HomeMy WebLinkAboutWQ0033597_Regional Office Historical File Pre 2018Mr. David Treme, City Manager
City of Salisbury
P.O Box 479
Salisbury, NC 28145
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Coleen H. Sullins, Director
Division of Water Quality
November 19, 2008
Subject: Permit No. WQ0033597
Sanitary Sewer Extension to serve Sacred
Heart
Wastewater Collection System
Rowan County, North Carolina
Dear Mr. Treme,
In accordance with your application received on November 13, 2008, we are forwarding
herewith Permit No. WQ0033597 dated November 19, 2008, for the construction only of the subject
wastewater collection system extension. This permit shall be effective from the date of issuance until
rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter
shall be considered a part of this permit and is therefore incorporated therein by reference.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any
individual system -wide collection system permit issued to the Permittee.
Permitting of this project does not constitute an acceptance of any part of the project that does
not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable,
unless specifically mentioned herein. Division approval is based on acceptance of the certification
provided by a North Carolina -licensed Professional Engineer in the application. It shall be the
Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria
and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute
§143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection
facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board.
Mailing Address Phone (704) 663-1699
610 East Center Avenue, Suite 301 Fax (704) 663-6040
Mooresville, NC 28115
Location
610 East Center Avenue, Suite 301
Mooresville, North Carolina
None
hCarolina
atura!/J
Internet: www.ncwaterquatitv.org Customer Service 1-877-623-6748
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
Mr. Treme
Page 2
November 19, 2008
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby
granted to the City of Salisbury for the construction and operation of approximately 742 linear feet of 8-
inch gravity sewer, and the discharge of zero (0) gallon per day of collected domestic wastewater into
Salisbury -Rowan WWTP- (Grant's Creek Train) existing sewerage system pursuant to the application
received November 13, 2008, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable; and other supporting data subsequently filed and approved by the Department of
Environment and Natural Resources and considered a part of this permit.
The sewage and wastewater collected by this system shall be treated in the Grant Creek
Wastewater Treatment Facility WWTP (NPDES No.NC0023884) prior to being discharged into the
receiving stream.
Assessing subsequent impacts to the downstream collection system and treatment
facility is the complete responsibility of the City of Salisbury. The City of Salisbury must utilize
whatever tracking tools necessary for planning additions of sewer flow in order to maintain
compliance with the WWTP permitted limits and the WQCS00019 permit requirements.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150E of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
if you need additional information concerning this matter, please contact Mr. Samar Bou-
Ghazale at (704) 663-1699.
Sincerely,
/¢ -
for Coleen H. Sullins, Director
cc: Mooresville Regional Office, Collection System Permit Files
Darryl Wagoner, Salisbury Engineering & Planning
Surface Water Protection Central Files
PERCS
I
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically
mentioned herein.
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T
.0403:
a. The sewer system shall be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan shall be developed and implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shall be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1C.
1
I
4. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State.
6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these
permitted facilities, the completed Engineering Certification form attached to this permit shall be
submitted with the required supporting documents to the address provided on the form. A complete
certification is one where the form is fully executed and the supporting documents are provided as
applicable.
7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life
of the wastewater collection facilities.
8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215.6C.
9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities.
10. The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other government agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B .0200 and 15A NCAC 2H .0500.
11. Noncompliance Notification:
The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville
Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than
24 hours or on the next working day, following the occurrence or first knowledge of the occurrence
of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
2
I
Voice mail messages or faxed information is permissible, but shall not be considered as the
initial verbal report. Overflows and spills occurring outside normal business hours may also be
reported to the Division of Emergency Management at telephone number (800) 858-0368 or
(919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by
completing Part I of Form CS-SSO (or the most current Division approved form), within five days
following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most
current Division approved form) can also be completed to show that the SSO was beyond
control.
12. This permit shall be for the construction of the wastewater collection facilities only. No flow shall
be made tributary to the subject facilities until a permit modification application is submitted (with
the appropriate fee), a modified permit is issued, and the Engineer's Certification is received
and approved by the Division. Issuance of this Construction only (No flow/0 flow) permit does
not prioritize or obligate the Division to guarantee future issuance of a sewer extension permit
modification.
Permit issued this the 19w day of November 2008.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
211
Coleen H. Sullins, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0033597
3
Fast Track Engineering Certification
Permit No. WQ0033597
November 19, 2008
Sanitary Sewer Extension to serve Sacred Heart
City of Salisbury
217 South Main Street
Salisbury, NC 28144
David Treme
City Manager
City of Salisbury
P.O. Box 479
Salisbury, NC 28145
Darryl Wagoner, P.E.
Salisbury Eng.& Planning
516-A North Main Street
Salisbury, NC 28144
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• Supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for anv changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division.
ENGINEER'S CERTIFICATION
❑ Partial ❑ Final
, as a duly registered Professional Engineer in the State of North Carolina, having been
authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Sanitary Sewer Extension to Serve
Sacred Heart Collection Sewer System, a Rowan County project for the Permittee, hereby state that, to the best of my
abilities, due care and diligence was used in the observation of the construction such that the construction was
observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum
Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable;
and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
610 EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Nu..,
(to be completed by
Owner/Permittee:
of Salisbury
Full Legal Name (company, municipality, HOA, utility, etc.
1 b. David W. Treme, City Manager
Signing Official Name and Title (Please review 1 A NCAC 2T .0
lc. The legal entity who will own this system
0 Individual 0 Federal
0 1d
LL Mailing Address
z
0
0
P. O. sox 479
N.C.
State
1h, 704-638-5200
for authorized signing o
Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other
704-638-8458
Telephone Facsimile
2. Project (Facility) Information:
2a, Sanitary Sewer Extension to serve Sacred Heart
Brief Project Name (permit will refer to this name)
Contact Person:
Darryl Wagoner , Owner Salisbury Engineering& Planning .
Name and Affiliation of Someone Who Can Answer Questions About this Application
le, Salisbury
City.
^1g. 28145
Zip Code
dmikk salisburync.gov
E-mail
2b. Rowan
County
3b, 704-633-8550
Phone Number
ting permit)
3c. seand
E-mail
Project is Located
aol.com
odifcation, Permit No.:
2, Owner is Public (skip to Item 8(3)) 0 Private (go to item 2(a))
2a. If private, applicant will be:
0 Retaining Ownership (i.e. store, church, single office, etc.) o
0 Leasing units (lots, townhomes, etc. - skip to Item B(3))
0 Selling units (lots„ townhomes, etc. - go to Item B(2b))
City of Salisbury
2b, If sold, facilities owned by a (must clto+ose one)
0 Public Utility (Instruction C)
0 Homeowner Assoc./Developer (Instruction D)
Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Proje
_ 4b.NC 0023884
..,
(
4a. Salisbury -Rowan WWTP Grants Creek Train)
Name of WWTF
5a. City of Salisbury a5b. 8°4 Gravity
Owner of Downstream Sewer iReceiving Sewer Size Force Main
The origin of this wastewater is (check ail that apply):
[I Residential Subdivision
0 Apartments/Condominiums
0 Mobile Home Park
School
0 'Restaurant
❑ Office
WWTF Permit No,
Permit # of Downstream Se
0 Retail (Stores, shopping centers)
0 Institution
0 Hospital
Church
0 Nursing. Home
0 Other (specify):
uction E
omestic/Commercial
% Industrial (attach
description)
(RO: contact your Regional Office
Pretreatment staff)
°/q Other (specify):
7. Volume of wastewater to be allocated or permitted for this particular project: gallons per day
*Do not include future flows or previously permitted allocations
8. If the permitted flow is zero, indicate why.
Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line
0 Flow has already been allocated in Permit No.
0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a
permit is required)
9. Provide the wastewater flow calculations used
the value in Item B(7) AND/OR the design flow
in determining the permitted flow in accordance
for fine or pump station sizing if a reduced or
2T .0114 (b) and (c) must be supported with
(f).
additional sheets if necessary)
Length (feet)
with 15A NCAC 2T .0114 for
zero flow is being requested in
actual water or wastewater use
New Gravity or Additional
Force Main
Item B(7). Values other than that in 15A NCAC
data in accordance with 15A NCAC 2T .0114
10. Summary of Sewer Lines to be Permitted (attach
Size (inches)
g"
' 742'
Gravity
11. Summary of Pump Stations w! associated Force Mains to be Permitted (attach additional sheets as necessary)
Pump Station Location ID (self chosen - as shown on plans/map for reference)
Design Flow Operational Point
(MGD) GPM @TDH
Power Reliability Option
1 - permanent generator wlATS;
2 - portable generator wIMTS
Force Main Size ' Force Main Length
Pump Station Location ID (self chosen -
as shown on planslmap for reference)
w!MTS
Design Flow
(MGD)
Operational Point
GPM @TDH
Power Reliability Option
1 - permanent generator wIATS; 2 - portable generator
Force Main Size
Force Main Length
12. Will the wastewater flow in the proposed sewer
lines or pump stations be able to be directed to another treatment facility?
2n6 treatment facility
❑ Yes 0 No If Yes, permit number of
(RO — if "yes" to 8,12 please contact the Central
i13. Does the sewer system comply with the Minimum
Mains (latest version), the Gravity Sewer Minimum
applicable?
Office PERCS Unit)
Design Criteria for the Fast Track Permitting of Pump Stations and Force
Design Criteria (latest version) and 15A NCAC Chapter 2T as
the pertinent minimum design criteria or regulation and indicate why a
SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS
WITH YOUR APPLICATION
0 Yes ■ No If No, please reference
variance is requested.
PERTINENT TO THE VARIANCE
Have the following permits/certifications been submitted for approve i for the system or project to be served?
