HomeMy WebLinkAboutWQ0033597_Regional Office Historical File Pre 2018Mr. David Treme, City Manager City of Salisbury P.O Box 479 Salisbury, NC 28145 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality November 19, 2008 Subject: Permit No. WQ0033597 Sanitary Sewer Extension to serve Sacred Heart Wastewater Collection System Rowan County, North Carolina Dear Mr. Treme, In accordance with your application received on November 13, 2008, we are forwarding herewith Permit No. WQ0033597 dated November 19, 2008, for the construction only of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mailing Address Phone (704) 663-1699 610 East Center Avenue, Suite 301 Fax (704) 663-6040 Mooresville, NC 28115 Location 610 East Center Avenue, Suite 301 Mooresville, North Carolina None hCarolina atura!/J Internet: www.ncwaterquatitv.org Customer Service 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Mr. Treme Page 2 November 19, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Salisbury for the construction and operation of approximately 742 linear feet of 8- inch gravity sewer, and the discharge of zero (0) gallon per day of collected domestic wastewater into Salisbury -Rowan WWTP- (Grant's Creek Train) existing sewerage system pursuant to the application received November 13, 2008, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Grant Creek Wastewater Treatment Facility WWTP (NPDES No.NC0023884) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of the City of Salisbury. The City of Salisbury must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the WQCS00019 permit requirements. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. if you need additional information concerning this matter, please contact Mr. Samar Bou- Ghazale at (704) 663-1699. Sincerely, /¢ - for Coleen H. Sullins, Director cc: Mooresville Regional Office, Collection System Permit Files Darryl Wagoner, Salisbury Engineering & Planning Surface Water Protection Central Files PERCS I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 I 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 I Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. This permit shall be for the construction of the wastewater collection facilities only. No flow shall be made tributary to the subject facilities until a permit modification application is submitted (with the appropriate fee), a modified permit is issued, and the Engineer's Certification is received and approved by the Division. Issuance of this Construction only (No flow/0 flow) permit does not prioritize or obligate the Division to guarantee future issuance of a sewer extension permit modification. Permit issued this the 19w day of November 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 211 Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033597 3 Fast Track Engineering Certification Permit No. WQ0033597 November 19, 2008 Sanitary Sewer Extension to serve Sacred Heart City of Salisbury 217 South Main Street Salisbury, NC 28144 David Treme City Manager City of Salisbury P.O. Box 479 Salisbury, NC 28145 Darryl Wagoner, P.E. Salisbury Eng.& Planning 516-A North Main Street Salisbury, NC 28144 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Sanitary Sewer Extension to Serve Sacred Heart Collection Sewer System, a Rowan County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Nu.., (to be completed by Owner/Permittee: of Salisbury Full Legal Name (company, municipality, HOA, utility, etc. 1 b. David W. Treme, City Manager Signing Official Name and Title (Please review 1 A NCAC 2T .0 lc. The legal entity who will own this system 0 Individual 0 Federal 0 1d LL Mailing Address z 0 0 P. O. sox 479 N.C. State 1h, 704-638-5200 for authorized signing o Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other 704-638-8458 Telephone Facsimile 2. Project (Facility) Information: 2a, Sanitary Sewer Extension to serve Sacred Heart Brief Project Name (permit will refer to this name) Contact Person: Darryl Wagoner , Owner Salisbury Engineering& Planning . Name and Affiliation of Someone Who Can Answer Questions About this Application le, Salisbury City. ^1g. 28145 Zip Code dmikk salisburync.gov E-mail 2b. Rowan County 3b, 704-633-8550 Phone Number ting permit) 3c. seand E-mail Project is Located aol.com odifcation, Permit No.: 2, Owner is Public (skip to Item 8(3)) 0 Private (go to item 2(a)) 2a. If private, applicant will be: 0 Retaining Ownership (i.e. store, church, single office, etc.) o 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots„ townhomes, etc. - go to Item B(2b)) City of Salisbury 2b, If sold, facilities owned by a (must clto+ose one) 0 Public Utility (Instruction C) 0 Homeowner Assoc./Developer (Instruction D) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Proje _ 4b.NC 0023884 .., ( 4a. Salisbury -Rowan WWTP Grants Creek Train) Name of WWTF 5a. City of Salisbury a5b. 8°4 Gravity Owner of Downstream Sewer iReceiving Sewer Size Force Main The origin of this wastewater is (check ail that apply): [I Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park School 0 'Restaurant ❑ Office WWTF Permit No, Permit # of Downstream Se 0 Retail (Stores, shopping centers) 0 Institution 0 Hospital Church 0 Nursing. Home 0 Other (specify): uction E omestic/Commercial % Industrial (attach description) (RO: contact your Regional Office Pretreatment staff) °/q Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why. Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) 9. Provide the wastewater flow calculations used the value in Item B(7) AND/OR the design flow in determining the permitted flow in accordance for fine or pump station sizing if a reduced or 2T .0114 (b) and (c) must be supported with (f). additional sheets if necessary) Length (feet) with 15A NCAC 2T .0114 for zero flow is being requested in actual water or wastewater use New Gravity or Additional Force Main Item B(7). Values other than that in 15A NCAC data in accordance with 15A NCAC 2T .0114 10. Summary of Sewer Lines to be Permitted (attach Size (inches) g" ' 742' Gravity 11. Summary of Pump Stations w! associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow Operational Point (MGD) GPM @TDH Power Reliability Option 1 - permanent generator wlATS; 2 - portable generator wIMTS Force Main Size ' Force Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) w!MTS Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator Force Main Size Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? 2n6 treatment facility ❑ Yes 0 No If Yes, permit number of (RO — if "yes" to 8,12 please contact the Central i13. Does the sewer system comply with the Minimum Mains (latest version), the Gravity Sewer Minimum applicable? Office PERCS Unit) Design Criteria for the Fast Track Permitting of Pump Stations and Force Design Criteria (latest version) and 15A NCAC Chapter 2T as the pertinent minimum design criteria or regulation and indicate why a SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS WITH YOUR APPLICATION 0 Yes ■ No If No, please reference variance is requested. PERTINENT TO THE VARIANCE Have the following permits/certifications been submitted for approve i for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? Yes ❑ No 0 N/A Sedimentation and Erosion Control Plan? Yes 0 No 0 N/A Starmwater? ❑ Yes 0 No u' N/A 45. Does this project inciud'e any high priority Vines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details Owner/Permittee"s Certification: (Signature of Signing Official and Project Name) 1, David W Trerne, attest that this application for -tc d Heart has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments am not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY tlt} TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Z a 2. Professional Engineer's Certification: (Signature of i3esign. Engineer and Project Name) 1, Darryl L. Wagoner, attest that this application for Sacred Heart has been reviewed by me and is accurate, complete and consistent with the information in the engineenl ig H., is, calculations, and all other supporting documentation` to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC Genera! Statutes 143-215.6A and 143-215,68, any person who knowingly makes any false statement representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 2a, Darryl L. Wagoner .m._ Professional Engineer Name 2b, Salisbury Engineering & Planning Engineering Firm 2c. 516-A North Main Street Mailing Address 2d. Salisbury City 2e. N.C. 2f. 28144 State Zip 2g. 704-633-8550 2h. 704-633-8550 2i. se nd c l.com Facsimile E-mai Telephone N Project ,Applia Project Name Afore than one F pump N atio rs Won State of North Carolina Department of En%ironrnent and Natural Resources Division of Water Quality Flow Tracking/Aeecptanee for Sewer Extension Permit Applications (FTSE 10!07) Name: C'i,,,,,pf Sa which flow is being t may be required ar a Sin of the prolrrxsed waste wa ted: Sanitary Sewer Extension to serve Sacred heart of the ff°T{71' is neat responsible far all 1. Complete this section only if you are the owner of the waste a, WWTP Facility 'Name: Salisbury Rowan W WT P' (Grant t; h. WV'T1' Facility Permit _NCB 023884 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWII' s . WWTP facility's actual avg. flow f Total flow for this specific request Train) All flo 0.298 5,109 0.000 g. Total actual and obligated flows to the facility� 5.4,07 .. h. Percent of permitted flow used 72.09°` _.. . II. Complete this section for each pump station you are responsible for along the route ofthis proposed wastewater flow. List pump stations located betw Pump Station Name roiect connection point and the WWII' rox. Capacity, MGI.) Approx. Current Avg. (Firm/Design) Daily Flow, MOD Certiticatio:, Trey Jones, P.h . ,certify that toile. Lest ot`my knowledge, the addition of the volume of Ater to be perntiitc•tl itt tftis laa «jest has been evaluated along the route to the receiving wastewater treatment facility and that the s project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data.. This certification applies to those items listed above in Sections 1 and 11 for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. L Si sting Official Signature f")ate SALTS WRY ENGINEEJ !NG & PLANNING 6-A NORTH MAIN STREET • SALTSBURY, NC 28144 November 1.1 2008 DENR Division rf Water Quality 610 East .enter, Ave.., Suite 301 Mooresville, N. C. 2811.5 RE: Sanitary Sewer Extension to serve Sacred Rowan County Dear Sir or Madam:. DAPAYL L WAtONIE O4-6:.;a-8550 Ug rPrtc n Please find enclosed two applications and a il.ow/tracking; acceptance letter for approval for the public and private portions of the above referenced project. please advise immediately if additional information is required. Since Ray Capps Enclosur Central Files: APS� SWP_ 11/19/08 Permit Number WQ0033597 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation samar.bou-ghazale Permitted Flow 0 Facility Facility Name Sanitary Sewer to serve Sacred Heart Location Address Owner Major/Minor Region Minor Mooresville County Rowan Facility Contact Affiliation Owner Name Owner Type City of Salisbury Government - Municipal Dates/Events Orig Issue 11/19/08 Owner Affiliation David Treme, City Manager PO Box 479 Salisbury NC 28145 App Received 11/13/08 Draft Initiated Scheduled Issuance Public Notice Issue 11/19/08 Effective Expiration 11/19/08 Regulated Activities Re nested/'eceived Events Additional information requested Additional information received Church School Wastewater collection Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin