Loading...
HomeMy WebLinkAboutWQ0031738_Regional Office Historical File Pre 2018Oo�lwAr�9Qo II ID 71 Y May 21, 2007 Mr. Larry McMahon, Mayor Town of Norwood Post Office Box 697 Norwood, North Carolina 28128 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality Subject: Permit No. WQ0031738 Town of Norwood Harbor View Subdivision Wastewater Collection System Extension Stanley County, North Carolina Dear Mr. McMahon: In accordance with your application received on May 11, 2007, we are forwarding herewith Permit No. WQ0031738, dated May 21, 2007, to the Town of Norwood for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on. acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-16991 Fax: 704-663-60401 Internet http:11h2o.enr.state.nc.us NorthCarolina Naturally An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Larry McMahon. Page 2 y 21, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Norwood for the construction and operation of approximately 575 linear feet of 8-inch gravity sewer to serve 7 three -bedroom single family homes as part of the Harbor View Subdivision project; and the discharge of 2,520 gallons per day of collected domestic wastewater into the Town of Norwood's existing sewerage system, pursuant to the application received May 11, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Norwood WWTP (NPDES No. NC0021628) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, f for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (Fast Track Sewer Ext Files) G. Richard Sago, II, P.E. (139 EV Hogan Road, Rockingham, NC 28379) Surface Water Protection Central Files PERCS Files I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21_ .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is a unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case by case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. Permit issued this the 21st day of May, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031738 3 Fast Track Engineerinc_Certification Permit No. WQ0031738 May 21, 2007 Larry McMahon, Mayor Town of Norwood PO Box 697 Norwood, NC 28128 G. Richard Sago, II, PE 139 EV Hogan Road Rockingham, NC 28379 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification, and all required supporting documentation, have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ['weekly, ❑ full time) the construction of Harbor View Subdivision, Stanley County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NORTH CAROLINA 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICAT"ION for GRAVITY SE\ RS, PIE <1P ST.ATIt NS,>%NI) FORCE MAINS PACES 2 0 2 0 LL IL Z 2 0 2 2 USE THE TAB KEY TO OVE FROM FIELD TO HELD! Owner. 1a. ji'fown of Norwood Full Legal Name (company, mu Lida lit°yE� HOA, u Application Number: (to be carnpleted by DWQ) Mahon Mayor _ ;1b rLarr�!mmyc Signing Official Name and Title (Please review 15A NCAC 2H 0206(b) for authorized signing o The legal entity who will own this system is [4] Individual ❑ Feder Municipality StatelCounty 0 Private Partnership [1] Corporation LI Other (specify): d PO_Box 697 116 S Main Street Mailing Address NC State .._. � _.. 1 h, 704-474-3416 Te(ephene 1 i. 704-474-3201 Facsimile 2, Project (Facility) lnforrnatio 2a. Harbor View Subdivision Brief Project .._._..._... Narne (permit wil Contact Person: 3a. Rick Sam©! Name and Affiliation of Ss..._ ra'tet 3b. 91© 995-6425 Phone Number o this name) ho Can Answer Question Project is ® New 0. Modification (of an existing permit) le Norwood City lg. 28128-0697 Zap Code 1. townofnorwood carolna.rr.com E-mail 2b. Stanley County Where Project is Located About this Application g 9_ µi Carolina.rr,corn E-mail If Modification, Permit No For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2 Owner is Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2b. If sold, facilities owned by a (rrtust choose one) Public Utility (Instruction III) [] Homeowner Assoc /Developer (Instruction IV) If private, applicant vrill be. © Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item H(3)) © Selling units (lots, townhomes, etc, - go to Item B(2b)) Town of Norwood Owner ofWastewater Treatment Facility (VVV T'F) Treating Norwood Wastewater Plant Name of WWTF �.. Norwood Owner of Downstream Sewer Receiving Sewer Size "f he origin of this wastewater is (check all that apply). ® Residential Subdivision D Apartments/Condominiums O Mobile Horne Park fl School [] Restaurant [] Office water From 0 Car Wash • Institution ❑ Hospital (] Church Li Nursing Home Ej Other (specify) Permit Number of f)ownstream Sewer (i 109 % Dome ti % Indus % Other (specify), Volume of wastewater to be allocated for this particular project. 