Wetland/Stream Crossings - General Permit or 401 Certification? Yes ❑ No 0 N/A
Sedimentation and Erosion Control Plan? Yes 0 No 0 N/A
Starmwater? ❑ Yes 0 No u' N/A
45. Does this project inciud'e any high priority Vines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference
manholes)? These lines will be considered high priority and must be checked once every six months
Check if Yes: ❑ and provide details
Owner/Permittee"s Certification: (Signature of Signing Official and Project Name)
1, David W Trerne, attest that this application for -tc d Heart has been reviewed by me and is
accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not
completed and that if all required supporting documentation and attachments am not included, this application package
is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and
143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application
shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10, 000 as well as civil penalties up to
$25, 000 per violation.
Date
ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS
APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY
tlt} TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305
Z
a
2. Professional Engineer's Certification: (Signature of i3esign. Engineer and Project Name)
1, Darryl L. Wagoner, attest that this application for Sacred Heart has been reviewed by me and is accurate,
complete and consistent with the information in the engineenl ig H., is, calculations, and all other supporting documentation`
to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in
accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February
12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June
1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have
developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that
l have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC
Genera! Statutes 143-215.6A and 143-215,68, any person who knowingly makes any false statement representation, or
certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as
well as civil penalties up to $25, 000 per violation.
2a, Darryl L. Wagoner .m._
Professional Engineer Name
2b, Salisbury Engineering & Planning
Engineering Firm
2c. 516-A North Main Street
Mailing Address
2d. Salisbury
City
2e. N.C. 2f. 28144
State Zip
2g. 704-633-8550 2h. 704-633-8550 2i. se nd c l.com
Facsimile E-mai
Telephone
N
Project ,Applia
Project Name
Afore than one F
pump N atio rs Won
State of North Carolina
Department of En%ironrnent and Natural Resources
Division of Water Quality
Flow Tracking/Aeecptanee for Sewer Extension Permit Applications
(FTSE 10!07)
Name: C'i,,,,,pf Sa
which flow is being t
may be required ar a Sin
of the prolrrxsed waste wa
ted: Sanitary Sewer Extension to serve Sacred heart
of the ff°T{71' is neat responsible far all
1. Complete this section only if you are the owner of the waste
a, WWTP Facility 'Name: Salisbury Rowan W WT P' (Grant t;
h. WV'T1' Facility Permit
_NCB 023884
c. WWTP facility's permitted flow
d. Estimated obligated flow not yet tributary to the WWII'
s . WWTP facility's actual avg. flow
f Total flow for this specific request
Train)
All flo
0.298
5,109
0.000
g. Total actual and obligated flows to the facility� 5.4,07 ..
h. Percent of permitted flow used 72.09°` _.. .
II. Complete this section for each pump station you are responsible for along the route ofthis
proposed wastewater flow.
List pump stations located betw
Pump Station Name
roiect connection point and the WWII'
rox. Capacity, MGI.) Approx. Current Avg.
(Firm/Design) Daily Flow, MOD
Certiticatio:,
Trey Jones, P.h . ,certify that toile. Lest ot`my knowledge, the addition of the volume of
Ater to be perntiitc•tl itt tftis laa «jest has been evaluated along the route to the receiving wastewater
treatment facility and that the s project is not anticipated to cause any capacity related
sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment
plant under normal circumstances. This analysis has been performed in accordance with local established
policies and procedures using the best available data.. This certification applies to those items listed above
in Sections 1 and 11 for which I am the responsible party. Signature of this form indicates acceptance of
this wastewater flow.
L
Si sting Official Signature f")ate
SALTS WRY ENGINEEJ !NG & PLANNING
6-A NORTH MAIN STREET • SALTSBURY, NC 28144
November 1.1 2008
DENR
Division rf Water Quality
610 East .enter, Ave.., Suite 301
Mooresville, N. C. 2811.5
RE: Sanitary Sewer Extension to serve Sacred
Rowan County
Dear Sir or Madam:.
DAPAYL L WAtONIE
O4-6:.;a-8550
Ug
rPrtc n
Please find enclosed two applications and a il.ow/tracking; acceptance letter for approval
for the public and private portions of the above referenced project. please advise
immediately if additional information is required.
Since
Ray Capps
Enclosur
Central Files: APS� SWP_
11/19/08
Permit Number WQ0033597 Permit Tracking Slip
Program Category Status Project Type
Non -discharge Active New Project
Permit Type Fast Track Version Permit Classification
Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual
Extensions
Primary Reviewer Permit Contact Affiliation
samar.bou-ghazale
Permitted Flow
0
Facility
Facility Name
Sanitary Sewer to serve Sacred Heart
Location Address
Owner
Major/Minor Region
Minor Mooresville
County
Rowan
Facility Contact Affiliation
Owner Name Owner Type
City of Salisbury Government - Municipal
Dates/Events
Orig Issue
11/19/08
Owner Affiliation
David Treme, City Manager
PO Box 479
Salisbury
NC 28145
App Received
11/13/08
Draft Initiated
Scheduled
Issuance
Public Notice Issue
11/19/08
Effective Expiration
11/19/08
Regulated Activities Re nested/'eceived Events
Additional information requested
Additional information received
Church
School
Wastewater collection
Outfall NULL
Waterbody Name
Stream Index Number Current Class Subbasin