Loading...
HomeMy WebLinkAboutSW6210601_Supplement-EZ Form_20211123SUPPLEMENT-EZ COVER PAGE FORMSLOADED 'ROJECT INFORMATION ................. .............. _.__..... 1 Project Name 2 Project Area (ac) 3 Coastal Wetland Area (ac) 4 Surface Water Area (ac) 5 Is this project High or Low Density? 6 Does this project use an off -site SCM? :OMPLIANCE WITH 02H .1003(4) Graceland Subdivision 54.95 0 0.81 Low No 7 Width of vegetated setbacks provided (feet) _ 30 8 Will the vegetated setback remain vegetated? Yes 9 y'if BUA is proposed in the setback, does it meet NCAC 02H. 1 003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No JUMBER AND TYPE OF SCMS: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 'Stormwater Wetland 15 Permeable Pavement 16 ;Sand Filter 17 'Rainwater Harvesting (RWH) 18 'Green Roof 19 Level Spreader -Filter Strip (LS-FS) 20 : Disconnected Impervious Surface (DIS) 21 Treatment Swale 22 Dry Pond _ 23 StormFilter 24 Silva Call 25 !Bayfilter 26 Filterra FORMSLOADED DESIGNER CERTIFICATION 27 Name and Title. _ _ C. Scott Brown, PE 28 L Organization: _ _ _ _ _ 4D Site Solutions, Inc. 29 _ Street address: _ _ __ 409 Chicago Drive - Suite 112 30 City State, Zip: _ __ Fayetteville, NC 28306 31 Phone number(s): 910-42676777 32 Email sbrown@4dsitesolutions.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. NC SEAL = 027452 C) ' .ccIVGINEAP -A- ,,SCoTT ' �. A� Signature o Designer Date [f - Z3-zl DRAINAGE AREAS Is this a high density project? No If so, number of drainage areas/SCIVIs 0 ;Does this project have low density areas? Yes 4 4 If so, number of low density drainage areas Is all/part of this project subject to previous rule 5 iversions? No I FORMS LOADED AREA INFORMATION 4 Type of SCM Conveyances 5 iTotal drainage area (sq ft) 2,393,633 6 �Cinsite drainage area (sq ft) 2,393,633 7 �Ciffsitedrainage area (sq ft) 0 BUA in pTqject,(sq ft) 5785.57 sf "!Total New BUA on subdivided lots (subject to 9 _permitting) q 371223 sf New BUA not on subdivided lots (subject to 10 permitting) (sf) 203229sf 11 , �CiffsiteBUA 12 Breakdown of new BUA not on subdivided lots: _7 Parking (sq 1) - Sidewalk (sq ft) Roof 1— ffN Roadway,(sqft)_ Future (sq_ ft) —F Other, please specify in the comment box below (sq ft) New infiltrating permeable pavement on 13 ,subdivided lot (sq ft) 'New infiltrating permeable pavement not on _14. -,subdivided jots (sq ft) Existing BOA that will remain (not subject to 15 'permitting) (sq ,ft) . i 16 iExistinq BUA that is already permitted (sq ft), 17 Existing BUA that will be removed (sq ft) 18 Percent BOA i 19, lDesign 'storm (inches) 20 Design volume of SCM - (cu ft) -f- ;Calculation method for design volume 27709sf 1 2319-3.633 2,393,633 578557sf 371223sf 203229sf sf 27709sf 175520 sf sf f sf sf sf sf sf sf sf 4105 sf 4105 sf 246/6- 24% . . .. ...... '!Please use this space to provide any additional information about the 22 drainage area(s): LOW DENSITY 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of Flow? Yes 3 ! Has the use of piping been minlmized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 3 of 5 ',Maximum velocity in the vegetated conveyances during the 10-year storm? 4.5 6 Are curb outlet swales proposed? Yes 7 Maximum longitudinal slope of curb outlet swale(s) (%) _ 5% 8 Bottom width of curb outlet swale(s) (feet) 2 ft 9 Maximum side slope of curb outlet swale(s) (H:V) 3:1 10 Minimum length of curb outlet swale(s) (feet) 100 ft 11 Are treatment swales used instead of curb outlet swales? No 12 ! Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule .1003 proposed? No 15 Please use this space to provide any additional information about this low density project: Swale Drainage BUA Pervious q Slope VamW VK.M Flow depth # Area (art area (cfs) P/.) (fPS) (fPS) (g) 1 1.06 0.08 0.98 0.35 1.43 0.75 4.50 1 29 0.35 2 3.32 0.26 3.06 0.35 4.47 0.70 4.50 1.48 0.73 3 2.84 0.22 2.62 0.35 3.83 0 50 4.50 1,50 0.83 4 1.97 0.61 1.36 0.50 3.79 0 75 2.00 1.51 0.84 6 _ 0.72 0.17 0.55 0.45 2.55 1.00 2.00 1.71 0.45 6 4.30 0.99 3.31 0.45 7.45 0.50 2.00 1.77 0.90 7 1.39 043 0.96 0.50 3.71 0.50 2.00 1.46 0.64 8. 5.09 0.78 4 31 0.40 7.84 0.60 4.50 1.91 0.88 9 2.65 0.61 2.04 0.45 4.60 1.80 4.50 2.48 0.52 10 1.49 0.34 1.15 0.45 3.57 1.90 4.50 1.89 0:53 11 1.95 0.30 1.65 0.40 3.01 0.30 4.50 115 0.66 12 1.65 0.38 1.27 0.45 2.85 0.30 4,50 1.14 0.65 13 1927 4.45 14.82 0.45 33.38 1.00 4.50 3.77 1.42 14 19.49 4.50 14.99 0.45 33.77 1.20 4.510 3.98 1.38 15 5.32 113 4.09 0.45 9.21 0.80 4.50 2.03 0.94 16 25.91 5.98 19.93 0.45 44.89 0.70 2.00 t 85 2.53 _ 17 1.77 0.41 1.36 0.45 3.06 0.60 4.50 1.53 0.74 18 0.53 0.24 0.29 0.60 2.50 0.50 4.50 1.32 0.53 19 1.69 039 1.30 0.45 2.92 O 50 450 1.37 0.57 20 3,35 0.77 2:57 0:45 5.60 1.50 4.50 1.36 0.47 21 3.96 0.91 3.04 0.45 6.85 0.60 4.50 1.28 0.54 22 4.68 1.08 3.60 0.45 8.10 4 00 4.50 2.14 0.44 23 1:57 036 1.21 0:45 2.72 0.50 4:50 1:35 0:55 as 28 26 27 28 -29