvanized pipe as indicated on the approved plans. The engineer's certification shall serve as proof of compliance with this condition. 16. A portable generator shall be obtained, and the necessary generator connection equipment shall be installed on the 2 pump stations, for use during power outages. The engineer's certification shall serve as proof of compliance with this condition. 17. At the crossing of the sanitary sewer and storm sewer at approximate station 0+85 on Line D, where the minimum 12 inch separation has not been maintained, the PVC sewer line shall be replaced with 20 linear feet of 6 inch ductile iron pipe, centered under the storm sewer. The engineer's certification shall serve as proof of compliance with this condition. Permit issued this the 8th day of November, 1996 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION OaALL 10,i1 (1c7J2 A. Preston award, Jr., P.4., irector Division of ater Quality By Authority of the Environmental Manageme t Commission Permit Number WQ0012633 3 Permit No. WQ0012633 November 8, 1996 ENGINEER1$ CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, for the Project Name Location Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature Registration No. Date 4