2520 gallons per day "Do not include previously permitted allocations If the permitted tlo!w is zero, indicate why'. O Interceptor Line - Flow will be permitted in subsequent permits that connect to this line El Flow has already been allocated in Permit No. Li Rehabilitation or replacement of existing sewer witf ac new flow expected Commercial n) FAST-TRA K APPLICATION for GRAVITY SEWERS, PUMP S"i AT ONSr ANl) FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H 0219(I) for Rem P(7) or the design flow for line or pump station sizing if zero flow in the space helow Values other than that in 15A NCAC 2H .0219(I)(1-2) rnust be supported with actual water or wastewater use data in accordance with 15A NCAC 2H _0219(I)(3), 7 singe family homes @ 360 gals/dray = 2520 gals/day /` Summary of Sewer Lines to be Permitted (attach addtticnal sheet if necessary) Size (inches) 8 Length (feet) Gravity or Force Main (use the pull down menu) 575 Gravity z f— Z ENTER TOTAL LINE LENGTH IN MILES 11 d 0 z 0 IL Z Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location 1D Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM t TDH portable generator wltelemetry; 4-wet well storage) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Pe of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? �jYes LI No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following perm n been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? LJ Yes Lj No ❑ Yes ❑ No Sedimentation and Erosion Control Han? Str rrf water? 14. Does this project involve aerial lines or siphons? Check if yes These rila,es will.Liu cons ide;red Ialah.ariarity.and must be, ctIVG.$c.ed ouce very six maiiii 15. Does this project have gravity sewer lines designed at minimum slopes. Bra aware that tiie Division will not accent iitstFalied lines more than 10% flatlet I lan the. minimum sir, collected prior In submitting the final engineering certiification.. El Yes El No [l El N/A Eej N!A } N/A hVula Ire "!RA(: K APPL1CA 1 R N fur (RAVl'1,Y SF %''FRS, PUMP ST/ — ONS, ANt) FORCE MAINS PAGE 0 z Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM ETA 02/03 (FAST -TRACK SEWER SYSTEMS)°' to collect and record the stream classification data below (attach additional sheets as, necessary). This document is .available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody, AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope Waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) 1 Name of Waterbody Lake Tillery County Stanley River Basin Yadkin Waterbody Stream Waterbody Index Classification W S-I V, E, CA 13-(1) Submit the 13,5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1, Mr. Larry McMahon, attest that this application for Harbor View Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note. In accordance with North Carolina General Statutes 143-215, 6A and 143-215 613, any person who knowingly makes any faise statement, representation., or certification i ,any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10 000 ors well a lilt/ penalties up to $25,O00 per violation. /)r fficial Signature essional Engineer's Certification_ est that this application for Harbor View Subdivision has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Force Mains adopted June 1, 2000 and the watershedclassification in accordance with Division guidance Although certain portions of this submittal package may have been developed by other professionals, tnciusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design Note: In accordance with NC Genera/ Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed .$10,000 as well as civil penalties ,wv,(A4g,k,000 per violation, "t+ . Richard Sao PI Professional Engineer Name 2h, NIA Engineering Firm 2c '139 EV Mogan Road Mailing Address 2d Rockingham City 2g 910 995-6425 2h. Telephone Far si 2e NC 2f 28379 State Zip gsagoit@cerolina.rr corer E o7ai! Sign Date MAY 1 TER IM INN T ht (C) 1997, M ptech, Inc. VIP' a Central Files: APS SWP I 05/17/07 Permit Number WQ0031738 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation sonja.basinger Permitted Flow 2520 Facility Facility Name Harbor View Subdivision Location Address Owner Major/Minor Region Minor Mooresville County Stanly Facility Contact Affiliation Owner Name Owner Type Town of Norwood Government - Municipal Owner Affiliation W PO Box 697 Norwood Dates/Events Smith, Administrator Town NC 28128 Orig Issue Scheduled Issuance Public Notice Issue Effective h5'1-1 /b1 Regulated Activities Requested/Received Events App Received 05/11/07 Draft Initiated Subdivision Additional information requested Wastewater collection Additional information received Outfall NULL Expiration Waterbody Name Stream Index Number Current Class Subbasin